Diabetes Technol Ther ; 2(2): 199-207, 2000.
Article in English | MEDLINE | ID: mdl-11469259

ABSTRACT

BACKGROUND: Improved glycemic control significantly reduces long-term microvascular complications of diabetes mellitus associated with chronic hyperglycemia. The GlucoWatch biographer is designed to facilitate intensive diabetes management by providing automatic, frequent, and noninvasive glucose readings up to three times per hour for as long as 12 hours. METHODS: The device extracts glucose through intact skin using reverse iontophoresis and measures the extracted glucose with an electrochemical biosensor. A clinical trial was performed to assess the effect of acetaminophen, a potential interference for traditional blood glucose meters, on the accuracy of the GlucoWatch biographer in adult subjects with diabetes (n = 18). One thousand milligram doses of acetaminophen were administered to subjects in two groups: one to achieve Cmax (peak acetominophen concentration) at the time of biographer calibration and the other to achieve Cmax during the measurement period. The biographer readings were compared to serial fingerstick blood glucose measurements. RESULTS: Time profiles over 9 hours show close tracking of the biographer glucose results with fingerstick blood glucose measurements for all groups. The mean difference between the two measurements is between 8 and 12 mg/dL for all groups. The mean absolute value of the relative difference is less than 20%, and more than 93% of the points were in the clinically acceptable (A+B) region of the Clarke Error Grid. No statistically significant differences were found for any accuracy measurement across all groups. CONCLUSIONS: The GlucoWatch Biographer provides frequent measurements of glucose over a 12-hour period with high accuracy. No effect of therapeutic dosage of acetaminophen on the accuracy of the glucose readings was found.


Subject(s)
Acetaminophen/pharmacology , Blood Glucose Self-Monitoring/methods , Blood Glucose/analysis , Monitoring, Ambulatory/instrumentation , Monitoring, Ambulatory/methods , Adult , Analysis of Variance , Automation , Biosensing Techniques , Blood Glucose Self-Monitoring/instrumentation , Calibration , Electrochemistry , Equipment Design , Humans , Reproducibility of Results , Time Factors , United States , White People
2.
Ann Med ; 32(9): 632-41, 2000 Dec.
Article in English | MEDLINE | ID: mdl-11209971

ABSTRACT

The GlucoWatch (Cygnus, Inc, Redwood City, CA, USA) biographer provides automatic, frequent and noninvasive blood glucose measurements for up to 12 h. The device extracts glucose through intact skin where it is measured by an amperometric biosensor. Clinical trials in a variety of environments have shown that the biographer provides accurate and precise glucose measurements when compared with serial fingerstick blood glucose measurements. Mean difference between these measurements was 0.26 mmol/L in the home environment (r = 0.80). Over 94% of biographer readings were in the clinically acceptable A+B region of the Clarke Error Grid. A slight positive bias is observed for the biographer readings at low glucose levels. Biographer precision, as measured by coefficient of variation (CV)%, is approximately 10%. The low glucose alert function of the biographer was able to detect up to 75% of hypoglycaemic episodes with a low false alert level. Skin irritation, characterized by erythema and oedema was either nonexistent or mild in over 87% of subjects and resolved in virtually all subjects without treatment in several days. The GlucoWatch biographer has been shown to be a safe and effective method to track glucose level trends and patterns, which should enable improved glycaemic control for many patients.


Subject(s)
Blood Glucose Self-Monitoring , Diabetes Mellitus/blood , Analysis of Variance , Biosensing Techniques , Blood Glucose Self-Monitoring/instrumentation , Clinical Trials as Topic , Equipment Design , Female , Humans , Hypoglycemia/diagnosis , Male , Middle Aged
3.
Diabetes Care ; 22(10): 1708-14, 1999 Oct.
Article in English | MEDLINE | ID: mdl-10526740

ABSTRACT

OBJECTIVE: The purpose of this study was to compare measurements of glucose obtained via iontophoretic extraction with the GlucoWatch automatic glucose biographer (Cygnus, Inc., Redwood City, CA) with capillary blood glucose values that were determined 1) in a controlled outpatient clinic setting and 2) in a home setting. RESEARCH DESIGN AND METHODS: There were 76 GlucoWatch biographers used on 28 different young adults (21 women and 7 men) with type 1 diabetes (age 30.9 +/- 6.9 years and duration of diabetes 18.4 +/- 8.1 years [mean +/- SD]) in a controlled outpatient clinic setting. Some subjects participated on multiple days. Subjects wore two GlucoWatch biographers, each on the forearm (ventral aspect). Comparisons were made to HemoCue blood glucose analyzer (Aktiebolgat Leo, Helsingborg, Sweden) capillary blood glucose measurements. In addition, GlucoWatch biographers (one each day for 3 consecutive days) were used by 12 subjects (8 women, 4 men) in a home setting. Comparisons were made to capillary blood glucose values determined using the One Touch Profile meter (Johnson & Johnson, New Brunswick, NJ). RESULTS: GlucoWatch biographer glucose values correlated well with capillary blood glucose values determined using the HemoCue analyzer in the clinic setting (r = 0.90, 1,554 paired data points) and using the One Touch Profile meter in the home setting (r = 0.85, 204 paired data points). When 36 subjects wore two biographers simultaneously, the correlation between the two biographers was r = 0.94. The error grid analysis demonstrated that > 96% of biographer glucose values determined in the clinic or home setting were in the clinically acceptable A and B regions. CONCLUSIONS: This study confirms the accuracy and precision of glucose values as determined using the GlucoWatch biographer in clinic and home settings.


Subject(s)
Blood Glucose Self-Monitoring/instrumentation , Blood Glucose Self-Monitoring/methods , Diabetes Mellitus, Type 1/blood , Adult , Capillaries , Equipment Design , Female , Fingers/blood supply , Humans , Male , Regression Analysis , Reproducibility of Results