Am J Cardiol ; 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-39019203

ABSTRACT

This study aimed to report the 5-year outcomes from the ILLUMENATE Pivotal randomized controlled trial of the lower dose (2 µg/mm2) Stellarex drug-coated balloon (DCB) (Philips, formerly Spectranetics Corp, Colorado Springs, Colorado) compared with percutaneous transluminal angioplasty (PTA) for the treatment of symptomatic peripheral arterial disease. Long-term safety and effectiveness data for DCBs remains limited. The ILLUMENATE Pivotal was a prospective, randomized, multi-center, single-blinded study. Patients (Rutherford Clinical Category 2 to 4) were randomized 2:1 to Stellarex DCB or PTA. Follow-up was through 60 months. In total, 300 patients were enrolled. The mean age was 68.8 ± 10.2 years. At 60 months, freedom from a primary safety event was 69.2% in the Stellarex DCB arm and 68.2% in the PTA arm (log-rank, p = 0.623). The cumulative rate of major adverse events was 41.0% compared with 44.6% (p = 0.597), respectively. Freedom from clinically-driven target lesion revascularization was 70.3% in the Stellarex DCB arm compared with 68.2% in the PTA arm (p = 0.505). Time to first clinically-driven target lesion revascularization was 768.3 ± 478.9 days compared with 613.5 ± 453.4 days, respectively (p = 0.161). Kaplan-Meier estimates of freedom from all-cause mortality were 80.1% in the Stellarex DCB arm and 80.2% in the PTA arm (log-rank, p = 0.980). In conclusion, the 5-year results of the ILLUMENATE Pivotal randomized controlled trial add to the consistent safety data from the broader ILLUMENATE clinical program. These are the first data to report the 5-year safety and efficacy of a lower dose (2 µg/mm2) DCB for the treatment of symptomatic peripheral arterial disease. Clinicaltrials.gov Registration:NCT01858428.

2.
J Vasc Interv Radiol ; 2024 Jun 27.
Article in English | MEDLINE | ID: mdl-38944236

ABSTRACT

PURPOSE: To Describe 6-Month safety, efficacy and multimodal imageability after imageable glass Yttrium-90 radioembolization for unresectable Hepatocellular Carcinoma (HCC) in a First-in Human Trial METHODS: Eye90 microspheres® (Eye90), an FDA Breakthrough Designated Device, are glass radiopaque Y-90 microspheres visible on CT and SPECT/CT. Six subjects with unresectable HCC underwent selective (≤ 2 segments) Eye90 treatment in a prospective open-label pilot trial. Key inclusion criteria included liver only HCC, ECOG ≤ 1, total lesion length ≤ 9 cm and Child-Pugh A. Prospective partition dosimetry was utilized. Safety, biochemistry, toxicity, adverse events (AE), multimodal imageability on CT and SPECT/CT and 3 and 6-month MRI local modified RECIST (mRECIST) response was evaluated. RESULTS: 6 subjects with HCC (7 lesions) were treated with Eye90 and followed to 180 days. Administration success was 100%. Eye90 CT radiopacity distribution correlated with SPECT/CT. Target lesion complete response was observed in 3 of 6 subjects (50%) and partial response in 2 (33.3%). Two subjects could not be assessed at 180 days. At 180 days, target lesion complete response was maintained in 3 subjects (50%) and partial response in 1 (16.7%). All subjects reported AEs, and 5 reported AEs related to treatment. There were no treatment related serious AEs. CONCLUSIONS: Eye90 was safe and effective in six subjects with unresectable HCC up to 6 months. Eye90 was imageable via CT and SPECT/CT with correlation between CT radiopacity and SPECT/CT radioactivity distribution. Eye90 provided previously unavailable CT based tumor targeting information.

3.
J Endovasc Ther ; : 15266028241234001, 2024 Feb 27.
Article in English | MEDLINE | ID: mdl-38410837

ABSTRACT

PURPOSE: To compare procedural and long-term costs associated with the use of Balloon-Expandable Covered Stents (BECS) in the management of Aortoiliac Occlusive Disease (AIOD). MATERIALS AND METHODS: A cost-consequence model was developed to simulate the intra- and post-operative management of patients with AIOD from the perspective of private health-payers. The study assessed the costs of the LifeStream (BD, Franklin Lakes, New Jersey), iCAST/Advanta V12 (Getinge, Goteborg, Sweden), BeGraft Peripheral (Bentley, Hechingen, Germany), and Viabahn Balloon Expandable (VBX) (W.L. Gore, Flagstaff, Arizona) BECS devices. Device costs were identified from the Australian Prosthesis List, whereas clinical outcomes of BECS were estimated from a systematic review of the literature. Costs were calculated over 24 and 36 month time horizons and reported in US dollars. RESULTS: Long-term, per-patient cost of each device at 24 and 36 months was $6253/$6634 for the LifeStream; $6359/$6869 for the iCAST/Advanta V12; $4806 (data available to 24 months) for the BeGraft Peripheral; and $4839/$5046 for the Viabahn VBX, respectively. Most of the cost difference was attributed to the number of stents required per treated limb and frequency of clinically-driven target lesion revascularization events. CONCLUSIONS: Best-available clinical evidence and economic modeling demonstrates that the BeGraft Peripheral and Viabahn VBX were of similar cost and the least costly options at 24 months, whereas at 36 months, the lowest cost BECS option for the treatment of AIOD was the Viabahn VBX. CLINICAL IMPACT: This analysis supports economically informed decision-making for health-payers managing systems that care for patients with AIOD. Stent length and avoiding reintervention were identified as key areas of cost-saving for future BECS development.

