Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 27
1.
Nanomaterials (Basel) ; 14(8)2024 Apr 10.
Article En | MEDLINE | ID: mdl-38668151

In this work, guanidinium (GA+) was doped into methylammonium lead triiodide (MAPbI3) perovskite film to fabricate perovskite solar cells (PSCs). To determine the optimal formulation of the resulting guanidinium-doped MAPbI3 ((GA)x(MA)1-xPbI3) for the perovskite active layer in PSCs, the perovskite films with various GA+ doping concentrations, annealing temperatures, and thicknesses were systematically modulated and studied. The experimental results demonstrated a 400-nm-thick (GA)x(MA)1-xPbI3 film, with 5% GA+ doping and annealed at 90 °C for 20 min, provided optimal surface morphology and crystallinity. The PSCs configured with the optimal (GA)x(MA)1-xPbI3 perovskite active layer exhibited an open-circuit voltage of 0.891 V, a short-circuit current density of 24.21 mA/cm2, a fill factor of 73.1%, and a power conversion efficiency of 15.78%, respectively. Furthermore, the stability of PSCs featuring this optimized (GA)x(MA)1-xPbI3 perovskite active layer was significantly enhanced.

2.
ACS Sens ; 9(1): 118-125, 2024 Jan 26.
Article En | MEDLINE | ID: mdl-38150672

In this work, a vapor cooling condensation system was utilized to deposit various amounts of p-type gold-black nanoparticles (NPs) onto the surface of n-type gallium oxide (Ga2O3) nanorods forming p-n heterojunction-structured sensing membranes of nitrogen dioxide (NO2) gas sensors. The role and the sensing mechanism of the various gold-black NP-decorated Ga2O3 nanorods in NO2 gas sensors were investigated. The coverage and atomic percentage of the sensing membranes were observed using high-resolution transmission electron microscopy (HRTEM) measurements and energy-dispersive spectroscopy (EDS), respectively. For the NO2 gas sensor using the sensing membrane of 60 s-deposited gold-black NP-decorated Ga2O3 nanorods under a NO2 concentration of 10 ppm, the highest responsivity of 5221.1% was obtained. This result was attributed to the spillover effect and the formation of the p-n heterojunction, which increased more ionized-oxygen adsorption sites and promoted the reaction between NO2 gas and Ga2O3 nanorods. Furthermore, the NO2 gas sensor could detect the low NO2 concentration of 100 ppb and achieved a responsivity of 56.9%. The resulting NO2 gas sensor also exhibited excellent selectivity for detecting NO2 gas, with higher responsivity at a NO2 concentration of 10 ppm compared with that of the C2H5OH and NH3 concentrations of 100 ppm.


Nanotubes , Nitrogen Dioxide , Adsorption , Gases , Gold
3.
Materials (Basel) ; 16(14)2023 Jul 18.
Article En | MEDLINE | ID: mdl-37512335

Due to its high carrier mobility and electron transmission, the phenyl-C61-butyric acid methyl ester (PC61BM) is usually used as an electron transport layer (ETL) in perovskite solar cell (PSC) configurations. However, PC61BM films suffer from poor coverage on perovskite active layers because of their low solubility and weak adhesive ability. In this work, to overcome the above-mentioned shortcomings, 30 nm thick PC61BM ETLs with different concentrations were modeled. Using a 30 nm thick PC61BM ETL with a concentration of 50 mg/mL, the obtained performance values of the PSCs were as follows: an open-circuit voltage (Voc) of 0.87 V, a short-circuit current density (Jsc) of 20.44 mA/cm2, a fill factor (FF) of 70.52%, and a power conversion efficiency (PCE) of 12.54%. However, undesired fine cracks present on the PC61BM surface degraded the performance of the resulting PSCs. To further improve performance, multiple different thicknesses of ZnO interface layers were deposited on the PC61BM ETLs to release the fine cracks using a thermal evaporator. In addition to the pavement of fine cracks, the ZnO interface layer could also function as a hole-blocking layer due to its larger highest occupied molecular orbital (HOMO) energy level. Consequently, the PCE was improved to 14.62% by inserting a 20 nm thick ZnO interface layer in the PSCs.

