Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS Negl Trop Dis ; 16(2): e0010241, 2022 02.
Article in English | MEDLINE | ID: mdl-35196321

ABSTRACT

The laborious microscopic agglutination test (MAT) is the gold standard serologic test for laboratory diagnosis of leptospirosis. We developed EIA based serologic assays using recombinant proteins (rLigA, rLigB, rLipL32) and whole-cell extracts from eight Leptospira serovars as antigen and assessed the diagnostic performance of the new assay within each class, against MAT positive (MAT+) human sera panels from Portugal/PT (n = 143) and Angola/AO (n = 100). We found that a combination of recombinant proteins rLigA, rLigB and rLipL32 correctly identified antigen-specific IgG from patients with clinical and laboratory confirmed leptospirosis (MAT+) with 92% sensitivity and ~ 97% specificity (AUC 0.974) in serum from the provinces of Luanda (LDA) and Huambo (HBO) in Angola. A combination of whole cell extracts of L. interrogans sv Copenhageni (LiC), L. kirschneri Mozdok (LkM), L. borgpetersenii Arborea (LbA) and L. biflexa Patoc (LbP) accurately identified patients with clinical and laboratory confirmed leptospirosis (MAT+) with 100% sensitivity and ~ 98% specificity for all provinces of Angola and Portugal (AUC: 0.997 for AO/LDA/HBO, 1.000 for AO/HLA, 0.999 for PT/AZ and 1.000 for PT/LIS). Interestingly, we found that MAT+ IgG+ serum from Angola had a significantly higher presence of IgD and that IgG3/IgG1 isotypes were significantly increased in the MAT+ IgG+ serum from Portugal. Given that IgM/IgD class and IgG3/IgG1 specific isotypes are produced in the earliest course of infection, immunoglobulin G isotyping may be used to inform diagnosis of acute leptospirosis. The speed, ease of use and accuracy of EIA tests make them excellent alternatives to the laborious and expensive MAT for screening acute infection in areas where circulating serovars of pathogenic Leptospira are well defined.


Subject(s)
Leptospira , Leptospirosis , Acute Disease , Agglutination Tests , Antibodies, Bacterial , Antigens, Bacterial , Cell Extracts , Enzyme-Linked Immunosorbent Assay , Humans , Immunoenzyme Techniques , Immunoglobulin D , Immunoglobulin G , Recombinant Proteins , Serologic Tests
2.
Microorganisms ; 9(8)2021 Aug 17.
Article in English | MEDLINE | ID: mdl-34442837

ABSTRACT

Enteroviruses (EVs) from the D species are the causative agents of a diverse range of infectious diseases in spite of comprising only five known members. This small clade has a diverse host range and tissue tropism. It contains types infecting non-human primates and/or humans, and for the latter, they preferentially infect the eye, respiratory tract, gastrointestinal tract, and nervous system. Although several Enterovirus D members, in particular EV-D68, have been associated with neurological complications, including acute myelitis, there is currently no effective treatment or vaccine against any of them. This review highlights the peculiarities of this viral species, focusing on genome organization, functional elements, receptor usage, and pathogenesis.

3.
PLoS Negl Trop Dis ; 14(1): e0007950, 2020 01.
Article in English | MEDLINE | ID: mdl-31905198

ABSTRACT

The goal of this study was to characterize how natural routes of infection affect the kinetics of pathogenic Leptospira dissemination to blood and kidney. C3H/HeJ mice were sublethally infected with L. interrogans serovar Copenhageni FioCruz L1-130 (Leptospira) through exposure of a dermis wound and through oral and nasal mucosa, in comparison to uninfected mice and to mice infected via standard intraperitoneal inoculation. In striking contrast to oral mucosa inoculation, transdermal and nasal mucosa infections led to weight loss, renal colonization and inflammation, as previously observed for conjunctival and intraperitoneal infections. However, the timing at which Leptospira gained access to blood, as well as Leptospira' colonization of the kidney and shedding in urine, differed from intraperitoneal infection. Furthermore, a comparative analysis of transcription of pro-inflammatory mediators in kidney and total immunoglobulin isotyping in serum from infected mice, showed increased innate immune response markers (KC, MIP-2, TNF-α) and lower Th1 associated IFN-γ in kidney, as well as lower Th1 associated IgG2a in mice infected through the nasal mucosa as compared to intraperitoneal infection. We conclude that the route of infection affects the timing at which Leptospira gains access to blood for dissemination, as well as the dynamics of colonization and inflammation of the kidney.


Subject(s)
Leptospira interrogans/physiology , Leptospirosis/microbiology , Leptospirosis/transmission , Animals , Immunity, Innate , Immunoglobulins/blood , Kinetics , Leptospira interrogans/immunology , Leptospirosis/immunology , Mice, Inbred C3H , Mouth Mucosa , Nasal Mucosa , Nephritis/immunology , Nephritis/microbiology , Nephritis/pathology , Skin/injuries , Skin/microbiology , Urine/microbiology
4.
J Clin Microbiol ; 57(12)2019 12.
Article in English | MEDLINE | ID: mdl-31597750

ABSTRACT

Single multiplexed assays could replace the standard 2-tiered (STT) algorithm recommended for the laboratory diagnosis of Lyme disease if they perform with a specificity and a sensitivity superior or equal to those of the STT algorithm. We used human serum rigorously characterized to be sera from patients with acute- and convalescent-phase early Lyme disease, Lyme arthritis, and posttreatment Lyme disease syndrome, as well as the necessary controls (n = 241 samples), to select the best of 12 Borrelia burgdorferi proteins to improve our microfluidic assay (mChip-Ld). We then evaluated its serodiagnostic performance in comparison to that of a first-tier enzyme immunoassay and the STT algorithm. We observed that more antigens became positive as Lyme disease progressed from early to late stages. We selected three antigens (3Ag) to include in the mChip-Ld: VlsE and a proprietary synthetic 33-mer peptide (PepVF) to capture sensitivity in all disease stages and OspC for early Lyme disease. With the specificity set at 95%, the sensitivity of the mChip-Ld with 3Ag ranged from 80% (95% confidence interval [CI], 56% to 94%) and 85% (95% CI, 74% to 96%) for two panels of serum from patients with early Lyme disease and was 100% (95% CI, 83% to 100%) for serum from patients with Lyme arthritis; the STT algorithm detected early Lyme disease in the same two panels of serum from patients with early Lyme disease with a sensitivity of 48.5% and 75% and Lyme arthritis in serum from patients with Lyme arthritis with a sensitivity of 100%, and the specificity was 97.5% to 100%. The mChip-Ld platform outperformed the STT algorithm according to sensitivity. These results open the door for the development of a single, rapid, multiplexed diagnostic test for point-of-care use that can be designed to identify the Lyme disease stage.


Subject(s)
Borrelia burgdorferi/immunology , Lyme Disease/diagnosis , Microfluidics/methods , Point-of-Care Systems , Serologic Tests/methods , Humans , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...