Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 473
Filter
1.
Article in English | MEDLINE | ID: mdl-39111697

ABSTRACT

OBJECTIVES: The pathogen of community-acquired pneumonia (CAP) in children is typically uncertain during initial treatment, leading to systematic empiric antibiotic use. This study investigates if having rapid multiplex PCR results in the emergency department (ED) improves empiric treatment. METHODS: OPTIPAC, a French multicentre study (2016-2018), enrolled patients consulting for CAP at the paediatric ED in 11 centres. Patients were randomised to either receive a multiplex PCR test plus usual care or usual care alone and followed for 15 days. The primary outcome was the appropriateness of initial antimicrobial management, determined by a blinded committee. RESULTS: Of the 499 randomised patients, 248 were tested with the multiplex PCR. Appropriateness of the antibiotic treatment was higher in the PCR group (168/245, 68.6% vs 120/249, 48.2%; RR 1.42 [1.22-1.66], P<0.0001), chiefly by reducing unnecessary antibiotics in viral pneumonia (RR 3.29 [2.20-4.90]). No adverse events were identified. CONCLUSIONS: The multiplex PCR assay result at the ED improves paediatric CAP's antimicrobial stewardship, by both reducing antibiotic prescriptions and enhancing treatment appropriateness.

2.
Liver Int ; 2024 Aug 08.
Article in English | MEDLINE | ID: mdl-39115174

ABSTRACT

BACKGROUND AND AIMS: Chronic hepatitis D infection is the most severe form of viral hepatitis and can rapidly progress to cirrhosis or hepatocellular carcinoma. Despite recommendations for systematic screening of hepatitis B surface antigen (HBsAg)-positive individuals, data from real-world studies have reported a low frequency of hepatitis D (or delta) virus (HDV) screening. Our cross-sectional analysis evaluated the diagnostic cascade for hepatitis D infection in tertiary centres and described the characteristics of HDV-positive patients. METHODS: A total of 6772 individuals who tested HBsAg positive for the first time between 2018 and 2022 were retrospectively included. Demographic, clinical and laboratory data were analysed. RESULTS: A total of 5748 HBsAg-positive individuals (84.9%) were screened for HDV infection. The screening rate varied from 63% to 97% according to the screening strategy used in the centres including or not HDV reflex testing. The prevalence of HDV infection was 6.3%. HDV RNA levels were determined in 285 of the 364 (78.3%) HDV antibody screening-positive patients, and 167 (58.6%) had active HDV infection. 66.8% were males, with a mean age of 44.9 years. A total of 97.5% were born abroad, and 92.9% were HBeAg negative. At the time of diagnosis, HDV RNA levels were 6.0 Log UI/mL; 60.1% had alanine aminotransferase >40 U/L, and 56.3% had significant fibrosis (≥F2), including 41.6% with cirrhosis. The most common genotype was HDV-1 (75.4%). Coinfections were not uncommon: 7.4% were HIV positive, and 15.0% were HCV antibody positive. CONCLUSIONS: The present study highlights the need for increased screening and monitoring of HDV infection. Reflex testing helps to identify HDV-infected individuals.

