Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 57
Filter
1.
AJNR Am J Neuroradiol ; 44(6): 668-674, 2023 06.
Article in English | MEDLINE | ID: mdl-37169543

ABSTRACT

BACKGROUND AND PURPOSE: Bioresorbable flow diverters are under development to mitigate complications associated with conventional flow-diverter technology. One proposed advantage is the ability to reduce metal-induced artifacts in follow-up medical imaging. In the current work, the medical imaging compatibility of magnesium- and iron-based bioresorbable flow diverters is assessed relative to an FDA-approved control in phantom models. MATERIALS AND METHODS: Bioresorbable flow diverters, primarily composed of braided magnesium or antiferromagnetic iron alloy wires, were compared with an FDA-approved control flow diverter. The devices were assessed for MR imaging safety in terms of magnetically induced force and radiofrequency heating using 1.5T, 3T, and 7T field strength clinical scanners. The devices were deployed in phantom models, and metal-induced image artifacts were assessed in the 3 MR imaging scanners and a clinical CT scanner following clinical scan protocols; device visibility was assessed under fluoroscopy. RESULTS: The magnesium-based bioresorbable flow diverter, iron-based bioresorbable flow diverter, and the control device all demonstrated MR imaging safety in terms of magnetically induced force and radiofrequency heating at all 3 field strengths. The bioresorbable flow diverters did not elicit excessive MR imaging artifacts at any field strength relative to the control. Furthermore, the bioresorbable flow diverters appeared to reduce blooming artifacts in CT relative to the control. The iron-based bioresorbable flow diverter and control device were visible under standard fluoroscopy. CONCLUSIONS: We have demonstrated the baseline medical imaging compatibility of magnesium and antiferromagnetic iron alloy bioresorbable flow diverters. Future work will evaluate the medical imaging characteristics of the bioresorbable flow diverters in large-animal models.


Subject(s)
Intracranial Aneurysm , Animals , Intracranial Aneurysm/diagnostic imaging , Magnesium , Iron , Absorbable Implants , Radiography , Alloys
2.
AJNR Am J Neuroradiol ; 43(5): 741-747, 2022 05.
Article in English | MEDLINE | ID: mdl-35483907

ABSTRACT

BACKGROUND AND PURPOSE: Intracranial aneurysms treated with coils have been associated with incomplete occlusion, particularly in large or wide-neck aneurysms. This study aimed to validate the accuracy of the rabbit elastase model in predicting aneurysm recurrence in humans treated with platinum coils. MATERIALS AND METHODS: Elastase-induced saccular aneurysms were induced in rabbits and embolized with conventional platinum coils. The recurrence rates of aneurysms were retrospectively analyzed. Morphologic characteristics of aneurysms, angiographic outcomes, and histologic healing were evaluated. RESULTS: A total of 28 (15.3%) of 183 aneurysms recurred. The aneurysm recurrence rate observed in this study (15.3%) is similar to those reported in multiple analyses of aneurysm recurrence rates in humans (7%-27%). The rate of recurrence was higher in aneurysms treated without balloon assistance (19/66, 28.8%) compared with those treated with balloon assistance (9/117, 7.7%). Aneurysms treated with balloon-assisted coiling had a lower recurrence rate (OR = 0.17; 95% CI, 0.05-0.47; P = .001) and higher occlusion rate (OR = 6.88; 95% CI, 2.58-20.37; P < .001) compared with those treated without balloon-assisted coiling. In this rabbit elastase-induced aneurysm model, packing density and aneurysm volume were weak predictors of aneurysm recurrence; however, the packing density was a good predictor of the occlusion rate (OR = 1.05; 95% CI, 1.02-1.10; P = .008). CONCLUSIONS: The rabbit elastase aneurysm model may mimic aneurysm recurrence rates observed in humans after platinum coil embolization. Moreover, balloon assistance and high packing densities were significant predictors of aneurysm recurrence and occlusion.


Subject(s)
Embolization, Therapeutic , Intracranial Aneurysm , Animals , Humans , Intracranial Aneurysm/chemically induced , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/therapy , Pancreatic Elastase , Platinum/adverse effects , Rabbits , Recurrence , Retrospective Studies , Treatment Outcome
3.
AJNR Am J Neuroradiol ; 43(2): 251-257, 2022 02.
Article in English | MEDLINE | ID: mdl-35027348

