1.
Med Phys ; 50(2): 1194-1204, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36135795

ABSTRACT

PURPOSE: The amount of luminescent light detected in a scintillator is reduced with increased proton linear energy transfer (LET) despite receiving the same proton dose, through a phenomenon called quenching. This study evaluated the ability of a solar cell coated with scintillating powder (SC-SP) to measure therapeutic proton LET by measuring the quenching effect of the scintillating powder using a solar cell while simultaneously measuring the dose of the proton beam. METHODS: SC-SP was composed of a flexible thin film solar cell and scintillating powder. The LET and dose of the pristine Bragg peak in the 14 cm range were calculated using a validated Monte Carlo model of a double scattering proton beam nozzle. The SC-SP was evaluated by measuring the proton beam under the same conditions at specific depths using SC-SP and Markus chamber. Finally, the 10 and 20 cm range pristine Bragg peaks and 5 cm spread-out Bragg peak (SOBP) in the 14 cm range were measured using the SC-SP and the Markus chamber. LETs measured using the SC-SP were compared with those calculated using Monte Carlo simulations. RESULTS: The quenching factors of the SC-SP and solar cell alone, which were slopes of linear fit obtained from quenching correction factors according to LET, were 0.027 and 0.070 µm/keV (R2 : 0.974 and 0.975). For pristine Bragg peaks in the 10 and 20 cm ranges, the maximum differences between LETs measured using the SC-SP and calculated using Monte Carlo simulations were 0.5 keV/µm (15.7%) and 1.2 keV/µm (12.0%), respectively. For a 5 cm SOBP proton beam, the LET measured using the SC-SP and calculated using Monte Carlo simulations differed by up to 1.9 keV/µm (18.7%). CONCLUSIONS: Comparisons of LETs for pristine Bragg peaks and SOBP between measured using the SC-SP and calculated using Monte Carlo simulations indicated that the solar cell-based system could simultaneously measure both LET and dose in real-time and is cost-effective.


Subject(s)
Proton Therapy , Protons , Powders , Linear Energy Transfer , Monte Carlo Method
2.
Med Phys ; 45(11): 5277-5282, 2018 Nov.
Article in English | MEDLINE | ID: mdl-30133716

ABSTRACT

PURPOSE: Fabricate an acrylic disk radiation sensor (ADRS) and characterize the photoluminescence signal generated from the optical device as basis for the development and evaluation of a new dosimetry system for pencil beam proton therapy. METHODS: Based on the characteristics of the proposed optical dosimetry sensor, we established the relation between the photoluminescence output and the applied dose using an ionization chamber. Then, we obtained the relative integral depth dose profiles using the photoluminescence signal generated by pencil beam irradiation at energies of 99.9 and 162.1 MeV, and compared the results with the curve measured using a Bragg peak ionization chamber. RESULTS: The relation between the photoluminescence output and applied dose was linear. In addition, the ADRS was dose independent for beam currents up to 6 Gy/min, and the calibration factor for energy was close to 1. Hence, the energy dependence on the optical device can be disregarded. The integral depth dose profiles obtained for the ADRS suitable agreed with the curve measured in the Bragg peak ionization chamber without requiring correction. CONCLUSIONS: These results suggest that the ADRS is suitable for dosimetry measurements in pencil beam scanning, and it will be employed as a low-cost and versatile dosimetry sensor in upcoming developments.


Subject(s)
Proton Therapy/instrumentation , Radiometry/instrumentation , Radiotherapy Dosage
3.
Sensors (Basel) ; 18(1)2018 Jan 15.
Article in English | MEDLINE | ID: mdl-29342941

ABSTRACT

This study describes the development of a beam monitoring system for the verification of entrance dose map in pencil beam scanning (PBS) proton therapy based on fiber optic radiation sensors (FORS) and the validation of this system through a feasibility study. The beam monitoring system consisted of 128 optical fibers optically coupled to photo-multiplier tubes. The performance of the beam monitoring system based on FORS was verified by comparing 2D dose maps of square-shaped fields of various sizes, which were obtained using conventional dosimeters such as MatriXX and EBT3 film, with those measured using FORS. The resulting full-width at half maximum and penumbra were compared for PBS proton beams, with a ≤2% difference between each value, indicating that measurements using the conventional dosimetric tool corresponded to measurements based on FORS. For irregularly-shaped fields, a comparison based on the gamma index between 2D dose maps obtained using MatriXX and EBT3 film and the 2D dose map measured by the FORS showed passing rates of 96.9 ± 1.3% and 96.2 ± 1.9%, respectively, confirming that FORS-based measurements for PBS proton therapy agreed well with those measured using the conventional dosimetric tools. These results demonstrate that the developed beam monitoring system based on FORS is good candidate for monitoring the entrance dose map in PBS proton therapy.

5.
Radiother Oncol ; 117(3): 501-4, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26293200

ABSTRACT

This study describes the development and evaluation of a new dosimetric system for proton therapy using an array of fiber-optic Cerenkov radiation sensors (AFCRS). The AFCRS was superior to a conventional, multi-layer ion chamber (MLIC) system in real-time data acquisition and cost effectiveness.


Subject(s)
Proton Therapy/instrumentation , Radiometry/instrumentation , Fiber Optic Technology , Humans