Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 25
Filter
1.
Clin Cardiol ; 47(8): e24324, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39054901

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has been increasingly used in patients with severe aortic stenosis (AS). Since coronary artery disease (CAD) is common among these patients, it is crucial to choose the best method and timing of revascularization. This study aims to compare different timing strategies of percutaneous coronary intervention (PCI) in patients with severe AS undergoing TAVI to clarify whether PCI timing affects the patients' outcomes or not. METHODS: A frequentist network meta-analysis was conducted comparing three different revascularization strategies in patients with CAD undergoing TAVI. The 30-day all-cause mortality, in-hospital mortality, all-cause mortality at 1 year, 30-day rates of myocardial infarction (MI), stroke, and major bleeding, and the need for pacemaker implantation at 6 months were analyzed in this study. RESULTS: Our meta-analysis revealed that PCI during TAVI had higher 30-day mortality (RR = 2.46, 95% CI = 1.40-4.32) and in-hospital mortality (RR = 1.70, 95% CI = [1.08-2.69]) compared to no PCI. Post-TAVI PCI was associated with higher 1-year mortality compared to other strategies. While no significant differences in major bleeding or stroke were observed, PCI during TAVI versus no PCI (RR = 3.63, 95% CI = 1.27-10.43) showed a higher rate of 30-day MI. CONCLUSION: Our findings suggest that among patients with severe AS and CAD undergoing TAVI, PCI concomitantly with TAVI seems to be associated with worse 30-day outcomes compared with no PCI. PCI after TAVI demonstrated an increased risk of 1-year mortality compared to alternative strategies. Choosing a timing strategy should be individualized based on patient characteristics and procedural considerations.


Subject(s)
Aortic Valve Stenosis , Network Meta-Analysis , Percutaneous Coronary Intervention , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Percutaneous Coronary Intervention/methods , Percutaneous Coronary Intervention/adverse effects , Risk Factors , Hospital Mortality , Treatment Outcome , Time Factors , Coronary Artery Disease/mortality , Coronary Artery Disease/therapy , Coronary Artery Disease/complications , Coronary Artery Disease/surgery , Risk Assessment/methods , Severity of Illness Index
2.
PLoS One ; 19(7): e0307120, 2024.
Article in English | MEDLINE | ID: mdl-39008468

ABSTRACT

AIM: Sleep duration has been suggested to be associated with hypertension (HTN). However, evidence of the nature of the relationship and its direction has been inconsistent. Therefore, we performed a meta-analysis to assess the relationship between sleep duration and risk of HTN incidence, and to distinguish more susceptible populations. METHODS: PubMed, Embase, Scopus, Web of Science, and ProQuest were searched from January 2000 to May 2023 for cohort studies comparing short and long sleep durations with 7-8 hours of sleep for the risk of HTN incidence. Random-effect model (the DerSimonian-Laird method) was applied to pool risk ratios (RR) and 95% confidence interval (CI). RESULTS: We included sixteen studies ranging from 2.4 to 18 years of follow-up duration evaluating HTN incidence in 1,044,035 people. Short sleep duration was significantly associated with a higher risk of developing HTN (HR: 1.07, 95% CI: 1.06-1.09). The association was stronger when the sleep duration was less than 5 hours (HR: 1.11, 95% CI: 1.08-1.14). In contrast to males, females (HR: 1.07, 95% CI: 1.04-1.09) were more vulnerable to developing HTN due to short sleep duration. No significant difference between different follow-up durations and age subgroups was observed. Long sleep duration was not associated with an increased incidence of HTN. CONCLUSION: Short sleep duration was associated with higher risk of HTN incidence, however, there was no association between long sleep duration and incidence of HTN. These findings highlight the importance of implementing target-specific preventive and interventional strategies for vulnerable populations with short sleep duration to reduce the risk of HTN.


Subject(s)
Hypertension , Sleep , Humans , Hypertension/epidemiology , Sleep/physiology , Incidence , Male , Cohort Studies , Female , Risk Factors , Time Factors , Sleep Duration
3.
Eur J Med Res ; 29(1): 388, 2024 Jul 27.
Article in English | MEDLINE | ID: mdl-39068447

