Int. braz. j. urol ; 50(4): 470-479, July-Aug. 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1569214

ABSTRACT

ABSTRACT Purpose The clinical outcomes of kidney transplantation from deceased donors have seen significant improvements with the use of machine perfusion (MP), now a standard practice in transplant centers. However, the use of perfusate biomarkers for assessing organ quality remains a subject of debate. Despite this, some centers incorporate them into their decision-making process for donor kidney acceptance. Recent studies have indicated that lactate dehydrogenase (LDH), glutathione S-transferase, interleukin-18, and neutrophil gelatinase-associated lipocalin (NGAL) could predict post-transplant outcomes. Materials and Methods Between August 2016 and June 2017, 31 deceased-donor after brain death were included and stroke was the main cause of death. Pediatric patients, hypersensitized recipients were excluded. 43 kidneys were subjected to machine perfusion. Perfusate samples were collected just before the transplantation and stored at -80ºC. Kidney transplant recipients have an average age of 52 years, 34,9% female, with a BMI 24,6±3,7. We employed receiver operating characteristic analysis to investigate associations between these perfusate biomarkers and two key clinical outcomes: delayed graft function and primary non-function. Results The incidence of delayed graft function was 23.3% and primary non-function was 14%. A strong association was found between NGAL concentration and DGF (AUC=0.766, 95% CI, P=0.012), and between LDH concentration and PNF (AUC=0.84, 95% CI, P=0.027). Other perfusate biomarkers did not show significant correlations with these clinical outcomes. Conclusion The concentrations of NGAL and LDH during machine perfusion could assist transplant physicians in improving the allocation of donated organs and making challenging decisions regarding organ discarding. Further, larger-scale studies are required.

2.
Int Braz J Urol ; 50(4): 470-479, 2024.
Article in English | MEDLINE | ID: mdl-38743065

ABSTRACT

PURPOSE: The clinical outcomes of kidney transplantation from deceased donors have seen significant improvements with the use of machine perfusion (MP), now a standard practice in transplant centers. However, the use of perfusate biomarkers for assessing organ quality remains a subject of debate. Despite this, some centers incorporate them into their decision-making process for donor kidney acceptance. Recent studies have indicated that lactate dehydrogenase (LDH), glutathione S-transferase, interleukin-18, and neutrophil gelatinase-associated lipocalin (NGAL) could predict post-transplant outcomes. MATERIALS AND METHODS: Between August 2016 and June 2017, 31 deceased-donor after brain death were included and stroke was the main cause of death. Pediatric patients, hypersensitized recipients were excluded. 43 kidneys were subjected to machine perfusion. Perfusate samples were collected just before the transplantation and stored at -80ºC. Kidney transplant recipients have an average age of 52 years, 34,9% female, with a BMI 24,6±3,7. We employed receiver operating characteristic analysis to investigate associations between these perfusate biomarkers and two key clinical outcomes: delayed graft function and primary non-function. RESULTS: The incidence of delayed graft function was 23.3% and primary non-function was 14%. A strong association was found between NGAL concentration and DGF (AUC=0.766, 95% CI, P=0.012), and between LDH concentration and PNF (AUC=0.84, 95% CI, P=0.027). Other perfusate biomarkers did not show significant correlations with these clinical outcomes. CONCLUSION: The concentrations of NGAL and LDH during machine perfusion could assist transplant physicians in improving the allocation of donated organs and making challenging decisions regarding organ discarding. Further, larger-scale studies are required.


Subject(s)
Biomarkers , Delayed Graft Function , Kidney Transplantation , Lipocalin-2 , Organ Preservation , Perfusion , Humans , Female , Biomarkers/analysis , Male , Middle Aged , Perfusion/methods , Adult , Lipocalin-2/analysis , Organ Preservation/methods , Tissue Donors , ROC Curve , Treatment Outcome , Time Factors , L-Lactate Dehydrogenase/analysis , Reference Values , Predictive Value of Tests
3.
Rev Col Bras Cir ; 46(2): e2079, 2019 May 09.
Article in Portuguese, English | MEDLINE | ID: mdl-31090864

ABSTRACT

With the increasing use of machine perfusion in kidney transplantation, it has been observed that dynamic ischemia correlates with the improvement of organ preservation. In this context, we performed a systematic review that aimed to evaluate the efficacy of the portable machine perfusion (LifePort Kidney Transporter Machine®), used in Brazil, compared to cold storage, regarding the delayed graft function of deceased donors with brain death. Literature search was carried out in LILACS, MEDLINE via PubMed, Scopus, Clarivate Analytics, Cochrane Library, Embase, and SciELO, as well as in Google Scholar manually. The systematic review consisted only of randomized clinical trials. For meta-analysis, relative risk and odds ratio were evaluated. Eighty-six documents were identified and two papers from European and Brazilian groups were selected at the end, with eligibility criteria for meta-analysis. In these, 374 kidneys were assigned to machine perfusion and 374 kidneys were assigned to cold storage. Delayed graft function was observed in 84 and 110 patients, respectively. In meta-analysis, a risk ratio of 0.7568 (p=0.0151) and an odds ratio of 0.6665 (p=0.0225) were obtained, both with a 95% confidence interval. Machine perfusion reduced the incidence of delayed graft function of deceased donors with brain death.


Com a utilização crescente da máquina de perfusão no transplante renal, tem sido constatado que a isquemia dinâmica correlaciona-se à melhora da preservação orgânica. Nesse contexto, realizamos uma revisão sistemática que procurou avaliar a eficácia do uso de máquina de perfusão portátil (LifePort Kidney Transporter Machine®), utilizada no Brasil, comparada ao armazenamento estático, no que tange à função retardada do transplante renal de doadores com morte encefálica. Foi efetuada pesquisa bibliográfica, nas bases LILACS, MEDLINE via PubMed, Scopus, Clarivate Analytics, Cochrane Library, Embase, SciELO, além de busca manual no Google acadêmico. A revisão sistemática, finalizada em abril 2017, foi constituída somente por ensaios clínicos randomizados. Para metanálise, foram avaliadas Razão de Risco e Razão de Chance. Foram identificados 86 documentos e selecionados, ao final, dois artigos com critérios de elegibilidade para metanálise, de grupos europeus e brasileiros. Nestes, 374 rins foram alocados para a máquina de perfusão, e igual número para o armazenamento estático. A função retardada do enxerto foi constatada em 84 e 110 pacientes, respectivamente. Na metanálise, foram obtidas uma Razão de Risco de 0,7568 (p=0,0151) e uma Razão de Chance de 0,6665 (p=0,0225), ambas com intervalo de confiança de 95%. A máquina de perfusão reduziu a incidência de função retardada do enxerto de doadores com morte encefálica.


Subject(s)
Brain Death , Cold Ischemia/methods , Kidney , Organ Preservation/methods , Perfusion/methods , Delayed Graft Function , Humans , Kidney Transplantation/methods , Organ Preservation/instrumentation , Perfusion/instrumentation , Pulsatile Flow , Reproducibility of Results , Risk Factors , Time Factors
4.
Rev. Col. Bras. Cir ; 46(2): e2079, 2019. tab, graf
Article in Portuguese | LILACS | ID: biblio-1003093

ABSTRACT

RESUMO Com a utilização crescente da máquina de perfusão no transplante renal, tem sido constatado que a isquemia dinâmica correlaciona-se à melhora da preservação orgânica. Nesse contexto, realizamos uma revisão sistemática que procurou avaliar a eficácia do uso de máquina de perfusão portátil (LifePort Kidney Transporter Machine®), utilizada no Brasil, comparada ao armazenamento estático, no que tange à função retardada do transplante renal de doadores com morte encefálica. Foi efetuada pesquisa bibliográfica, nas bases LILACS, MEDLINE via PubMed, Scopus, Clarivate Analytics, Cochrane Library, Embase, SciELO, além de busca manual no Google acadêmico. A revisão sistemática, finalizada em abril 2017, foi constituída somente por ensaios clínicos randomizados. Para metanálise, foram avaliadas Razão de Risco e Razão de Chance. Foram identificados 86 documentos e selecionados, ao final, dois artigos com critérios de elegibilidade para metanálise, de grupos europeus e brasileiros. Nestes, 374 rins foram alocados para a máquina de perfusão, e igual número para o armazenamento estático. A função retardada do enxerto foi constatada em 84 e 110 pacientes, respectivamente. Na metanálise, foram obtidas uma Razão de Risco de 0,7568 (p=0,0151) e uma Razão de Chance de 0,6665 (p=0,0225), ambas com intervalo de confiança de 95%. A máquina de perfusão reduziu a incidência de função retardada do enxerto de doadores com morte encefálica.


ABSTRACT With the increasing use of machine perfusion in kidney transplantation, it has been observed that dynamic ischemia correlates with the improvement of organ preservation. In this context, we performed a systematic review that aimed to evaluate the efficacy of the portable machine perfusion (LifePort Kidney Transporter Machine®), used in Brazil, compared to cold storage, regarding the delayed graft function of deceased donors with brain death. Literature search was carried out in LILACS, MEDLINE via PubMed, Scopus, Clarivate Analytics, Cochrane Library, Embase, and SciELO, as well as in Google Scholar manually. The systematic review consisted only of randomized clinical trials. For meta-analysis, relative risk and odds ratio were evaluated. Eighty-six documents were identified and two papers from European and Brazilian groups were selected at the end, with eligibility criteria for meta-analysis. In these, 374 kidneys were assigned to machine perfusion and 374 kidneys were assigned to cold storage. Delayed graft function was observed in 84 and 110 patients, respectively. In meta-analysis, a risk ratio of 0.7568 (p=0.0151) and an odds ratio of 0.6665 (p=0.0225) were obtained, both with a 95% confidence interval. Machine perfusion reduced the incidence of delayed graft function of deceased donors with brain death.


Subject(s)
Humans , Organ Preservation/methods , Perfusion/methods , Brain Death , Cold Ischemia/methods , Kidney , Organ Preservation/instrumentation , Perfusion/instrumentation , Time Factors , Pulsatile Flow , Reproducibility of Results , Risk Factors , Kidney Transplantation/methods , Delayed Graft Function