4.
Materials (Basel) ; 16(12)2023 Jun 19.
Article En | MEDLINE | ID: mdl-37374646

Terahertz (THz) plasmonic metamaterial, based on a metal-wire-woven hole array (MWW-HA), is investigated for the distinct power depletion in the transmittance spectrum of 0.1-2 THz, including the reflected waves from metal holes and woven metal wires. Woven metal wires have four orders of power depletion, which perform sharp dips in a transmittance spectrum. However, only the first-order dip at the metal-hole-reflection band dominates specular reflection with a phase retardation of approximately π. The optical path length and metal surface conductivity are modified to study MWW-HA specular reflection. This experimental modification shows that the first order of MWW-HA power depletion is sustainable and sensitively correlated with a bending angle of the woven metal wire. Specularly reflected THz waves are successfully presented in hollow-core pipe wave guidance specified from MWW-HA pipe wall reflectivity.

5.
Nanomaterials (Basel) ; 13(6)2023 Mar 15.
Article En | MEDLINE | ID: mdl-36985958

In this work, Ga2O3 nanorods were converted from GaOOH nanorods grown using the hydrothermal synthesis method as the sensing membranes of NO2 gas sensors. Since a sensing membrane with a high surface-to-volume ratio is a very important issue for gas sensors, the thickness of the seed layer and the concentrations of the hydrothermal precursor gallium nitrate nonahydrate (Ga(NO3)3·9H2O) and hexamethylenetetramine (HMT) were optimized to achieve a high surface-to-volume ratio in the GaOOH nanorods. The results showed that the largest surface-to-volume ratio of the GaOOH nanorods could be obtained using the 50-nm-thick SnO2 seed layer and the Ga(NO3)3·9H2O/HMT concentration of 12 mM/10 mM. In addition, the GaOOH nanorods were converted to Ga2O3 nanorods by thermal annealing in a pure N2 ambient atmosphere for 2 h at various temperatures of 300 °C, 400 °C, and 500 °C, respectively. Compared with the Ga2O3 nanorod sensing membranes annealed at 300 °C and 500 °C, the NO2 gas sensors using the 400 °C-annealed Ga2O3 nanorod sensing membrane exhibited optimal responsivity of 1184.6%, a response time of 63.6 s, and a recovery time of 135.7 s at a NO2 concentration of 10 ppm. The low NO2 concentration of 100 ppb could be detected by the Ga2O3 nanorod-structured NO2 gas sensors and the achieved responsivity was 34.2%.

6.
Front Oncol ; 12: 1027036, 2022.
Article En | MEDLINE | ID: mdl-36387180

Background: Preoperative two-dimensional manual measurement of pulmonary artery diameter in a single-cut axial view computed tomography (CT) image is a commonly used non-invasive prediction method for pulmonary hypertension. However, the accuracy may be unreliable. Thus, this study aimed to evaluate the correlation of short-term surgical outcomes and pulmonary artery/aorta (PA/Ao) diameter ratio measured by automated three-dimensional (3D) segmentation in lung cancer patients who underwent thoracoscopic lobectomy. Materials and methods: We included 383 consecutive lung cancer patients with thin-slice CT images who underwent lobectomy at a single institute between January 1, 2011 and December 31, 2019. Automated 3D segmentation models were used for 3D vascular reconstruction and measurement of the average diameters of Ao and PA. Propensity-score matching incorporating age, Charlson comorbidity index, and lobectomy performed by uniportal VATS was used to compare clinical outcomes in patients with PA/Ao ratio ≥1 and those <1. Results: Our segmentation method measured 29 (7.57%) patients with a PA/Ao ratio ≥1. After propensity-score matching, a higher overall postoperative complication classified by the Clavien-Dindo classification (p = 0.016) were noted in patients with 3D PA/Ao diameter ratio ≥1 than those of <1. By multivariate logistic regression, patients with a 3D PA/Ao ratio ≥ 1 (p = 0.013) and tumor diameter > 3 cm (p = 0.002) both significantly predict the incidence of postoperative complications. Conclusions: Pulmonary artery/aorta diameter ratio ≥ 1 measured by automated 3D segmentation may predict postoperative complications in lung cancer patients who underwent lobectomy.

