Circulation ; 149(22): e1223-e1238, 2024 May 28.
Article En | MEDLINE | ID: mdl-38660790

Tricuspid valve disease is an often underrecognized clinical problem that is associated with significant morbidity and mortality. Unfortunately, patients will often present late in their disease course with severe right-sided heart failure, pulmonary hypertension, and life-limiting symptoms that have few durable treatment options. Traditionally, the only treatment for tricuspid valve disease has been medical therapy or surgery; however, there have been increasing interest and success with the use of transcatheter tricuspid valve therapies over the past several years to treat patients with previously limited therapeutic options. The tricuspid valve is complex anatomically, lying adjacent to important anatomic structures such as the right coronary artery and the atrioventricular node, and is the passageway for permanent pacemaker leads into the right ventricle. In addition, the mechanism of tricuspid pathology varies widely between patients, which can be due to primary, secondary, or a combination of causes, meaning that it is not possible for 1 type of device to be suitable for treatment of all cases of tricuspid valve disease. To best visualize the pathology, several modalities of advanced cardiac imaging are often required, including transthoracic echocardiography, transesophageal echocardiography, cardiac computed tomography, and cardiac magnetic resonance imaging, to best visualize the pathology. This detailed imaging provides important information for choosing the ideal transcatheter treatment options for patients with tricuspid valve disease, taking into account the need for the lifetime management of the patient. This review highlights the important background, anatomic considerations, therapeutic options, and future directions with regard to treatment of tricuspid valve disease.


American Heart Association , Tricuspid Valve , Humans , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/pathology , United States , Heart Valve Diseases/therapy , Heart Valve Diseases/diagnostic imaging , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/therapy , Heart Valve Prosthesis Implantation
3.
Article En | MEDLINE | ID: mdl-38670866

BACKGROUND: Aortic valve lithotripsy can fragment aortic valve calcium deposits and potentially restore leaflet pliability in animal model and ex-vivo, but clinical data is limited. Transcatheter aortic valve implantation (TAVR) might not be feasible as an urgent procedure in critically ill patients. Balloon valvuloplasty has the major limitation of valve recoil and inducing aortic regurgitation. AIMS: To determine the clinical feasibility of aortic valve lithotripsy-facilitated balloon valvuloplasty in patients with severe aortic stenosis unsuitable for valvular replacement. METHODS: We performed lithotripsy as adjunctive therapy to balloon aortic valvuloplasty in ten consecutive patients, most of whom were deemed unfit for TAVR. Lithotripsy of the aortic valve was performed with simultaneous inflation of one to three peripheral lithotripsy balloons to deliver ultrasound pulses. Rapid pacing was not used during lithotripsy. Aortic valve velocity, gradient, and valve area were measured before and after the procedure by echocardiogram. Transvalvular pressure gradient was recorded intra-procedurally. Periprocedural and ninety-day clinical outcomes were followed. RESULTS: Procedure was technically successful in 9 out of 10 patients and aborted in one patient due to cardiogenic shock. One patient had femoral closure device related complication. There was a statistically significant decrease in valvular gradient and increase in aortic valve area. 9 out of 10 patients recovered from acute episode and were discharged. 6 patients had improvement in NYHA class. 4 patients were subsequently able to receive TAVR. 90-day mortality occurred in 3 patients. There was no stroke or bradyarrhythmia peri-procedurally and no heart failure hospitalization at 90 days. CONCLUSION: Aortic valve lithotripsy-facilitated balloon valvuloplasty has reasonable feasibility, safety and technical reproducibility and acute clinical result. Hemodynamic effect is similar to that of balloon valvuloplasty reported in the literature. Subsequent Prognosis is not altered in critically ill patients.