ABSTRACT

BACKGROUND AND PURPOSE: Aspiration thrombectomy has become a preferred approach to recanalize large-vessel occlusion in stroke with a growing trend toward using larger-bore catheters and stronger vacuum pumps. However, the mechanical response of the delicate cerebral arteries to aspiration force has not been evaluated. Here, we provide preclinical and clinical evidence of intracranial arterial collapse in aspiration thrombectomy. MATERIALS AND METHODS: We presented a clinical case of arterial collapse with previously implanted flow diverters. We then evaluated the effect of vacuum with conventional aspiration catheters (with and without stent retrievers) in a rabbit model (n = 3) using fluoroscopy and intravascular optical coherence tomography. Then, in a validated human cadaveric brain model, we conducted 168 tests of direct aspiration thrombectomy following an experimental design modifying the catheter inner diameter (0.064 inch, 0.068 inch, and 0.070 inch), cerebral perfusion pressures (mean around 60 and 90 mm Hg), and anterior-versus-posterior circulation. Arterial wall response was recorded and graded via direct transluminal observation. RESULTS: Arterial collapse was observed in both the patient and preclinical experimental models. In the human brain model, arterial collapse was observed in 98% of cases in the M2 and in all the cases with complete proximal flow arrest. A larger bore size of the aspiration catheter, a lower cerebral perfusion pressure, and the posterior circulation in comparison with the anterior circulation were associated with a higher probability of arterial collapse. CONCLUSIONS: Arterial collapse does occur during aspiration thrombectomy and is more likely to happen with larger catheters, lower perfusion pressure, and smaller arteries.


Subject(s)
Stroke , Thrombectomy , Animals , Brain/diagnostic imaging , Brain/surgery , Catheters , Cerebral Arteries/diagnostic imaging , Cerebral Arteries/surgery , Humans , Rabbits , Stents , Stroke/diagnostic imaging , Stroke/surgery , Thrombectomy/methods , Treatment Outcome
4.
AJNR Am J Neuroradiol ; 43(2): 258-264, 2022 02.
Article in English | MEDLINE | ID: mdl-34916206

ABSTRACT

Endovascular treatment of aneurysms with flow diverters or coiling is sometimes complicated by intraprocedural or postprocedural thrombosis along or within the devices. Thrombus composition and structure associated with such complications may provide insights into mechanisms of thrombus formation and clinical strategies to remove the thrombus. We present a retrospective histopathologic study of 4 patients who underwent mechanical thrombectomy due to acute occlusion of either implanted flow diverter devices or along coils during the treatment of intracranial aneurysm.


Subject(s)
Embolization, Therapeutic , Endovascular Procedures , Intracranial Aneurysm , Thrombosis , Embolization, Therapeutic/adverse effects , Endovascular Procedures/adverse effects , Humans , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/surgery , Retrospective Studies , Stents/adverse effects , Thrombosis/diagnostic imaging , Thrombosis/etiology , Treatment Outcome
5.
AJNR Am J Neuroradiol ; 42(11): 1968-1972, 2021 11.
Article in English | MEDLINE | ID: mdl-34556479

ABSTRACT

BACKGROUND AND PURPOSE: The persistent challenges in thrombectomy for large-vessel occlusion, such as suboptimal complete recanalization and first-pass effect imply an insufficient understanding of the artery-clot-device interaction. In this study, we present a thrombectomy model using fresh human brains, which can capture the artery-clot-device interaction through concurrent transmural and angiographic visualizations. MATERIALS AND METHODS: Fresh nonfrozen whole adult human brains were collected and connected to a customized pump system tuned to deliver saline flow at a physiologic flow rate and pressure. Angiography was performed to verify the flow in the anterior-posterior and vertebrobasilar circulations and collaterals. Large-vessel occlusion was simulated by embolizing a radiopaque clot analog. Thrombectomy was tested, and the artery-clot-device interactions were recorded by transmural and angiographic videos. RESULTS: Baseline cerebral angiography revealed excellent penetration of contrast in the anterior-posterior and vertebrobasilar circulations without notable arterial cutoffs and with robust collaterals. Small branches (<0.5 mm) and perforating arteries were consistently opacified with good patency. Three device passes were performed to achieve recanalization, with failure modes including elongation, fragmentation, and distal embolization. CONCLUSIONS: This model enables concurrent transmural and angiographic analysis of artery-clot-device interaction in a human brain and provides critical insights into the action mechanism and failure modes of current and upcoming thrombectomy devices.


Subject(s)
Embolization, Therapeutic , Stroke , Thrombosis , Brain/diagnostic imaging , Brain/surgery , Humans , Stroke/therapy , Thrombectomy , Treatment Outcome
6.
AJNR Am J Neuroradiol ; 42(11): 1973-1978, 2021 11.
Article in English | MEDLINE | ID: mdl-34446459