ABSTRACT

BACKGROUND: Newer generation ultrathin strut stents are associated with less incidence of target lesion failure (TLF) in patients undergoing percutaneous coronary intervention (PCI) in the short term. However, its long-term effect on different cardiovascular outcomes remains unknown. OBJECTIVES: We aim to identify the effects of newer-generation ultrathin-strut stents vs. standard thickness second-generation drug-eluting stents (DES) on long-term outcomes of revascularization in coronary artery disease. METHODS: We searched PubMed, Web of Science, Cochrane Library databases, and Scopus for randomized controlled trials (RCTs) and registries that compare newer-generation ultrathin-strut (< 70 mm) with thicker strut (> 70 mm) DES to evaluate cardioprotective effects over a period of up to 5 years. Primary outcome was TLF, a composite of cardiac death, target vessel myocardial infarction (TVMI) or target lesion revascularization (TLR). Secondary outcomes included the components of TLF, stent thrombosis (ST), and all-cause death were pooled as the standardized mean difference between the two groups from baseline to endpoint. RESULTS: We included 19 RCTs and two prospective registries (103,101 patients) in this analysis. The overall effect on the primary outcome was in favor of second-generation ultrathin struts stents in terms of TLF at ≥ 1 year, ≥ 2 years, and ≥ 3 years (P value = 0.01, 95% CI [0.75, 0.96]), P value = 0.003, 95% CI [0.77, 0.95]), P value = 0.007, 95% CI [0.76, 0.96]), respectively. However, there was no reported benefit in terms of TLF when we compared the two groups at ≥ 5 years (P value = 0.21), 95% CI [0.85, 1.04]). Some of the reported components of the primary and secondary outcomes, such as TLR, target vessel revascularization (TVR), and TVMI, showed the same pattern as the TLF outcome. CONCLUSION: Ultrathin-strut DES showed a beneficial effect over thicker strut stents for up to 3 years. However, at the 5-year follow-up, the ultrathin strut did not differ in terms of TLF, TLR, TVR, and TVMI compared with standard-thickness DES, with similar risks of patient-oriented composite endpoint (POCE), MI, ST, cardiac death, and all-cause mortality.


Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Percutaneous Coronary Intervention , Humans , Percutaneous Coronary Intervention/methods , Coronary Artery Disease/surgery , Coronary Artery Disease/therapy , Follow-Up Studies , Treatment Outcome , Randomized Controlled Trials as Topic
4.
Atherosclerosis ; 390: 117449, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38262275

ABSTRACT

BACKGROUND AND AIMS: Anatomical imaging alone of coronary atherosclerotic plaques is insufficient to identify risk of future adverse events and guide management of non-culprit lesions. Low endothelial shear stress (ESS) and high plaque structural stress (PSS) are associated with events, but individually their predictive value is insufficient for risk prediction. We determined whether combining multiple complementary, biomechanical and anatomical plaque characteristics improves outcome prediction sufficiently to inform clinical decision-making. METHODS: We examined baseline ESS, ESS gradient (ESSG), PSS, and PSS heterogeneity index (HI), and plaque burden in 22 lesions that developed subsequent events and 64 control lesions that remained quiescent from the PROSPECT study. RESULTS: 86 fibroatheromas were analysed from 67 patients. Lesions with events showed higher PSS HI (0.32 vs. 0.24, p<0.001), lower local ESS (0.56Pa vs. 0.91Pa, p = 0.007), and higher ESSG (3.82 Pa/mm vs. 1.96 Pa/mm, p = 0.007), while high PSS HI (hazard ratio [HR] 3.9, p = 0.006), high ESSG (HR 3.4, p = 0.007) and plaque burden>70 % (HR 2.6, p = 0.02) were independent outcome predictors in multivariate analysis. Combining low ESS, high ESSG, and high PSS HI gave both high positive predictive value (80 %), which increased further combined with plaque burden>70 %, and negative predictive value (81.6 %). Low ESS, high ESSG, and high PSS HI co-localised spatially within 1 mm in lesions with events, and importantly, this cluster was distant from the minimum lumen area site. CONCLUSIONS: Combining complementary biomechanical and anatomical metrics significantly improves risk-stratification of individual coronary lesions. If confirmed from larger prospective studies, our results may inform targeted revascularisation vs. conservative management strategies.


Subject(s)
Coronary Artery Disease , Plaque, Atherosclerotic , Humans , Plaque, Atherosclerotic/complications , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Coronary Artery Disease/complications , Prospective Studies , Risk Factors , Coronary Vessels/diagnostic imaging , Ultrasonography, Interventional/methods , Clinical Decision-Making , Predictive Value of Tests , Coronary Angiography/methods
5.
Medicine (Baltimore) ; 102(46): e35770, 2023 Nov 17.
Article in English | MEDLINE | ID: mdl-37986405

ABSTRACT

BACKGROUND: There have been controversial findings from recent studies regarding anthracyclines use and the subsequent risk of arrhythmias. This study aimed to evaluate the existing evidence of the risk of arrhythmias in patients treated with anthracyclines. METHODS: PubMed, Scopus, and Web of Science databases were searched up to April 2022 using keywords such as "anthracycline" and "arrhythmia." Dichotomous data were presented as relative risk (RR) and confidence interval (CI), while continuous data were presented as mean difference (MD) and CI. Revman software version 5.4 was used for the analysis. RESULTS: Thirteen studies were included with a total of 26891 subjects. Pooled analysis showed that anthracyclines therapy was significantly associated with a higher risk of arrhythmia (RR: 1.58; 95% CI: 1.41-1.76; P < .00001), ST segment and T wave abnormalities (RR: 1.73, 95% CI: 1.18-2.55, P = .005), conduction abnormalities and AV block (RR = 1.86, 95% CI = 1.06-3.25, P = .03), and tachycardia (RR: 1.736, 95% CI: 1.11-2.69, P = .02). Further analyses of the associations between anthracyclines and atrial flutter (RR = 1.30, 95% CI = 0.29-5.89, P = .74), atrial ectopic beats (RR: 1.27, 95% CI: 0.78-2.05, P = .34), and ventricular ectopic beats (RR: 0.93, 95% CI: 0.53-1.65, P = .81) showed no statistically significant results. Higher doses of anthracycline were associated with a higher risk of arrhythmias (RR: 1.49; 95% CI: 1.08-2.05; P = .02) compared to the lower doses (RR: 1.36; 95% CI: 1.00-1.85; P = .05). Newer generations of Anthracycline maintained the arrhythmogenic properties of previous generations, such as Doxorubicin. CONCLUSION: Anthracyclines therapy was significantly associated with an increased risk of arrhythmias. Accordingly, Patients treated with anthracyclines should be screened for ECG abnormalities and these drugs should be avoided in patients susceptible to arrhythmia. The potential benefit of the administration of prophylactic anti-fibrotic and anti-arrhythmic drugs should also be explored.


Subject(s)
Anthracyclines , Leukemia, Myeloid, Acute , Humans , Anthracyclines/adverse effects , Arrhythmias, Cardiac/chemically induced , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/drug therapy , Antibiotics, Antineoplastic/adverse effects , Doxorubicin , Tachycardia/chemically induced , Leukemia, Myeloid, Acute/drug therapy
6.
Curr Opin Cardiol ; 38(6): 496-503, 2023 11 01.
Article in English | MEDLINE | ID: mdl-37767898

ABSTRACT

PURPOSE OF REVIEW: Major adverse cardiac events (MACE) typically arise from nonflow-limiting coronary artery disease and not from flow-limiting obstructions that cause ischemia. This review elaborates the current understanding of the mechanism(s) for plaque development, progression, and destabilization and how identification of these high-risk features can optimally inform clinical management. RECENT FINDINGS: Advanced invasive and noninvasive coronary imaging and computational postprocessing enhance an understanding of pathobiologic/pathophysiologic features of coronary artery plaques prone to destabilization and MACE. Early investigations of high-risk plaques focused on anatomic and biochemical characteristics (large plaque burden, severe luminal obstruction, thin cap fibroatheroma morphology, and large lipid pool), but more recent studies underscore that additional factors, particularly biomechanical factors [low endothelial shear stress (ESS), high ESS gradient, plaque structural stress, and axial plaque stress], provide the critical incremental stimulus acting on the anatomic substrate to provoke plaque destabilization. These destabilizing features are often located in areas distant from the flow-limiting obstruction or may exist in plaques without any flow limitation. Identification of these high-risk, synergistic plaque features enable identification of plaques prone to destabilize regardless of the presence or absence of a severe obstruction (Plaque Hypothesis). SUMMARY: Local plaque topography, hemodynamic patterns, and internal plaque constituents constitute high-risk features that may be located along the entire course of the coronary plaque, including both flow-limiting and nonflow-limiting regions. For coronary interventions to have optimal clinical impact, it will be critical to direct their application to the plaque area(s) at highest risk.


Subject(s)
Coronary Artery Disease , Plaque, Atherosclerotic , Humans , Risk Factors , Coronary Vessels/diagnostic imaging , Hemodynamics
7.
Atherosclerosis ; 376: 11-18, 2023 07.
Article in English | MEDLINE | ID: mdl-37257352

ABSTRACT

BACKGROUND AND AIMS: Plaque erosion is a common underlying cause of acute coronary syndromes. The role of endothelial shear stress (ESS) and endothelial shear stress gradient (ESSG) in plaque erosion remains unknown. We aimed to determine the role of ESS metrics and maximum plaque slope steepness in plaques with erosion versus stable plaques. METHODS: This analysis included 46 patients/plaques from TOTAL and COMPLETE trials and Brigham and Women's Hospital's database who underwent angiography and OCT. Plaques were divided into those with erosion (n = 24) and matched stable coronary plaques (n = 22). Angiographic views were used to generate a 3-D arterial reconstruction, with centerlines merged from angiography and OCT pullback. Local ESS metrics were assessed by computational fluid dynamics. Among plaque erosions, the up- and down-slope (Δ lumen area/frame) was calculated for each culprit plaque. RESULTS: Compared with stable plaque controls, plaques with an erosion were associated with higher max ESS (8.3 ± 4.8 vs. 5.0 ± 1.9 Pa, p = 0.02) and max ESSG any direction (9.2 ± 7.5 vs. 4.3 ± 3.11 Pa/mm, p = 0.005). Proximal erosion was associated with a steeper plaque upslope while distal erosion with a steeper plaque downslope. Max ESS and Max ESSG any direction were independent factors in the development of plaque erosion (OR 1.32, 95%CI 1.06-1.65, p = 0.014; OR 1.22, 95% CI 1.03-1.45, p = 0.009, respectively). CONCLUSIONS: In plaques with similar luminal stenosis, plaque erosion was strongly associated with higher ESS, ESS gradients, and plaque slope as compared with stable plaques. These data support that ESS and slope metrics play a key role in the development of plaque erosion and may help prognosticate individual plaques at risk for future erosion.


Subject(s)
Coronary Artery Disease , Plaque, Atherosclerotic , Humans , Female , Coronary Artery Disease/diagnostic imaging , Endothelium, Vascular , Coronary Angiography , Heart , Coronary Vessels/diagnostic imaging
8.
J Cardiovasc Comput Tomogr ; 17(3): 201-210, 2023.
Article in English | MEDLINE | ID: mdl-37076326

ABSTRACT

INTRODUCTION: Intravascular ultrasound (IVUS) studies have shown that biomechanical variables, particularly endothelial shear stress (ESS), add synergistic prognostic insight when combined with anatomic high-risk plaque features. Non-invasive risk assessment of coronary plaques with coronary computed tomography angiography (CCTA) would be helpful to enable broad population risk-screening. AIM: To compare the accuracy of ESS computation of local ESS metrics by CCTA vs IVUS imaging. METHODS: We analyzed 59 patients from a registry of patients who underwent both IVUS and CCTA for suspected CAD. CCTA images were acquired using either a 64- or 256-slice scanner. Lumen, vessel, and plaque areas were segmented from both IVUS and CCTA (59 arteries, 686 3-mm segments). Images were co-registered and used to generate a 3-D arterial reconstruction, and local ESS distribution was assessed by computational fluid dynamics (CFD) and reported in consecutive 3-mm segments. RESULTS: Anatomical plaque characteristics (vessel, lumen, plaque area and minimal luminal area [MLA] per artery) were correlated when measured with IVUS and CCTA: 12.7 â€‹± â€‹4.3 vs 10.7 â€‹± â€‹4.5 â€‹mm2, r â€‹= â€‹0.63; 6.8 â€‹± â€‹2.7 vs 5.6 â€‹± â€‹2.7 â€‹mm2, r â€‹= â€‹0.43; 5.9 â€‹± â€‹2.9 vs 5.1 â€‹± â€‹3.2 â€‹mm2, r â€‹= â€‹0.52; 4.5 â€‹± â€‹1.3 vs 4.1 â€‹± â€‹1.5 â€‹mm2, r â€‹= â€‹0.67 respectively. ESS metrics of local minimal, maximal, and average ESS were also moderately correlated when measured with IVUS and CCTA (2.0 â€‹± â€‹1.4 vs 2.5 â€‹± â€‹2.6 â€‹Pa, r â€‹= â€‹0.28; 3.3 â€‹± â€‹1.6 vs 4.2 â€‹± â€‹3.6 â€‹Pa, r â€‹= â€‹0.42; 2.6 â€‹± â€‹1.5 vs 3.3 â€‹± â€‹3.0 â€‹Pa, r â€‹= â€‹0.35, respectively). CCTA-based computation accurately identified the spatial localization of local ESS heterogeneity compared to IVUS, with Bland-Altman analyses indicating that the absolute ESS differences between the two CCTA methods were pathobiologically minor. CONCLUSION: Local ESS evaluation by CCTA is possible and similar to IVUS; and is useful for identifying local flow patterns that are relevant to plaque development, progression, and destabilization.


Subject(s)
Coronary Artery Disease , Plaque, Atherosclerotic , Humans , Computed Tomography Angiography , Coronary Angiography/methods , Predictive Value of Tests , Tomography, X-Ray Computed/methods , Ultrasonography, Interventional/methods , Coronary Artery Disease/diagnostic imaging , Coronary Vessels/diagnostic imaging
9.
Clin Cardiol ; 46(4): 376-385, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36841256

ABSTRACT

BACKGROUND: Insomnia has been closely associated with cardiovascular disease (CVD) including myocardial infarction (MI). Our study aims to assess the eligibility of insomnia as a potential risk factor for MI. METHODS: PubMed, Scopus, and Web of Science were searched using terms; such as "Insomnia" and "MI." Only observational controlled studies with data on the incidence of MI among insomniacs were included. Revman software version 5.4 was used for the analysis. RESULTS: Our pooled analysis showed a significant association between insomnia and the incidence of MI compared with noninsomniacs (relative risk [RR] = 1.69, 95% confidence interval [CI] = 1.41-2.02, p < .00001). Per sleep duration, we detected the highest association between ≤5 h of sleep, and MI incidence compared to 7-8 h of sleep (RR = 1.56, 95% CI = 1.41-1.73). Disorders of initiating and maintaining sleep were associated with increased MI incidence (RR = 1.13, 95% CI = 1.04-1.23, p = .003). However, subgroup analysis of nonrestorative sleep and daytime dysfunction showed an insignificant association with MI among both groups (RR = 1.06, 95% CI = 0.91-1.23, p = .46). Analysis of age, follow-up duration, sex, and comorbidities showed a significant association in insomniacs. CONCLUSION: Insomnia and ≤5 h of sleep are highly associated with increased incidence of MI; an association comparable to that of other MI risk factors and as such, it should be considered as a risk factor for MI and to be incorporated into MI prevention guidelines.


Subject(s)
Myocardial Infarction , Sleep Initiation and Maintenance Disorders , Humans , Incidence , Sleep Initiation and Maintenance Disorders/epidemiology , Myocardial Infarction/epidemiology , Risk Factors , Sleep
10.
Catheter Cardiovasc Interv ; 101(1): 44-57, 2023 01.
Article in English | MEDLINE | ID: mdl-36403271

ABSTRACT

OBJECTIVES: We investigated the results of T and small protrusion (TAP) versus a novel modification of TAP (mTAP) stenting by multimodality imaging in bench testing and in patients with coronary bifurcation lesions (CBL). BACKGROUND: TAP stenting is a suboptimal technique for bailout side branch (SB) stenting. METHODS: In a bench model, optical coherence tomography (OCT), microscopic examinations (ME), and computational fluid dynamics (CFD) were performed after TAP and mTAP stenting. In 20 patients with CBL, 80 intravascular ultrasound (IVUS) examinations were performed during mTAP stenting in which the SB stent was pulled-back to indent the inflated main vessel (MV) balloon and deployed while deflating it. For TAP stenting, the tip of the SB stent was positioned in the MV and deployed. RESULTS: In bench testing, OCT showed neocarina length (NL) was shorter and minimum stent area (MSA) was larger after mTAP versus TAP stenting (2.84 ± 0.70 vs. 4.80 ± 020 mm; 6.75 ± 1.50 vs. 4.5 ± 2.2 mm2 ; respectively; p < 0.05). By ME, NL was shorter and shear rate trended lower after mTAP versus TAP stenting. In patients, IVUS showed MSA was larger after versus before mTAP stenting (6.32 ± 0.58 vs. 5.21 ± 0.56 mm2 ; p < 0.01); NL was 1.43 ± 0.22 mm with SB ostium coverage. The Seattle Angina questionnaire (SAQ) score was higher at 6 months versus baseline (85 ± 4.0 vs. 48 ± 6.0, respectively; p < 0.001). CONCLUSIONS: This multimodality imaging study showed, for the first time, mTAP stenting resulted in larger stent area and shorter neocarina than TAP stenting in bench testing. In patients with CBL, mTAP stenting led to larger stent area, short neocarina with complete SB ostium coverage, and improved the SAQ score at follow-up.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Artery Disease , Humans , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Angioplasty, Balloon, Coronary/methods , Coronary Angiography , Treatment Outcome , Stents , Coronary Vessels/diagnostic imaging
11.
Egypt Heart J ; 73(1): 102, 2021 Nov 16.
Article in English | MEDLINE | ID: mdl-34783920

ABSTRACT

Precise and accurate characterization of the aortic valve complex is a vital step in the procedure planning for transcatheter aortic valve replacement (TAVR). Far-field intravascular ultrasound (IVUS) is a novel technology that can be utilized to assess aortic valve annulus and predict paravalvular leak, with comparable results to multi-detector computed tomography-the current gold standard in the preprocedural planning in TAVR. Far-field IVUS carries the advantage of minimal contrast use and lower radiation exposure. In this commentary, we describe two cases of far-field IVUS use during TAVR procedures and review its role as a complementary tool to current the imaging modalities used in TAVR.

12.
Catheter Cardiovasc Interv ; 97(2): 237-244, 2021 02 01.
Article in English | MEDLINE | ID: mdl-31971338

ABSTRACT

OBJECTIVES: We investigated the role of a new intravascular ultrasound (IVUS)-guided stenting strategy versus angiography on optimal stent expansion (OSE) and procedural outcomes in patients with positive lesion remodeling. BACKGROUND: There are no IVUS criteria on how to achieve OSE. METHODS: A total of 100 patients were assigned to a new IVUS-guided stenting strategy (IVUS group) versus angiography-guided stenting (Angio group). In the IVUS group, among patients with positive lesion remodeling, defined as a remodeling ratio (RR; lesion external elastic membrane (EEM) area/distal reference EEM area) >1.05, the stent was expanded with a balloon sized to the distal reference EEM diameter. In the Angio group, the stent was expanded by visual estimation. In both groups, IVUS was performed after postdilation. RESULTS: Minimum stent area (MSA) and stent volume index were significantly larger in the IVUS versus Angio group (7.1 ± 1.9 vs. 5.9 ± 1.5 mm2 , and 8.7 ± 2.1 vs. 7.5 ± 1.8 mm3 /mm, respectively; p < .01). The percentages of OSE, defined as an MSA ≥5.4 mm2 , MSA ≥90% of distal reference lumen area (DRLA), or MSA > DRLA, were significantly higher in the IVUS versus Angio group (80 vs. 56%, 78 vs. 54%, and 71 vs. 38%, respectively; p < .01). Stent underexpansion, malapposition, and residual reference segment stenosis were significantly higher in the Angio versus IVUS group (44 vs. 12%, 16 vs. 4%, and 12 vs. 0%, respectively; p < .05). In the IVUS group, owing to positive remodeling, there was no incidence of dissection or perforation. CONCLUSIONS: This new strategy of IVUS-guided stenting in patients with positive lesion remodeling, compared with angiography, significantly increased stent expansion and decreased stent underexpansion, malapposition, and residual reference segment stenosis with no complications.


Subject(s)
Stents , Ultrasonography, Interventional , Coronary Angiography , Humans , Treatment Outcome , Ultrasonography
13.
Atherosclerosis ; 318: 52-59, 2021 02.
Article in English | MEDLINE | ID: mdl-33129585

ABSTRACT

Plaque rupture followed by intracoronary thrombus formation is recognized as the most common pathophysiological mechanism in acute coronary syndromes (ACS). The second most common underlying substrate for ACS is plaque erosion whose hallmark is thrombus formation without cap disruption. Invasive and non-invasive methods have emerged as a promising tool for evaluation of plaque features that either predict or detect plaque erosion. Optical coherence tomography (OCT), high-definition intravascular ultrasound (IVUS), near-infrared spectroscopy (NIRS), and near-infrared autofluorescence (NIRF) have been used to study plaque erosion. The detection of plaque erosion in the clinical setting, mainly facilitated by OCT, has shed light upon the complex pathophysiology underlying ACS not related to plaque rupture. Coronary computed tomography angiography (CCTA), which is to date the most commonly used non-invasive technique for coronary plaque evaluation, may also have a role in the evaluation of patients predisposed to erosion. Also, computational models enabling quantification of endothelial shear stress may pave the way to new research in coronary plaque pathophysiology. This review focuses on the recent imaging techniques for the evaluation of plaque erosion including invasive and non-invasive assessment.


Subject(s)
Acute Coronary Syndrome , Coronary Artery Disease , Plaque, Atherosclerotic , Acute Coronary Syndrome/diagnostic imaging , Computed Tomography Angiography , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Vessels/diagnostic imaging , Humans , Plaque, Atherosclerotic/diagnostic imaging , Spectroscopy, Near-Infrared , Tomography, Optical Coherence , Ultrasonography, Interventional
14.
Curr Opin Cardiol ; 35(6): 712-719, 2020 11.
Article in English | MEDLINE | ID: mdl-32852346

ABSTRACT

PURPOSE OF REVIEW: Management of patients with coronary artery disease (CAD) has been based on identification of a coronary obstruction causing ischemia and performing a revascularization procedure to reduce that ischemia, with the goal of thereby preventing subsequent major adverse cardiac events (MACEs) in that vascular territory. Recent investigations demonstrate that preemptive percutaneous coronary intervention (PCI) of nonculprit coronary lesions (NCLs) that may not cause ischemia in patients with ST-segment elevation myocardial infarction (STEMI) reduces MACE. In this review, we focus on preemptive PCI, discuss its mechanistic benefits and speculate on its potential value for other coronary syndromes. RECENT FINDINGS: The COMPLETE trial in STEMI patients treated with primary PCI demonstrated that preemptive PCI of NCL obstructions, which may not cause ischemia, but often exhibit high-risk OCT plaque characteristics, reduced cardiovascular death or nonfatal myocardial infarction. Reduction in MACE from preemptive PCI of NCL was similar for lesions confirmed to cause ischemia (fractional flow reserve <0.80) and for lesions that were only visually assessed to have luminal obstruction at least 70%.The ISCHEMIA trial in patients with stable CAD and moderate/severe ischemia demonstrated that MACE risk increased progressively with more extensive atherosclerosis, but that performing PCI of ischemia-producing lesions did not reduce MACE. Adverse cardiac events likely originated in high-risk plaque areas not treated with PCI. SUMMARY: In STEMI patients, preemptive PCI of high-risk NCL that may not cause ischemia improves long-term MACE. In stable CAD patients, MACE increases as the atherosclerotic burden increases, but PCI of the ischemia-producing lesion itself does not improve outcomes compared with optimal medical therapy. Adverse events likely originate in high-risk plaque areas that are distinct from ischemia-producing obstructions. Identification of highest-risk atherosclerotic lesions responsible for future MACE may provide an opportunity for preemptive PCI in patients with a variety of coronary syndromes.


