1.
Med Phys ; 51(1): 93-102, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38043090

ABSTRACT

BACKGROUND: Direct conversion x-ray Photon Counting Detectors (PCD) are posed to play a vital role in future medical imaging devices such as Computed Tomography (CT) scanners. PCD are expected to improve current CT technology on several fronts, such as resolution, dose utilization, and spectral performance. However, they are not readily expected to improve the handling of object scatter, one of the major sources of image artifacts in CT technology. PURPOSE: We explore a potential method for obtaining in-situ object scatter estimation using the same PCD array used in the x-ray imaging system, such as in computed tomography. This unexpected benefit of using PCD has the potential to improve the image quality by providing better input into the scatter estimation and correction algorithms used in image reconstruction. METHODS: In CT scanners the primary method for rejecting scatter signal originating from the scanned object relies on placing anti-scatter grids (ASG) close to the detector plane. This remains the case when transitioning to using PCD instead of energy integration detectors in CT. However, the combination of PCD and ASG opens a possibility to use some of the unique properties of PCD, namely, very low noise and coincidence counters to obtain, in addition to the attenuation data, a simultaneous and instantaneous estimate of the scatter signal reaching every detector element. When a small air gap is introduced between the ASG and the detector surface, the scatter radiation with large angular distribution has a greater probability of producing charge sharing events that can be detected by a coincidence counter. In this work we demonstrate the feasibility of such an approach in a tabletop experiment using PCD detector that lacks coincidence counting capability, instead we use the spectral signature of split charge events as proxy to coincidence counting. For this purpose, we first demonstrate the spectral impact of ASG misalignment using the same experimental setup. In addition, we perform a separate tabletop scattering experiment from a narrow column of water that demonstrates another potential use of the low noise capabilities of PCDs. RESULTS: We measured and quantified the high sensitivity of the spectral response to ASG alignment on the PCD detector pixel array, we found that the probability of energy misregistration of 60 keV photons can increase by up to a factor of 3 when the ASG is poorly aligned. We then leveraged these results to obtain an estimate on the expected increase in coincidence counts for a wide range of scatter-to-primary (SPR) ratio and find a good match with expectations from a geometric modeling of the system, where the expected increase in coincidences was of the order of the SPR. Finally, the low noise detector also allowed us to measure the real space scatter signal associated with the coherent molecular form factor of water, revealing the ring-shaped scatter signal with an energy dependent distribution that was well captured by calculation. CONCLUSIONS: The advent of PCD detectors and their imminent use in commercial CT scanners opens new and exciting possibilities for utilizing PCD detectors in unexpected ways. In this proof-of-concept study, we showed how charge sharing, a spectral information degrading effect, can instead be used to obtain in-situ scatter estimation. We also demonstrated the PCD ability to perform extremely sensitive measurements using affordable benchtop setup for investigations normally reserved for synchrotron facilities.


Subject(s)
Image Processing, Computer-Assisted , Tomography, X-Ray Computed , X-Rays , Tomography, X-Ray Computed/methods , Tomography Scanners, X-Ray Computed , Photons , Water , Phantoms, Imaging
2.
Diagn Interv Imaging ; 104(10): 490-499, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37248095

