1.
Talanta ; 279: 126614, 2024 Jul 26.
Article in English | MEDLINE | ID: mdl-39094532

ABSTRACT

Miniaturization and mass-production of potentiometric sensor systems is paving the way towards distributed environmental sensing, on-body measurements and industrial process monitoring. Inkjet printing is gaining popularity as a highly adaptable and scalable production technique. Presented here is a scalable and low-cost route for flexible solid-contact ammonium ion-selective electrode fabrication by inkjet printing. Utilization of inkjet-printed melamine-intercalated graphene nanosheets as the solid-contact material significantly improved charge transport, while evading the detrimental water-layer formation. External polarization was investigated as a means of improving the inter-electrode reproducibility: the standard deviations of E0 values were reduced after electrode polarization, the linear region of the response was extended to the range 10-1-10-6 M of NH4Cl and LODs reduced to 0.88 ± 0.17 µM. Finally, we have shown that the electrodes are adequate for measurements in a complex real sample: ammonium concentration was determined in landfill leachate water, with less than 4 % deviation from the reference method.

2.
Nanomaterials (Basel) ; 12(23)2022 Nov 29.
Article in English | MEDLINE | ID: mdl-36500875

ABSTRACT

The large-scale manufacturing of flexible electronics is nowadays based on inkjet printing technology using specially formulated conductive inks, but achieving adequate wetting of different surfaces remains a challenge. In this work, the development of a silver nanoparticle-based functional ink for printing on flexible paper and plastic substrates is demonstrated. Amphiphilic silver nanoparticles with narrow particle size distribution and good dispersibility were prepared via a two-step wet chemical synthesis procedure. First, silver nanoparticles capped with poly(acrylic acid) were prepared, followed by an amidation reaction with 3-morpholynopropylamine (MPA) to increase their lipophilicity. Density functional theory (DFT) calculations were performed to study the interactions between the particles and the dispersion medium in detail. The amphiphilic nanoparticles were dispersed in solvents of different polarity and their physicochemical and rheological properties were determined. A stable ink containing 10 wt% amphiphilic silver nanoparticles was formulated and inkjet-printed on different surfaces, followed by intense pulsed light (IPL) sintering. Low sheet resistances of 3.85 Ω sq-1, 0.57 Ω sq-1 and 19.7 Ω sq-1 were obtained for the paper, coated poly(ethylene terephthalate) (PET) and uncoated polyimide (PI) flexible substrates, respectively. Application of the nanoparticle ink for printed electronics was demonstrated via a simple flexible LED circuit.

3.
Nanomaterials (Basel) ; 12(17)2022 Aug 25.
Article in English | MEDLINE | ID: mdl-36079974

ABSTRACT

With the growing number of flexible electronics applications, environmentally benign ways of mass-producing graphene electronics are sought. In this study, we present a scalable mechanochemical route for the exfoliation of graphite in a planetary ball mill with melamine to form melamine-intercalated graphene nanosheets (M-GNS). M-GNS morphology was evaluated, revealing small particles, down to 14 nm in diameter and 0.4 nm thick. The M-GNS were used as a functional material in the formulation of an inkjet-printable conductive ink, based on green solvents: water, ethanol, and ethylene glycol. The ink satisfied restrictions regarding stability and nanoparticle size; in addition, it was successfully inkjet printed on plastic sheets. Thermal and photonic post-print processing were evaluated as a means of reducing the electrical resistance of the printed features. Minimal sheet resistance values (5 kΩ/sq for 10 printed layers and 626 Ω/sq for 20 printed layers) were obtained on polyimide sheets, after thermal annealing for 1 h at 400 °C and a subsequent single intense pulsed light flash. Lastly, a proof-of-concept simple flexible printed circuit consisting of a battery-powered LED was realized. The demonstrated approach presents an environmentally friendly alternative to mass-producing graphene-based printed flexible electronics.

4.
Food Technol Biotechnol ; 59(2): 216-237, 2021 Jun.
Article in English | MEDLINE | ID: mdl-34316283

ABSTRACT

There is a continuing need for tools and devices which can simplify, quicken and reduce the cost of analyses of food safety and quality. Chemical sensors and biosensors are increasingly being developed for this purpose, reaping from the opportunities provided by nanotechnology. Due to the distinct electrical and optical properties of silver nanoparticles (AgNPs), this material plays a vital role in (bio)sensor development. This review is an analysis of chemical sensors and biosensors based on silver nanoparticles with application in food and beverage matrices. It consists of academic research published from 2015 to 2020. The paper is structured to separately explore the designs of two major (bio)sensor classes: electrochemical (including voltammetric and impedimetric sensors) and optical sensors (including colourimetric and luminescent), with special focus on the type of silver nanomaterial and its role in the sensor system. The review indicates that diverse nanosensors have been developed, capable of detecting analytes such as pesticides, mycotoxins, fertilisers, microorganisms, heavy metals, and various additives with exceptional analytical performance. Current trends in the design of such sensors are highlighted and challenges which need to be overcome in the future are discussed.

5.
Talanta ; 193: 51-55, 2019 Feb 01.
Article in English | MEDLINE | ID: mdl-30368297

ABSTRACT

A simple, low-cost paper-based potassium ion-selective optode that exhibits fully reversible sensing properties is presented. A classic optode formulation consisting of valinomycin as the ionophore and a lipophilic pH indicator has been successfully transferred to a paper substrate and characterised in a flow-through cell with reflectometric optical detection. The optode exhibits high repeatability, reversibility, and stability and can detect potassium in the physiologically relevant concentration range from 10-4 to 10-1 M. This new paper-based optode shows high potential for general application in paper microfluidic systems and for integration into wearable systems for perspiration monitoring due to its reversible and repeatable response. In general, we have demonstrated that ionophore-based optical sensors on paper can successfully be used for continuous ion-concentration monitoring.

6.
Talanta ; 143: 178-183, 2015 Oct 01.
Article in English | MEDLINE | ID: mdl-26078146

ABSTRACT

Wireless chemical sensors are used as analytical devices in homeland defence, home-based healthcare, food logistics and more generally for the Sensor Internet of Things (SIoT). Presented here is a battery-powered and highly portable credit-card size potentiostat that is suitable for performing mobile and wearable amperometric electrochemical measurements with seamless wireless data transfer to mobile computing devices. The mobile electrochemical analytical system has been evaluated in the laboratory with a model redox system - the reduction of hexacyanoferrate(III) - and also with commercially available enzymatic blood-glucose test-strips. The potentiostat communicates wirelessly with mobile devices such as tablets or Smartphones by near-field communication (NFC) or with personal computers by radio-frequency identification (RFID), and thus provides a solution to the 'missing link' in connectivity that often exists between low-cost mobile and wearable chemical sensors and ubiquitous mobile computing products. The mobile potentiostat has been evaluated in the laboratory with a set of proof-of-concept experiments, and its analytical performance compared with a commercial laboratory potentiostat (R(2)=0.9999). These first experimental results demonstrate the functionality of the wireless potentiostat and suggest that the device could be suitable for wearable and point-of-sample analytical measurements. We conclude that the wireless potentiostat could contribute significantly to the advancement of mobile chemical sensor research and adoption, in particular for wearable sensors in healthcare and sport physiology, for wound monitoring and in mobile point-of-sample diagnostics as well as more generally as a part of the Sensor Internet of Things.


Subject(s)
Biosensing Techniques/instrumentation , Chemistry Techniques, Analytical/instrumentation , Electrochemistry/instrumentation , Wireless Technology , Electrodes , Equipment Design , Ferricyanides/chemistry , Glucose/analysis , Hydrodynamics , Radio Waves
7.
Talanta ; 118: 375-81, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24274311

ABSTRACT

A novel miniaturised photometer has been developed as an ultra-portable and mobile analytical chemical instrument. The low-cost photometer presents a paradigm shift in mobile chemical sensor instrumentation because it is built around a contactless smart card format. The photometer tag is based on the radio-frequency identification (RFID) smart card system, which provides short-range wireless data and power transfer between the photometer and a proximal reader, and which allows the reader to also energise the photometer by near field electromagnetic induction. RFID is set to become a key enabling technology of the Internet-of-Things (IoT), hence devices such as the photometer described here will enable numerous mobile, wearable and vanguard chemical sensing applications in the emerging connected world. In the work presented here, we demonstrate the characterisation of a low-power RFID wireless sensor tag with an LED/photodiode-based photometric input. The performance of the wireless photometer has been tested through two different model analytical applications. The first is photometry in solution, where colour intensity as a function of dye concentration was measured. The second is an ion-selective optode system in which potassium ion concentrations were determined by using previously well characterised bulk optode membranes. The analytical performance of the wireless photometer smart tag is clearly demonstrated by these optical absorption-based analytical experiments, with excellent data agreement to a reference laboratory instrument.


Subject(s)
Biosensing Techniques/methods , High-Throughput Screening Assays , Miniaturization , Photometry/methods , Potassium/analysis , Radio Frequency Identification Device/methods , Wireless Technology/instrumentation , Photometry/instrumentation