3.
J Clin Virol ; 174: 105717, 2024 Jul 24.
Article in English | MEDLINE | ID: mdl-39068746

ABSTRACT

BACKGROUND: HIV-1 resistance testing is recommended in clinical management and next-generation sequencing (NGS) methods are now available in many virology laboratories. OBJECTIVES: To evaluate the diagnostic performance of Long-Read Single Molecule Real-time (SMRT) sequencing (Sequel, PacBio) for HIV-1 polymerase genotyping. STUDY DESIGN: 111 prospective clinical samples (83 plasma and 28 leukocyte-enriched blood fraction) were analyzed for routine HIV-1 resistance genotyping using Sanger sequencing, Vela NGS, and SMRT sequencing. We developed a SMRT sequencing protocol and a bio-informatics pipeline to infer antiretroviral resistance on both haplotype and variant calling approaches. RESULTS: The polymerase was successfully sequenced by the three platforms in 98 % of plasma RNA samples for viral loads above 4 log copies/mL. The success rate decreased to 83 % using Sanger or Vela sequencing and to 67 % using SMRT sequencing for viral loads of 3 to 4 log copies/mL. Sensitivities of 50 %, 54 % and 61 % were obtained using SMRT, Vela, and Sanger sequencing, respectively, in cellular DNA from patients with prolonged undetectable plasma HIV-1 RNA. Ninety-eight percent of resistance-associated mutations (RAMs) identified with Sanger sequencing were detected using SMRT sequencing. Furthermore, 91 % of RAMs (> 5 % threshold) identified with Vela NGS were detected using SMRT sequencing. RAM quantification using Vela and SMRT sequencing was well correlated (Spearman correlation ρ = 0.82; P < 0.0001). CONCLUSIONS: SMRT sequencing of the full-length HIV-1 polymerase appeared performant for characterizing HIV-1 genotypic resistance on both RNA and DNA clinical samples. Long-read sequencing is a new tool for mutation haplotyping and resistance analysis.

5.
Biomed Pharmacother ; 177: 116988, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38897157

ABSTRACT

Therapeutic monoclonal antibodies have been successful in protecting vulnerable populations against SARS-CoV-2. However, their effectiveness has been hampered by the emergence of new variants. To adapt the therapeutic landscape, health authorities have based their recommendations mostly on in vitro neutralization tests. However, these do not provide a reliable understanding of the changes in the dose-effect relationship and how they may translate into clinical efficacy. Taking the example of EvusheldTM (AZD7442), we aimed to investigate how in vivo data can provide critical quantitative results and project clinical effectiveness. We used the Golden Syrian hamster model to estimate 90 % effective concentrations (EC90) of AZD7442 in vivo against SARS-CoV-2 Omicron BA.1, BA.2 and BA.5 variants. While our in vivo results confirmed the partial loss of AZD7442 activity for BA.1 and BA.2, they showed a much greater loss of efficacy against BA.5 than that obtained in vitro. We analyzed in vivo EC90s in perspective with antibody levels measured in a cohort of immunocompromised patients who received 300 mg of AZD7442. We found that a substantial proportion of patients had serum levels of anti-SARS-CoV-2 spike protein IgG above the estimated in vivo EC90 for BA.1 and BA.2 (21 % and 92 % after 1 month, respectively), but not for BA.5. These findings suggest that AZD7442 is likely to retain clinical efficacy against BA.2 and BA.1, but not against BA.5. Overall, the present study illustrates the importance of complementing in vitro investigations by preclinical studies in animal models to help predict the efficacy of monoclonal antibodies in humans.


Subject(s)
Antibodies, Monoclonal , COVID-19 , Mesocricetus , SARS-CoV-2 , Animals , SARS-CoV-2/immunology , SARS-CoV-2/drug effects , Antibodies, Monoclonal/pharmacology , Antibodies, Monoclonal/immunology , COVID-19/immunology , COVID-19/virology , Humans , Cricetinae , COVID-19 Drug Treatment , Female , Antibodies, Viral/blood , Antibodies, Viral/immunology , Antibodies, Monoclonal, Humanized/pharmacology , Antibodies, Monoclonal, Humanized/therapeutic use , Male , Disease Models, Animal , Betacoronavirus/immunology , Betacoronavirus/drug effects , Drug Evaluation, Preclinical/methods , Antiviral Agents/pharmacology , Antiviral Agents/therapeutic use
7.
J Virol ; 98(6): e0029524, 2024 Jun 13.
Article in English | MEDLINE | ID: mdl-38712945

