Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 2 de 2
1.
Sci Total Environ ; 912: 169441, 2024 Feb 20.
Article En | MEDLINE | ID: mdl-38123089

The water industry worldwide experiences numerous sewer blockages each year, partially attributed to the accumulation of fat, oil and grease (FOG). Managing this issue involves various strategies, including the requirement for installation of grease interceptors (GIs) installation. However, the claimed efficacy of commercial GIs of eliminating 99 % of FOG has been questioned for many years because FOG deposit formation occurs despite food service establishments (FSEs) using GIs, therefore detailed understanding of FOG wastewater compositions and its removal by GIs is required. This study provides an insight into the key FOG components such as FOG particle size, metals and fatty acid (FA) profile in GI influent and effluent, and within the GI, at three different FSEs. Analysis of FAs identified substantial proportions of extra-long-chain FAs in the effluents, including arachidic (C20:0), behenic (C22:0), mead (C20:3), lignoceric (C24:0), and nervonic (C24:1) acids. In contrast, the household kitchen released palmitic (C16:0), oleic (C18:1) and linoleic (C18:2) acids. It was further observed that scums effectively remove the larger FOG particles, leaving only 10 % below 75.4 µm. Notably, FSEs which employed automatic dishwashers produced up to 80.4 % of particles ≤45 µm, whereas FSEs and household kitchen which used handwash sinks generated only 36.9 % and 26.3 % of particles ≤45 µm, respectively. This study demonstrated that the commercial GIs do not remove FOG entirely but clearly demonstrated that they discharge high concentrations of FOG with extra-long FFAs which were attributed to the occurrence of microbial activity and hydrolysis of triglycerides within the GI, potentially contributing to FOG deposition.


Fats , Food Services , Macrolides , Sewage , Hydrocarbons/analysis
2.
Water Res ; 225: 119141, 2022 Oct 15.
Article En | MEDLINE | ID: mdl-36182671

Treatment of wastewater with high levels of fat, oil, and grease (FOG), produced by the growing number (annually 2%) of food service establishments (FSEs), is a major concern for water utilities. About 30-40% of sewer blockages are caused primarily by the formation of FOG deposits in sewer pipes, and an annual additional maintenance cost is required for sewer management. To manage FOG deposition, FSEs are required to recover the FOG at the point of generation by installing grease interceptors (GIs) before release to the sewer system. The successful control of FOG deposition is largely dependent on clear understanding of its complex properties, pre-treatment processes, deposition mechanism and public awareness. The objective of this study is to provide a comprehensive understanding of the physicochemical properties of FOG, including particle size distribution and their removal efficiencies by existing GIs. Nowadays, generation of FOG particles of ≤45 µm is increasing because of the increasing use of automatic dishwashers. Current hybrid processes which comprise pre-treatment prior to GI use are ineffective since they are unable to completely remove particle sizes of ≤45 µm. Hence, there is potential for these particles to be released into the sewer system and eventually cause blockages. This critical review discusses the characteristics of effluents, including the particle size distributions generated from automatic dishwashers and handwash sinks. It concludes by providing some case studies and a perspective of the future opportunities to develop a novel GI process integrated with pre-treatment to remove particles of all sizes, including colloidal particles.


Sewage , Wastewater , Sewage/chemistry , Fats/chemistry , Hydrocarbons , Water
...