Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
Add more filters










Publication year range
1.
Mol Imaging Biol ; 26(2): 272-283, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38151580

ABSTRACT

PURPOSE: ABY-029, an epidermal growth factor receptor (EGFR)-targeted, synthetic Affibody peptide labeled with a near-infrared fluorophore, is under investigation for fluorescence-guided surgery of sarcomas. To date, studies using ABY-029 have occurred in tumors naïve to chemotherapy (CTx) and radiation therapy (RTx), although these neoadjuvant therapies are frequently used for sarcoma treatment in humans. The goal of this study was to evaluate the impact of CTx and RTx on tumor EGFR expression and ABY-029 fluorescence of human soft-tissue sarcoma xenografts in a murine model. PROCEDURES: Immunodeficient mice (n = 98) were divided into five sarcoma xenograft groups and three treatment groups - CTx only, RTx only, and CTx followed by RTx, plus controls. Four hours post-injection of ABY-029, animals were sacrificed followed by immediate fluorescence imaging of ex vivo adipose, muscle, nerve, and tumor tissues. Histological hematoxylin and eosin staining confirmed tumor type, and immunohistochemistry staining determined EGFR, cluster of differentiation 31 (CD31), and smooth muscle actin (SMA) expression levels. Correlation analysis (Pearson's correlation coefficients, r) and linear regression (unstandardized coefficient estimates, B) were used to determine statistical relationships in molecular expression and tissue fluorescence between xenografts and treatment groups. RESULTS: Neoadjuvant therapies had no broad impact on EGFR expression (|B|≤ 7.0, p ≥ 0.4) or on mean tissue fluorescence (any tissue type, (|B|≤ 2329.0, p ≥ 0.1). Mean tumor fluorescence was significantly related to EGFR expression (r = 0.26, p = 0.01), as expected. CONCLUSION: Results suggest that ABY-029 as an EGFR-targeted, fluorescent probe is not negatively impacted by neoadjuvant soft-tissue sarcoma therapies, although validation in humans is required.


Subject(s)
Neoadjuvant Therapy , Sarcoma , Humans , Mice , Animals , Disease Models, Animal , ErbB Receptors/metabolism , Fluorescent Dyes
2.
Article in English | MEDLINE | ID: mdl-37034555

ABSTRACT

Necrotizing soft-tissue infections (NSTIs) are aggressive and deadly. Immediate surgical debridement is standard-of-care, but patients often present with non-specific symptoms, thereby delaying treatment. Because NSTIs cause microvascular thrombosis, we hypothesized that perfusion imaging using indocyanine green (ICG) would show diminished fluorescence signal in NSTI-affected tissues, particularly compared to non-necrotizing, superficial infections. Through a first-in-kind clinical study, we performed first-pass ICG fluorescence perfusion imaging of patients with suspected NSTIs. Early results support our hypothesis that ICG signal voids occur in NSTI-affected tissues and that dynamic contrast-enhanced fluorescence parameters reveal tissue kinetics that may be related to disease progression and extent.

3.
Article in English | MEDLINE | ID: mdl-37009433

ABSTRACT

We have co-developed a first-in-kind model of fluorophore testing in freshly amputated human limbs. Ex vivo human tissue provides a unique opportunity for the testing of pre-clinical fluorescent agents, collection of imaging data, and histopathologic examination in human tissue prior to performing in vivo experiments. Existing pre-clinical fluorescent agent studies rely primarily on animal models, which do not directly predict fluorophore performance in humans and can result in wasted resources and time if an agent proves ineffective in early human trials. Because fluorophores have no desired therapeutic effect, their clinical utility is based solely on their safety and ability to highlight tissues of interest. Advancing to human trials even via the FDA's phase 0/microdose pathway still requires substantial resources, single-species pharmacokinetic testing, and toxicity testing. In a recently concluded study using amputated human lower limbs, we were able to test successfully a nerve-specific fluorophore in pre-clinical development. This study used systemic administration via vascular cannulization and a cardiac perfusion pump. We envision that this model may assist with early lead agent testing selection for fluorophores with various targets and mechanisms.