ABSTRACT

Hepatitis E virus is a single-strand, positive-sense RNA virus that can lead to chronic infection in immunocompromised patients. Virus-host recombinant variants (VHRVs) have been described in such patients. These variants integrate part of human genes into the polyproline-rich region that could introduce new post-translational modifications (PTMs), such as ubiquitination. The aim of this study was to characterize the replication capacity of different VHRVs, namely, RNF19A, ZNF787, KIF1B, EEF1A1, RNA18, RPS17, and RPL6. We used a plasmid encoding the Kernow strain, in which the fragment encoding the S17 insertion was deleted (Kernow p6 delS17) or replaced by fragments encoding the different insertions. The HEV RNA concentrations in the supernatants and the HepG2/C3A cell lysates were determined via RT-qPCR. The capsid protein ORF2 was immunostained. The effect of ribavirin was also assessed. The HEV RNA concentrations in the supernatants and the cell lysates were higher for the variants harboring the RNF19A, ZNF787, KIF1B, RPS17, and EEF1A1 insertions than for the Kernow p6 del S17, while it was not with RNA18 or RPL6 fragments. The number of ORF2 foci was higher for RNF19A, ZNF787, KIF1B, and RPS17 than for Kernow p6 del S17. VHRVs with replicative advantages were less sensitive to the antiviral effect of ribavirin. No difference in PTMs was found between VHRVs with a replicative advantage and those without. In conclusion, our study showed that insertions did not systematically confer a replicative advantage in vitro. Further studies are needed to determine the mechanisms underlying the differences in replicative capacity. IMPORTANCE: Hepatitis E virus (HEV) is a major cause of viral hepatitis. HEV can lead to chronic infection in immunocompromised patients. Ribavirin treatment is currently used to treat such chronic infections. Recently, seven virus-host recombinant viruses were characterized in immunocompromised patients. These viruses have incorporated a portion of a human gene fragment into their genome. We studied the consequences of these insertions on the replication capacity. We found that these inserted fragments could enhance virus replication for five of the seven recombinant variants. We also showed that the recombinant variants with replicative advantages were less sensitive to ribavirin in vitro. Finally, we found that the mechanisms leading to such a replicative advantage do not seem to rely on the post-translational modifications introduced by the human gene fragment that could have modified the function of the viral protein. The mechanisms involved in improving the replication of such recombinant viruses remain to be explored.


Subject(s)
Hepatitis E virus , Host Microbial Interactions , Recombination, Genetic , Humans , Antiviral Agents/pharmacology , Hep G2 Cells , Hepatitis E/genetics , Hepatitis E/virology , Hepatitis E virus/classification , Hepatitis E virus/drug effects , Hepatitis E virus/genetics , Hepatitis E virus/growth & development , Protein Processing, Post-Translational , Ribavirin/pharmacology , RNA, Viral/genetics , RNA, Viral/metabolism , Virus Replication/drug effects , Virus Replication/genetics , Host Microbial Interactions/genetics , Ubiquitination/genetics , Plasmids/genetics
8.
J Med Virol ; 96(5): e29652, 2024 May.
Article in English | MEDLINE | ID: mdl-38727029

ABSTRACT

Human papillomavirus (HPV) genotyping is widely used, particularly in combination with high-risk (HR) HPV tests for cervical cancer screening. We developed a genotyping method using sequences of approximately 800 bp in the E6/E7 region obtained by PacBio single molecule real-time sequencing (SMRT) and evaluated its performance against MY09-11 L1 sequencing and after the APTIMA HPV genotyping assay. The levels of concordance of PacBio E6/E7 SMRT sequencing with MY09-11 L1 sequencing and APTIMA HPV genotyping were 100% and 90.8%, respectively. The sensitivity of PacBio E6/EA7 SMRT was slightly greater than that of L1 sequencing and, as expected, lower than that of HR-HPV tests. In the context of cervical cancer screening, PacBio E6/E7 SMRT is then best used after a positive HPV test. PacBio E6/E7 SMRT genotyping is an attractive alternative for HR and LR-HPV genotyping of clinical samples. PacBio SMRT sequencing provides unbiased genotyping and can detect multiple HPV infections and haplotypes within a genotype.