Subject(s)
Coronary Artery Disease , Fractional Flow Reserve, Myocardial , Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction , Coronary Artery Disease/surgery , Humans , Treatment Outcome
15.
Circ Cardiovasc Interv ; 10(10)2017 Oct.
Article in English | MEDLINE | ID: mdl-29038225

ABSTRACT

BACKGROUND: Bench models of coronary bifurcation lesions demonstrated that the proximal optimization technique (POT) expanded the stent and opened the side branch (SB). We investigated the role of POT guided by intravascular ultrasound on the main vessel (MV) stent expansion and SB fractional flow reserve (FFR) in patients with coronary bifurcation lesion. METHODS AND RESULTS: In 40 patients with coronary bifurcation lesion, 120 intravascular ultrasound examinations of the MV were performed at baseline, after MV stenting, and POT followed by 95 FFR measurements of the SB. In the proximal stent segment, stent volume index and minimum stent area were larger after POT versus MV stenting (9.2±3.4 versus 7.40±2.0 mm3/mm and 7.65±1.8 versus 6.38±1.7 mm2, respectively; P<0.01). In the bifurcation segment, minimum stent area was larger after POT versus MV stenting (6.45±2.1 versus 5.9±2.0 mm2, respectively; P<0.05). POT expanded the stent symmetrically. After POT, SB FFR was <0.75 in 12 patients (30%), which improved to >0.75 after SB dilation or SB stenting+final POT. SB FFR was significantly higher after POT+SB dilation or SB stenting+final POT versus after MV stenting and POT. CONCLUSIONS: This is the first study of POT guided by intravascular ultrasound in patients with coronary bifurcation lesion, demonstrating that POT symmetrically expanded the proximal and bifurcation segments of the stent. After POT, SB FFR was <0.75 in a third of patients, which improved to >0.75 after SB dilation or SB stenting+final POT.


Subject(s)
Coronary Artery Disease/surgery , Drug-Eluting Stents , Percutaneous Coronary Intervention/methods , Ultrasonography, Interventional , Aged , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Female , Fractional Flow Reserve, Myocardial , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/instrumentation , Percutaneous Coronary Intervention/statistics & numerical data , Prospective Studies
16.
Eur Heart J Cardiovasc Imaging ; 18(12): 1404-1413, 2017 Dec 01.
Article in English | MEDLINE | ID: mdl-28165129

ABSTRACT

AIMS: The use of contrast media with multidetector computed tomography (MDCT) may induce acute kidney injury in patients with renal failure undergoing transcatheter aortic valve replacement (TAVR). We investigated the role of large-field intravascular ultrasound (IVUS) vs. MDCT and two-dimensional transoesophageal echocardiography (2D-TEE) for annular sizing and predicting paravalvular regurgitation (PVR) during TAVR. METHODS AND RESULTS: The aortic annulus was measured by large-field IVUS and 2D-TEE, and compared with MDCT in 50 patients undergoing TAVR. The IVUS and MDCT annular areas and diameters were not significantly different (446 ± 87 mm2 and 23.8 ± 84 mm vs. 466 ± 84 mm2 and 24 ± 2.1 mm, respectively; P > 0.05). IVUS and MDCT mean annular diameters were significantly greater than TEE diameter (23.8 ± 2.4 and 24 ± 2.1 vs. 22 ± 0.65 mm, respectively; P < 0.01). PVR ≥ Mild occurred in 13 patients (26%); 5 patients required post-dilation and 2 patients a second valve. Receiver operating characteristic analyses showed that transcatheter heart valve (THV) area - IVUS or MDCT areas equally predicted of ≥ mild PVR (areas under the curve [AUC] 0.79 and 0.81, respectively; P < 0.001), and were greater than THV diameter-TEE diameter (AUC 0.79 and 0.81 vs. 0.56, respectively; P < 0.05). CONCLUSIONS: The aortic annular measurements and predicting PVR by large field IVUS were not significantly different from those of MDCT, but were greater than those of TEE. Large filed IVUS can be reliably used in lieu of MDCT for annular sizing in patients with aortic stenosis and renal failure or suboptimal MDCT images.


Subject(s)
Aortic Valve Stenosis/diagnostic imaging , Echocardiography, Transesophageal/methods , Intraoperative Complications/diagnostic imaging , Multidetector Computed Tomography/methods , Transcatheter Aortic Valve Replacement/methods , Ultrasonography, Interventional/methods , Analysis of Variance , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Stenosis/surgery , Area Under Curve , Chi-Square Distribution , Cohort Studies , Female , Humans , Male , Predictive Value of Tests , Prognosis , Prospective Studies , ROC Curve , Risk Assessment , Severity of Illness Index , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
18.
Am J Cardiol ; 111(7): 979-84, 2013 Apr 01.
Article in English | MEDLINE | ID: mdl-23340034

