Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters











Language
Publication year range
3.
Pediatr Radiol ; 54(3): 457-467, 2024 03.
Article in English | MEDLINE | ID: mdl-37227466

ABSTRACT

We established a framework for collecting radiation doses for head, chest and abdomen-pelvis computed tomography (CT) in children scanned at multiple imaging sites across Latin America with an aim towards establishing diagnostic reference levels (DRLs) and achievable doses (ADs) in pediatric CT in Latin America. Our study included 12 Latin American sites (in Argentina, Bolivia, Brazil, Chile, Colombia, Ecuador, Honduras and Panama) contributing data on the four most common pediatric CT examinations (non-contrast head, non-contrast chest, post-contrast chest and post-contrast abdomen-pelvis). Sites contributed data on patients' age, sex and weight, scan factors (tube current and potential), volume CT dose index (CTDIvol) and dose length product (DLP). Data were verified, leading to the exclusion of two sites with missing or incorrect data entries. We estimated overall and site-specific 50th (AD) and 75th (diagnostic reference level [DRL]) percentile CTDIvol and DLP for each CT protocol. Non-normal data were compared using the Kruskal-Wallis test. Sites contributed data from 3,934 children (1,834 females) for different CT exams (head CT 1,568/3,934, 40%; non-contrast chest CT 945/3,934, 24%; post-contrast chest CT 581/3,934, 15%; abdomen-pelvis CT 840/3,934, 21%). There were significant statistical differences in 50th and 75th percentile CTDIvol and DLP values across the participating sites (P<0.001). The 50th and 75th percentile doses for most CT protocols were substantially higher than the corresponding doses reported from the United States of America. Our study demonstrates substantial disparities and variations in pediatric CT examinations performed in multiple sites in Latin America. We will use the collected data to improve scan protocols and perform a follow-up CT study to establish DRLs and ADs based on clinical indications.


Subject(s)
Diagnostic Reference Levels , Tomography, X-Ray Computed , Female , Humans , Child , Latin America , Radiation Dosage , Reference Values , Tomography, X-Ray Computed/methods
6.
Radiat Prot Dosimetry ; 197(3-4): 135-145, 2021 Dec 30.
Article in English | MEDLINE | ID: mdl-34875692

ABSTRACT

We assessed variations in chest CT usage, radiation dose and image quality in COVID-19 pneumonia. Our study included all chest CT exams performed in 533 patients from 6 healthcare sites from Brazil. We recorded patients' age, gender and body weight and the information number of CT exams per patient, scan parameters and radiation doses (volume CT dose index-CTDIvol and dose length product-DLP). Six radiologists assessed all chest CT exams for the type of pulmonary findings and classified CT appearance of COVID-19 pneumonia as typical, indeterminate, atypical or negative. In addition, each CT was assessed for diagnostic quality (optimal or suboptimal) and presence of artefacts. Artefacts were frequent (367/841), often related to respiratory motion (344/367 chest CT exams with artefacts) and resulted in suboptimal evaluation in mid-to-lower lungs (176/344) or the entire lung (31/344). There were substantial differences in CT usage, patient weight, CTDIvol and DLP across the participating sites.


Subject(s)
COVID-19 , Brazil , Humans , Radiation Dosage , SARS-CoV-2 , Tomography, X-Ray Computed
7.
Radiat Prot Dosimetry ; 195(2): 92-98, 2021 Sep 08.
Article in English | MEDLINE | ID: mdl-34386818

ABSTRACT

Computed tomography (CT) provides useful information in patients with known or suspected COVID-19 infection. However, there are substantial variations and challenges in scanner technologies and scan practices that have negative effect on the image quality and can increase radiation dose associated with CT. OBJECTIVE: In this article, we present major issues and challenges with use of CT at five Brazilian CT facilities for imaging patients with known or suspected COVID-19 infection and offer specific mitigating strategies. METHODS: Observational, retrospective and prospective study of five CT facilities from different states and regions of Brazil, with approval of research and ethics committees. RESULTS: The most important issues include frequent use of CT, lack of up-to-date and efficient scanner technologies, over-scanning and patient off-centring. Mitigating strategies can include updating scanner technology and improving scan practices.


Subject(s)
COVID-19 , Pandemics , Brazil/epidemiology , Humans , Prospective Studies , Radiation Dosage , Retrospective Studies , SARS-CoV-2
8.
Radiol Bras ; 51(6): 377-384, 2018.
Article in English | MEDLINE | ID: mdl-30559555

ABSTRACT

OBJECTIVE: To determine whether dual-energy computed tomography (DECT) of the chest can be performed at a reduced radiation dose, with an emphasis on images generated with post-processing techniques. MATERIALS AND METHODS: In 21 patients undergoing DECT of the chest in a dual-source scanner, an additional image series was acquired at a reduced radiation dose. Four thoracic radiologists assessed both image series for image quality, normal thoracic structures, as well as pulmonary and mediastinal abnormalities, on virtual monochromatic images at 40 keV and 60 keV. Data were analyzed with Student's t-test, kappa statistics, analysis of variance, and the Wilcoxon signed-rank test. RESULTS: The overall image quality of 60 keV virtual monochromatic images at a reduced radiation dose was considered optimal in all patients, and no abnormalities were missed. Contrast enhancement and lesion detection performance were comparable between reduced-dose images at 40 keV and standard-of-care images at 60 keV. The intraobserver and interobserver agreement were both good. The mean volumetric CT dose index (CTDIvol), size-specific dose estimate (SSDE), dose-length product (DLP), and effective dose (ED) for reduced-dose DECT were 3.0 ± 0.6 mGy, 4.0 ± 0.6 mGy, 107 ± 30 mGy.cm, and 1.5 ± 0.4 mSv, respectively. CONCLUSION: DECT of the chest can be performed at a reduced radiation dose (CTDIvol < 3 mGy) without loss of diagnostic information.

9.
Radiol. bras ; Radiol. bras;51(6): 377-384, Nov.-Dec. 2018. tab, graf
Article in English | LILACS | ID: biblio-976759

ABSTRACT

Abstract Objective: To determine whether dual-energy computed tomography (DECT) of the chest can be performed at a reduced radiation dose, with an emphasis on images generated with post-processing techniques. Materials and Methods: In 21 patients undergoing DECT of the chest in a dual-source scanner, an additional image series was acquired at a reduced radiation dose. Four thoracic radiologists assessed both image series for image quality, normal thoracic structures, as well as pulmonary and mediastinal abnormalities, on virtual monochromatic images at 40 keV and 60 keV. Data were analyzed with Student's t-test, kappa statistics, analysis of variance, and the Wilcoxon signed-rank test. Results: The overall image quality of 60 keV virtual monochromatic images at a reduced radiation dose was considered optimal in all patients, and no abnormalities were missed. Contrast enhancement and lesion detection performance were comparable between reduced-dose images at 40 keV and standard-of-care images at 60 keV. The intraobserver and interobserver agreement were both good. The mean volumetric CT dose index (CTDIvol), size-specific dose estimate (SSDE), dose-length product (DLP), and effective dose (ED) for reduced-dose DECT were 3.0 ± 0.6 mGy, 4.0 ± 0.6 mGy, 107 ± 30 mGy.cm, and 1.5 ± 0.4 mSv, respectively. Conclusion: DECT of the chest can be performed at a reduced radiation dose (CTDIvol < 3 mGy) without loss of diagnostic information.


Resumo Objetivo: Verificar se a tomografia computadorizada de dupla energia (TCDE) do tórax pode ser realizada com baixas doses de radiação, com ênfase em imagens pós-processadas. Materiais e Métodos: Em 21 pacientes submetidos a DECT do tórax foi adicionada uma série de imagens adquiridas com baixas doses de radiação. Quatro radiologistas com especialidade em tórax avaliaram a qualidade, visualização de estruturas torácicas normais e também anormalidades pulmonares e mediastinais das imagens monocromáticas de baixa energia (40 e 60 keV). Os dados foram analisados utilizando t-test, estatística kappa, análise de variância e teste Wilcoxon. Resultados: A qualidade das imagens monocromáticas de baixa energia (60 keV) com doses reduzidas foi considerada ótima para todos os pacientes e nenhuma anormalidade no tórax foi perdida. O realce pelo contraste e a performance de detecção de lesões foram similares nas imagens com radiação reduzida e com radiação padrão. Boa concordância intra-avaliadores e interavaliadores foi observada. A média dos parâmetros CTDIvol, SSDE, DLP e ED para TCDE de baixa dose foram 3,0 ± 0,6 mGy, 4,0 ± 0,6 mGy, 107 ± 30 mGy.cm e 1,5 ± 0,4 mSv, respectivamente. Conclusão: TCDE do tórax pode ser realizada com baixas doses de radiação (CTDIvol < 3 mGy), sem perder informações diagnósticas.

SELECTION OF CITATIONS
SEARCH DETAIL