4.
J Vasc Surg ; 79(5): 1090-1100.e4, 2024 May.
Article in English | MEDLINE | ID: mdl-38185214

ABSTRACT

OBJECTIVE: To determine the safety and efficacy of treating abdominal aortic aneurysm (AAA) sacs with polyurethane shape memory polymer (SMP) devices during endovascular aneurysm repair (EVAR), using a technique to fully treat the target lumen after endograft placement (aortic flow volume minus the endograft volume). SMP devices self-expand in the sac to form a porous scaffold that supports thrombosis throughout its structure. METHODS: Two identical prospective, multicenter, single-arm studies were conducted in New Zealand and the Netherlands. The study population was adult candidates for elective EVAR of an infrarenal AAA (diameter of ≥55 mm in men and ≥50 mm in women). Key exclusion criteria were an inability to adequately seal a common iliac artery aneurysm, patent sac feeding vessels of >4 mm, and a target lumen volume of <20 mL or >135 mL. Target lumen volumes were estimated by subtracting endograft volumes from preprocedural imaging-based flow lumen volumes. SMP devices were delivered immediately after endograft deployment via a 6F sheath jailed in a bowed position in the sac. The primary efficacy end point was technical success, defined as filling the actual target lumen volume with fully expanded SMP at the completion of the procedure. Secondary efficacy outcome measures during follow-up were the change in sac volume and diameter, rate of type II endoleak and type I or III endoleaks, and the rate of open repair and related reinterventions, with data collection at 30 days, 6 months, and 1 year (to date). Baseline sac volumes and diameters for change in sac size analyses were determined from 30-day imaging studies. Baseline and follow-up volumes were normalized by subtraction of the endograft volume. RESULTS: Of 34 patients treated with SMP devices and followed per protocol, 33 patients were evaluable at 1 year. Preprocedural aneurysm volume was 181.4 mL (95% confidence interval [CI], 150.7-212.1 mL) and preprocedural aneurysm diameter was 60.8 mm (95% CI, 57.8-63.9 mm). The target lumen volume was 56.3 mL (95% CI, 46.9-65.8 mL). Technical success was 100% and the ratio of SMP fully expanded volume to estimated target lumen volume was 1.4 ± 0.3. Baseline normalized sac volume and diameter were 140.7 mL (95% CI, 126.6-154.9 mL) and 61.0 mm (95% CI, 59.7-62.3 mm). The adjusted mean percentage change in normalized volume at 1 year was -28.8% (95% CI, -35.3 to -22.3%; P < .001). The adjusted mean change in sac diameter at 1 year was -5.9 mm (95% CI, -7.5 to -4.4 mm; P < .001). At 1 year, 81.8% of patients (95% CI, 64.5%-93.0%) achieved a ≥10% decrease in normalized volume and 57.6% of patients (95% CI, 39.2%-74.5%) achieved a ≥5 mm decrease in diameter. No device- or study procedure-related major adverse events occurred through 1 year after the procedure. CONCLUSIONS: Treatment of AAA sacs with SMP devices during EVAR resulted in significant sac volume and diameter regression at 1 year with an acceptable safety profile in this prospective study.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Male , Humans , Female , Blood Vessel Prosthesis , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/etiology , Prospective Studies , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Aneurysm Repair , Follow-Up Studies , Treatment Outcome , Endovascular Procedures/adverse effects , Retrospective Studies , Endoleak/diagnostic imaging , Endoleak/etiology , Endoleak/surgery , Risk Factors
5.
N Engl J Med ; 390(1): 9-19, 2024 Jan 04.
Article in English | MEDLINE | ID: mdl-37888915

ABSTRACT

BACKGROUND: Among patients with chronic limb-threatening ischemia (CLTI) and infrapopliteal artery disease, angioplasty has been associated with frequent reintervention and adverse limb outcomes from restenosis. The effect of the use of drug-eluting resorbable scaffolds on these outcomes remains unknown. METHODS: In this multicenter, randomized, controlled trial, 261 patients with CLTI and infrapopliteal artery disease were randomly assigned in a 2:1 ratio to receive treatment with an everolimus-eluting resorbable scaffold or angioplasty. The primary efficacy end point was freedom from the following events at 1 year: amputation above the ankle of the target limb, occlusion of the target vessel, clinically driven revascularization of the target lesion, and binary restenosis of the target lesion. The primary safety end point was freedom from major adverse limb events at 6 months and from perioperative death. RESULTS: The primary efficacy end point was observed (i.e., no events occurred) in 135 of 173 patients in the scaffold group and 48 of 88 patients in the angioplasty group (Kaplan-Meier estimate, 74% vs. 44%; absolute difference, 30 percentage points; 95% confidence interval [CI], 15 to 46; one-sided P<0.001 for superiority). The primary safety end point was observed in 165 of 170 patients in the scaffold group and 90 of 90 patients in the angioplasty group (absolute difference, -3 percentage points; 95% CI, -6 to 0; one-sided P<0.001 for noninferiority). Serious adverse events related to the index procedure occurred in 2% of the patients in the scaffold group and 3% of those in the angioplasty group. CONCLUSIONS: Among patients with CLTI due to infrapopliteal artery disease, the use of an everolimus-eluting resorbable scaffold was superior to angioplasty with respect to the primary efficacy end point. (Funded by Abbott; LIFE-BTK ClinicalTrials.gov number, NCT04227899.).