ABSTRACT

We assessed the ethnic differences in coronary atherosclerosis lesion morphology between white and Asian patients. Our hypothesis was that left main coronary artery (LMCA) disease was more focal and less complex in Asian than in Western white patients. We studied 99 Asian patients (Japan and South Korea) and 99 matched control United States white patients with a stable clinical presentation and >30% LMCA angiographic diameter stenosis by visual estimation. The matching parameters included age, gender, and diabetes mellitus. The vessel and lumen areas and calcium arc were analyzed every 0.5 mm and normalized for analysis length. Overall, 75.1% of the patients were men and 34.1% had diabetes. The patient age was 68.0 ± 10 years, with no differences between the Asian and white patients. The Asian patients had a lower prevalence of hyperlipidemia than the white patients (41.4% vs 81.8%; p <0.0001) and were smaller in size, and the white patients were more obese (body mass index 23.7 ± 2.6 vs 27.6 ± 4.1 kg/m(2), p <0.0001). The Asian patients had a smaller lumen area (5.2 ± 1.8 vs 6.2 ± 14 mm(2); p <0.0001), larger vessel area (20.0 ± 4.9 vs 18.4 ± 4.4 mm(2); p <0.0001), and larger plaque burden (72 ± 10 vs 64 ± 12%: p <0.0001) at the minimum lumen site and over the entire LMCA length. The white patients had more calcification, whether assessed by the maximum arc (82° ± 74° vs 49° ± 45°; p <0.0001) or total length (3.6 ± 3.2 vs 2.1 ± 2.1 mm; p <0.0001). In conclusion, after matching well-known risk factors, there appeared to be ethnic differences in coronary atherosclerosis morphology between Asian and white patients, at least as it affected LMCA morphology.


Subject(s)
Asian People , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/ethnology , Ultrasonography, Interventional , White People , Aged , Chi-Square Distribution , Diabetes Mellitus, Type 2/complications , Diabetes Mellitus, Type 2/epidemiology , Female , Humans , Hyperlipidemias/complications , Hyperlipidemias/epidemiology , Japan , Linear Models , Lipids/blood , Male , Republic of Korea , Risk Factors , United States
19.
Am J Cardiol ; 111(5): 695-9, 2013 Mar 01.
Article in English | MEDLINE | ID: mdl-23273714

ABSTRACT

The primary aim of the present study was to assess the gray scale intravascular ultrasound (IVUS) findings that might be associated with late drug-eluting stent restenosis. The study included 47 patients (54 lesions) who had undergone either baseline IVUS-guided stent implantation or IVUS-guided repeat stenting to treat in-stent restenosis and then had IVUS follow-up data for ≥1.5 years afterward without any intervening procedures. The left anterior descending artery was the culprit in 59% of cases, and 50% of the lesions were at bifurcation sites. Quantitative and qualitative IVUS analyses showed a decreased minimum lumen area at follow-up from 6.0 ± 1.8 to 3.8 ± 1.4 mm(2) (p <0.0001) that was mainly due to neointimal hyperplasia with chronic stent recoil (defined as a >15% decrease in minimum stent area) in only 2 lesions and stent fracture in only 5 lesions. Calcified neointima appeared in 12 lesions, mostly in the form of macrocalcification, and was associated with increased calcium both behind the stent and in the reference segment. In conclusion, late drug-eluting stent restenosis showed neointimal calcification in 20% of cases, and chronic stent recoil was rare.


Subject(s)
Coronary Restenosis/diagnostic imaging , Coronary Vessels/diagnostic imaging , Drug-Eluting Stents , Ultrasonography, Interventional/methods , Aged , Coronary Restenosis/etiology , Coronary Vessels/pathology , Electrocardiography , Female , Follow-Up Studies , Humans , Hyperplasia , Male , Prosthesis Failure , Retrospective Studies
20.
Catheter Cardiovasc Interv ; 81(3): 438-45, 2013 Feb.
Article in English | MEDLINE | ID: mdl-22431198

ABSTRACT

OBJECTIVES: To investigate the clinical value and diagnostic accuracy of enhanced stent imaging (ESI) as compared with quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS). BACKGROUND: ESI is an image acquisition and processing angiography-based software that improves visualization and provides measurements of deployed stents. METHODS: A total of 40 consecutive patients (42 stents) were studied. Stent deployment was evaluated sequentially and independently by angiography, ESI, and IVUS. Following each imaging modality, the operator determined the necessity of postdilation unrelated to the other modalities. Stent diameters were measured off-line by QCA, ESI, and IVUS at several sites along the deployed stent and compared. RESULTS: Following stent deployment and based solely on angiography, the operator decided to postdilate seven of the 42 stents (16.7%). This decision was not changed after reviewing the ESI images of these seven stents. Of the 35 stents not requiring postdilation based on angiography alone, ESI influenced the operator to change the decision and postdilate 10 of 35 stents (28.6%). The ESI-based measurements had better correlation with IVUS (r = 0.721, P < 0.0001) than did QCA with IVUS (r = 0.563, P < 0.0001). Bland-Altman analysis showed a trend towards better agreement between ESI and IVUS than between QCA and IVUS (mean differences = 0.038 vs. 0.121; P = 0.19, respectively). CONCLUSIONS: ESI is an easy to use modality that enhances stent visualization, helps in the decision making process whether to postdilate the stent, and provides estimation of stent expansion with better correlations than QCA when compared to IVUS. © 2012 Wiley Periodicals, Inc.


Subject(s)
Coronary Angiography/methods , Coronary Artery Disease/diagnosis , Image Enhancement/methods , Percutaneous Coronary Intervention/methods , Stents , Ultrasonography, Interventional/methods , Coronary Artery Disease/surgery , Diagnosis, Differential , Female , Follow-Up Studies , Humans , Male , Middle Aged , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL