ABSTRACT
In order to overcome the poor adhesion of zirconia-silica coating electrophoretically deposited on 316 L stainless steel, graphene oxide (GO) was used as an interlayer. The effect of this interlayer on morphological, microstructural, corrosion performance and bioactivity behavior of ZrO2-10 at. % SiO2 coating was studied. The zirconia-silica coating with the GO interlayer revealed a higher barrier performance as a more compact and a greater adhesive layer to the substrate was created. Indeed, the GO interlayer led to an improvement in apatite formation on zirconia-silica coating surface probably due to create higher roughness. Briefly, the GO interlayer was effective on enhancement of electrochemical performance and biological property of zirconia-silica composite coating, making it a suitable candidate for biomaterials applications.
Subject(s)
Silicon Dioxide , Stainless Steel , Coated Materials, Biocompatible , Corrosion , Graphite , Surface PropertiesABSTRACT
The aim of this study was to combine micro-arc oxidation (MAO) and self-assembly technique to improve corrosion resistivity of AZ91 alloy. While a silicate-fluoride electrolyte was adopted for MAO treatment, polyethylenimine (PEI)/kappa carrageenan (KC) self-assembly coating was applied as the second coating layer. Resulted demonstrated the formation of forsterite-fluoride containing MAO coating on AZ91 alloy depending on the voltage and time of anodizing process. Addition of the second PEI/KC coating layer on MAO treated sample effectively enhanced the adhesive strength of MAO coated sample due to filling the pores with polymers and increase in the mechanical interlocking of coating to the substrate. Moreover, the corrosion evaluation considered by potentiodynamic polarization and electrochemical impedance spectroscopy confirmed that double layered PEI/KC:MAO coating presented superior resistance to corrosion attack. It is envisioned that the proposed double layered PEI/KC:MAO coating could be useful for biomedical applications.
ABSTRACT
In this study, biodegradation and biocompatibility of novel poly(ε-caparolactone)/nano fluoridated hydroxyapatite (PCL-FHA) scaffolds were investigated. The FHA nanopowders were prepared via mechanical alloying method and had a chemical composition of Ca(10)(PO(4))(6)OH(2-x )F(x) (where x values were selected equal to 0.5 and 2.0). In order to fabricate PCL-FHA scaffolds, 10, 20, 30 and 40 wt% of the FHA were added to the PCL. The PCL-FHA scaffolds were produced by the solvent casting/particulate leaching using sodium chloride particles (with diameters of 300-500 µm) as the porogen. The phase structure, microstructure and morphology of the scaffolds were evaluated using X-ray diffraction, Fourier transform infrared spectroscopy and scanning electron microscopy techniques. Porosity of the scaffolds was measured using the Archimedes' Principle. In vitro degradation of PCL-FHA scaffolds was studied by incubating the samples in phosphate buffered saline at 37°C and pH 7.4 for 30 days. Moreover, biocompatibility was evaluated by MTT assay after seeding and culture of osteoblast-like cells on the scaffolds. Results showed that the osteoblast-like cells attached to and proliferated on PCL-FHA and increasing the porosity of the scaffolds increased the cell viability. Also, degradation rate of scaffolds were increased with increasing the fluorine content in scaffolds composition.