Subject(s)
Angioplasty , Blood Vessel Prosthesis Implantation , Chronic Limb-Threatening Ischemia , Drug-Eluting Stents , Peripheral Arterial Disease , Popliteal Artery , Humans , Absorbable Implants , Angioplasty/adverse effects , Angioplasty/methods , Angioplasty, Balloon/adverse effects , Angioplasty, Balloon/methods , Blood Vessel Prosthesis Implantation/methods , Chronic Disease , Chronic Limb-Threatening Ischemia/etiology , Chronic Limb-Threatening Ischemia/surgery , Everolimus/administration & dosage , Everolimus/adverse effects , Everolimus/therapeutic use , Immunosuppressive Agents/administration & dosage , Immunosuppressive Agents/adverse effects , Immunosuppressive Agents/therapeutic use , Ischemia/drug therapy , Ischemia/etiology , Ischemia/surgery , Peripheral Arterial Disease/complications , Peripheral Arterial Disease/drug therapy , Peripheral Arterial Disease/surgery , Popliteal Artery/surgery , Tissue Scaffolds , Treatment Outcome
6.
J Vasc Interv Radiol ; 35(2): 232-240.e1, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37931844

ABSTRACT

PURPOSE: A prospective, single-arm, open-label, multicenter, first-in-human, early feasibility study was completed to evaluate the safety and performance of the GPX Embolic Device (Fluidx, Salt Lake City, Utah), a novel liquid embolic agent, for use in the peripheral vasculature when deep distal embolization is desired. MATERIALS AND METHODS: The early feasibility study evaluated the use of the device in the peripheral vasculature. Enrollment consisted of 17 patients with diverse embolization needs requiring deep distal vessel/vessel bed occlusion. Technical success, freedom from adverse events (AEs), and handling/performance characteristics were assessed with follow-up at 30 days. RESULTS: The trial enrolled 17 patients requiring distal vascular penetration of the embolic agent, including 7 with renal angiomyolipomas, 4 with renal cell carcinomas (primary and secondary), 4 with portal veins needing embolization, 1 with pelvic sarcoma, and 1 with polycystic kidney. In all cases (100%), technical success was achieved with target regions fully occluded on the first angiogram (taken immediately after delivery). Furthermore, the material received high usability ratings, as measured by a postprocedural investigator questionnaire. Most patients (15/17, 88.2%) were free from device-related severe AEs, and there were no unanticipated AEs during the study. Each patient completed a 30-day follow-up evaluation, and sites remained fully occluded in each case where imaging was available (6 [35.3%] of 17 patients had follow-up imaging where all sites were deemed occluded [100%] with a mean of 30.2 days after the procedure). CONCLUSIONS: The results of this first-in-human, early feasibility study demonstrate that the GPX Embolic Device may provide safe and effective embolization for arterial or venous applications where deep distal penetration is desired.


Subject(s)
Embolism , Embolization, Therapeutic , Ionic Liquids , Humans , Embolization, Therapeutic/adverse effects , Embolization, Therapeutic/methods , Prospective Studies , Treatment Outcome
8.
JMIR Res Protoc ; 12: e51480, 2023 Dec 04.
Article in English | MEDLINE | ID: mdl-38048145

ABSTRACT

BACKGROUND: The recommendations for the use of and selection of covered stent grafts in patients with aortoiliac occlusive disease are limited. OBJECTIVE: The GORE VBX FORWARD clinical study aims to demonstrate the superiority of the GORE VIABAHN VBX Balloon Expandable Endoprosthesis (VBX device) for primary patency when compared to bare metal stenting (BMS) for the treatment of complex iliac artery occlusive disease. METHODS: A prospective, multicenter, randomized control study in the United States, European Union, United Kingdom, Australia, and New Zealand will enroll patients with symptomatic, complex iliac artery occlusive disease. In this study, iliac artery occlusive disease is defined as a unilateral or bilateral disease with single or multiple lesions (with >50% stenosis or chronic total occlusion) each between 4 and 11 cm in length. In an attempt to more closely match real-world practices, patients with minor tissue loss (Rutherford class 5) and patients requiring hemodialysis will be included. Baseline aortoiliac angiography will be performed to assess target lesion characteristics and determine final patient eligibility. Once the patient is confirmed and guidewires are in place across the target lesions, the patient will be randomized in a 1:1 format to treatment with either the VBX device or a BMS. The BMS can be balloon- or self-expanding and must be approved for the iliac artery occlusive disease indication. Patients, the independent core laboratory reviewers, and Clinical Events Committee members will be blinded from the assigned treatment. Dual antithrombotic medical therapy is required through a minimum of 3 months post procedure. The primary end point is 12­month primary patency and will be adjudicated by an independent imaging core laboratory and Clinical Events Committee. Key secondary end points will be tested for superiority and include technical, acute procedural, and clinical success; changes in Ankle-brachial index; patient quality of life; primary patency; freedom from restenosis; primary-assisted patency; secondary patency; freedom from target lesion revascularizations; cumulative reintervention rate; amputation-free survival; survival; and change in Rutherford category. Study follow-up will continue through 5 years. RESULTS: Outcomes will be reported following study completion. Enrollment is anticipated to start in October 2023. CONCLUSIONS: The results of this study will provide definitive, level 1 clinical evidence to clinicians on the optimal choice of stent device to use for the treatment of complex iliac artery occlusive disease. The FORWARD study is powered for superiority and includes only complex, unilateral, or bilateral lesions involving the common or external iliac arteries. This study is a multidisciplinary endeavor involving vascular surgery, interventional cardiology, and interventional radiology across multiple countries with a blinded core laboratory review of end points in hopes that the outcomes will be widely accepted and incorporated into practice guidelines for optimal treatment of patients with complex iliac artery occlusive disease. TRIAL REGISTRATION: ClinicalTrials.gov NCT05811364; https://clinicaltrials.gov/study/NCT05811364. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): PRR1-10.2196/51480.

