Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 33
Filter
Add more filters











Publication year range
2.
Article in English | MEDLINE | ID: mdl-39369959

ABSTRACT

Radiofrequency (RF) catheter ablation is the primary treatment for cavotricuspid isthmus (CTI)-dependent atrial flutter (AFL), with cryothermal energy as an alternative. While cryoablation offers comparable effectiveness and safety to RF ablation, it poses a risk of coronary artery spasm leading to ST-elevation. This case report presents a 65-year-old man with drug-refractory atrial fibrillation (AF) and AFL undergoing cryothermal CTI ablation guided by intracardiac echocardiography (ICE). During the procedure, two distinct ST-elevation episodes were observed. The first episode coincided with the pull-down of the cryoablation catheter, potentially resulting in coronary compression, as indicated by ICE, and was rapidly resolved by discontinuing the freezing process. The second episode, occurring without active freezing, was attributed to coronary artery spasm and resolved with intracoronary nitroglycerin administration. During the second episode, emergent right coronary angiography confirmed total occlusion in the segment 4 AV adjacent to the region where cryoablation was performed, which fully resolved post-nitroglycerin. This report underscores the dual mechanisms of ST-elevation-coronary artery compression and spasm-during cryothermal CTI ablation, highlighting the critical role of ICE in enhancing procedural safety.

4.
Clin Case Rep ; 12(8): e9257, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39099885

ABSTRACT

The sheath-in-sheath technique, utilizing a 15Fr cryoballoon delivery sheath inserted into a 25 cm 16Fr sheath, effectively navigates tortuous iliac veins during cryoballoon ablation for atrial fibrillation, ensuring safe delivery and maintaining essential device performance without complications.

5.
J Arrhythm ; 40(3): 614-617, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38939779

ABSTRACT

Hemidiaphragm paralysis, a complication of catheter ablation for atrial fibrillation, can severely affect respiratory function and can lead to paradoxical breathing and dyspnea on exertion. A 75-year-old woman with iatrogenic diaphragm paralysis showed improved symptoms, respiratory function, and exercise tolerance after video-assisted thoracoscopic diaphragm plication.

7.
Clin Case Rep ; 12(6): e9039, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38840753

ABSTRACT

The newly-proposed tandem approach, Wire ThRoUgh Snare Twice (Wire TRUST) is effective for grasping a lead with inaccessible ends. This case report shows that Wire TRUST can also enable successful extraction of a left ventricular lead by iteratively grasping and repositioning to the distal portion of the lead.

9.
Indian Pacing Electrophysiol J ; 24(5): 291-294, 2024.
Article in English | MEDLINE | ID: mdl-38942383

ABSTRACT

This paper presents a novel approach to gap mapping in pulmonary vein isolation (PVI) for atrial fibrillation (AF) treatment, utilizing the real-time Ripple (RR) technique. Radiofrequency (RF) catheter ablation, particularly encircling PVI, is a common intervention for AF. Identifying left atrium-pulmonary vein conduction gaps is crucial for achieving PVI with minimal additional ablation if first-pass PVI is unsuccessful. However, identifying conduction gaps can be relatively challenging, often necessitating manual electrocardiogram reannotation due to the limitations of local activation time (LAT) maps. In the case of a 63-year-old patient with drug-resistant symptomatic persistent AF, the RR technique was utilized to identify conduction gaps during RF ablation. The technique involved pausing fast anatomical mapping (FAM), activating Ripple map (RM) feature on the CARTO 3 system and acquiring points with an ultrahigh-resolution mapping catheter. This approach revealed that the actual site of earliest activation differs from the LAT map indication, enabling successful PVI. The RM feature's capability to reflect actual excitation propagation without reliance on map annotations was crucial for precise conduction gap identification, overcoming inter-operator variability and inaccuracies of conventional methods. The RR technique not only facilitated real-time analysis during gap mapping but also significantly reduced the procedure time, minimizing potential complications. This case report highlights the efficacy of the RR technique in real-time gap mapping, demonstrating its value in cases where first-pass PVI is unsuccessful. The integration of this technique into PVI procedures can enhance both the accuracy and efficiency of catheter ablation for AF.

13.
J Cardiol Cases ; 29(2): 63-66, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38362578

ABSTRACT

The VIZIGO sheath (Biosense Webster, Irvine, CA, USA) is used for catheter ablation (CA) of atrial arrhythmia. In this case report, we describe a complication associated with the VIZIGO sheath and present a successful bailout method. An 82-year-old woman with paroxysmal atrial fibrillation (AF) and atrial tachycardia (AT) was referred to our hospital after experiencing palpitations for 6 months. She underwent CA using the VIZIGO sheath and a fixed Swartz sheath (St. Jude Inc., St. Paul, MN, USA). Pulmonary vein isolation and left atrial posterior wall isolation were performed to address AF and AT. Following ablation, the Swartz sheath was removed; however, the VIZIGO sheath showed resistance to removal. A wire was inserted into the VIZIGO sheath for removal, but the distal electrode ring detached in the vessel. To retrieve the electrode ring, a Mustang over-the-wire angioplasty balloon was dilated inside the ring and withdrawn with the ring. After venography and confirmation of a hemostatic seal, the ablation procedure was completed. The patient experienced postoperative anemia, which was resolved by erythrocyte transfusion. No further paroxysmal AF or AT occurred during the 1-year follow-up. In conclusion, the VIZIGO sheath's distal electrode ring may become detached during CA, and the detached ring can be successfully retrieved using our original bailout technique. Learning objective: This case report highlights the unique complication of electrode ring detachment associated with the novel visualized steerable sheath (VIZIGO; Biosense Webster, Irvine, CA, USA) during catheter ablation procedures and presents the successful technique as a bailout method for retrieving the dislodged ring. The technique involves dilating a non-compliant over-the-wire angioplasty balloon inside the ring and withdrawing it along with the detached ring.

17.
J Cardiol Cases ; 28(4): 176-179, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37818439

ABSTRACT

An 86-year-old male with progressive palpitations and dyspnea was referred to our hospital for heart failure treatment. Catheter ablation was performed for atrial flutter as we suspected tachycardia-induced cardiomyopathy as the cause of the patient's heart failure. Due to difficulty securing a peripheral venous route, a 6-Fr sheath was inserted via the right common femoral vein prior to administering general anesthesia. While attempting to insert a mapping catheter, the 6-Fr sheath became lodged and subsequently fractured during removal. Percutaneous transvenous retrieval using an 8-Fr sheath was unsuccessful, and a switch to a right internal jugular vein approach with a 16-Fr sheath was necessary for successful retrieval. The following two-step retrieval ("lock and dock") was then performed: 1) lock: a vascular snare was used to catch the remaining wire crossing into the fractured sheath lumen to prevent the risk of sheath migration to the right ventricle or the pulmonary artery, and 2) dock: the same snare was subsequently used to catch the fractured sheath. The planned catheter ablation was then successfully performed, without any complications. Learning objective: Our case presents, "lock and dock," a novel approach for percutaneous transvenous retrieval that involves two steps: a vascular snare is used to catch the wire and subsequently the fractured sheath. This use of a vascular snare and a large-diameter sheath through the right internal jugular vein effectively reduces the possibility of fractured sheath migration.

18.
J Arrhythm ; 39(5): 803-806, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37799797

ABSTRACT

In this study, we report two cases with oversensing due to air accumulation in the subcutaneous implantable cardioverter-defibrillator (S-ICD) device generator header. If trapped air in the header of the device is suspected, the re-connection procedure should be considered or the primary vector must be used, which might prevent oversensing.

SELECTION OF CITATIONS
SEARCH DETAIL