ABSTRACT

BACKGROUND AND PURPOSE: Identifying and predicting which aneurysms are likely to quickly occlude and which ones are likely to remain open following treatment with flow-diverting devices is important to develop optimal patient management strategies. The purpose of this study was to evaluate predictions based on computational fluid dynamics models using the elastase rabbit aneurysm model. MATERIALS AND METHODS: A series of 13 aneurysms created in rabbits were treated with flow diverters, and outcomes were angiographically assessed at 8 weeks' follow-up. Computational fluid dynamics models were constructed from pretreatment 3D rotational angiograms and Doppler ultrasound flow velocity measurements. Postimplantation mean aneurysm inflow rate and flow velocity were used to prospectively predict aneurysm occlusion blinded to the actual outcomes. Specifically, if both variables were below their corresponding thresholds, fast occlusion was predicted, while if one of them was above the threshold, slow or incomplete occlusion was predicted. RESULTS: Of the 13 aneurysms included, 8 were incompletely occluded 8 weeks after treatment, and 5 were completely occluded. A total of 10 computational fluid dynamics-based predictions agreed with the angiographic outcome, reaching 77% accuracy, 80% sensitivity, and 75% specificity. Posttreatment mean velocity alone was able to achieve the same predictive power as the combination of inflow rate and velocity. CONCLUSIONS: Subject-specific computational fluid dynamics models of the hemodynamic conditions created immediately after implantation of flow-diverting devices in experimental aneurysms created in rabbits are capable of prospectively predicting, with a reasonable accuracy, which aneurysms will completely occlude and which ones will remain incompletely occluded.


Subject(s)
Intracranial Aneurysm , Animals , Hemodynamics , Hydrodynamics , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/surgery , Pancreatic Elastase , Prognosis , Rabbits , Treatment Outcome
7.
AJNR Am J Neuroradiol ; 42(7): 1239-1249, 2021 07.
Article in English | MEDLINE | ID: mdl-34255735

ABSTRACT

BACKGROUND AND PURPOSE: Hydrophilic polymers and polytetrafluoroethylene liners, commonly used in the construction of endovascular devices, occasionally separate from devices with subsequent embolization. We determined the frequency of such materials in thrombus specimens retrieved by mechanical thrombectomy in patients with stroke. MATERIALS AND METHODS: We retrospectively reviewed H&E-stained thrombus sections for presence and types of foreign materials. We identified 4 types of foreign materials-Type I: material was light green with refraction and had a homogeneous texture; type II: material was light gray and/or dark gray, thin, and loose or attenuated in texture; type III: material was light green with refraction, solitary in texture, irregular in shape, and was often associated with round or oval bubblelike particles and/or diffuse black particles; and type IV: material had homogeneous texture and was light pink or red. In addition, polymer materials from different layers of used mechanical thrombectomy catheters were compared with the foreign materials found in thrombus specimens. RESULTS: A total of 101 thrombi were evaluated. Foreign materials were found in 53 (52.5%) thrombus samples. The most common type was type I (92%), followed by type II (30%). The histopathologic features of the polymer materials from mechanical thrombectomy catheters were similar to the foreign materials found in thrombus specimens. The inner polytetrafluoroethylene liner and coating layer of catheters resembled type I and type II of the foreign materials, respectively. CONCLUSIONS: Foreign polymer materials are present in approximately half of retrieved thrombi, most commonly polytetrafluoroethylene from catheter liners and less from hydrophilic coatings.


Subject(s)
Foreign Bodies , Stroke , Thrombectomy , Thrombosis , Biocompatible Materials , Foreign Bodies/pathology , Humans , Iatrogenic Disease , Polymers , Retrospective Studies , Stroke/surgery , Thrombectomy/instrumentation , Thrombosis/pathology
8.
Exp Mech ; 61(1): 263-283, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33814553

ABSTRACT

BACKGROUND: Rupture of brain aneurysms is associated with high fatality and morbidity rates. Through remodeling of the collagen matrix, many aneurysms can remain unruptured for decades, despite an enlarging and evolving geometry. OBJECTIVE: Our objective was to explore this adaptive remodeling for the first time in an elastase induced aneurysm model in rabbits. METHODS: Saccular aneurysms were created in 22 New Zealand white rabbits and remodeling was assessed in tissue harvested 2, 4, 8 and 12 weeks after creation. RESULTS: The intramural principal stress ratio doubled after aneurysm creation due to increased longitudinal loads, triggering a remodeling response. A distinct wall layer with multi-directional collagen fibers developed between the media and adventitia as early as 2 weeks, and in all cases by 4 weeks with an average thickness of 50.6 ± 14.3 µm. Collagen fibers in this layer were multi-directional (AI = 0.56 ± 0.15) with low tortuosity (1.08 ± 0.02) compared with adjacent circumferentially aligned medial fibers (AI = 0.78 ± 0.12) and highly tortuous adventitial fibers (1.22 ± 0.03). A second phase of remodeling replaced circumferentially aligned fibers in the inner media with longitudinal fibers. A structurally motivated constitutive model with both remodeling modes was introduced along with methodology for determining material parameters from mechanical testing and multiphoton imaging. CONCLUSIONS: A new mechanism was identified by which aneurysm walls can rapidly adapt to changes in load, ensuring the structural integrity of the aneurysm until a slower process of medial reorganization occurs. The rabbit model can be used to evaluate therapies to increase aneurysm wall stability.

9.
AJNR Am J Neuroradiol ; 42(2): 334-339, 2021 01.
Article in English | MEDLINE | ID: mdl-33303525

ABSTRACT

BACKGROUND AND PURPOSE: While WEB devices have been shown to be safe and effective for aneurysm treatment, WEB-shape modification compression has been associated with incomplete aneurysm occlusion. We explored the relationship between occlusion rates and WEB-shape modification in different WEB device types in an experimental aneurysm model. MATERIALS AND METHODS: Elastase-induced aneurysms were created in rabbits and treated with dual-layer (n = 12), single-layer (n = 12), or single-layer sphere (n = 12) WEB devices. Aneurysms were followed up either at 3 or 12 months. Angiographic occlusion was graded using the WEB Occlusion Scale: grade I, complete; grade II, complete but recess filling; grade III, residual neck; or grade IV, residual aneurysm. WEB-shape modification and histologic features were also analyzed. RESULTS: Grade I or II occlusion was seen in 16 (44%) aneurysms, and grade I, II, or III ("adequate") occlusion was observed in 22 (61.1%) aneurysms at follow-up. WEB-shape modification was observed in 22 (61.1%) aneurysms. WEB-shape modification was higher in single-layer (9/12) and dual-layer (10/12) devices compared with single-layer sphere devices (3/12). Aneurysms with WEB-shape modification had a higher level of thrombus organization in the dome compared with those without WEB-shape modification (68% [15/22] versus 50% [7/14]). WEB-shape modification was not correlated with angiographic or histologic outcomes but was significantly correlated with levels of fibrosis and smooth muscle cells in the aneurysm. CONCLUSIONS: WEB-shape modification is not associated with incomplete aneurysm occlusion of WEB devices in the rabbit model but may be related to connective tissue formation and the healing response to WEB device implantation.


Subject(s)
Blood Vessel Prosthesis , Embolization, Therapeutic/instrumentation , Endovascular Procedures/instrumentation , Intracranial Aneurysm , Animals , Intracranial Aneurysm/chemically induced , Intracranial Aneurysm/therapy , Pancreatic Elastase/toxicity , Rabbits , Treatment Outcome
10.
AJNR Am J Neuroradiol ; 41(9): 1657-1662, 2020 09.
Article in English | MEDLINE | ID: mdl-32816763

ABSTRACT

BACKGROUND AND PURPOSE: Impairment of macrophage polarization from a proinflammatory macrophage type 1 (M1) population to an anti-inflammatory macrophage type 2 (M2) population is a hallmark of poor wound healing. In this study, we aimed to evaluate the distribution of M1 and M2 macrophages and to analyze their association with healing in aneurysms embolized by endovascular coiling. MATERIALS AND METHODS: Elastase-induced aneurysms were created in female rabbits and subsequently embolized with platinum coils. Aneurysm occlusions were evaluated with angiographic imaging at 1 (n = 6), 3 (n = 5), or 6 (n = 6) months. Aneurysm tissues were harvested for histologic analysis, quantification of M1 and M2 macrophages by immunofluorescence, and collagen deposition determined by Masson trichrome staining. Histologic grading of aneurysm healing was also performed. Untreated aneurysms were used as controls (n = 6). RESULTS: The M1 macrophage population was highest at 1 month posttreatment, progressively decreasing at 3 and 6 months. The M2 macrophage population progressively increased at 3 and 6 months posttreatment. The highest collagen deposition was at 6 months posttreatment. We found a moderate-to-weak direct correlation between the percentage of M2 macrophages and collagen deposition, as well as total histologic scores overall, and a strongly positive direct correlation between the percentage of M2 macrophages and total histologic scores at 6 months posttreatment. CONCLUSIONS: Our data support the direct correlation between M2 macrophage polarization and healing in aneurysm tissues. Our results show a positive relationship between M2 macrophage populations and total histologic scores at later stages of healing after endovascular coiling. We conclude that interventions aimed at stimulating M2 macrophage expression locally may improve aneurysm healing after coil embolization.


Subject(s)
Embolization, Therapeutic/methods , Intracranial Aneurysm , Macrophages , Wound Healing/physiology , Animals , Blood Vessel Prosthesis , Embolization, Therapeutic/instrumentation , Female , Intracranial Aneurysm/therapy , Platinum , Rabbits
11.
AJNR Am J Neuroradiol ; 41(6): 1043-1048, 2020 06.
Article in English | MEDLINE | ID: mdl-32467181

ABSTRACT

BACKGROUND: Surveillance imaging of previously unruptured, coiled aneurysms remains routine even though reports of rupture of these aneurysms are extremely rare. PURPOSE: We performed meta-analysis to examine long-term rupture risk over ≥1-year follow-up duration in patients with unruptured intracranial aneurysm who underwent endovascular therapy. DATA SOURCES: Multiple databases were searched for relevant publications between 1995 and 2018. STUDY SELECTION: Studies reporting outcome of long-term rupture risk over ≥1-year follow-up in treated patients with unruptured intracranial aneurysms were included. DATA ANALYSIS: Random effects meta-analysis was used, and results were expressed as long-term rupture rate per 100 patient-year with respective 95% CIs. For ruptured aneurysms during follow-up, data were collected on size and completeness of initial Treatment. DATA SYNTHESIS: Twenty-four studies were identified. Among 4842 patients with a mean follow-up duration of 3.2 years, a total of 12 patients (0.25%) experienced rupture of previous unruptured intracranial aneurysms after endovascular treatment. Nine of these 12 patients harbored aneurysms that were large, incompletely treated, or both. A total of 2 anterior circulation, small, completely coiled aneurysms subsequently ruptured. The long-term rupture rate per 100 patient-year for unruptured intracranial aneurysms treated with endovascular therapy was 0.48 (95% CI, 0.45-0.51). Retreatment was carried out in 236 (4.9%) of these 4842 patients. LIMITATIONS: A limitation of the study is that a lack of systematic nature of follow-up and mean follow-up duration of 3.2 years are not sufficient to make general recommendations about aneurysm followup paradigms. CONCLUSIONS: Given a 5% retreatment rate, postcoil embolization spontaneous rupture of previously unruptured, small- and medium-sized, well-treated aneurysms is exceedingly rare.


Subject(s)
Aneurysm, Ruptured/epidemiology , Embolization, Therapeutic/methods , Endovascular Procedures/methods , Intracranial Aneurysm/therapy , Adult , Aged , Female , Humans , Male , Middle Aged , Rupture, Spontaneous/epidemiology , Treatment Outcome
12.
AJNR Am J Neuroradiol ; 40(9): 1511-1516, 2019 09.
Article in English | MEDLINE | ID: mdl-31395663

ABSTRACT

BACKGROUND AND PURPOSE: Intrasaccular flow diversion offers a promising treatment option for complex bifurcation aneurysms. The purpose of this study was to compare the flow conditions between successfully occluded and incompletely occluded aneurysms treated with intrasaccular devices. MATERIALS AND METHODS: The hemodynamics in 18 completely occluded aneurysms after treatment with intrasaccular devices was compared against 18 that were incompletely occluded at follow-up. Hemodynamic and geometric parameters were obtained from computational fluid dynamics models constructed from 3D angiographies. Models of the intrasaccular devices were created and interactively deployed within the vascular models using posttreatment angiography images for guidance. Hemodynamic and geometric variables were compared using the Mann-Whitney test and univariate logistic regression analysis. RESULTS: Incomplete occlusion was associated with large posttreatment mean aneurysm inflows (P = .02) and small reductions in the mean inflow rate (P = .01) and inflow concentration index (P = .03). Incompletely occluded aneurysms were larger (P = .002) and had wider necks (P = .004) than completely occluded aneurysms and tended to have more complex flow patterns, though this trend was not significant after adjusting for multiple testing. CONCLUSIONS: The outcome of cerebral aneurysm treatment with intrasaccular flow diverters is associated with flow conditions created immediately after device implantation. Flow conditions unfavorable for immediate and complete occlusion seem to be created by improper positioning or orientation of the device. Complete occlusion is more difficult to achieve in larger aneurysms, aneurysms with wider necks, and aneurysms with stronger and more complex flows.


Subject(s)
Intracranial Aneurysm/physiopathology , Intracranial Aneurysm/surgery , Neurosurgical Procedures , Vascular Surgical Procedures , Aged , Blood Vessel Prosthesis , Female , Hemodynamics , Humans , Hydrodynamics , Male , Middle Aged , Neurosurgical Procedures/instrumentation , Neurosurgical Procedures/methods , Stents , Treatment Outcome , Vascular Surgical Procedures/instrumentation , Vascular Surgical Procedures/methods
13.
AJNR Am J Neuroradiol ; 40(6): 1018-1021, 2019 06.
Article in English | MEDLINE | ID: mdl-31023661

ABSTRACT

The poorly understood mechanisms of aneurysm healing contribute substantially to the pressing medical problem of coiled aneurysm recanalization. Using an established saccular aneurysm model, we developed an animal model system in rabbits to study aneurysm and skin wound healing concurrently in the same animal. We found treated aneurysm healing to be similar to skin wound healing both histologically and in biomarker gene and protein expression, but in a delayed fashion.


Subject(s)
Intracranial Aneurysm/pathology , Wound Healing/physiology , Animals , Disease Models, Animal , Rabbits
14.
AJNR Am J Neuroradiol ; 38(3): 611-616, 2017 Mar.
Article in English | MEDLINE | ID: mdl-27979795