9.
J Vasc Interv Radiol ; 34(12): 2093-2102.e7, 2023 12.
Article in English | MEDLINE | ID: mdl-37460061

ABSTRACT

PURPOSE: To present the 36-month outcomes of the prospective randomized IN.PACT AV Access study of participants with obstructive de novo or restenotic native upper extremity arteriovenous dialysis fistula lesions treated with drug-coated balloon (DCBs) or standard percutaneous transluminal angioplasty (PTA) following successful high-pressure PTA. MATERIALS AND METHODS: Participants at 29 international sites were randomized 1:1 to receive an IN.PACT AV DCB (n = 170) or undergo PTA (n = 160). The outcomes through 36 months included target lesion primary patency (TLPP) and access circuit primary patency (ACPP) (composites of clinically driven target lesion or access circuit revascularization and/or access circuit thrombosis), number of reinterventions, and serious adverse events involving the access circuit. RESULTS: TLPP was 52.1% in the DCB group compared with 36.7% in the PTA group through 24 months and 43.1% in the DCB group compared with 28.6% in the PTA group through 36 months (both log-rank P < .001). ACPP was 39.4% in the DCB group compared with 25.3% in the PTA group through 24 months and 26.4% in the DCB group compared with 16.6% in the PTA group through 36 months (both log-rank P < .001). Cumulative incidence of access circuit thrombosis through 36 months was 8.2% in the DCB group compared with 18.3% in the PTA group (log-rank P = .040). Cumulative incidence of mortality through 36 months was 26.6% in the DCB group compared with 30.8% in the PTA group (log-rank P = .71). CONCLUSIONS: This study demonstrated superior TLPP and ACPP with DCBs compared with PTA, with no difference in mortality through 3 years. Access circuit thrombosis was statistically significantly higher in the PTA group at 3 years.


Subject(s)
Angioplasty, Balloon , Peripheral Arterial Disease , Thrombosis , Vascular Access Devices , Humans , Angioplasty, Balloon/adverse effects , Femoral Artery , Popliteal Artery , Prospective Studies , Coated Materials, Biocompatible , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/therapy , Time Factors , Single-Blind Method , Vascular Patency , Thrombosis/diagnostic imaging , Thrombosis/etiology , Thrombosis/therapy , Treatment Outcome
10.
J Vasc Surg Cases Innov Tech ; 9(3): 101241, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37496654

ABSTRACT

Preprocedural image analysis and intraprocedural techniques to fully treat infrarenal abdominal aortic aneurysm sacs outside of the endograft with shape memory polymer (SMP) devices during endovascular aneurysm repair were developed. Prospective, multicenter, single-arm studies were performed. SMP is a porous, self-expanding polyurethane polymer material. Target lumen volumes (aortic flow lumen volume minus endograft volume) were estimated from the preprocedural imaging studies and endograft dimensions. SMP was delivered immediately after endograft deployment via a 6F sheath jailed in a bowed position in the sac. Technical success was achieved in all cases, defined as implanting enough fully expanded SMP volume to treat the actual target lumen volume.

11.
JACC Cardiovasc Interv ; 16(13): 1654-1664, 2023 07 10.
Article in English | MEDLINE | ID: mdl-37438033

ABSTRACT

BACKGROUND: Hypoechoic peri-stent areas in duplex ultrasonography (DUS) (ie, "halo") have been noted following femoropopliteal artery stenting. OBJECTIVES: This study sought to investigate the prevalence, risk factors, and potential safety implications of hypoechoic halos identified with DUS following stent implantation in the IMPERIAL (ELUVIA Drug-Eluting Stent Versus Zilver PTX Stent) and EMINENT (Trial Comparing ELUVIA Versus Bare Metal Stent in Treatment of Superficial Femoral and/or Proximal Popliteal Artery) trials. METHODS: The IMPERIAL and EMINENT studies of femoropopliteal artery stenting included polymer-based drug-eluting stent, nonpolymer drug-coated stent, and bare metal stent treatment arms. A dedicated DUS protocol was implemented for core laboratory assessment of halo presence at study follow-up visits. Logistic regressions were used to investigate risk factors for a halo sign and its impact on clinically driven target lesion revascularization and primary patency. RESULTS: Diagnostic DUS imaging from 659 patients was obtained at time points ranging from 6 months to 5 years post-stent implantation. Halo prevalence ranged from 20% to 35% of patients with diagnostic DUS and was present at all time intervals. Halos were identified surrounding all stent types. In analyses of patients with diagnostic imaging from at least 2 visits, halo presence typically persisted, with occasional cases of regression and development at later times. No statistically significant association was found for halo status (ie, halo vs no halo) on 1-year clinically driven target lesion revascularization (OR: 1.27; 95% CI: 0.70-2.30; P = 0.4240) or primary patency (OR: 0.68; 95% CI: 0.43-1.07; P = 0.0927). CONCLUSIONS: A hypoechoic halo following a femoropopliteal stent procedure is a common occurrence associated with all studied stent types. The presence of a halo appears to be benign with no associated clinical sequelae or effect on target vessel revascularization rates within 1 year of stent implantation.