Subject(s)
Genotype , Genotyping Techniques , Papillomaviridae , Papillomavirus Infections , Humans , Papillomavirus Infections/virology , Papillomavirus Infections/diagnosis , Female , Genotyping Techniques/methods , Papillomaviridae/genetics , Papillomaviridae/classification , Papillomaviridae/isolation & purification , Sensitivity and Specificity , Uterine Cervical Neoplasms/virology , Uterine Cervical Neoplasms/diagnosis , Sequence Analysis, DNA/methods , Early Detection of Cancer/methods , Oncogene Proteins, Viral/genetics , DNA, Viral/genetics , High-Throughput Nucleotide Sequencing/methods
9.
Exp Clin Transplant ; 22(4): 267-269, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38742316

ABSTRACT

OBJECTIVES: BK virus is a major cause of chronic renal allograft failure.Transplant ureteral stent use has been reported as a risk factorfor BK virus infection. Recently, the use of a new type of ureteral stent (Magnetic Black Star) was reported in kidney transplant recipients. The aim ofthis preliminary report was to compare BK virus viremia and viruria occurrence depending on the type of double-J stent (standard versus Magnetic Black Star). MATERIALS AND METHODS: We included all kidney transplants performed in our center from January to December 2022. Each case had double-J stent placement. Indwelling stents were either a 6- or 7-Fr standard double-J stent or a 6-Fr Magnetic Black Star double-J stent. The type of double-J stent was chosen according to the surgeon's preference. A standard BK virus screening protocol was followed during the study period, which consisted of routine polymerase chain reaction examination of plasma and urine samples during monthly follow-ups. RESULTS: We assessed 120 patients without missing data: 92 patients received standard double-J stents and 28 patients received Magnetic Black Star stents. Patients were mostly male in the standard group (70.7%) versus the Magnetic Black Star group (42.9%) (P = .01). ABO- and HLA-incompatible transplant rates were similar in both groups. BK viremia occurrence and BK viruria occurrence were similar between groups at 1 month, 3 months, and 6 months. CONCLUSIONS: This preliminary study showed no differences concerning BKvirus infection depending on the type of double-J stents used during kidney transplant.


Subject(s)
BK Virus , Kidney Transplantation , Polyomavirus Infections , Prosthesis Design , Stents , Tumor Virus Infections , Viremia , Humans , Kidney Transplantation/adverse effects , BK Virus/pathogenicity , BK Virus/immunology , Male , Viremia/diagnosis , Viremia/virology , Female , Middle Aged , Polyomavirus Infections/virology , Polyomavirus Infections/diagnosis , Polyomavirus Infections/immunology , Polyomavirus Infections/urine , Risk Factors , Treatment Outcome , Adult , Tumor Virus Infections/virology , Tumor Virus Infections/diagnosis , Tumor Virus Infections/immunology , Tumor Virus Infections/urine , Time Factors , Preliminary Data , Retrospective Studies
11.
J Virol Methods ; 327: 114920, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38574772

ABSTRACT

INTRODUCTION: We evaluated the performance of the automated Altostar HEV RNA platform for detecting HEV RNA. METHODS AND RESULTS: Clinical performance was determined by testing 81 plasma samples and 10 fecal samples manually quantified previously with the Realstar RT-PCR assay using the Magnapure instrument for extraction. The assays were concordant for 79/81 plasma samples (97.5%) and 10/10 (100%) fecal samples. The two plasma samples that tested negative with the Altostar assay had a very low HEV RNA concentration (1.6 and 1.4 log10 IU/ml). Quantitative results obtained with the automated platform and the manual workflow were highly correlated (ρ= 0.98, p<0.01). The intra-run and inter-run standard deviation were 0.09 IU/ml and 0.13 IU/ml respectively. The assay was linear from 2 to 6 log IU/ml. The limit of detection determined by Probit analysis with the WHO HEV RNA standard was 7.6 [95% CI: 4.4-52.5] IU/ml. CONCLUSIONS: The Altostar platform enables highly accurate testing for the detection of HEV RNA in stool and the quantification of HEV RNA in plasma. This allowed us to shorten turnaround times and to save time for the technical staff.


