Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
J Matern Fetal Neonatal Med ; 37(1): 2406344, 2024 Dec.
Article in English | MEDLINE | ID: mdl-39299776

ABSTRACT

BACKGROUND: Various techniques have been proposed to predict and evaluate the timing and conditions of childbirth in pregnant women at different stages of pregnancy. Providing precise methods for forecasting childbirth status can reduce the burden on the healthcare system. This study aimed to evaluate the predictive value of transvaginal sonography of cervical length (CL) and cervical angle (CA) on full-term delivery outcomes. METHODS: This cohort study analyzed 151 pregnant women between 37 and 42 weeks of gestational age who were treated at Rasoul Akram Hospital affiliated with Iran University of Medical Sciences from June 2023 to January 2024. All Participants received transvaginal examinations. This study evaluated the accuracy of CL and CA by transvaginal sonography in predicting outcomes like vaginal delivery, cesarean section, necessity for labor induction, and the rate of Premature Rupture of Membranes (PROM). The study used the Receiver Operating Characteristic (ROC) curve to determine the optimal cutoff for predicting birth outcomes. RESULTS: The mean age of the pregnant women was 28.9 ± 4.22 years, while the average duration of pregnancy was 39.8 ± 2.11 weeks. Cesarean delivery was performed on 45 individuals (29.8%) and 106 (70.1%) underwent vaginal delivery. The mean CL overall stood at 21.2 ± 6.4 mm. PROM was observed in 41 cases (27.1%) among full-term pregnancies. A significant difference was noted in mean CL between the cesarean and vaginal delivery groups (24.2 ± 2.4 vs. 20.1 ± 2.1 mm, p = 0.001). The predictive value of a CL measuring 21 mm for cesarean delivery was 72.2% sensitive and 79.1% specific. Similarly, a CL of 22 mm showed 66.6% sensitivity and 80.2% specificity for labor induction. Regarding PROM in full-term pregnancies, a CL assessment demonstrated 59.8% sensitivity and 69.1% specificity. Finally, a CA of 115.2° exhibited 70.3% sensitivity and 78.4% specificity in predicting vaginal delivery. CONCLUSION: The present study showed that evaluating CL and CA via transvaginal sonography demonstrated adequate diagnostic accuracy in predicting spontaneous birth, need for labor induction, cesarean delivery, and incidence of PROM in full-term pregnant women. This method is suggested to be an accurate and appropriate way to predict delivery results.


Subject(s)
Cervical Length Measurement , Cervix Uteri , Predictive Value of Tests , Humans , Female , Pregnancy , Adult , Cervical Length Measurement/methods , Cervix Uteri/diagnostic imaging , Cohort Studies , Ultrasonography, Prenatal/methods , Delivery, Obstetric/methods , Delivery, Obstetric/statistics & numerical data , Cesarean Section/statistics & numerical data , Labor, Induced/statistics & numerical data , Young Adult , Iran/epidemiology , Pregnancy Outcome/epidemiology , Fetal Membranes, Premature Rupture/diagnostic imaging , Fetal Membranes, Premature Rupture/epidemiology , ROC Curve , Term Birth
2.
Pediatr Dev Pathol ; 27(1): 45-51, 2024.
Article in English | MEDLINE | ID: mdl-37749056

ABSTRACT

INTRODUCTION: This study aimed to evaluate the potential value of placental anatomic features and various types of normal and abnormal cord insertion types in predicting adverse maternal-fetal outcomes in singleton pregnancies. We also tried to assess the association between these outcomes and various types of placental cord insertion. METHOD: This prospective observational study was performed on singleton pregnancies. For each patient placental features including diameter, thickness, type of cord insertion, and the shortest distance between the cord insertion point and placental edge were recorded. The relationship between these factors and the development of multiple adverse pregnancy outcomes including preterm labor, intrauterine fetal death (IUFD), and the rate of neonatal intensive care unit (NICU) admissions were evaluated and reported. RESULTS: Overall 308 patients were enrolled in the study. Smoker mothers had significantly smaller placentas (P-value = .008), and those with lower diameter placentas were more likely to suffer from IUFD (P-value = .0001). Shorter placental cord insertion distances led to more episodes of preterm labor (P-value = .057). Eccentric-type placental cord insertion was significantly associated with the development of preeclampsia (P-value = .006). DISCUSSION: Abnormalities in placental diameter and cord insertion can lead to significant maternal-fetal complications including preterm labor, IUFD, and preeclampsia.


Subject(s)
Obstetric Labor, Premature , Pre-Eclampsia , Female , Humans , Infant, Newborn , Pregnancy , Fetal Death , Obstetric Labor, Premature/pathology , Placenta/pathology , Pre-Eclampsia/pathology , Pregnancy Outcome , Stillbirth , Prospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL