1.
Article in English | MEDLINE | ID: mdl-38967100

ABSTRACT

OBJECTIVES: To assess navigation accuracy for complete-arch implant placement with immediate loading of digitally prefabricated provisional. MATERIALS AND METHODS: Consecutive edentulous and terminal dentition patients requiring at least one complete-arch FDP were treated between December 2020 and January 2022. Accuracy was evaluated by superimposing pre-operative and post-operative cone beam computed tomography (CBCT), recording linear (mm) and angular (degrees) deviations. T-tests were performed to investigate the potential effect of the registration algorithm (fiducial-based vs. fiducial-free), type of references for the fiducial-free algorithm (teeth vs. bone screws), site characteristic (healed vs. post-extractive), implant angulation (axial vs. tilted), type of arch (maxilla vs. mandible) on the accuracy with p-value <0.05. RESULTS: Twenty-five patients, 36 complete-arches, and 161 implants were placed. The overall mean angular deviation was 2.19° (SD 1.26°). The global platform and apex mean deviations were 1.17 mm (SD 0.57 mm), and 1.30 mm (SD 0.62 mm). Meaningful global platform (p = 0.0009) and apical (p = 0.0109) deviations were experienced only between healed and post-extraction sites. None of the analyzed variables significantly influenced angular deviation. Minor single-axis deviations were reported for the type of jaw (y-axis at implant platform and apex), registration algorithm (y-axis platform and z-axis deviations), and type of references for the fiducial-free algorithm. No statistically significant differences were found in relation to implant angulation. CONCLUSIONS: Within the study limitations navigation was reliable for complete-arch implant placement with immediate loading digitally pre-fabricated FDP. AI-driven surface anatomy identification and calibration protocol made fiducial-free registration as accurate as fiducial-based, teeth and bone screws equal as references. Implant site characteristics were the only statistically significant variable with healed sites reporting higher accuracy compared to post-extractive. Live-tracked navigation surgery enhanced operator performance and accuracy regardless of implant angulation and type of jaw. A mean safety room of about 1 mm and 2° should be considered.

2.
J Clin Med ; 12(2)2023 Jan 06.
Article in English | MEDLINE | ID: mdl-36675417

ABSTRACT

This study aimed to examine the clinical and esthetic outcomes of immediately provisionalized self-tapping implants placed in extraction sockets or healed edentulous ridges one year after treatment. Sixty patients in need of a single implant-supported restoration were treated with self-tapping implants (Straumann BLX) and immediate provisionalization. The implant stability quotient (ISQ) and insertion torque were recorded intraoperatively. After one year in function, the implant and prosthesis survival rate, pink esthetic score (PES), white esthetic score (WES), and marginal bone levels (MBL) were assessed. Sixty patients received 60 self-tapping implants. A total of 37 implants were placed in extraction sockets and 23 in edentulous ridges, and then all implants were immediately provisionalized. All implants achieved a high implant stability with a mean insertion torque and ISQ value of 58.1 ± 14.1 Ncm and 73.6 ± 8.1 Ncm, respectively. No significant differences were found between healed vs. post-extractive sockets (p = 0.716 and p = 0.875), or between flap vs. flapless approaches (p = 0.862 and p = 0.228) with regards to the insertion torque and ISQ value. Nonetheless, higher insertion torque values and ISQs were recorded for mandibular implants (maxilla vs. mandible, insertion torque: 55.30 + 11.25 Ncm vs. 62.41 + 17.01 Ncm, p = 0.057; ISQ: 72.05 + 8.27 vs. 76.08 + 7.37, p = 0.058). One implant did not osseointegrate, resulting in an implant survival rate of 98.3%. All implants achieved PES and WES scores higher than 12 at the 1-year follow-up. The clinical use of newly designed self-tapping implants with immediate temporization was safe and predictable. The implants achieved a good primary stability, high implant survival rate, and favorable radiographic and esthetic outcomes, regardless of the immediate or delayed placement protocols.

3.
Materials (Basel) ; 15(4)2022 Feb 16.
Article in English | MEDLINE | ID: mdl-35208002

ABSTRACT

The aim of this study was to systematically review the current scientific literature regarding the accuracy of fully guided flapless implant positioning for complete-arch rehabilitations in edentulous patients and to assess if there was any statistically significant correlation between linear deviation at shoulder point, at apex point and angular deviation. The electronic and manual literature search of clinical studies was carried out using specified indexing terms. A total of 13 studies were eligible for qualitative analysis and 277 edentulous patients were rehabilitated with 1556 implants patients by means of fully guided mucosa-supported template-assisted flapless surgery. Angular deviation was 3.42° (95% CI 2.82-4.03), linear deviation at shoulder point 1.23 mm (95% CI 0.97-1.49) and linear deviation at apex point 1.46 mm (95% CI 1.17-1.74). No statistically significant correlations were found between the linear and angular deviations. A statistically significant correlation was found between the two linear deviations (correlation coefficient 0.91) that can be summarized by the regression equation y = 0.03080 + 0.8254x. Computer-assisted flapless implant placement by means of mucosa-supported templates in complete arch restorations can be considered a reliable and predictable treatment choice despite the potential effects that flapless approach could bring to the overall treatment.