ABSTRACT

BACKGROUND AND PURPOSE: Vetebrobasilar dolichoectasia is characterized by arterial elongation, dilation, and tortuosity and leads to high risks of ischemic stroke. Our aim was to investigate the differential susceptibility to elastase-induced vertebrobasilar dolichoectasia induction in 2 different mouse strains. MATERIALS AND METHODS: Elastase (25 mU) was injected into the cisterna magna in C57BL/6J (n = 36) and 129/SvEv (SV129) (n = 36) mice. Control animals were injected with heat-inactivated elastase (n = 12 for each strain). At 3, 7, 14, and 28 days after elastase injection, MICROFIL polymer perfusion was performed. The arterial tortuosity index and the percentage increase in diameter were calculated for the basilar artery. Arterial samples were processed for conventional histologic examination, immunostaining, and matrix metalloproteinase expression. A ≥50% increase in diameter and a tortuosity index of ≥10 for the basilar artery were used to indicate success in achieving vertebrobasilar dolichoectasia. RESULTS: Successful vertebrobasilar dolichoectasia induction was noted in 67% (18 of 27) of the C57BL/6J strain versus 0% (0 of 19) of the SV129 strain (P < .001). Vertebrobasilar dolichoectasia was not observed in sham-operated controls. Both the tortuosity index and diameter increase for the basilar artery were greater in the C57BL/6J strain compared with the SV129 strain (56.3% ± 16.4% versus 21.1% ± 21.6% for diameter, P < .001; 17.4 ± 7.6 versus 10.4 ± 3.8 for tortuosity index, P < .001). Expression of pro-matrix metalloproteinase-2 and pro- and active matrix metalloproteinase-9 was increased in elastase-injected C57BL/6J animals compared with elastase-injected SV129 animals (P = .029, 0.029, and 0.029, respectively). Inflammation scores were significantly higher in C57BL/6J animals versus SV129 animals (P < .001). C57BL/6J subjects demonstrated arterial wall dilation and elongation characterized by internal elastic lamina disruption, muscular layer discontinuity, inflammatory cell infiltration, and high matrix metalloproteinase expression in the media. CONCLUSIONS: C57BL/6J mice demonstrated greater susceptibility to vertebrobasilar dolichoectasia induction than SV129 mice.


Subject(s)
Vertebrobasilar Insufficiency/genetics , Animals , Basilar Artery/pathology , Cisterna Magna , Female , Immunohistochemistry , Inflammation/genetics , Inflammation/pathology , Matrix Metalloproteinases/biosynthesis , Matrix Metalloproteinases/genetics , Mice , Mice, Inbred C57BL , Mice, Inbred Strains , Pancreatic Elastase , Species Specificity , Vertebrobasilar Insufficiency/chemically induced , Vertebrobasilar Insufficiency/pathology
15.
AJNR Am J Neuroradiol ; 37(11): 2087-2091, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27390319

ABSTRACT

BACKGROUND AND PURPOSE: Robust wall apposition for flow-diverter stents may be important for endothelialization. Using a large series of experimental aneurysms treated with the Pipeline Embolization Device, the objectives of this study were to 1) assess interobserver agreement for the evaluation of wall apposition on posttreatment DSA and evaluate its association with aneurysm occlusion, and 2) measure the relationship between wall apposition assessed with histology and aneurysm occlusion rate after treatment. MATERIALS AND METHODS: Saccular aneurysms were created in 41 rabbits and treated with the Pipeline Embolization Device. DSA was performed just after the deployment of the device and at follow-up. Three investigators independently graded wall apposition on posttreatment DSA as good or poor. A histopathologist blinded to the angiographic results graded the wall apposition on histologic samples. We examined the correlation between angiographic occlusion and wall apposition with histology and angiography. RESULTS: Wall apposition evaluated on histology was strongly associated with saccular aneurysm occlusion. Sensitivity and specificity of wall apposition to predict complete occlusion at follow-up were 76.9% and 84.0%, respectively, with an overall accuracy of 81.6%. In this experimental study, DSA was suboptimal to assess flow-diverter apposition, with moderate interobserver agreement and low accuracy. CONCLUSIONS: Good wall apposition is strongly associated with complete occlusion after flow-diverter therapy. In this study, DSA was suboptimal for assessing wall apposition of flow-diverter stents. These findings suggest that improved tools for assessing flow diverter-stent wall apposition are highly relevant.

16.
AJNR Am J Neuroradiol ; 37(9): 1664-8, 2016 Sep.
Article in English | MEDLINE | ID: mdl-27256853

ABSTRACT

BACKGROUND AND PURPOSE: Previous studies have suggested an association between aortic aneurysms and intracranial aneurysms with a higher prevalence of intracranial aneurysms in patients with aortic aneurysms. The aims of the present study were to evaluate the incidence of intracranial aneurysms in a large cohort of patients with aortic aneurysms and to identify potential risk factors for intracranial aneurysms in this population. MATERIALS AND METHODS: We included all patients with aortic aneurysms (either abdominal and/or thoracic) who had available cerebral arterial imaging and were seen at our institution during a 15-year period. We identified patients with intracranial aneurysms. Patient demographics, comorbidities, and aortic aneurysm and intracranial aneurysm sizes and locations were analyzed. Univariate analysis was performed with a χ(2) test for categoric variables and a Student t test or ANOVA for continuous variables. RESULTS: A total of 1081 patients with aortic aneurysms were included. Of them, 440 (40.7%) had abdominal aortic aneurysms, 446 (41.3%) had thoracic aortic aneurysms, and 195 (18.0%) had both abdominal aortic and thoracic aortic aneurysms. The overall prevalence of associated intracranial aneurysms in patients with aortic aneurysms was 11.8% (128/1081), with 12.7% (56/440), 10.8% (48/446), and 12.3% (24/195), respectively, in patients with abdominal aortic aneurysms, thoracic aortic aneurysms, and both thoracic aortic aneurysms and abdominal aortic aneurysms. Female patients had a higher risk of associated intracranial aneurysms (OR = 2.08; 95% CI, 1.49-3.03; P = .0002). There was a slight association between abdominal aortic aneurysm size and the prevalence of intracranial aneurysms (OR = 1.02; 95% CI, 1.01-1.03; P = .045). There was no significant association between the locations of the aortic and intracranial aneurysms (P = .93). CONCLUSIONS: The prevalence of intracranial aneurysms is high in patients with aortic aneurysms. Further studies examining the role and cost-effectiveness of intracranial aneurysm screening in patients are warranted.


