JACC cardiovasc. interv ; 11(7): 633-644, Apr. 2018. tab, graf
Article in English | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1223701

ABSTRACT

OBJECTIVES: The aim of this study was to identify independent correlates of very late scaffold thrombosis (VLST) from an analysis of consecutively treated patients from 15 multicenter studies. BACKGROUND: Recent analyses suggest an increased risk for VLST with the Absorb Bioresorbable Vascular Scaffold compared with drug-eluting stents, but insights as to correlates of risk are limited. METHODS: A total of 55 patients were identified with scaffold thrombosis. They were matched 2:1 with control subjects selected randomly from patients without thrombosis from the same study. Quantitative coronary angiography was available for 96.4% of patients. Multiple logistic and Cox regression analysis were used to identify significant independent outcome correlates from 6 pre-specified characteristics. RESULTS: Patients had scaffold thrombosis at a median of 20 months (interquartile range: 17 to 27 months). Control subjects were followed for 36 months (interquartile range: 24 to 38 months). For the combined groups, reference vessel diameter (RVD) was 2.84 0.50 mm, scaffold length was 26 16 mm, and post-dilatation was performed in56%. Univariate correlates of thrombosis were smaller nominal scaffold/RVD ratio (linear p»0.001; ratio<1.18:1; odds ratio: 7.5; p»0.002) and larger RVD (linear p»0.001;>2.72 mm; odds ratio: 3.4; p»0.001). Post-dilatation at$16 atm, post-dilatation balloon/scaffold ratio, final percentage stenosis, and dual antiplatelet therapy were not correlated with VLST. Only scaffold/RVD ratio remained a significant independent correlate of VLST (p»0.001), as smaller ratio was correlated with RVD (p<0.001). Post hoc analysis of 8 other potential covariates revealed no other correlates of outcome. CONCLUSIONS: In the present analysis, the largest to date of its type, relative scaffold undersizing was the strongest determinant of VLST. Given current understanding of "scaffold dismantling," this finding likely has ramifications for all bioresorbable scaffolds.


Subject(s)
Thrombosis , Coronary Angiography , Drug-Eluting Stents
2.
JACC Cardiovasc Interv ; 10(18): 1809-1815, 2017. graf, tab
Article in English | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1064020

ABSTRACT

OBJECTIVES: The authors sought to identify and verify independent correlates of device thrombosis from an analysis of multicenter trials and registries. BACKGROUND: Recent analyses suggest an increased risk of device thrombosis with Absorb bioresorbable vascular scaffold (Abbott Vascular, Santa Clara, California) implantation compared with metallic drug-eluting stents, and data from moderate size studies suggest a risk relationship to vessel size and technique. METHODS: From 8,771 consecutively treated patients, 105 patients (1.2%) were identified with scaffold thrombosis within 1 year of implantation. They were matched 2:1 with controls selected randomly from nonthrombosis patients. Data-restricted multiple logistic analysis was used to identify significant independent covariates of the outcome. RESULTS: Early (within 1 month) scaffold thrombosis occurred in 69 patients and late (1 to 12 months) thrombosis occurred in 36 patients. Modelling found significant correlations of thrombosis to be final minimal lumen diameter 1.1:1 balloon/scaffold ratio (OR: 2.3; p = 0.022), and reference vessel diameter <2.40 mm (OR: 2.1; p = 0.036).CONCLUSIONS:Suboptimal vessel sizing, procedural technique, angiographic outcomes, and dual antiplatelet therapy discontinuation appear to be the principal determinants of Absorb scaffold thrombosis risk through 12 months after implantation.


Subject(s)
Drug-Eluting Stents , Thrombosis , Blood Vessels