Subject(s)
Drug-Eluting Stents , Humans , Treatment Outcome , Femoral Artery/diagnostic imaging , Risk Factors , Stents
12.
J Endovasc Ther ; : 15266028231179589, 2023 Jun 14.
Article in English | MEDLINE | ID: mdl-37314243

ABSTRACT

BACKGROUND: The randomized Chocolate Touch Study demonstrated that in patients undergoing treatment of femoropopliteal artery lesions, the Chocolate Touch drug-coated balloon (DCB) was safe and had superior efficacy at 12 months compared with the Lutonix DCB. We report the prespecified diabetes subanalysis comparing outcomes among patients with and without diabetes mellitus (DM). METHODS: Patients with claudication or ischemic rest pain (Rutherford class 2-4) were randomized to Chocolate Touch or Lutonix DCB. The primary efficacy endpoint was DCB success defined as primary patency at 12 months (peak systolic velocity ratio <2.4 by duplex ultrasound without clinically driven target lesion revascularization in the absence of bailout stenting). The primary safety endpoint was freedom from major adverse events at 12 months, a composite of target limb-related death, major amputation, or reintervention. RESULTS: A total of 313 patients (38% DM [n=119]) were randomized to either Chocolate Touch (n=66/152) or Lutonix DCB (n=53/161). Among patients with DM, DCB success was 77.2% and 60.5% (p=0.08), and in non-DM patients, DCB success was 80% and 71.3% (p=0.2114) for the Chocolate Touch and Lutonix DCB, respectively. The primary safety endpoint was similar for both cohorts regardless of DM status (interaction test, p=0.96). CONCLUSIONS: This randomized trial demonstrated similar safety and efficacy for the treatment of femoropopliteal disease with the Chocolate Touch DCB compared with using the Lutonix DCB regardless of DM status at 12 months. CLINICAL IMPACT: This substudy of the Chocolate Touch Study demonstrated similar safety and efficacy for treatment of femoropopliteal disease of the Chocolate Touch DCB compared with the Lutonix DCB regardless of diabetes (DM) status at 12 months. Endovascular therapy has become the therapy of choice for the treatment of most symptomatic femoropopliteal lesions regardless of DM status. These results give clinicians another option when treating femoropopliteal disease in this high-risk patient population.

13.
J Vasc Interv Radiol ; 34(10): 1664-1673.e3, 2023 10.
Article in English | MEDLINE | ID: mdl-37302473

ABSTRACT

PURPOSE: To use safety and efficacy outcomes following treatment with percutaneous transluminal angioplasty (PTA) and/or stent placement for thoracic central venous obstruction in hemodialysis-dependent patients to establish objective performance goals (OPGs). METHODS: A systematic literature review and meta-analysis were conducted for articles published between January 1, 2000, and August 31, 2021. Efficacy outcomes included primary patency rates at 6 and 12 months, and safety outcomes included adverse events (AEs) categorized as access loss, procedure-related AEs, and serious AEs (SAEs). OPGs were derived from the upper and lower bounds of the 95% confidence intervals for primary patency and SAE rates. RESULTS: Of 66 articles reviewed, 17 met the inclusion criteria (PTA, n = 4; stent placement, n = 5; PTA/stent, n = 8). The 6- and 12-month primary patency rates for PTA were 50.9% and 36.7%, respectively. Based on these findings, the proposed 6- and 12-month primary patency OPGs identifying superiority against PTA were 66.5% and 52.6%, respectively, and those for noninferiority were 39.0% and 25.7%, respectively. For stent placement, the 6- and 12-month primary patency rates were 69.7% and 47.9%, respectively. The proposed 6- and 12-month primary patency OPGs identifying superiority were 82.1% and 64.1%, respectively, and those for noninferiority were 59.3% and 35.8%, respectively. SAE rates for PTA and stent placement were 3.8% and 8.1%, respectively. Proposed safety OPGs for noninferiority versus superiority for PTA and stent placement were 10.1% versus 1.4% and 13.6% versus 4.8%, respectively. CONCLUSION: The OPGs derived from real-world studies of PTA and stent placement may serve as a benchmark for future interventions indicated for this patient population.