ABSTRACT

PURPOSE: The purpose of this study was to investigate the feasibility of gadolinium-K-edge-angiography (angio-Gd-K-edge) with gadolinium-based contrast agents (GBCAs) as obtained with spectral photon counting CT (SPCCT) in atherosclerotic rabbits. MATERIALS AND METHODS: Seven atherosclerotic rabbits underwent angio-SPCCT acquisitions with two GBCAs, with similar intravenous injection protocol. Conventional and angio-Gd-K-edge images were reconstructed with the same parameters. Regions of interest were traced in different locations of the aorta and its branches. Hounsfield unit values, Gd concentrations, signal-to-noise (SNR) and contrast-to-noise (CNR) were calculated and compared. The maximum diameter and the diameter of the aorta in regard to atherosclerotic plaques were measured by two observers. Images were subjectively evaluated regarding vessels' enhancement, artefacts, border sharpness and overall image quality. RESULTS: In the analyzable six rabbits, Gd-K-edge allowed visualization of target vessels and no other structures. HU values and Gd concentrations were greatest in the largest artery (descending aorta, 5.6 ± 0.8 [SD] mm), and lowest in the smallest (renal arteries, 2.1 ± 0.3 mm). While greater for conventional images, CNR and SNR were satisfactory for both images (all P < 0.001). For one observer there were no statistically significant differences in either maximum or plaque-diameters (P = 0.45 and all P > 0.05 in post-hoc analysis, respectively). For the second observer, there were no significant differences for images reconstructed with the same parameters (all P < 0.05). All subjective criteria scored higher for conventional images compared to K-edge (all P < 0.01), with the highest scores for enhancement (4.3-4.4 vs. 3.1-3.4). CONCLUSION: With SPCCT, angio-Gd-K-edge after injection of GBCAs in atherosclerotic rabbits is feasible and allows for angiography-like visualization of small arteries and for the reliable measurement of their diameters.


Subject(s)
Gadolinium , Tomography, X-Ray Computed , Animals , Rabbits , Tomography, X-Ray Computed/methods , Angiography , Contrast Media , Abdomen
3.
Radiology ; 303(2): 303-313, 2022 05.
Article in English | MEDLINE | ID: mdl-35166583

ABSTRACT

Background Spatial resolution, soft-tissue contrast, and dose-efficient capabilities of photon-counting CT (PCCT) potentially allow a better quality and diagnostic confidence of coronary CT angiography (CCTA) in comparison to conventional CT. Purpose To compare the quality of CCTA scans obtained with a clinical prototype PCCT system and an energy-integrating detector (EID) dual-layer CT (DLCT) system. Materials and Methods In this prospective board-approved study with informed consent, participants with coronary artery disease underwent retrospective electrocardiographically gated CCTA with both systems after injection of 65-75 mL of 400 mg/mL iodinated contrast agent at 5 mL/sec. A prior phantom task-based quality assessment of the detectability index of coronary lesions was performed. Ultra-high-resolution parameters were used for PCCT (1024 matrix, 0.25-mm section thickness) and EID DLCT (512 matrix, 0.67-mm section thickness). Three cardiac radiologists independently performed a blinded analysis using a five-point quality score (1 = insufficient, 5 = excellent) for overall image quality, diagnostic confidence, and diagnostic quality of calcifications, stents, and noncalcified plaques. A logistic regression model, adjusted for radiologists, was used to evaluate the proportion of improvement in scores with the best method. Results Fourteen consecutive participants (12 men; mean age, 61 years ± 17) were enrolled. Scores of overall quality and diagnostic confidence were higher with PCCT images with a median of 5 (interquartile range [IQR], 2) and 5 (IQR, 1) versus 4 (IQR, 1) and 4 (IQR, 3) with EID DLCT images, using a mean tube current of 255 mAs ± 0 versus 349 mAs ± 111 for EID DLCT images (P < .01). Proportions of improvement with PCCT images for quality of calcification, stent, and noncalcified plaque were 100%, 92% (95% CI: 71, 98), and 45% (95% CI: 28, 63), respectively. In the phantom study, detectability indexes were 2.3-fold higher for lumen and 2.9-fold higher for noncalcified plaques with PCCT images. Conclusion Coronary CT angiography with a photon-counting CT system demonstrated in humans an improved image quality and diagnostic confidence compared with an energy-integrating dual-layer CT. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Sandfort and Bluemke in this issue.


Subject(s)
Computed Tomography Angiography , Photons , Computed Tomography Angiography/methods , Female , Humans , Male , Middle Aged , Prospective Studies , Retrospective Studies , Tomography, X-Ray Computed/methods
4.
Invest Radiol ; 57(4): 212-221, 2022 04 01.
Article in English | MEDLINE | ID: mdl-34711766

ABSTRACT

OBJECTIVES: The aim of this study is to compare the image quality of in vivo coronary stents between an energy integrating detectors dual-layer computed tomography (EID-DLCT) and a clinical prototype of spectral photon counting computed tomography (SPCCT). MATERIALS AND METHODS: In January to June 2021, consecutive patients with coronary stents were prospectively enrolled to undergo a coronary computed tomography (CT) with an EID-DLCT (IQon, Philips) and an SPCCT (Philips). The study was approved by the local ethical committee and patients signed an informed consent. A retrospectively electrocardiogram-gated acquisition was performed with optimized matching parameters on the 2 scanners (EID-DLCT: collimation, 64 × 0.625 mm; kVp, 120, automatic exposure control with target current at 255 mAs; rotation time, 0.27 seconds; SPCCT: collimation, 64 × 0.275 mm; kVp, 120; mAs, 255; rotation time, 0.33 seconds). The injection protocol was the same on both scanners: 65 to 75 mL of Iomeron (Bracco) at 5 mL/s. Images were reconstructed with slice thickness of 0.67 mm, 512 matrix, XCB (Xres cardiac standard) and XCD (Xres cardiac detailed) kernel, iDose 3 for EID-DLCT and 0.25-mm slice thickness, 1024 matrix, Detailed 2 and Sharp kernel, and iDose 6 for SPCCT. Two experienced observers measured the proximal and distal external and internal diameters of the stents to quantify blooming artifacts. Regions of interest were drawn in the lumen of the stent and of the upstream coronary artery. The difference (Δ S-C) between the respective attenuation values was calculated as a quantification of stent-induced artifacts on intrastent image quality. For subjective image quality, 3 experienced observers graded with a 4-point scale the image quality of different parameters: coronary wall before the stent, stent lumen, stent structure, calcifications surrounding the stent, and beam-hardening artifacts. RESULTS: Eight patients (age, 68 years [interquartile range, 8]; all men; body mass index, 26.2 kg/m2 [interquartile range, 4.2]) with 16 stents were scanned. Five stents were not evaluable owing to motion artifacts on the SPCCT. Of the remaining, all were drug eluting stents, of which 6 were platinum-chromium, 3 were cobalt-platinum-iridium, and 1 was stainless steel. For 1 stent, no information could be retrieved. Radiation dose was lower with the SPCCT (fixed CT dose index of 25.7 mGy for SPCCT vs median CT dose index of 35.7 [IQ = 13.6] mGy; P = 0.02). For 1 stent, the internal diameter was not assessable on EID-DLCT. External diameters were smaller and internal diameters were larger with SPCCT (all P < 0.05). Consequently, blooming artifacts were reduced on SPCCT (P < 0.05). Whereas Hounsfield unit values within the coronary arteries on the 2 scanners were similar, the Δ S-C was lower for SPCCT-Sharp as compared with EID-DLCT-XCD and SPCCT-Detailed 2 (P < 0.05). The SPCCT received higher subjective scores than EID-DLCT for stent lumen, stent structure, surrounding calcifications and beam-hardening for both Detailed 2 and Sharp (all P ≤ 0.05). The SPCCT-Sharp was judged better for stent structure and beam-hardening assessment as compared with SPCCT-Detailed 2. CONCLUSION: Spectral photon counting CT demonstrated improved objective and subjective image quality as compared with EID-DLCT for the evaluation of coronary stents even with a reduced radiation dose.


Subject(s)
Computed Tomography Angiography , Platinum , Aged , Computed Tomography Angiography/methods , Coronary Angiography/methods , Humans , Male , Phantoms, Imaging , Photons , Retrospective Studies , Stents , Tomography, X-Ray Computed/methods
5.
Diagnostics (Basel) ; 11(12)2021 Dec 16.
Article in English | MEDLINE | ID: mdl-34943611

ABSTRACT

AIMS: To evaluate spectral photon-counting CT's (SPCCT) objective image quality characteristics in vitro, compared with standard-of-care energy-integrating-detector (EID) CT. METHODS: We scanned a thorax phantom with a coronary artery module at 10 mGy on a prototype SPCCT and a clinical dual-layer EID-CT under various conditions of simulated patient size (small, medium, and large). We used filtered back-projection with a soft-tissue kernel. We assessed noise and contrast-dependent spatial resolution with noise power spectra (NPS) and target transfer functions (TTF), respectively. Detectability indices (d') of simulated non-calcified and lipid-rich atherosclerotic plaques were computed using the non-pre-whitening with eye filter model observer. RESULTS: SPCCT provided lower noise magnitude (9-38% lower NPS amplitude) and higher noise frequency peaks (sharper noise texture). Furthermore, SPCCT provided consistently higher spatial resolution (30-33% better TTF10). In the detectability analysis, SPCCT outperformed EID-CT in all investigated conditions, providing superior d'. SPCCT reached almost perfect detectability (AUC ≈ 95%) for simulated 0.5-mm-thick non-calcified plaques (for large-sized patients), whereas EID-CT had lower d' (AUC ≈ 75%). For lipid-rich atherosclerotic plaques, SPCCT achieved 85% AUC vs. 77.5% with EID-CT. CONCLUSIONS: SPCCT outperformed EID-CT in detecting simulated coronary atherosclerosis and might enhance diagnostic accuracy by providing lower noise magnitude, markedly improved spatial resolution, and superior lipid core detectability.

6.
Diagn Interv Imaging ; 102(5): 305-312, 2021 May.
Article in English | MEDLINE | ID: mdl-33610503

ABSTRACT

PURPOSE: The purpose of this study was to characterize the technical capabilities and feasibility of a large field-of-view clinical spectral photon-counting computed tomography (SPCCT) prototype for high-resolution (HR) lung imaging. MATERIALS AND METHODS: Measurement of modulation transfer function (MTF) and acquisition of a line pairs phantom were performed. An anthropomorphic lung nodule phantom was scanned with standard (120kVp, 62mAs), low (120kVp, 11mAs), and ultra-low (80kVp, 3mAs) radiation doses. A human volunteer underwent standard (120kVp, 63mAs) and low (120kVp, 11mAs) dose scans after approval by the ethics committee. HR images were reconstructed with 1024 matrix, 300mm field of view and 0.25mm slice thickness using a filtered-back projection (FBP) and two levels of iterative reconstruction (iDose 5 and 9). The conspicuity and sharpness of various lung structures (distal airways, vessels, fissures and proximal bronchial wall), image noise, and overall image quality were independently analyzed by three radiologists and compared to a previous HR lung CT examination of the same volunteer performed with a conventional CT equipped with energy integrating detectors (120kVp, 10mAs, FBP). RESULTS: Ten percent MTF was measured at 22.3lp/cm with a cut-off at 31lp/cm. Up to 28lp/cm were depicted. While mixed and solid nodules were easily depicted on standard and low-dose phantom images, higher iDose levels and slice thicknesses (1mm) were needed to visualize ground-glass components on ultra-low-dose images. Standard dose SPCCT images of in vivo lung structures were of greater conspicuity and sharpness, with greater overall image quality, and similar image noise (despite a flux reduction of 23%) to conventional CT images. Low-dose SPCCT images were of greater or similar conspicuity and sharpness, similar overall image quality, and lower but acceptable image noise (despite a flux reduction of 89%). CONCLUSIONS: A large field-of-view SPCCT prototype demonstrates HR technical capabilities and high image quality for high resolution lung CT in human.


Subject(s)
Lung , Tomography, X-Ray Computed , Algorithms , Feasibility Studies , Humans , Image Processing, Computer-Assisted , Lung/diagnostic imaging , Phantoms, Imaging , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted