Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Anesth Analg ; 93(2): 345-7 , 3rd contents page, 2001 Aug.
Article in English | MEDLINE | ID: mdl-11473857

ABSTRACT

IMPLICATIONS: Significant neuromuscular block may be present in patients who have received vecuronium for days.


Subject(s)
Neuromuscular Junction/drug effects , Neuromuscular Nondepolarizing Agents/pharmacology , Vecuronium Bromide/pharmacology , Child, Preschool , Humans , Larynx/surgery , Male , Time Factors , Trachea/surgery , Vecuronium Bromide/metabolism
2.
Anesth Analg ; 91(6): 1381-8, 2000 Dec.
Article in English | MEDLINE | ID: mdl-11093984

ABSTRACT

Work of breathing (WOB) increases during general anesthesia in adults, but such information has been limited in pediatric patients. We studied WOB in 24 healthy children (mean age 2+/-1.9 yrs), during elective urogenital surgery under 1 minimum alveolar anesthetic concentration halothane-nitrous oxide anesthesia with a caudal block while breathing spontaneously. WOB was measured with an esophageal balloon, miniature flowmeter, and a computerized (Bicore) system. In each patient, WOB was computed under four conditions: a mask without oral airway (-AW), a mask with oral airway (+AW), a laryngeal mask airway (LMA), and an endotracheal tube (ETT). With each apparatus WOB was studied both with continuous positive airway pressure (CPAP) (5-6 cm H(2)O) and without CPAP (or zero end-expiratory pressure [ZEEP]). Under ZEEP, WOB (g x cm/kg) among the four apparatus were (mean +/- SEM): mask (-AW) (64 +/-19.2) > mask (+AW) (44+/-17.2), LMA (42+/-15.6) > ETT (25.4+/- 12.4) (P<0.05). WOB with CPAP significantly (P<0.05) decreased from WOB with ZEEP in three groups (mask [-AW], mask [+AW], and LMA), but not in the ETT group. Tidal volume (both ZEEP and CPAP) and end-tidal PCO(2) (with CPAP only) were significantly (P<0.05) decreased only in the ETT group, whereas no significant difference was found in respiratory rate or minute volume among the four airway apparatus groups, either with or without CPAP. The reduction in WOB, when breathing through ETT was primarily attributable to decreases in tidal volume and volume work. The finding that WOB decreases with CPAP in all groups except for the ETT group suggests that the decrease is a result of improved patency of the upper airway rather than of increases in functional residual capacity and lung compliance.


Subject(s)
Anesthesia, Inhalation , Intubation, Intratracheal , Laryngeal Masks , Respiratory Mechanics/physiology , Work of Breathing , Blood Gas Analysis , Blood Pressure/physiology , Child, Preschool , Female , Heart Rate/physiology , Humans , Infant , Male , Positive-Pressure Respiration , Urogenital Surgical Procedures
SELECTION OF CITATIONS
SEARCH DETAIL