Subject(s)
Angioplasty, Balloon , Vascular Diseases , Humans , Goals , Angioplasty, Balloon/adverse effects , Vascular Patency , Angioplasty , Vascular Diseases/therapy , Stents , Renal Dialysis , Treatment Outcome
14.
J Vasc Surg ; 78(4): 929-935.e1, 2023 10.
Article in English | MEDLINE | ID: mdl-37330148

ABSTRACT

OBJECTIVE: There is no proven therapy to reduce growth rates of small- to medium-sized abdominal aortic aneurysms (AAAs). Ex vivo and animal studies have demonstrated that a novel stabilizing agent, 1,2,3,4,6-pentagalloyl glucose (PGG), delivered locally to the aneurysm sac, can bind to elastin and collagen to re-establish strength and resist enzymatic degradation. We aimed to demonstrate that a one-time administration of PGG solution to the aneurysm wall is safe and potentially effective to slow the growth of small- to medium-sized AAAs. METHODS: Patients with small- to medium-sized infrarenal AAAs (maximum diameter <5.5 cm) were recruited. Via transfemoral access, a 14F or 16F dual-balloon delivery catheter was introduced into the aneurysm sac. A single, 3-minute, localized endoluminal infusion of PGG was delivered via a 'weeping' balloon to the aneurysm wall. Independent core laboratory measurements of maximum aneurysm sac diameter and sac volume measurements based on computed tomography angiography (CTA) were used for assessments at 1, 6, 12, 24, and 36 months. The primary endpoints were technical success and safety (major adverse events at 30 days). The secondary endpoint was growth stabilization, defined as freedom from aneurysm sac enlargement (diameter increase >5 mm per year or volume increase of >10% per year). RESULTS: Twenty patients (19 male) were enrolled at five centers from May 2019 to June 2022 (mean age, 67.8 years; range, 50-87 years). All procedures were technically successful. The safety profile was consistent with standard interventional procedures. Four patients demonstrated transient elevations of liver enzymes levels that returned to normal by 30 days with no clinical symptoms. Through November 2022, follow-up CTA data is available on the first 11 patients. The average changes in maximum aneurysm diameter from baseline to 6, 12, 24, and 36 months were 0.2 mm, 1.1 mm, 1.2 mm, and 0.8 mm, respectively, and the average changes in volume were 2.0%, 9.6%, 18.1%, and 11.6%, respectively. At 12 months, none of the aneurysms showed growth >5.0 mm, and three had volume growth >10%. CONCLUSIONS: The early results of this first-in-human, small cohort study demonstrated that a single, localized PGG administration to patients with small- to medium-sized infrarenal AAAs is safe. Longer term follow-up on all 20 treated patients is needed to better assess the potential impact on aneurysm growth.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Male , Aged , Pilot Projects , Cohort Studies , Aorta, Abdominal , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/etiology , Tomography, X-Ray Computed , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Treatment Outcome , Blood Vessel Prosthesis , Prosthesis Design
15.
Vascular ; : 17085381231177851, 2023 May 22.
Article in English | MEDLINE | ID: mdl-37218283

ABSTRACT

OBJECTIVES: Porous, radiolucent, shape memory polymer is a new technology available in discrete peripheral vascular embolization devices. Shape memory polymers can exist in two stable shapes; crimped for catheter delivery and expanded for vessel embolization. The expanded shape memory polymer in these new devices is hemostatic, and the porous polymeric scaffold has been shown to support tissue ingrowth and eventually bioabsorbs in preclinical animal studies. This report describes clinical experience with this novel material in vascular plug devices. METHODS: a prospective, single-arm, safety study at a single center in New Zealand with longer term follow-up via retrospective imaging review. The study device was a pushable shape memory polymer vascular plug with a distal nitinol anchor coil and a proximal radiopaque marker. RESULTS: Ten male patients were each implanted with a single shape memory polymer vascular plug. Three inferior mesenteric arteries and an accessory renal artery were embolized during endovascular aneurysm repair. An internal iliac artery was treated prior to the open surgical repair of aorto-iliac aneurysms. An internal iliac artery and a subclavian artery were embolized to treat/prophylactically address potential endoleaks. A profunda branch was embolized prior to tumor resection, and two testicular veins were embolized to treat varicoceles. Acute technical success of target vessel embolization was achieved in all implantation cases. Patients were followed for 30 days as part of the study, and no serious adverse events with a relationship to the study device occurred. No recurrent clinical symptoms attributable to treated vessel embolization or recanalization were documented. There was no evidence of recanalization on retrospective review of follow-up imaging through a mean of 22.2 months (range, <1-44 months) post-procedure. CONCLUSIONS: Shape memory polymer vascular embolization devices were safe and effective over the follow-up period of this small safety study. Further experience and longer term follow-up will assess further applicability.

16.
J Endovasc Ther ; : 15266028231165723, 2023 Apr 19.
Article in English | MEDLINE | ID: mdl-37073512

ABSTRACT

INTRODUCTION: This physician-initiated study provides 5-year (i.e., long-term) treatment durability data from 3 top recruitment sites that participated in the prospective, multicenter, nonrandomized, single-arm VBX FLEX clinical study (ClinicalTrials.gov identifier: NCT02080871). It evaluates the long-term treatment durability of the GORE VIABAHN VBX Balloon Expandable Endoprosthesis (VBX Stent-Graft) in the treatment of subjects with de novo or restenotic aortoiliac lesions. MATERIALS AND METHODS: A total of 59 subjects with 94 treated lesions were enrolled at the 3 participating sites from the original 140 intent-to-treat subjects in the VBX FLEX study. The primary durability endpoint was long-term primary patency. Secondary long-term outcomes included freedom from target lesion revascularization (TLR), freedom from target vessel revascularization (TVR), as well as resting ankle-brachial index (ABI), Rutherford category, EuroQol 5 Dimensions, and Walking Impairment status. RESULTS: Fifty-nine subjects participated and twenty-eight (47.5%) were available through the end of the study at 5-year follow-up (the median follow-up time was 6.6 years due to complications resulting from COVID-19 precautions). At 3 and 5 years, the Kaplan-Meier estimates for freedom from all-cause mortality were 94.5% and 81.7%, respectively. The Kaplan-Meier estimates for primary patency at 3 and 5 years were 94.0% and 89.5% (by lesion) and 91.7% and 84.4% (by subject). Primary assisted patency at 3 and 5 years were 93.3% and 93.3%. Kaplan-Meier estimate for freedom from TLR at 5 years was 89.1%. The majority of subjects were asymptomatic (Rutherford category 0) at 3 years (29/59; 72%), and at 5-year follow-up (18/28; 64%). The 5-year mean resting ankle-brachial index was 0.95±0.18, an improvement of 0.15±0.26 from the baseline (p<0.001). Quality of life measures also showed sustained improvement through long-term follow-up. CONCLUSION: The 5-year long-term follow-up data underscore the robustness and durability of the Viabahn Balloon-Expandable Endoprosthesis for treating aortoiliac occlusive disease. CLINICAL IMPACT: Durable improvement after endovascular treatment of iliac occlusive disease is clinically important because many of these patients are claudicants with significant life expectancy. This study is the first to evaluate the long-term outcomes in patients with iliac occlusive disease treated with the Viabahn VBX balloon-expandable endopirostheses. The study reports excellent long-term patency outcomes with prolonged clinical benefit. These durable results are likely to be an important consideration for clinicians undertaking iliac artery revascularization procedures.

17.
Cardiovasc Intervent Radiol ; 46(1): 100-111, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36450994

ABSTRACT

PURPOSE: To assess occlusion success and adverse events associated with the use of a self-expanding device for peripheral artery embolization. METHODS: This prospective, single-arm, feasibility study was conducted using the Caterpillar™ Arterial Embolization Device composed of opposing nitinol fibers and a flow-occluding membrane. Twenty patients (24 embolization sites) were treated at four investigational centers in New Zealand and Australia and followed for 30 days. Embolization sites included mesenteric, accessory renal, and iliac arteries and their branches. Primary outcome measures were peri-procedural occlusion confirmed by angiography and freedom from device-related serious adverse events (SAEs) at 30 days. Secondary observations included time to occlusion and assessment of adverse events. RESULTS: Peri-procedural occlusion was 100%, and freedom from a device-related SAE was 94.7% at 30 days. One patient had abdominal bloating that required hospitalization deemed possibly related to the device or procedure. Twenty-two of 24 embolization sites were occluded with one device (91.7%). Mean procedure duration was 11.7 ± 8.6 min (device deployment time: 1.8 ± 1.0 min), and mean fluoroscopy time was 241 ± 290.7 s. All embolization sites occluded during the procedure with 62.5% occluded within three minutes and 91.6% occluded within ten minutes. No devices migrated or required re-embolization. Freedom from device- and procedure-related adverse events was 84.2%. One patient died from aortic rupture during a subsequent adjunctive abdominal aortic endovascular procedure deemed unrelated to the embolization device or procedure. CONCLUSIONS: This first-in-human study of the Caterpillar embolization device achieved peri-procedural occlusion in all patients with a 94.7% freedom from device-related SAE at 30 days. LEVEL OF EVIDENCE: Level 2b-prospective, multicenter, single-arm, first-in-human clinical study. Pre-specified endpoints were analyzed using descriptive statistics.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Embolization, Therapeutic , Endovascular Procedures , Humans , Blood Vessel Prosthesis , Stents , Prospective Studies , Treatment Outcome , Blood Vessel Prosthesis Implantation/adverse effects , Aortic Aneurysm, Abdominal/surgery
18.
Ann Surg ; 277(2): e460-e466, 2023 02 01.
Article in English | MEDLINE | ID: mdl-33714965

ABSTRACT

OBJECTIVE: To assess the initial clinical experience with a novel endograft system (NEXUS Aortic Arch Stent Graft System) designed to treat aortic arch pathologies and address the morphology and hemodynamic challenges of the aortic arch. SUMMARY BACKGROUND DATA: The aortic arch remains the most challenging part of the aorta for both open and endovascular repair. Transcatheter aortic arch repair has the potential to significantly reduce surgical risks. METHODS: Patients underwent transcatheter aortic arch repair with a single branch, 2 stent graft system, implanted over a through-and-through guidewire from the brachiocephalic trunk, to the descending aorta with an ascending aorta stent graft. The ascending aorta stent graft is deployed into a designated docking sleeve to connect the 2 stent grafts and isolate the aortic arch pathology. Proximal landing zone in all cases was in Zone 0. Anatomical inclusion criteria included adequate landing zone in the ascending aorta, brachiocephalic trunk, and descending thoracic aorta. Preparatory debranching procedure was performed in all patients with carotid-carotid crossover bypass and left carotid to left subclavian bypass, or parallel graft from descending aorta to left subclavian artery. Safety and performance were evaluated through 1 year. Survival analysis used the Kaplan-Meier method. RESULTS: Twenty-eight patients, 79% males, with a mean age of 72.2 ± 6.2 years were treated with 100% procedural success. Isolated aortic arch aneurysm was the principle pathology in 17 (60.7%) of patients, while chronic aortic dissection was the principle pathology in 6 (21.4%) of patients. The remaining 5 (17.8%) had combined or other pathologies. At 1 month, the vascular pathology was excluded in 25 of 26 alive patients (96.1%). The 30 days mortality rate was 7.1%, stroke rate was 3.6% (all nondisabling), and combined mortality/stroke rate was 10.7%. One-year mortality was 10.7%, without device or aneurysm-related death. Two patients (7.1%) reported stroke or transient ischemic attack at 1 year that recovered completely. One year combined mortality/stroke rate was 17.8%. There were 3 patients (10.7%) that had device-related unplanned reinterventions through 1 year. CONCLUSIONS: The NEXUS Aortic Arch Stent Graft System, a novel single branch, 2 stent graft system used for endovascular aortic arch repair that requires landing in the ascending aorta, demonstrates a high success rate with excellent 1 year safety and performance.