Subject(s)
Automation, Laboratory , Feces , Hepatitis E virus , Hepatitis E , RNA, Viral , Feces/virology , Humans , RNA, Viral/isolation & purification , RNA, Viral/blood , RNA, Viral/analysis , RNA, Viral/genetics , Hepatitis E virus/isolation & purification , Hepatitis E virus/genetics , Hepatitis E/diagnosis , Hepatitis E/virology , Hepatitis E/blood , Sensitivity and Specificity , Plasma/virology , Molecular Diagnostic Techniques/methods
12.
Am J Trop Med Hyg ; 110(6): 1210-1213, 2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38653231

ABSTRACT

We explored the association between serological status for hepatitis E and neurocysticercosis (NCC) in neurologic patients attending a national neurological referral center in Lima, Perú, between the years 2008 and 2012. Anti-hepatitis E antibodies were evaluated in patients with and without NCC, and a control group of rural general population. Anti-hepatitis E IgG was found in 23.8% of patients with NCC, compared with 14.3% in subjects without NCC from a general rural population (P = 0.023) and 14.4% in subjects with neurological complaints without NCC (P = 0.027). Seropositive patients had a median age of 44 years compared with 30 years in seronegative patients (P <0.001). No significant differences in sex, region of residence, or liver enzyme values were found. Seropositivity to hepatitis E was frequent in this Peruvian population and higher in patients with NCC, suggesting shared common routes of infection.


Subject(s)
Hepatitis E virus , Hepatitis E , Neurocysticercosis , Humans , Neurocysticercosis/epidemiology , Neurocysticercosis/immunology , Neurocysticercosis/complications , Male , Adult , Female , Hepatitis E/epidemiology , Hepatitis E/immunology , Hepatitis E virus/immunology , Middle Aged , Peru/epidemiology , Young Adult , Prevalence , Immunoglobulin G/blood , Hepatitis Antibodies/blood , Seroepidemiologic Studies , Adolescent , Aged
13.
Heliyon ; 10(7): e29116, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38601689

ABSTRACT

Our understanding of cellular immunity in response to COVID-19 infection or vaccination is limited because of less commonly used techniques. We investigated both the cellular and humoral immune responses before and after the administration of a third dose of the SARS-CoV-2 vaccine among a group of healthcare workers. Cellular immunity was evaluated using the VIDAS interferon-gamma (IFNγ) RUO test, which enables automated measurement of IFNγ levels after stimulating peripheral blood lymphocytes. Booster doses significantly enhanced both cellular and humoral immunity. Concerning cellular response, the booster dose increased the percentage of positive IFNγ release assay (IGRA) results but no difference in IFNγ release was found. The cellular response was not associated with protection against SARS-CoV-2 infection. Interestingly, vaccinated and infected healthcare workers exhibited the highest levels of anti-spike and neutralizing antibodies. In conclusion, the IGRA is a simple method for measuring cellular immune responses after vaccination. However, its usefulness as a complement to the study of humoral responses is yet to be demonstrated in future research.