8.
Diagnostics (Basel) ; 12(4)2022 Apr 12.
Article En | MEDLINE | ID: mdl-35454015

Pulmonary hypertension should be preoperatively evaluated for optimal surgical planning to reduce surgical risk in lung cancer patients. Preoperative measurement of vascular diameter in computed tomography (CT) images is a noninvasive prediction method for pulmonary hypertension. However, the current estimation method, 2D manual arterial diameter measurement, may yield inaccurate results owing to low tissue contrast in non-contrast-enhanced CT (NECT). Furthermore, it provides an incomplete evaluation by measuring only the diameter of the arteries rather than the volume. To provide a more complete and accurate estimation, this study proposed a novel two-stage deep learning (DL) model for 3D aortic and pulmonary artery segmentation in NECT. In the first stage, a DL model was constructed to enhance the contrast of NECT; in the second stage, two DL models then applied the enhanced images for aorta and pulmonary artery segmentation. Overall, 179 patients were divided into contrast enhancement model (n = 59), segmentation model (n = 120), and testing (n = 20) groups. The performance of the proposed model was evaluated using Dice similarity coefficient (DSC). The proposed model could achieve 0.97 ± 0.66 and 0.93 ± 0.16 DSC for aortic and pulmonary artery segmentation, respectively. The proposed model may provide 3D diameter information of the arteries before surgery, facilitating the estimation of pulmonary hypertension and supporting preoperative surgical method selection based on the predicted surgical risks.

9.
Macromol Rapid Commun ; 43(8): e2100854, 2022 Apr.
Article En | MEDLINE | ID: mdl-35254691

Photodetectors based on reduced graphene oxide (rGO) have attracted much attention owing to their simple and low-cost fabrication process. However, the aggregation and defects of rGO flakes still limit the performance of rGO photodetectors. Controlling the composition of rGO has become a vital factor for its prospective applications. For example, the interconnection between rGO and polymers for modified morphologies of rGO films leads to an enhanced performance of devices. In this work, a practical approach to engineer surface uniformity and enhance the performance of a photodetector by modifying the rGO film with hydrophilic polymers poly(vinyl alcohol) (PVA) is reported. Compared with the rGO photodetector, the on/off ratio for the PVA/rGO photodetector shows 3.5 times improvement, and the detectivity shows 53% enhancement even when the photodetector is operated at a low bias of 0.3 V. This study provides an effective route to realize PVA/rGO photodetectors with a low-power operation which shows promising opportunities for the future development of green systems.

10.
Digit Health ; 8: 20552076211072400, 2022.
Article En | MEDLINE | ID: mdl-35096409

OBJECTIVE: Sepsis is the leading cause of in-hospital mortality in the United States (US). Quality improvement initiatives for improving sepsis care depend on accurate estimates of sepsis mortality. While hospital 30-day risk-standardized mortality rates have been published for patients hospitalized with acute myocardial infarction, heart failure, and pneumonia, risk-standardized mortality rates for sepsis have not been well characterized. We aimed to construct a sepsis risk-standardized mortality rate map for the United States, to illustrate disparities in sepsis care across the country. METHODS: This cross-sectional study included adults from the US Nationwide Inpatient Sample who were hospitalized with sepsis between 1 January 2010 and 30 December 2011. Hospital-level risk-standardized mortality rates were calculated using hierarchical logistic modelling, and were risk-adjusted with predicted mortality derived from (1) the Sepsis Risk Prediction Score, a logistic regression model, and (2) gradient-boosted decision trees, a supervised machine learning (ML) algorithm. RESULTS: Among 1,739,033 adults hospitalized with sepsis, 50% were female, and the median age was 71 years (interquartile range: 58-81). The national median risk-standardized mortality rate for sepsis was 18.4% (interquartile range: 17.0, 21.0) by the boosted tree model, which had better discrimination than the Sepsis Risk Prediction Score model (C-statistic 0.87 and 0.78, respectively). The highest risk-standardized mortality rates were found in Wyoming, North Dakota, and Mississippi, while the lowest were found in Arizona, Colorado, and Michigan. CONCLUSIONS: Wide variation exists in sepsis risk-standardized mortality rates across states, representing opportunities for improvement in sepsis care. This represents the first map of state-level variation of risk-standardized mortality rates in sepsis.

