Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters











Database
Language
Publication year range
1.
JGH Open ; 8(9): e70018, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39253018

ABSTRACT

Background and Aims: The utilization of artificial intelligence (AI) with computer-aided detection (CADe) has the potential to increase the adenoma detection rate (ADR) by up to 30% in expert settings and specialized centers. The impact of CADe on serrated polyp detection rates (SDR) and academic trainees ADR & SDR remains underexplored. We aim to investigate the effect of CADe on ADR and SDR at an academic center with various levels of providers' experience. Methods: A single-center retrospective analysis was conducted on asymptomatic patients between the ages of 45 and 75 who underwent screening colonoscopy. Colonoscopy reports were reviewed for 3 months prior to the introduction of GI Genius™ (Medtronic, USA) and 3 months after its implementation. The primary outcome was ADR and SDR with and without CADe. Results: Totally 658 colonoscopies were eligible for analysis. CADe resulted in statistically significant improvement in SDR from 8.92% to 14.1% (P = 0.037). The (ADR + SDR) with CADe and without CADe was 58% and 55.1%, respectively (P = 0.46). Average colonoscopy (CSC) withdrawal time was 17.33 min (SD 10) with the device compared with 17.35 min (SD 9) without the device (P = 0.98). Conclusion: In this study, GI Genius™ was associated with a statistically significant increase in SDR alone, but not in ADR or (ADR + SDR), likely secondary to the more elusive nature of serrated polyps compared to adenomatous polyps. The use of CADe did not affect withdrawal time.

SELECTION OF CITATIONS
SEARCH DETAIL