14.
Transpl Infect Dis ; 26(2): e14260, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38547002

ABSTRACT

INTRODUCTION: As there is no specific antiviral treatment currently available for BK polyomavirus associated nephropathy (BKVAN), its management relies on immunosuppression reduction in kidney transplant patients. Data on efficacy of steroid pulses in this indication are lacking. METHODS: We performed a retrospective monocenter study on 64 patients diagnosed with biopsy-proven BKVAN. Patients within the "pulse group" (n = 37) received IV methylprednisolone 10 mg/kg 3 days consecutively. In the "low dose" steroid group (n = 27), patients were continued oral prednisone 5 mg daily. RESULTS: Mean follow up was 78 months in the steroid pulse group and 56 months in the low dose group (p = 0.15). Mean eGFR values at diagnosis were comparable, as well as other demographic characteristics. Mean BK plasma viral load was higher in "pulse" than in "low dose" steroid group. Pulse group had higher inflammation and tubulitis (p < 0.05). Graft loss reached 57% in the "pulse" group versus 41% in the "low dose" group, p = 0.20. Rejection events were similar. No major adverse event was statistically associated with steroid pulse, including infections, cancer, and de novo diabetes. CONCLUSION: No significant differences were found in the evolution of both groups of patients, despite patients receiving "pulse" steroids were identified as the most severe sharing higher BK viral load and more frequent active lesions on histology.


Subject(s)
BK Virus , Kidney Diseases , Nephritis, Interstitial , Polyomavirus Infections , Tumor Virus Infections , Humans , Retrospective Studies , Nephritis, Interstitial/pathology , Allografts/pathology , Inflammation , Steroids/therapeutic use , Polyomavirus Infections/diagnosis , Tumor Virus Infections/diagnosis , Graft Rejection/drug therapy
16.
EBioMedicine ; 100: 104954, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38160480

ABSTRACT

BACKGROUND: The persistence of intact replication-competent HIV-1 proviruses is responsible for the virological rebound off treatment. The gut could be a major reservoir of HIV-1 due to the high number of infected target cells. METHODS: We collected blood samples and intestinal biopsies (duodenum, ileum, colon) from 42 people with HIV-1 receiving effective antiretroviral therapy. We used the Intact Proviral DNA Assay to estimate the frequency of intact HIV-1 proviruses in the blood and in the intestinal mucosa of these individuals. We analyzed the genetic complexity of the HIV-1 reservoir by performing single-molecule next-generation sequencing of HIV-1 env DNA. The activation/exhaustion profile of mucosal T lymphocytes was assessed by flow cytometry. FINDINGS: Intact proviruses are particularly enriched in the colon. Residual HIV-1 transcription in the gut is associated with persistent mucosal and systemic immune activation. The HIV-1 intestinal reservoir appears to be shaped by the proliferation of provirus-hosting cells. The genetic complexity of the viral reservoir in the colon is positively associated with TIGIT expression but negatively with PD-1, and inversely related to its intact content. The size of the intact reservoir in the colon is associated with PD-1+TIGIT- mucosal CD4+ T cells, particularly in CD27+ memory cells, whose proliferation and survival could contribute to the enrichment of the viral reservoir by intact proviruses. INTERPRETATION: Enrichment in intact proviruses makes the gut a key compartment for HIV-1 persistence on antiretroviral therapy. FUNDING: This project was supported by grants from the ANRS-MIE (ANRS EP61 GALT), Sidaction, and the Institut Universitaire de France.


Subject(s)
HIV Infections , HIV Seropositivity , HIV-1 , Humans , Proviruses/genetics , HIV-1/genetics , Programmed Cell Death 1 Receptor/genetics , Programmed Cell Death 1 Receptor/metabolism , CD4-Positive T-Lymphocytes , HIV Seropositivity/metabolism , Receptors, Immunologic/metabolism , DNA/metabolism , Colon/metabolism , DNA, Viral/genetics , DNA, Viral/metabolism , Viral Load
17.
J Med Virol ; 95(12): e29283, 2023 12.
Article in English | MEDLINE | ID: mdl-38088528