Subject(s)
Aortic Aneurysm/complications , Intracranial Aneurysm/epidemiology , Aged , Comorbidity , Female , Humans , Male , Middle Aged , Prevalence , Risk Factors
17.
AJNR Am J Neuroradiol ; 37(6): 1114-21, 2016 Jun.
Article in English | MEDLINE | ID: mdl-26721773

ABSTRACT

BACKGROUND AND PURPOSE: The biologic mechanisms leading to aneurysm healing or rare complications such as delayed aneurysm ruptures after flow-diverter placement remain poorly understood. We used RNA sequencing following implantation of coils or flow diverters in elastase aneurysms in rabbits to identify genes and pathways of potential interest. MATERIALS AND METHODS: Aneurysms were treated with coils (n = 5) or flow diverters (n = 4) or were left untreated for controls (n = 6). Messenger RNA was isolated from the aneurysms at 4 weeks following treatment. RNA samples were processed by using RNA-sequencing technology and were analyzed by using the Ingenuity Pathway Analysis tool. RESULTS: With RNA sequencing for coiled versus untreated aneurysms, 464/9990 genes (4.6%) were differentially expressed (58 down-regulated, 406 up-regulated). When we compared flow-diverter versus untreated aneurysms, 177/10,041 (1.8%) genes were differentially expressed (8 down-regulated, 169 up-regulated). When we compared flow-diverter versus coiled aneurysms, 13/9982 (0.13%) genes were differentially expressed (8 down-regulated, 5 up-regulated). Keratin 8 was overexpressed in flow diverters versus coils. This molecule may potentially play a critical role in delayed ruptures due to plasmin production. We identified overregulation of apelin in flow diverters, supporting the preponderance of endothelialization, whereas we found overexpression of molecules implicated in wound healing (dectin 1 and hedgehog interacting protein) for coiled aneurysms. Furthermore, we identified metallopeptidases 1, 12, and 13 as overexpressed in coiled versus untreated aneurysms. CONCLUSIONS: We observed different physiopathologic responses after endovascular treatment with various devices. Flow diverters promote endothelialization but express molecules that could potentially explain the rare delayed ruptures. Coils promote wound healing and express genes potentially implicated in the recurrence of coiled aneurysms.


Subject(s)
Endovascular Procedures/instrumentation , Gene Expression , Intracranial Aneurysm/surgery , RNA, Messenger/biosynthesis , Animals , Disease Models, Animal , RNA, Messenger/analysis , Rabbits , Wound Healing/physiology
18.
AJNR Am J Neuroradiol ; 37(2): 324-9, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26405081

ABSTRACT

BACKGROUND AND PURPOSE: The WEB Occlusion Score has been proposed to assess angiographic outcomes for intracranial aneurysms treated with the Woven EndoBridge (WEB) device. Using a large series of experimental aneurysms treated with the WEB, we had the following objectives: 1) to compare angiographic outcomes as measured by the WEB Occlusion Scale with histologic results, and 2) to assess interobserver and intraobserver agreement of the WEB Occlusion Scale. MATERIALS AND METHODS: Intracranial aneurysms were created in 80 rabbits and treated with WEB devices. Animals were sacrificed at last follow-up for histologic evaluation. DSA was performed just after the deployment of the device and at follow-up. Four investigators independently and retrospectively graded the DSA twice according to the WEB Occlusion Scale. One histopathologist blinded to the angiographic results graded the occlusion according to a 4-point scale patterned on the WEB Occlusion Scale. Intra- and interobserver agreement were evaluated for DSA. Follow-up angiographic grading and histologic reference were compared to determine the WEB Occlusion Scale accuracy for complete (with or without recess filling) versus incomplete occlusion and adequate (complete occlusion or neck remnant) versus inadequate occlusion. RESULTS: Inter- and intraobserver weighted κ for the angiographic WEB Occlusion Scale were, respectively, 0.76 and 0.76, indicating substantial agreement. The sensitivity and specificity of the WEB Occlusion Scale for complete occlusion at follow-up compared with the histologic reference standard were, respectively, 75% and 83.3%, with an overall accuracy of 80%. Similarly, for adequate occlusion at follow-up, sensitivity was 97.7%, specificity was 64.9%, and overall accuracy was 82.5%. CONCLUSIONS: The WEB Occlusion Scale appears to be consistent, reliable, and accurate compared with a histologic reference standard.


Subject(s)
Embolization, Therapeutic/instrumentation , Intracranial Aneurysm/diagnostic imaging , Animals , Cerebral Angiography/methods , Disease Models, Animal , Endovascular Procedures/instrumentation , Female , Intracranial Aneurysm/therapy , Observer Variation , Rabbits , Retrospective Studies , Sensitivity and Specificity , Treatment Outcome
19.
AJNR Am J Neuroradiol ; 37(3): 497-501, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26494695

ABSTRACT

BACKGROUND AND PURPOSE: Thin film nitinol can be processed to produce a thin microporous sheet with a low percentage of metal coverage (<20%) and high pore attenuation (∼70 pores/mm(2)) for flow diversion. We present in vivo results from the treatment of experimental rabbit aneurysms by using a thin film nitinol-based flow-diversion device. MATERIALS AND METHODS: Nineteen aneurysms in the rabbit elastase aneurysm model were treated with a single thin film nitinol flow diverter. Devices were also placed over 17 lumbar arteries to model perianeurysmal branch arteries of the intracranial circulation. Angiography was performed at 2 weeks (n = 7), 1 month (n = 8), and 3 months (n = 4) immediately before sacrifice. Aneurysm occlusion was graded on a 3-point scale (grade I, complete occlusion; grade II, near-complete occlusion; grade III, incomplete occlusion). Toluidine blue staining was used for histologic evaluation. En face CD31 immunofluorescent staining was performed to quantify neck endothelialization. RESULTS: Markedly reduced intra-aneurysmal flow was observed on angiography immediately after device placement in all aneurysms. Grade I or II occlusion was noted in 4 (57%) aneurysms at 2-week, in 6 (75%) aneurysms at 4-week, and in 3 (75%) aneurysms at 12-week follow-up. All 17 lumbar arteries were patent. CD31 staining showed that 75% ± 16% of the aneurysm neck region was endothelialized. Histopathology demonstrated incorporation of the thin film nitinol flow diverter into the vessel wall and no evidence of excessive neointimal hyperplasia. CONCLUSIONS: In this rabbit model, the thin film nitinol flow diverter achieved high rates of aneurysm occlusion and promoted tissue in-growth and aneurysm neck healing, even early after implantation.


Subject(s)
Alloys , Embolization, Therapeutic/instrumentation , Intracranial Aneurysm/therapy , Animals , Cerebral Angiography , Disease Models, Animal , Embolization, Therapeutic/methods , Intracranial Aneurysm/diagnostic imaging , Pancreatic Elastase/toxicity , Rabbits , Stents
20.
AJNR Am J Neuroradiol ; 36(9): 1710-5, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26228879

ABSTRACT

BACKGROUND AND PURPOSE: Rabbit aneurysm models are used for the testing of embolization devices and elucidating the mechanisms of human intracranial aneurysm growth and healing. We used RNA-sequencing technology to identify genes relevant to induced rabbit aneurysm biology and to identify genes and pathways of potential clinical interest. This process included sequencing microRNAs, which are important regulatory noncoding RNAs. MATERIALS AND METHODS: Elastase-induced saccular aneurysms were created at the origin of the right common carotid artery in 6 rabbits. Messenger RNA and microRNA were isolated from the aneurysm and from the control left common carotid artery at 12 weeks and processed by using RNA-sequencing technology. The results from RNA sequencing were analyzed by using the Ingenuity Pathway Analysis tool. RESULTS: A total of 9396 genes were analyzed by using RNA sequencing, 648 (6.9%) of which were found to be significantly differentially expressed between the aneurysms and control tissues (P < .05; false-discovery rate, <0.01; fold change, >2 or <.5). Of these genes, 614 were mapped successfully, 143 were down-regulated, and 471 were up-regulated in the aneurysms as compared with controls. Using the same criteria for significance, 3 microRNAs were identified as down-regulated and 5 were identified as up-regulated. Pathway analysis associated these genes with inflammatory response, cellular migration, and coagulation, among other functions and pathologies. CONCLUSIONS: RNA-sequencing analysis of rabbit aneurysms revealed differential regulation of some key pathways, including inflammation and antigen presentation. ANKRD1 and TACR1 were identified as genes of interest in the regulation of matrix metalloproteinases.


Subject(s)
Intracranial Aneurysm/genetics , MicroRNAs/analysis , RNA, Messenger/analysis , Transcriptome , Animals , Disease Models, Animal , Intracranial Aneurysm/pathology , Oligonucleotide Array Sequence Analysis , Rabbits
SELECTION OF CITATIONS
SEARCH DETAIL
...