11.
Ann Surg Oncol ; 29(2): 853-863, 2022 Feb.
Article En | MEDLINE | ID: mdl-34427821

PURPOSE: Colon cancer is the third most incident and life-threatening cancer in Taiwan. A comprehensive survival prediction system would greatly benefit clinical practice in this area. This study was designed to develop an accurate prognostic model for colon cancer patients by using clinicopathological variables obtained from the Taiwan Cancer Registry database. METHODS: We analyzed 20,218 colon cancer patients from the Taiwan Cancer Registry database, who were diagnosed between 2007 and 2015, were followed up until December 31, 2017, and had undergone curative surgery. We proposed two prognostic models, with different combinations of predictors. The first model used only traditional clinical features. The second model included several colon cancer site-specific factors (circumferential resection margin, perineural invasion, obstruction, and perforation), in addition to the traditional features. Both prediction models were developed by using a Cox proportional hazards model. Furthermore, we investigated whether race is a significant predictor of survival in colon cancer patients by using Model 1 on the Surveillance, Epidemiology, and End Results (SEER) cancer registry dataset. RESULTS: The proposed models displayed a robust prediction performance (all Harrell's c-index >0.8). For both the calibration and validation steps, the differences between the predicted and observed mortality were mostly less than 5%. CONCLUSIONS: The prediction model (Model 1) is an effective predictor of survival regardless of the ethnic background of patients and can potentially help to provide better prediction of colon cancer-specific survival outcomes, thus allowing physicians to improve treatment plans.


Colonic Neoplasms , Colonic Neoplasms/pathology , Humans , Neoplasm Staging , Prognosis , Proportional Hazards Models , Registries , SEER Program , Taiwan/epidemiology
12.
Ann Surg Oncol ; 29(3): 1608-1615, 2022 Mar.
Article En | MEDLINE | ID: mdl-34775547

PURPOSE: Pancreatic cancer is one of the most malignant cancers with poor survival. The latest edition of the American Joint Committee on Cancer (AJCC) staging system classifies the majority of operable pancreatic cancer patients as stage-III, while dramatic heterogeneity is observed among these patients. Therefore, subgrouping is required to accurately predict their prognosis and define a treatment plan. This study conducts a cohort study to provide a more precise classification system for stage-III pancreatic cancer patients by utilizing clinical variables. METHODS: We analyzed survival using log-rank tests, univariate Cox-regression models, and Kaplan-Meier survival curves for stage-III pancreatic ductal adenocarcinoma (PDAC) patients from the Taiwan Cancer Registry (TCR). Patients were further divided into subgroups using classification and regression tree (CART) algorithm. All results were validated using the SEER database. RESULTS: Among stage-III PDAC patients, lymph node and tumor grade showed significant association with survival. Patients with N2 stage had higher mortality risks (hazard ratio [HR] = 2.30, 95% confidence interval [CI] 1.71-3.08, p < 0.0001) than N0 patients. Patients with grade 3 also had higher risk of mortality (HR = 3.80, 95% CI 2.25-6.39, p < 0.0001) than grade 1 patients. The CART algorithm stratified stage-III patients into four subgroups with significantly different survival rates. The median survival of the four subgroups was 23.5, 18.4, 14.5, and 9.0 months, respectively (p < 0.0001). Similar results were observed with SEER data. CONCLUSIONS: Lymph node involvement and tumor grade are predictive factors for survival in stage-III PDAC patients. This new precise classification system can be used to guide treatment planning in advanced-stage pancreatic cancer.


Pancreatic Neoplasms , Cohort Studies , Humans , Neoplasm Staging , Pancreatic Neoplasms/pathology , Pancreatic Neoplasms/surgery , Prognosis , Registries , SEER Program , Taiwan/epidemiology
13.
Materials (Basel) ; 14(19)2021 Sep 22.
Article En | MEDLINE | ID: mdl-34639872

Multiple-mesa-fin-channel array patterned by a laser interference photolithography system and gallium oxide (Ga2O3) gate oxide layer deposited by a vapor cooling condensation system were employed in double-channel Al0.83In0.17N/GaN/Al0.18Ga0.82N/GaN heterostructured-metal-oxide-semiconductors (MOSHEMTs). The double-channel was constructed by the polarized Al0.18Ga0.82N/GaN channel 1 and band discontinued lattice-matched Al0.83In0.17N/GaN channel 2. Because of the superior gate control capability, the generally induced double-hump transconductance characteristics of double-channel MOSHEMTs were not obtained in the devices. The superior gate control capability was contributed by the side-wall electrical field modulation in the fin-channel. Owing to the high-insulating Ga2O3 gate oxide layer and the high-quality interface between the Ga2O3 and GaN layers, low noise power density of 8.7 × 10-14 Hz-1 and low Hooge's coefficient of 6.25 × 10-6 of flicker noise were obtained. Furthermore, the devices had a unit gain cutoff frequency of 6.5 GHz and a maximal oscillation frequency of 12.6 GHz.