4.
Article in English | MEDLINE | ID: mdl-37009434

ABSTRACT

Iatrogenic nerve injury is a common complication across all surgical specialties. Better nerve visualization and identification during surgery will improve outcomes and reduce nerve injuries. The Gibbs Laboratory at Oregon Health and Science University has developed a library of near-infrared, nerve-specific fluorophores to highlight nerves intraoperatively and aid surgeons in nerve identification and visualization; the current lead agent is LGW16-03. Prior to this study, testing of LGW16-03 was restricted to animal models; therefore, it was unknown how LGW16-03 performs in human tissue. To advance LGW16-03 to clinic, we sought to test this current lead agent in ex vivo human tissues from a cohort of patients and determine if the route of administration affects LGW16-03 fluorescence contrast between nerves and adjacent background tissues (muscle and adipose). LGW16-03 was applied to ex vivo human tissue from lower limb amputations via two strategies: (1) systemic administration of the fluorophore using our first-in-kind model for fluorophore testing, and (2) topical application of the fluorophore. Results showed no statistical difference between topical and systemic administration. However, in vivo human validation of these findings is required.

5.
J Biomed Opt ; 28(8): 082802, 2023 08.
Article in English | MEDLINE | ID: mdl-36619496

ABSTRACT

Significance: This first-in-kind, perfused, and amputated human limb model allows for the collection of human data in preclinical selection of lead fluorescent agents. The model facilitates more accurate selection and testing of fluorophores with human-specific physiology, such as differential uptake and signal in fat between animal and human models with zero risk to human patients. Preclinical testing using this approach may also allow for the determination of tissue toxicity, clearance time of fluorophores, and the production of harmful metabolites. Aim: This study was conducted to determine the fluorescence intensity values and tissue specificity of a preclinical, nerve tissue targeted fluorophore, as well as the capacity of this first-in-kind model to be used for lead fluorescent agent selection in the future. Approach: Freshly amputated human limbs were perfused for 30 min prior to in situ and ex vivo imaging of nerves with both open-field and closed-field commercial fluorescence imaging systems. Results: In situ, open-field imaging demonstrated a signal-to-background ratio (SBR) of 4.7 when comparing the nerve with adjacent muscle tissue. Closed-field imaging demonstrated an SBR of 3.8 when the nerve was compared with adipose tissue and 4.8 when the nerve was compared with muscle. Conclusions: This model demonstrates an opportunity for preclinical testing, evaluation, and selection of fluorophores for use in clinical trials as well as an opportunity to study peripheral pathologies in a controlled environment.


Subject(s)
Amputees , Fluorescent Dyes , Animals , Humans , Fluorescent Dyes/metabolism , Muscles , Extremities , Optical Imaging/methods
6.
Mol Imaging Biol ; 25(1): 46-57, 2023 02.
Article in English | MEDLINE | ID: mdl-36447084

ABSTRACT

Fluorescence-guided surgery (FGS) is an evolving field that seeks to identify important anatomic structures or physiologic phenomena with helpful relevance to the execution of surgical procedures. Fluorescence labeling occurs generally via the administration of fluorescent reporters that may be molecularly targeted, enzyme-activated, or untargeted, vascular probes. Fluorescence guidance has substantially changed care strategies in numerous surgical fields; however, investigation and adoption in orthopaedic surgery have lagged. FGS shows the potential for improving patient care in orthopaedics via several applications including disease diagnosis, perfusion-based tissue healing capacity assessment, infection/tumor eradication, and anatomic structure identification. This review highlights current and future applications of fluorescence guidance in orthopaedics and identifies key challenges to translation and potential solutions.