4.
Catheter Cardiovasc Interv ; 103(6): 1023-1034, 2024 May.
Article En | MEDLINE | ID: mdl-38639143

BACKGROUND: The clinical efficacy and safety of alcohol septal ablation (ASA) for obstructive hypertrophic cardiomyopathy (HCM) have been well-established; however, less is known about outcomes in patients undergoing preemptive ASA before transcatheter mitral valve replacement (TMVR). AIMS: The goal of this study is to characterize the procedural characteristics and examine the clinical outcomes of ASA in both HCM and pre-TMVR. METHODS: This retrospective study compared procedural characteristics and outcomes in patient who underwent ASA for HCM and TMVR. RESULTS: In total, 137 patients were included, 86 in the HCM group and 51 in the TMVR group. The intraventricular septal thickness (mean 1.8 vs. 1.2 cm; p < 0.0001) and the pre-ASA LVOT gradient (73.6 vs. 33.8 mmHg; p ≤ 0.001) were higher in the HCM group vs the TMVR group. The mean volume of ethanol injected was higher (mean 2.4 vs. 1.7 cc; p < 0.0001). The average neo-left ventricular outflow tract area increased significantly after ASA in the patients undergoing TMVR (99.2 ± 83.37 mm2 vs. 196.5 ± 114.55 mm2; p = <0.0001). The HCM group had a greater reduction in the LVOT gradient after ASA vs the TMVR group (49.3 vs. 18 mmHg; p = 0.0040). The primary composite endpoint was higher in the TMVR group versus the HCM group (50.9% vs. 25.6%; p = 0.0404) and had a higher incidence of new permanent pacemaker (PPM) (25.5% vs. 18.6%; p = 0.3402). The TMVR group had a higher rate of all-cause mortality (9.8% vs. 1.2%; p = 0.0268). CONCLUSIONS: Preemptive ASA before TMVR was performed in patients with higher degree of clinical comorbidities, and correspondingly is associated with worse short-term clinical outcomes in comparison to ASA for HCM patients. ASA before TMVR enabled percutaneous mitral interventions in a small but significant minority of patients that would have otherwise been excluded. The degree of LVOT and neoLVOT area increase is significant and predictable.


Ablation Techniques , Cardiac Catheterization , Cardiomyopathy, Hypertrophic , Ethanol , Heart Valve Prosthesis Implantation , Mitral Valve , Humans , Retrospective Studies , Male , Ethanol/administration & dosage , Ethanol/adverse effects , Cardiomyopathy, Hypertrophic/diagnostic imaging , Cardiomyopathy, Hypertrophic/mortality , Cardiomyopathy, Hypertrophic/therapy , Cardiomyopathy, Hypertrophic/surgery , Cardiomyopathy, Hypertrophic/physiopathology , Female , Treatment Outcome , Ablation Techniques/adverse effects , Ablation Techniques/mortality , Aged , Cardiac Catheterization/adverse effects , Cardiac Catheterization/mortality , Cardiac Catheterization/instrumentation , Middle Aged , Risk Factors , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/mortality , Time Factors , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Mitral Valve/surgery , Recovery of Function , Aged, 80 and over , Heart Septum/diagnostic imaging , Heart Septum/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/mortality
7.
Cardiovasc Revasc Med ; 62: 105-118, 2024 May.
Article En | MEDLINE | ID: mdl-38212236

BACKGROUND: Percutaneous closure of aortic and ventricular pseudoaneurysms (PSA) has only been reported on a case report and series basis. In previous case reports, percutaneous closure has been performed successfully in patients of prohibitive surgical risk. This case series aims to show feasibility of percutaneous closure of aortic and ventricular pseudoaneurysm secondary to perivalvular leak (PVL) in a small patient population and the utility of multimodality imaging as an integral tool in procedural planning. This is the largest complex case series to date describing the feasibility and success rate of complex PSA closure, with a follow-up period of up to 4 years. MATERIAL AND METHODS: We performed institutional review and systemic literature review to identify all paravalvular leak cases with associated pseudoaneurysm formation for which a closure procedure was performed. Ten patients were identified. Pooled analysis for cases from institutional review (n = 10) and systemic literature review (n = 39) was performed. The success rate was 100 %. At 30-days, the mortality was 0 %. CONCLUSION: In paravalvular leak patients with subsequent pseudoaneurysm formation, exhaustive imaging evaluation is required for closure. However, it can be achievable with favorable rates of success.


Aneurysm, False , Heart Valve Prosthesis Implantation , Humans , Aneurysm, False/diagnostic imaging , Aneurysm, False/etiology , Aneurysm, False/therapy , Male , Female , Treatment Outcome , Aged , Middle Aged , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Aneurysm/diagnostic imaging , Heart Aneurysm/etiology , Heart Aneurysm/therapy , Cardiac Catheterization/adverse effects , Aortic Aneurysm/diagnostic imaging , Aortic Aneurysm/surgery , Time Factors , Aged, 80 and over , Heart Valve Prosthesis , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Echocardiography, Transesophageal , Adult
9.
Echocardiography ; 40(11): 1285-1291, 2023 11.
Article En | MEDLINE | ID: mdl-37842844

Left ventricular pseudoaneurysm (PSA) after surgical aortic valve replacement (AVR) is a known but uncommon complication. It is associated with risks such as thromboembolism and life-threatening rupture. Surgical repair has traditionally been utilized in low-risk patients but transcatheter closure has become a promising therapeutic option. This case report describes the utility of multimodality imaging in pre-, intra-, and post-procedural evaluation of transcatheter PSA closure and is among the first to demonstrate the utility of 3D print model.


Aneurysm, False , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Humans , Aneurysm, False/diagnostic imaging , Aneurysm, False/surgery , Cardiac Catheterization/methods , Heart Valve Prosthesis Implantation/adverse effects , Aortic Valve/surgery , Transcatheter Aortic Valve Replacement/methods , Multimodal Imaging , Treatment Outcome
10.
Echocardiography ; 40(8): 884-887, 2023 08.
Article En | MEDLINE | ID: mdl-37319117

Pacer wire induced tricuspid regurgitation is not well-understood. The mechanisms behind pacer wired induced tricuspid regurgitation have not been clearly defined. This clinical vignette sets to identify different technical mechanisms behind cardiac lead induced tricuspid regurgitation to help optimize cardiac lead implantation strategies for future device implantation.


Cardiac Catheterization , Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Tricuspid Valve , Humans , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/surgery , Treatment Outcome , Echocardiography, Three-Dimensional , Tomography, X-Ray Computed
12.
JACC Cardiovasc Interv ; 16(16): 1953-1960, 2023 08 28.
Article En | MEDLINE | ID: mdl-37212431

BACKGROUND: Transcatheter treatment of patients with native aortic valve regurgitation (AR) has been limited by anatomical factors. No transcatheter device has received U.S. regulatory approval for the treatment of patients with AR. OBJECTIVES: The aim of this study was to describe the compassionate-use experience in North America with a dedicated transcatheter device (J-Valve). METHODS: A multicenter, observational registry was assembled of compassionate-use cases of J-Valve implantation for the treatment of patients with severe symptomatic AR and elevated surgical risk in North America. The J-Valve consists of a self-expanding Nitinol frame, bovine pericardial leaflets, and a valve-locating feature. The available size matrix (5 sizes) can treat a wide range of anatomies (minimum and maximum annular perimeters 57-104 mm). RESULTS: A total of 27 patients (median age 81 years [IQR: 72-85 years], 81% at high surgical risk, 96% in NYHA functional class III or IV) with native valve AR were treated with the J-Valve during the study period (2018-2022). Procedural success (J-Valve delivered to the intended location without the need for surgical conversion or a second transcatheter heart valve) was 81% (22 of 27 cases) in the overall experience and 100% in the last 15 cases. Two cases required conversion to surgery in the early experience, leading to changes in valve design. At 30 days, there was 1 death, 1 stroke, and 3 new pacemakers (13%), and 88% of patients were in NYHA functional class I or II. No patient had residual AR of moderate or greater degree at 30 days. CONCLUSIONS: The J-Valve appears to provide a safe and effective alternative to surgery in patients with pure AR and elevated or prohibitive surgical risk.


Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Animals , Cattle , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , Heart Valve Prosthesis/adverse effects , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Prosthesis Design , Aortic Valve Stenosis/surgery , Risk Factors
13.
Cardiovasc Revasc Med ; 53: 1-7, 2023 08.
Article En | MEDLINE | ID: mdl-37012106

BACKGROUND/PURPOSE: Percutaneous valve interventions for aortic stenosis (AS) include transcatheter aortic valve replacement (TAVR) and balloon aortic valvuloplasty (BAV). Intraprocedural mechanical circulatory support (MCS) with Impella devices (Abiomed, Danvers, MA) is used in select high-risk patients, although data regarding its efficacy is limited. This study sought to evaluate the clinical outcomes of Impella use in patients with AS who underwent TAVR and BAV at a quaternary-care center. METHODS/MATERIALS: All patients with severe AS who underwent TAVR and BAV with Impella between 2013 and 2020 were included. Patient demographics, outcomes, complications, and 30-day mortality data was analyzed. RESULTS: Over the study period 2680 procedures were performed, 1965 TAVR and 715 BAV. 120 utilized Impella support, 26 TAVR and 94 BAV. Among TAVR Impella cases, justifications for MCS included cardiogenic shock (53.9 %), cardiac arrest (19.2 %), and coronary occlusion (15.4 %). Among BAV Impella cases, justifications for MCS included cardiogenic shock (55.3 %) and protected percutaneous coronary intervention (43.6 %). The 30-day mortality rate in TAVR Impella was 34.6 % and in BAV Impella was 28 %. BAV Impella cases involving cardiogenic shock had a higher rate of 45 %. Impella remained in-use past 24 h from the procedure in 32.2 % cases. Vascular access-related complications occurred in 4.8 % cases and bleeding complications occurred in 1.5 % cases. Conversion to open-heart surgery occurred in 0.7 % cases. CONCLUSIONS: MCS is an option for high-risk patients with severe AS who require TAVR and BAV. Despite hemodynamic support, the 30-day mortality rate remained high especially in cases where support was employed for cardiogenic shock.


Aortic Valve Stenosis , Balloon Valvuloplasty , Transcatheter Aortic Valve Replacement , Humans , Shock, Cardiogenic/diagnosis , Shock, Cardiogenic/therapy , Shock, Cardiogenic/complications , Treatment Outcome , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Hemodynamics , Aortic Valve/diagnostic imaging , Aortic Valve/surgery
14.
Catheter Cardiovasc Interv ; 101(1): 164-169, 2023 01.
Article En | MEDLINE | ID: mdl-36378598

Aspiration thrombectomy with the AngioVac is approved for percutaneous removal of thrombus in the venous system. While not approved for aspiration of thrombus or other mass in the left heart or arterial system, it has been used in that setting. Patients with left heart or arterial mass are often deemed unfavorable for surgery and treated conservatively. This may not be the best option for all patients, as some may have lesions that represent a short-term increased risk of complications, for which intervention and aspiration could be considered reasonable. Unfortunately, femoral arteries sizes often cannot accommodate the Angiovac current aspiration cannula dimensions. Here, we demonstrated trans-caval approach for aspiration thrombectomy of extensive aortic mobile plaque and thrombus.


Plaque, Atherosclerotic , Thrombosis , Humans , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Treatment Outcome , Thrombosis/diagnostic imaging , Thrombosis/etiology , Thrombosis/surgery , Thrombectomy/adverse effects
17.
Catheter Cardiovasc Interv ; 100(4): 628-635, 2022 10.
Article En | MEDLINE | ID: mdl-35900207

OBJECTIVES: To study the safety and efficacy of AngioVac for left-sided transcatheter vacuum-assisted mass extraction (TVME). BACKGROUND: The AngioVac system is approved for right-sided TVME and has emerged as an effective and safe alternative for open surgical treatment. The use of the AngioVac device for aspiration of left-sided TVME has been limited. METHODS: Consecutive patients from two Michigan centers who underwent left-sided TVME were included. Data on patient demographics, procedural information, in-hospital and follow-up events were collected through electronic medical records review. Technical success was defined as aspirating of 70%-100% of the material. RESULTS: Ten patients (mean age 58.3 [±17.3] years, 50% male) were included. Indications for TMVE were in large for recurrent embolic events. All patients underwent bilateral cerebro-embolic protection using the Sentinel device. The total mean procedure time was 192.5 (±47.5) min of which the meantime for active aspiration (bypass time) was 9.3 (±4.2) min. The circuit configuration was: arteriovenous (AV) in four cases and arterioarterial (AA) in six cases. Successful aspiration was achieved in 80% of cases. No complications were reported (range follow-up 1-16 months). CONCLUSIONS: Our small case series demonstrates the feasibility and safety of the AngioVac system in left-sided mass extraction. Larger trials are needed to further demonstrate its effectiveness and safety and potentially apply for on-label use.


Thrombectomy , Female , Humans , Male , Michigan , Middle Aged , Thrombectomy/adverse effects , Treatment Outcome , Vacuum
18.
Cardiovasc Revasc Med ; 45: 44-50, 2022 12.
Article En | MEDLINE | ID: mdl-35882600

INTRODUCTION: Acute MR due to mechanical mitral valve (MV) complications frequently results in cardiogenic shock and requires emergency surgical intervention. There was limited evidence for alternative treatment like MitraClip for patients at prohibitive surgical risk. We aimed to study the technical features and outcomes of emergency transcatheter edge-to-edge repair (TEER) using the MitraClip system for patients with cardiogenic shock (CS) secondary to acute mitral regurgitation (MR) and mechanical MV complication. MATERIAL AND METHODS: We performed institutional review and systemic literature review to identify all TEER for CS patients due to acute mitral regurgitation and mechanical MV complication. Clinical endpoints included device success rate assessed at the end of procedure, ability to wean off MCS, all-cause and cardiovascular mortality at 30-day. RESULTS: Eight patients were identified from institutional review. Detail anatomical analysis found that patients with mechanical MV complications related to myocardial infarction had a lower transseptal height achieved during MitraClip (3.6 ± 0.1 cm vs 4.3 ± 0.3 cm, p = 0.03) than those not related. Pooled analysis for cases from institutional review (n = 8) and systemic literature review (n = 16) was performed. The device success rate was 68.8 %. Seventy-five percent (n = 18) cases required mechanical circulatory support (MCS), and 94.4 % were able to wean off MCS. At 30-day, the cardiovascular mortality was 4.5 % and the all-cause mortality was 9.1 %. CONCLUSIONS: In CS patients due to acute MR and mechanical MV complications, TEER with/without MCS was feasible with a reasonable device success rate.


Shock, Cardiogenic , Humans , Shock, Cardiogenic/diagnosis , Shock, Cardiogenic/etiology , Shock, Cardiogenic/therapy
19.
J Neurosurg Case Lessons ; 3(22): CASE21654, 2022 May 30.
Article En | MEDLINE | ID: mdl-35734610

BACKGROUND: Ventriculoatrial (VA) shunt disconnection can result in distal catheter migration into the cardiopulmonary vasculature. There is little guidance in the current literature on how to prevent and manage this uncommon yet potentially serious complication. The authors reviewed the existing literature and described three instances of distal shunt migration VA shunts and offered insight on methods to mitigate such complications. OBSERVATIONS: Eighteen patients were identified with VA shunts. Of these patients, seven were identified as having a connector in the neck, three of which were associated with distal disconnection and migration. In all three cases, the distal catheter was retrieved via an endovascular approach in conjunction with transesophageal echocardiography to assess for retrieval feasibility. LESSONS: The authors recommended the avoidance of a straight connector when performing VA shunt placement. When distal catheter migration occurs, collaboration with interventional cardiology is advisable when possible.

20.
Catheter Cardiovasc Interv ; 100(1): 163-168, 2022 07.
Article En | MEDLINE | ID: mdl-35568977

OBJECTIVE: We aim to report on the efficacy and safety of large bore venous access (LBVA) preclosure with Perclose™ (Abbott Vascular Devices) suture-mediated device use following transcatheter edge-to-edge (TEER) and replacement (TMVR). BACKGROUND: Patients requiring TEER and TMVR require LBVA. Clinical outcome data on the use of suture-mediated devices for LBVA site closure are limited. METHODS: Between 2012 and 2019, 354 consecutive high-risk patients with mitral valvular heart disease underwent TEER (n = 287) with MitraClip and TMVR (n = 67) with Edwards Sapien Valves. Patients had LBVA with 24 or 16 French sheaths. All patients underwent preclosure of LBVA except for one that underwent manual hemostasis. RESULTS: There were no closure device failures. None of the cases required surgical repair of the access site following venous preclosure. Two cases had large hematomas (>6 cm) following Perclose in each group. Six cases had small hematomas (<6 cm and >2 cm) with three in each group. There was one major bleeding using Mitral Valve Academic Research Consortium 2 definition (retroperitoneal bleed from arterial puncture) unrelated to the venous closure. Transfusion related to vascular access complication was required in five cases. There were two immediate acute deep venous thromboses postprocedure; one of which occurred after preclosure. There were no arteriovenous malformations, pseudoaneurysms, or access site infections reported following Perclose. CONCLUSION: In this large sample size analysis, Proglide preclosure technique is a feasible and safe alternative approach to achieving hemostasis after removal of LBVA sheaths in patients undergoing TEER and TMVR. Randomized trials are needed to compare the different modalities of hemostasis.


Heart Valve Diseases , Vascular Closure Devices , Heart Valve Diseases/surgery , Hematoma/etiology , Hemorrhage/etiology , Hemorrhage/prevention & control , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Suture Techniques/adverse effects , Treatment Outcome , Vascular Closure Devices/adverse effects
...