14.
Front Surg ; 8: 747249, 2021.
Article En | MEDLINE | ID: mdl-34676241

Background: As the overall survival of patients with cancer continues to improve, the incidence of second primary malignancies seems to be increasing. Previous studies have shown controversial results regarding the survival of patients with primary lung cancer with previous extrapulmonary malignancies. This study aimed to determine the clinical picture and outcomes of this particular subgroup of patients. Materials and Methods: We included 2,408 patients who underwent pulmonary resection for primary lung cancer at our institute between January 1, 2011 and December 30, 2017 in this retrospective study. Medical records were extracted and clinicopathological parameters and postoperative prognoses were compared between patients with lung cancer with and without previous extrapulmonary malignancies. Results: There were 200 (8.3%) patients with previous extrapulmonary malignancies. Breast cancer (30.5%), gastrointestinal cancer (17%), and thyroid cancer (9%) were the most common previous extrapulmonary malignancies. Age, sex, a family history of lung cancer, and preoperative carcinoembryonic antigen levels were significantly different between the two groups. Patients with previous breast or thyroid cancer had significantly better overall survival than those without previous malignancies. Conversely, patients with other previous extrapulmonary malignancies had significantly poorer overall survival (p < 0.001). The interval between the two cancer diagnoses did not significantly correlate with clinical outcome. Conclusion: Although overall survival was lower in patients with previous extrapulmonary malignancies, previous breast or thyroid cancer did not increase mortality. Our findings may help surgeons to predict prognosis in this subgroup of patients with primary lung cancer.

15.
Int J Syst Evol Microbiol ; 71(10)2021 Oct.
Article En | MEDLINE | ID: mdl-34705625

During an investigation of microbes associated with arthropods living in decaying coconut trees, a Pseudomonas isolate, Milli4T, was cultured from the digestive tract of the common Asian millipede, Trigoniulus corallinus. Sequence analysis of 16S rRNA and rpoB genes found that Milli4T was closely related but not identical to Pseudomonas panipatensis Esp-1T, Pseudomonas knackmussi B13T and Pseudomonas humi CCA1T. Whole genome sequencing suggested that this isolate represents a new species, with average nucleotide identity (OrthoANIu) values of around 83.9-87.7% with its closest relatives. Genome-to-genome distance calculations between Milli4T and its closest relatives also suggested they are distinct species. The genomic DNA G+C content of Milli4T was approximately 65.0 mol%. Phenotypic and chemotaxonomic characterization and fatty acid methyl ester analysis was performed on Milli4T and its related type strains. Based on these data, the new species Pseudomonas schmalbachii sp. nov. is proposed, and the type strain is Milli4T (=BCRC 81294T=JCM 34414T=CIP 111980T).


Arthropods , Phylogeny , Pseudomonas/classification , Animals , Arthropods/microbiology , Bacterial Typing Techniques , Base Composition , Cocos , DNA, Bacterial/genetics , Fatty Acids/chemistry , Nucleic Acid Hybridization , Pseudomonas/isolation & purification , RNA, Ribosomal, 16S/genetics , Sequence Analysis, DNA
16.
Materials (Basel) ; 15(1)2021 Dec 22.
Article En | MEDLINE | ID: mdl-35009193

In this work, Al0.83In0.17N/GaN/Al0.18Ga0.82N/GaN epitaxial layers used for the fabrication of double-channel metal-oxide-semiconductor high-electron mobility transistors (MOSHEMTs) were grown on silicon substrates using a metalorganic chemical vapor deposition system (MOCVD). A sheet electron density of 1.11 × 1013 cm-2 and an electron mobility of 1770 cm2/V-s were obtained. Using a vapor cooling condensation system to deposit high insulating 30-nm-thick Ga2O3 film as a gate oxide layer, double-hump transconductance behaviors with associated double-hump maximum extrinsic transconductances (gmmax) of 89.8 and 100.1 mS/mm were obtained in the double-channel planar MOSHEMTs. However, the double-channel devices with multiple-mesa-fin-channel array with a gmmax of 148.9 mS/mm exhibited single-hump transconductance behaviors owing to the better gate control capability. Moreover, the extrinsic unit gain cutoff frequency and maximum oscillation frequency of the devices with planar channel and multiple-mesa-fin-channel array were 5.7 GHz and 10.5 GHz, and 6.5 GHz and 12.6 GHz, respectively. Hooge's coefficients of 7.50 × 10-5 and 6.25 × 10-6 were obtained for the devices with planar channel and multiple-mesa-fin-channel array operating at a frequency of 10 Hz, drain-source voltage of 1 V, and gate-source voltage of 5 V, respectively.