Subject(s)
Neoplasms , Orthopedic Procedures , Orthopedics , Surgery, Computer-Assisted , Humans , Fluorescence , Optical Imaging/methods , Surgery, Computer-Assisted/methods , Fluorescent Dyes
7.
J Surg Oncol ; 127(3): 490-500, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36285723

ABSTRACT

BACKGROUND: Imaging-based navigation technologies require static referencing between the target anatomy and the optical sensors. Imaging-based navigation is therefore well suited to operations involving bony anatomy; however, these technologies have not translated to soft-tissue surgery. We sought to determine if fluorescence imaging complement conventional, radiological imaging-based navigation to guide the dissection of soft-tissue phantom tumors. METHODS: Using a human tissue-simulating model, we created tumor phantoms with physiologically accurate optical density and contrast concentrations. Phantoms were dissected using all possible combinations of computed tomography (CT), magnetic resonance, and fluorescence imaging; controls were included. The data were margin accuracy, margin status, tumor spatial alignment, and dissection duration. RESULTS: Margin accuracy was higher for combined navigation modalities compared to individual navigation modalities, and accuracy was highest with combined CT and fluorescence navigation (p = 0.045). Margin status improved with combined CT and fluorescence imaging. CONCLUSIONS: At present, imaging-based navigation has limited application in guiding soft-tissue tumor operations due to its inability to compensate for positional changes during surgery. This study indicates that fluorescence guidance enhances the accuracy of imaging-based navigation and may be best viewed as a synergistic technology, rather than a competing one.


Subject(s)
Soft Tissue Neoplasms , Surgery, Computer-Assisted , Humans , Fluorescence , Surgery, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Phantoms, Imaging , Soft Tissue Neoplasms/surgery
8.
Magn Reson Med ; 87(3): 1621-1637, 2022 03.
Article in English | MEDLINE | ID: mdl-34719047

ABSTRACT

PURPOSE: Electron paramagnetic resonance oximetry using the OxyChip as an implantable oxygen sensor can directly and repeatedly measure tissue oxygen levels. A phase I, first-in-human clinical study has established the safety and feasibility of using OxyChip for reliable and repeated measurements of oxygen levels in a variety of tumors and treatment regimens. A limitation in these studies is the inability to easily locate and identify the implanted probes in the tissue, particularly in the long term, thus limiting spatial/anatomical registration of the implant for proper interpretation of the oxygen data. In this study, we have developed and evaluated an enhanced oxygen-sensing probe embedded with gold nanoparticles (GNP), called the OxyChip-GNP, to enable visualization of the sensor using routine clinical imaging modalities. METHODS: In vitro characterization, imaging, and histopathology studies were carried out using tissue phantoms, excised tissues, and in vivo animal models (mice and rats). RESULTS: The results demonstrated a substantial enhancement of ultrasound and CT contrast using the OxyChip-GNP without compromising its electron paramagnetic resonance and oxygen-sensing properties or biocompatibility. CONCLUSIONS: The OxyChips embedded with gold nanoparticles (OxyChip-GNP) can be readily identified in soft tissues using standard clinical imaging modalities such as CT, cone beam-CT, or ultrasound imaging while maintaining its capability to make repeated in vivo measurements of tissue oxygen levels over the long term. This unique capability of the OxyChip-GNP facilitates precisely localized in vivo oxygen measurements in the clinical setting.


Subject(s)
Gold , Metal Nanoparticles , Animals , Electron Spin Resonance Spectroscopy , Mice , Oximetry , Oxygen , Rats
9.
Appl Magn Reson ; 52(10): 1321-1342, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34744319

ABSTRACT

OBJECTIVES: (1) Summarize revisions made to the implantable resonator (IR) design and results of testing to characterize biocompatibility;(2) Demonstrate safety of implantation and feasibility of deep tissue oxygenation measurement using electron paramagnetic resonance (EPR) oximetry. STUDY DESIGN: In vitro testing of the revised IR and in vivo implantation in rabbit brain and leg tissues. METHODS: Revised IRs were fabricated with 1-4 OxyChips with a thin wire encapsulated with two biocompatible coatings. Biocompatibility and chemical characterization tests were performed. Rabbits were implanted with either an IR with 2 oxygen sensors or a biocompatible-control sample in both the brain and hind leg. The rabbits were implanted with IRs using a catheter-based, minimally invasive surgical procedure. EPR oximetry was performed for rabbits with IRs. Cohorts of rabbits were euthanized and tissues were obtained at 1 week, 3 months, and 9 months after implantation and examined for tissue reaction. RESULTS: Biocompatibility and toxicity testing of the revised IRs demonstrated no abnormal reactions. EPR oximetry from brain and leg tissues were successfully executed. Blood work and histopathological evaluations showed no significant difference between the IR and control groups. CONCLUSIONS: IRs were functional for up to 9 months after implantation and provided deep tissue oxygen measurements using EPR oximetry. Tissues surrounding the IRs showed no more tissue reaction than tissues surrounding the control samples. This pre-clinical study demonstrates that the IRs can be safely implanted in brain and leg tissues and that repeated, non-invasive, deep-tissue oxygen measurements can be obtained using in vivo EPR oximetry.

