Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Hazard Mater ; 459: 132201, 2023 Oct 05.
Article in English | MEDLINE | ID: mdl-37544178

ABSTRACT

Dissolved sulfide tends to species transformation and loss upon leaving the matrix, thus the development of a practical on-site determination of sulfide is crucial for environmental monitoring and human health. In this work, a novel paper-based ratiometric fluorescence sensor was developed for the field analysis of sulfide, which system was constructed by the inner filter effect (IFE) of CdS quantum dots (QDs) toward carbon dots (C-dots). Instead of an aqueous phase system, the conversion of sulfide to its hydride would induce the in-situ formation of CdS QDs on the paper, which acted as an energy acceptor to quench the emission of C-dots, leading to a variation of ratiometric fluorescence from blue to yellow with the increasing concentration of sulfide. Moreover, we proposed a smartphone-based fluorescence capture device integrated with a programmed Python program, accomplishing both color recognition and accurate detection of sulfide. Under the optimal condition, this ratiometric fluorescence sensor allowed for the on-site analysis of sulfide with a limit of detection of 0.05 µM. The accuracy of the sensor was validated via the successful field analysis of environmental water samples with satisfactory recoveries. Compared to other fluorescence methods used for sulfide analysis, this developed system retains the advantages of label-free, low-cost, ease of operation, and miniaturization, showing great potential for the measurement of sulfide on-site, as well as environmental monitoring.

2.
J Anal Methods Chem ; 2021: 9571329, 2021.
Article in English | MEDLINE | ID: mdl-34552805

ABSTRACT

Nucleosides can be used as quality evaluation indicators of Tricholoma matsutake. In this work, a new ultra-performance liquid chromatography-tandem mass spectrometry (UPLC/MS) strategy for quantitative analysis of multiple components using a single marker (QAMS) was proposed to determine nine nucleosides (adenosine, cytidine, guanosine, inosine, uridine, 2'-deoxyadenosine, 2'-deoxycytidine, 2'-deoxyguanosine, and 2'-deoxyuridine) in T. matsutake. Guanosine was set as the internal reference substance, whose content in T. matsutake was determined using the conventional external standard method. Relative correction factors (RCFs) between guanosine and eight other nucleosides were measured. The concentrations of the eight components were calculated with the obtained RCFs by QAMS. An ultrasonic extraction method is used for sample preparation. This method was validated to be sensitive, precise, and accurate with the LODs of 0.31-1.9 ng, the overall intraday and interday variations less than 4.08%, and the overall recovery over 89.0%. The correlation coefficients (r 2) of the calibration curves were higher than 0.9918. The values of vector angle analysis were above 0.99845, which indicates no significant differences between the conventional external standard method and the present QAMS method. As far as we know, this is also the first report of UPLC/MS analysis of nucleoside compounds by QAMS, providing an efficient and feasible quality assessment method for other natural products containing nucleosides.

3.
Anal Chem ; 91(4): 2701-2709, 2019 02 19.
Article in English | MEDLINE | ID: mdl-30615435

ABSTRACT

A simple and miniature analytical system was developed to determine Hg and Cd in small amounts of samples by integrating flow injection capillary liquid electrode discharge (CLED) optical emission spectrometry (OES) and microplasma-induced vapor generation (PIVG) atomic fluorescence spectrometry (AFS). With the assistance of the inherent capillary driving force and the force arising from the solution vaporization in the microplasma, the sample solution was automatically transported into the discharge chamber wherein analytes were simultaneously excited to generate their atomic emission lines and converted to their volatile species. Subsequently, the volatile species were further swept into AFS for their further determination. Therefore, the same sample could be successively analyzed by OES and AFS. Owing to the unique independent linear-range and sensitivity of CLED-OES and PIVG-AFS, the developed system not only significantly extended its linear range to 6 orders of magnitude but also remarkably reduced the sample consumption to several microliters. Thus, wide linear-range and ultrasensitive determination of Hg and Cd in limited amounts of samples were accomplished simply by sharing one single capillary liquid electrode discharge source. Under the optimized conditions, limits of detection (LODs) of 10 µg L-1 were obtained for both Hg and Cd when CLED-OES was used as a detector, whereas the LODs for Hg and Cd were improved to 0.03 µg L-1 and 0.04 µg L-1 with AFS detector, respectively. In addition, the extremely wide linear-range of 0.001-100 mg L-1 and 0.001-40 mg L-1 were obtained for Hg and Cd, respectively. The potential application of this method was validated by successfully analyzing three Certified Reference Materials (ZK021-1, GBW(E)090033, and GBW(E)090034) and six human blood samples.


Subject(s)
Cadmium/blood , Flow Injection Analysis/methods , Mercury/blood , Spectrometry, Fluorescence/methods , Spectrophotometry, Atomic/methods , Adult , Equipment Design , Flow Injection Analysis/instrumentation , Humans , Limit of Detection , Spectrometry, Fluorescence/instrumentation , Spectrophotometry, Atomic/instrumentation
4.
Anal Chem ; 89(1): 703-710, 2017 01 03.
Article in English | MEDLINE | ID: mdl-27982564

ABSTRACT

A miniature (2.5 cm length × 2.0 cm width × 1.0 cm height), low power (<10 W), and capillary liquid electrode microplasma optical emission spectrometer was developed for rapid determination of metallic species in aqueous solutions. The sample solution can be automatically introduced into the source without a pump owing to the inherent capillary attraction and the force arising from the solution vaporization induced by microplasma. A droplet array was used as a sampling platform to realize flow injection without using any valve and pump, significantly increasing throughput to 90 samples h-1. Sample volume is controlled through the sampling time and reduced to the nanoliter level. With a sampling time of 10 s (equal to 600 nL), detection limits of 30 µg L-1 (18 pg) and 75 µg L-1 (45 pg) were obtained for Cd and Hg, respectively, comparable to those reported for liquid electrode microplasma optical emission spectrometry. However, sample consumption is reduced more than 100-fold, making the proposed technique more suitable for the analysis of elements such as Cd, Hg, Li, Na, and K when sample volumes may be limited. The utility of this system was demonstrated by the determination of Cd and Hg in blood, real water samples, and Certified Reference Materials (rice powder, GBW07601a, and lobster hepatopancreas, TORT-3).

SELECTION OF CITATIONS
SEARCH DETAIL