17.
Sensors (Basel) ; 20(21)2020 Oct 29.
Article En | MEDLINE | ID: mdl-33138043

In this work, Ga2O3 films were deposited on sapphire substrates using a plasma-enhanced atomic layer deposition system with trimethylgallium precursor and oxygen (O2) plasma. To improve the quality of Ga2O3 films, they were annealed in an O2 ambient furnace system for 15 min at 700, 800, and 900 °C, respectively. The performance improvement was verified from the measurement results of X-ray diffraction, X-ray photoelectron spectroscopy, and photoluminescence spectroscopy. The optical bandgap energy of the Ga2O3 films decreased with an increase of annealing temperatures. Metal-semiconductor-metal ultraviolet C photodetectors (MSM UVC-PDs) with various Ga2O3 active layers were fabricated and studied in this work. The cut-off wavelength of the MSM UVC-PDs with the Ga2O3 active layers annealed at 800 °C was 250 nm. Compared with the performance of the MSM UVC-PDs with the as-grown Ga2O3 active layers, the MSM UVC-PDs with the 800 °C-annealed Ga2O3 active layers under a bias voltage of 5 V exhibited better performances including photoresponsivity of 22.19 A/W, UV/visible rejection ratio of 5.98 × 104, and detectivity of 8.74 × 1012 cmHz1/2W-1.

18.
Opt Express ; 28(12): 17299-17306, 2020 Jun 08.
Article En | MEDLINE | ID: mdl-32679940

In this study, poly(N-vinylcarbazole) (PVK) polymer was blended with various dimensional CdSe/ZnS core-shell quantum dots to be used as a single emissive layer of white quantum dots light-emitting diodes (WQLEDs). Besides, the nanostructured ITO/ZnO nanorod array was used as electron transport/injection layer to shorten carrier transport distance, accelerate carrier transport velocity, and enhance carrier transport surface area. Consequently, luminance and luminous efficiency were increased by the resulting increase of the carrier injection current density and the hole-electron recombination opportunity. The CIE of (0.329, 0.331) was obtained for the WQLEDs by using the weight ratio of 1.5:1.3:2.2 of the red, green, and blue (RGB) quantum dots. Compared with the WQLEDs without the nanorod array, the WQLEDs with the 1.5-µm-periodic ITO/ZnO nanorod array obtained an increased luminance of 16333 cd/m2 (compared with 7191 cd/m2) and an increased luminous efficiency of 3.13 cd/A (compared with 2.30 cd/A).

19.
Opt Express ; 28(5): 6433-6442, 2020 Mar 02.
Article En | MEDLINE | ID: mdl-32225891

In the study, the yttrium (Y)-doped vanadium oxide (VOx:Y) films used as the sensitive layers of microbolometers were deposited using a radio frequency magnetron co-sputtering system. The temperature coefficient of resistance (TCR) of the VOx:Y films was enhanced from -1.88%/°C to -2.85%/°C in comparison with that of the VOx films. To further improve the performance of microbolometers, the nanomesh antireflection layer was placed on the top surface of the microbolometers to reduce the infrared reflection. The responsivity, thermal time constant, thermal conductivity, absorptance, and detectivity of the VOx:Y microbolometers with nanomesh antireflection layer were 931.89 ± 48 kV/W, 4.48 ms, 6.19×10-8 W/K, 74.41% and 2.20×108 cmHz0.5W-1, respectively.

20.
Sci Rep ; 8(1): 3968, 2018 Mar 05.
Article En | MEDLINE | ID: mdl-29507329

The three dimensional inverters were fabricated using novel complementary structure of stacked bottom n-type aluminum-doped zinc oxide (Al:ZnO) thin-film transistor and top p-type nickel oxide (NiO) thin-film transistor. When the inverter operated at the direct voltage (VDD) of 10 V and the input voltage from 0 V to 10 V, the obtained high performances included the output swing of 9.9 V, the high noise margin of 2.7 V, and the low noise margin of 2.2 V. Furthermore, the high performances of unskenwed inverter were demonstrated by using the novel complementary structure of the stacked n-type Al:ZnO thin-film transistor and p-type nickel oxide (NiO) thin-film transistor.

...