10.
Front Oncol ; 11: 743256, 2021.
Article in English | MEDLINE | ID: mdl-34660306

ABSTRACT

OBJECTIVE: The overall objective of this clinical study was to validate an implantable oxygen sensor, called the 'OxyChip', as a clinically feasible technology that would allow individualized tumor-oxygen assessments in cancer patients prior to and during hypoxia-modification interventions such as hyperoxygen breathing. METHODS: Patients with any solid tumor at ≤3-cm depth from the skin-surface scheduled to undergo surgical resection (with or without neoadjuvant therapy) were considered eligible for the study. The OxyChip was implanted in the tumor and subsequently removed during standard-of-care surgery. Partial pressure of oxygen (pO2) at the implant location was assessed using electron paramagnetic resonance (EPR) oximetry. RESULTS: Twenty-three cancer patients underwent OxyChip implantation in their tumors. Six patients received neoadjuvant therapy while the OxyChip was implanted. Median implant duration was 30 days (range 4-128 days). Forty-five successful oxygen measurements were made in 15 patients. Baseline pO2 values were variable with overall median 15.7 mmHg (range 0.6-73.1 mmHg); 33% of the values were below 10 mmHg. After hyperoxygenation, the overall median pO2 was 31.8 mmHg (range 1.5-144.6 mmHg). In 83% of the measurements, there was a statistically significant (p ≤ 0.05) response to hyperoxygenation. CONCLUSIONS: Measurement of baseline pO2 and response to hyperoxygenation using EPR oximetry with the OxyChip is clinically feasible in a variety of tumor types. Tumor oxygen at baseline differed significantly among patients. Although most tumors responded to a hyperoxygenation intervention, some were non-responders. These data demonstrated the need for individualized assessment of tumor oxygenation in the context of planned hyperoxygenation interventions to optimize clinical outcomes.

11.
Telemed J E Health ; 27(11): 1215-1224, 2021 11.
Article in English | MEDLINE | ID: mdl-33656918

ABSTRACT

During the COVID-19 pandemic, medical providers have expanded telehealth into daily practice, with many medical and behavioral health care visits provided remotely over video or through phone. The telehealth market was already facilitating home health care with increasing levels of sophistication before COVID-19. Among the emerging telehealth practices, telephysical therapy; teleneurology; telemental health; chronic care management of congestive heart failure, chronic obstructive pulmonary disease, diabetes; home hospice; home mechanical ventilation; and home dialysis are some of the most prominent. Home telehealth helps streamline hospital/clinic operations and ensure the safety of health care workers and patients. The authors recommend that we expand home telehealth to a comprehensive delivery of medical care across a distributed network of hospitals and homes, linking patients to health care workers through the Internet of Medical Things using in-home equipment, including smart medical monitoring devices to create a "medical smart home." This expanded telehealth capability will help doctors care for patients flexibly, remotely, and safely as a part of standard operations and during emergencies such as a pandemic. This model of "telehomecare" is already being implemented, as shown herein with examples. The authors envision a future in which providers and hospitals transition medical care delivery to the home just as, during the COVID-19 pandemic, students adapted to distance learning and adults transitioned to remote work from home. Many of our homes in the future may have a "smart medical suite" as well as a "smart home office."


Subject(s)
COVID-19 , Telemedicine , Adult , Hospitals , Humans , Pandemics , SARS-CoV-2
SELECTION OF CITATIONS
SEARCH DETAIL
...