ABSTRACT

In cervical cancer screening programs, the detection of high-risk human papillomavirus (HR-HPV) is now widely implemented on physician-collected samples and has expanded to include self-collected samples. The use of a cellularity control (CC) is needed to reduce false-negative HPV results. An external mRNA CC for the HPV APTIMA® assay was assessed for its analytical performance and the results were compared with both cervix cytobrush samples taken by physicians and self-collected vaginal samples from 148 women. The performance of the CC was adjusted to control for the presence of cellular mRNA in the ThinPrep® and Multitest® transport media. This CC is user-friendly but implies to perform two independent assays on PANTHER® automate. Self-collected vaginal sampling gives a lower median CC results (13.2 vs. 16.9 min) but a higher risk of negative CC results (3.3 vs. 0%). The usefulness of the CC for the HR-HPV assay may be optimized by the definition of a threshold for a minimum cell number to be tested to increase confidence in HPV-negative results. The systematic use of an RNA CC increases confidence for HPV RNA assays on self-collected vaginal samples.


Subject(s)
Papillomavirus Infections , Uterine Cervical Dysplasia , Uterine Cervical Neoplasms , Female , Humans , Uterine Cervical Neoplasms/diagnosis , Papillomavirus Infections/diagnosis , Sensitivity and Specificity , Vaginal Smears/methods , Early Detection of Cancer/methods , Papillomaviridae/genetics , RNA, Messenger/genetics , Specimen Handling/methods , Human Papillomavirus Viruses
19.
Diagn Microbiol Infect Dis ; 107(4): 116071, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37716217

ABSTRACT

Pre-exposure prophylaxis (PrEP) is crucial to prevent severe COVID-19 in immunocompromised patients. A reliable method is needed to quantify anti-SARS-CoV-2 antibody levels for personalized monitoring during PrEP. We measured the binding antibody concentrations of 63 immunocompromised patients receiving 300mg or 600mg tixagevimab/cilgavimab on PrEP day and twice during the following 3 months. All blood samples were tested using the Abbott anti-SARS-CoV-2 IgG II Quant assay, the Roche Elecsys anti-SARS-CoV-2 S assay, and live virus-based neutralization assays. The results of the two immunoassays were correlated on day 0, 1 month, and 3 months post-PrEP. Passing-Bablok regression demonstrated higher anti-S concentration values measured with the Roche immunoassay compared to those measured with the Abbott immunoassay. Antibody concentrations were higher after 600 mg tixagevimab/cilgavimab prophylaxis than after 300 mg. The neutralizing antibody titers obtained using the omicron BA.5 and BA.2.75 strains were low. Both automated immunoassays are suitable for monitoring immunocompromised patients on PrEP.


Subject(s)
COVID-19 , Pre-Exposure Prophylaxis , Humans , COVID-19/diagnosis , COVID-19/prevention & control , Antibodies, Viral , Immunoassay , Biological Assay
20.
Vaccines (Basel) ; 11(6)2023 Jun 12.
Article in English | MEDLINE | ID: mdl-37376484

ABSTRACT

The vaccines presently available are less effective in older people due to senescence of their immune systems. We measured the antibody responses of 42 adults living in nursing homes after the third and the fourth doses of an mRNA vaccine and found that the strain (BA.2 and BA.2.75: from 64 to 128, BA.5: from 16 to 32, BQ.1.1: from 16 to 64 among the uninfected) influenced the effect of the fourth dose of vaccine on neutralizing antibodies. The fourth dose also increased binding antibodies (from 1036 BAU/mL to 5371 BAU/mL among the uninfected, from 3700 BAU/mL to 6773 BAU/mL among the BA.5 infected). This effect was less significant than that of the third dose of vaccine for both neutralizing (BA.2: from 8 to 128, BA.5: from 2 to 16, BA.2.75: from 8 to 64, BQ.1.1: from 2 to 16) and binding antibodies (from 139.8 BAU/mL to 2293 BAU/mL). However, the fourth dose attained the 5000 BAU/mL threshold conferring approximately 80% protection against a SARS-CoV-2 BA.2 infection in most individuals, unlike the third.

SELECTION OF CITATIONS
SEARCH DETAIL