Subject(s)
Aortic Dissection , Stroke , Male , Humans , Aged , Female , Aorta, Thoracic/surgery , Aorta , Stents , Aortic Dissection/surgery
19.
Vascular ; 31(2): 234-243, 2023 Apr.
Article in English | MEDLINE | ID: mdl-34963378

ABSTRACT

OBJECTIVE: Practice patterns and durability of parallel stent graft techniques in complex endovascular aneurysm repair (EVAR) remain poorly defined. We aimed to quantify and compare the impact of renal chimney intra-aortic stent length (IASL) on geometric deformations of renal arteries in complex EVAR. METHODS: Thirty-eight nonconsecutive patients underwent EVAR utilizing parallel stent graft techniques (chimney EVAR [chEVAR], n = 28; chimney endovascular aneurysm sealing [chEVAS], n = 10) between 2010 and 2016. A total of 59 renal chimney stent grafts were used. Geometric quantification was derived from three-dimensional model-based centerline extraction. Renal chimney intra-aortic stent length (IASL) was defined as the length of chimney stent that extended from the proximal edge of the chimney stent to the ostium of the corresponding renal artery. RESULTS: Mean IASL for both left and right renal arteries in the cohort was 35.7 mm. Renal arteries containing chimney IASL <30 mm trended toward a greater branch angle (135.4 vs. 127.8°, p = .06). Left renal arteries showed significantly greater branch angle among those with IASL <40 mm (135.5 vs. 121.7°, p = .045). Mean IASL for renal arteries in chEVAR was significantly longer compared to chEVAS (39.2 vs. 26.3 mm, p = .003). No difference was noted in overall branch angle or end-stent angle based on procedure type. ChEVAR with IASL <30 mm had significantly greater end-stent angle (48.2 vs. 33.5°, p = .03). In contrast, chEVAS patients showed no difference in end-stent angle based on IASL thresholds, but did have significantly greater branch angle among those with IASL <30 mm when grouped by both all renal arteries (133.5 vs. 113.5°, p = .004) and right renal arteries (134.3 vs. 111.6°, p = .02). CONCLUSIONS: Renal chimney stents with longer IASL appear to exhibit less renal artery deformation, suggesting a more gradual and perpendicular transition of the chimney stent across the renal ostium.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/methods , Endovascular Aneurysm Repair , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Treatment Outcome , Endovascular Procedures/adverse effects , Endovascular Procedures/methods , Aortography/methods , Stents , Prosthesis Design
20.
Eur J Cardiothorac Surg ; 63(1)2022 12 02.
Article in English | MEDLINE | ID: mdl-36484696

ABSTRACT

OBJECTIVES: Endovascular aortic arch stent grafting with branched devices has shown initial promising results. The aim of this prospective, multicentre study was to evaluate 3-year outcomes of aortic arch stent grafting with NEXUS® Aortic Arch Stent Graft System (Nexus), a single-branch, bi-modular, off-the-shelf aortic arch stent graft system in high-risk patients. METHODS: Patients treated with Nexus, either under the feasibility clinical study or as compassionate use procedures in 5 centres, were included in this study. The primary end point was overall survival. The secondary end points included the incidence of procedure-related unplanned intervention, stroke, paraplegia and endoleak. Clinical and radiologic follow-up was performed at each study site at 30 days, 6 months and on a yearly basis thereafter up to 3 years postoperatively. RESULTS: We analysed data from a total of 28 patients. The overall median follow-up was 1132 (interquartile range: 809-1537). There were no device or procedure-related deaths between 1 and 3 years. Overall survival at 1 and 3 years was 89% and 71%, respectively. The cumulative incidence of unplanned reintervention at 1 and 3 years was 11% and 29%, respectively. There were no reports of stroke, paraplegia, aneurysm rupture, myocardial infarction or new aortic valve insufficiency. In this study's 1-3 year follow-up period, 1 type Ib (4%), 1 type II (4%) and 2 type III (8%; between Nexus' distal end and Thoracic endovascular aortic repair (TEVAR) extensions) endoleak were detected. CONCLUSIONS: Endovascular aortic arch exclusion with the single-branch, off-the-shelf Nexus system provides promising clinical and radiologic results at 3-year follow-up in a high-risk patient cohort.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Stroke , Humans , Blood Vessel Prosthesis/adverse effects , Endoleak/epidemiology , Endoleak/etiology , Endovascular Aneurysm Repair , Follow-Up Studies , Prospective Studies , Postoperative Complications , Stents/adverse effects , Stroke/etiology , Treatment Outcome , Retrospective Studies