Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Insights Imaging ; 15(1): 27, 2024 Jan 25.
Article in English | MEDLINE | ID: mdl-38270689

ABSTRACT

PURPOSE: Prostate MRI is established for the investigation of patients presenting with suspected early prostate cancer. Outcomes are dependent on both image quality and interpretation. This study assessed the impact of an educational intervention on participants' theoretical knowledge of the technique. METHODS: Eighty-one clinicians from two centers with varying experience in prostate MRI participated. Baseline knowledge was assessed with 10 written and image-based multiple-choice questions (MCQs) prior to a course including didactic lectures and hands-on interactive workshops on prostate MRI interpretation. Post-course, participants completed a second 10-question MCQ test, matched by format, themes, and difficulty, to assess for any improvement in knowledge and performance. Results were assessed using the Wilcoxon rank sum test, and the Wilcoxon signed-rank test for paired data. RESULTS: Thirty-nine participants, including 25/49 (51.0%) and 14/32 (43.8%) at each center completed both assessments, with their results used for subsequent evaluation. Overall, there was a significant improvement from pre- (4.92 ± 2.41) to post-course scores (6.77 ± 1.46), p < 0.001 and at both Copenhagen (5.92 ± 2.25 to 7.36 ± 1.25) and Toronto (3.14 ± 1.51 to 5.71 ± 1.20); p = 0.005 and p = 0.002, respectively. Participants with no prostate MRI experience showed the greatest improvement (3.77 ± 1.97 to 6.18 ± 1.5, p < 0.001), followed by intermediate level (< 500 MRIs reported) experience (6.18 ± 1.99 to 7.46 ± 1.13, p = 0.058), then advanced (> 500 MRIs reported) experience (6.83 ± 2.48 to 7.67 ± 0.82, p = 0.339). CONCLUSIONS: A dedicated prostate MRI teaching course combining didactic lectures and hands-on workshops significantly improved short-term theoretical knowledge of the technique for clinicians with differing levels of experience. CRITICAL RELEVANCE STATEMENT: A dedicated teaching course significantly improved theoretical knowledge of the technique particularly for clinicians with less reporting experience and a lower baseline knowledge. The multiple-choice questions format mapped improved performance and may be considered as part of future MRI certification initiatives. KEY POINTS: • Prostate MRI knowledge is important for image interpretation and optimizing acquisition sequences. • A dedicated teaching course significantly improved theoretical knowledge of the technique. • Improved performance was more apparent in clinicians with less reporting experience and a lower baseline knowledge.

2.
Med Phys ; 2018 Jun 03.
Article in English | MEDLINE | ID: mdl-29862522

ABSTRACT

PURPOSE: Simultaneous collection of PET and MR data for radiotherapy purposes are useful for, for example, target definition and dose escalations. However, a prerequisite for using PET/MR in the radiotherapy workflow is the ability to image the patient in treatment position. The aim of this work was to adapt a GE SIGNA PET/MR scanner to image patients for radiotherapy treatment planning and evaluate the impact on signal-to-noise (SNR) of the MR images, and the accuracy of the PET attenuation correction. METHOD: A flat tabletop and a coil holder were developed to image patients in the treatment position, avoid patient contour deformation, and facilitate attenuation correction of flex coils. Attenuation corrections for the developed hardware and an anterior array flex coil were also measured and implemented to the PET/MR system to minimize PET quantitation errors. The reduction of SNR in the MR images due to the added distance between the coils and the patient was evaluated using a large homogenous saline-doped water phantom, and the activity quantitation errors in PET imaging were evaluated with and without the developed attenuation corrections. RESULT: We showed that the activity quantitation errors in PET imaging were within ±5% when correcting for attenuation of the flat tabletop, coil holder, and flex coil. The SNR of the MRI images were reduced to 74% using the tabletop, and 66% using the tabletop and coil holders. CONCLUSION: We present a tabletop and coil holder for an anterior array coil to be used with a GE SIGNA PET/MR scanner, for scanning patients in the radiotherapy work flow. Implementing attenuation correction of the added hardware from the radiotherapy setup leads to acceptable PET image quantitation. The drop in SNR in MR images may require adjustment of the imaging protocols.

SELECTION OF CITATIONS
SEARCH DETAIL
...