Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Hand (N Y) ; : 15589447241233762, 2024 Mar 04.
Article in English | MEDLINE | ID: mdl-38439630

ABSTRACT

BACKGROUND: We assessed factors associated with change in radiographic teardrop angle following volar locking plate (VLP) fixation of volarly displaced intra-articular distal radius fractures with volar ulnar fragments (VUF) within the ICUC database. The primary outcome was change in radiographic alignment on follow-up imaging, defined as a change in teardrop angle from intra-operative fluoroscopy greater than 5°. METHODS: Patients with distal radius fractures treated with a VLP within the ICUC database, an international collaborative and publicly available dataset, were identified. The primary outcome was volar rim loss of reduction on follow-up imaging, defined as a change in radiographic alignment from intra-operative fluoroscopy, teardrop angle less than 50°, or loss of normal radiocarpal alignment. Secondary outcomes were final range of motion (ROM) of the affected extremity. Radiographic Soong classification was used to grade plate position. Descriptive statistics were used to assess variables' distributions. A Random Forest supervised machine learning algorithm was used to classify variable importance for predicting the primary outcome. Traditional descriptive statistics were used to compare patient, fracture, and treatment characteristics with volar rim loss of reduction. Volar rim loss of reduction and final ROM in degrees and as compared with contralateral unaffected limb were also assessed. RESULTS: Fifty patients with volarly displaced, intra-articular distal radius fractures treated with a VLP were identified. Six patients were observed to have a volar rim loss of reduction, but none required reoperation. Volar ulnar fragment size, Soong grade 0, and postfixation axial plate position in relation to the sigmoid notch were significantly associated (P < .05) with volar rim loss of reduction. All cases of volar rim loss of reduction occurred when VUF was 10.8 mm or less. CONCLUSIONS: The size of the VUF was the most important variable for predicting volar rim loss of reduction followed by postfixation plate position in an axial position to the sigmoid notch and the number of volar fragments in the Random Forest machine learning algorithm. There were no significant differences in ROM between patients with volar ulnar escape and those without.

2.
Hand (N Y) ; : 15589447241233763, 2024 Feb 29.
Article in English | MEDLINE | ID: mdl-38420781

ABSTRACT

BACKGROUND: This research sought to analyze a cohort of patients with extensor pollicis longus (EPL) ruptures after volar locked plating of a distal radius fracture (DRF) to characterize the incidence of ruptures that are unlikely to be related to dorsal screw prominence. METHODS: This is a retrospective, observational, descriptive cohort study of adults with operative fixation of a closed DRF and an EPL rupture between 2002 and 2022. Eighteen patients with operative fixation using a volar plate of a closed DRF had an EPL rupture. The cohort consisted of 66% women with an average age of 57.5 years. Median follow-up was 14.5 months. RESULTS: The incidence of EPL rupture was 0.4% (18/4768). The average time from DRF and DRF fixation to EPL rupture was 3.7 and 3.4 months, respectively. Based on the operative record, in 2 of the 18 patients (11%), the rupture was directly attributable to prominent hardware; however, in 4 of the 18 patients (22%), the rupture was not related to prominent hardware, and the cause was indeterminate in 12 patients (67%). Radiologic analysis of those in the indeterminate group demonstrated that 5 of the 12 patients had screws that had a high probability of being prominent. CONCLUSIONS: The incidence of EPL rupture after volar plating of DRF is between 0% and 1% and usually occurs about 3 months after fixation. Approximately 50% of EPL ruptures are attributable to prominent dorsal screws. Although screw prominence is an important cause of EPL rupture, it is not the sole cause of rupture.

3.
Heliyon ; 10(4): e25796, 2024 Feb 29.
Article in English | MEDLINE | ID: mdl-38375267

ABSTRACT

Purpose: This retrospective study aimed to validate the ACS NSQIP Surgical Risk Calculator (SCR) to predict 30-day postoperative outcomes in patients with one of the following subacute orthopedic trauma diagnoses; multiple rib fractures, pelvic ring/acetabular fracture, or unilateral femoral fracture. Methods: Data of patients with these diagnoses treated between January 1, 2015 and September 19, 2020 were extracted from the patients' medical files. Diagnostic performance, discrimination, calibration, and accuracy of the ACS NSQIP SRC to predict specific outcomes developing within 30 days after surgery was determined. Results: The total cohort of the three diagnoses consisted of 435 patients. ACS NSQIP SRC underestimated the risk for serious complications, especially in patients with multiple rib fractures (8.3% predicted vs 17.2% observed) or pelvic ring/acetabular fracture (6.1% vs 19.8%). Underestimation was more pronounced for the composite outcome 'any complication'. Sensitivity ranged from 16.7% to 100% and specificity from 41.1% to 97.1%. Specificity exceeded sensitivity for pelvic ring/acetabular and femoral fractures. Discrimination was good for predicting death (femoral fracture), fair for readmission (femoral fracture), serious complication (multiple rib fractures), and any complication (multiple rib fractures), but poor in all other outcomes and diagnoses. Calibration and accuracy were adequate for all three diagnoses (p-value for Hosmer-Lemeshow test >0.05 and Brier scores <0.25). Conclusion: Performance of the ACS NSQIP SRC in the studied cohort was variable for all three diagnoses. Although it underestimated the risk of most outcomes, calibration and accuracy seemed generally adequate. For most outcomes, adequate diagnostic performance and discrimination could not be confirmed.

4.
Hand (N Y) ; : 15589447231152587, 2023 Feb 16.
Article in English | MEDLINE | ID: mdl-36794764

ABSTRACT

BACKGROUND: Unstable fractures of the distal radius fractures (DRFs) may result in malunion, usually consisting of subsequent shortening and angular deviations. Ulnar shortening osteotomy (USO) is assumed to be a simpler procedure than radial correction osteotomy, resulting in fewer complications and comparable outcomes. The aim of this study was to identify the best surgical technique to perform USO to restore distal radioulnar joint congruency after DRF malunion. METHODS: A systematic review of the literature is performed following the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines in February 2022 to identify studies reporting outcomes and surgical technique for isolated USO. The primary outcome was complication rates. Secondary outcomes included functional, radiologic, and patient-rated outcomes. The methodological index for nonrandomized studies criteria were used to assess the quality of evidence. RESULTS: Included were 12 cohorts (185 participants). Due to substantial heterogeneity, a meta-analysis could not be performed. The overall complication rate was 33% (95% confidence interval, 16% to 51%). The most reported complication was implant irritation (22%), often requiring removal of the implant (13%). Only 3% nonunions were mentioned. Functional and patient-rated outcomes improved in most patients after USO. Quality of evidence of the papers was low to very low. Common methodological flaws were related to retrospective research. CONCLUSION: No evident differences in complication rates and functional outcomes between the surgical techniques were observed. Based on this literature, most complications are related to implant irritation. Nonunion and infection rates were rare. Therefore, a surgical technique with a buried implant might be preferred. This hypothesis requires further investigation.

SELECTION OF CITATIONS
SEARCH DETAIL
...