Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 70
2.
J Geriatr Cardiol ; 20(2): 130-138, 2023 Feb 28.
Article En | MEDLINE | ID: mdl-36910241

BACKGROUND: Recurrence of atrial fibrillation (AF) is common in patients with persistent AF even after multiple ablation procedures. His-Purkinje conduction system pacing (HPCSP) combined with atrioventricular node ablation (AVNA) is effective in managing patients with AF and heart failure. This study aimed to determine whether HPCSP combined with AVNA can improve quality of life and alleviate symptoms in older patients with symptomatic persistent AF refractory to multiple ablation procedures, as well as evaluate the feasibility and safety of this therapy. METHODS: Older patients (≥ 65 years) with symptomatic persistent AF refractory to at least two ablation procedures were treated with combined HPCSP and AVNA. The success rates and complications were recorded. Pacing parameters, European Heart Rhythm Association (EHRA) scores, and Atrial Fibrillation Effect on Quality-of-Life (AFEQT) scores obtained perioperatively were compared with those recorded at the 6-month follow-up examination. RESULTS: Thirty-one patients were enrolled; of those, only thirty patients were eventually treated with AVNA because one patient developed a complete atrioventricular block following the withdrawal of the His bundle pacing lead. The success rates were 100% for HPCSP (22 cases with His bundle pacing, and 9 cases with left bundle branch pacing) and 93.3% (28/30) for AVNA, respectively. By the 6-month follow-up examination, EHRA scores improved significantly (3.00 ± 0.73 vs. 2.44 ± 0.63, P = 0.014) and AFEQT scores increased markedly (49.6 ± 20.6 vs. 70.9 ± 14.0, P = 0.001). No severe complications developed. CONCLUSIONS: When used in older patients with symptomatic persistent AF refractory to multiple ablation procedures, HPCSP combined with AVNA significantly alleviated symptoms and improved quality of life during short-term follow-up. This therapy was proved to be safe and effective in this patient population.

3.
Yi Chuan ; 45(1): 52-66, 2023 Jan 20.
Article En | MEDLINE | ID: mdl-36927638

As an effective supplement to the current forensic DNA typing and one of the research hotpots in forensic science, the in-depth mining and characterization of biological evidence can provide rich and reliable clues for case investigation. In this study, the time-dependent variations of transcriptome were confirmed in in vitro blood samples within 0-168 days and a random forest model was established to realize the classification of blood samples with different TSD (time since deposition). Meanwhile, significant differences were observed in the transcripts of blood samples with different smoking habits and genders within a certain time period. HLA-DRB1, HLA-DQB1 and HLA-DQA2 were identified as markers for smoking habit identification, while the transcripts for RPS4Y1 and EIF1AY from the non-recombining region of the Y chromosome (NRY) were identified as markers for male sex identification. Thus, this study provides a theoretical foundation and experimental strategy for establishing a transcriptome-based method for characterizing blood sample retention time and donor characteristics in the field of forensic investigation.


Transcriptome , Humans , Male , Female , HLA-DRB1 Chains/genetics , Polymerase Chain Reaction , Alleles
4.
J Interv Card Electrophysiol ; 66(3): 539-549, 2023 Apr.
Article En | MEDLINE | ID: mdl-35146599

PURPOSE: Distinguishing between left bundle branch pacing (LBBP) and left ventricular septal pacing (LVSP) is challenging. This study aimed to compare the echocardiographic distance from the pacing lead tip to the left ventricular (LV) septal endocardium between patients who underwent LBBP and those who underwent LVSP successfully. METHODS: Fifty-nine consecutive patients (age 71.9 ± 12.0 years, 35.6% male) with traditional indications for permanent cardiac pacing were included (LBBP group, n = 46; LVSP group, n = 13). Unipolar pacing from the final pacing sites generated narrow QRS complexes with a right bundle branch block pattern in all patients. After the procedure, a physician blinded to the group allocation performed echocardiographic measurements of the distance between the lead tip and the LV septal endocardium. RESULTS: The mean paced QRS duration was comparable between the LBBP group and the LVSP group (105.3 ± 15.6 ms vs. 109.2 ± 9.6 ms, P = 0.287). In the LBBP group, the interval from the left bundle branch potential to QRS onset was 28.7 ± 9.0 ms. During diastole, the mean distance between the lead tip and the LV septal endocardium was 0.6 ± 0.9 mm in the LBBP group and 3.0 ± 1.6 mm in the LVSP group (P < 0.001). During systole, the distance was 1.5 ± 1.4 mm in the LBBP group and 4.3 ± 2.6 mm in the LVSP group (P < 0.001). CONCLUSIONS: The landing zone of the lead tip was closer to the LV septal endocardium in the patients who underwent LBBP. There is a need for real-time intraprocedural monitoring of the distance between the lead tip and the LV septal endocardium when performing LBBP.


Bundle of His , Cardiac Pacing, Artificial , Humans , Male , Middle Aged , Aged , Aged, 80 and over , Female , Cardiac Pacing, Artificial/methods , Endocardium/diagnostic imaging , Electrocardiography/methods , Heart Conduction System
6.
Front Cardiovasc Med ; 9: 949918, 2022.
Article En | MEDLINE | ID: mdl-35990990

Background: High power-ablation index (HP-AI)-guided ablation for atrial fibrillation (AF) targeting high AIs has been implemented in European countries. However, milder AI targets are widely used in Asia. The safety and efficacy of HP-AI-guided ablation compared with those of low-power AI-guided ablation in a milder AI-targeting setting are unknown. The goal of this study was to explore the efficacy and safety of HP-AI-guided ablation in a milder AI-targeting setting. Methods: Patients who underwent pulmonary vein isolation (PVI) for AI-guided atrial fibrillation ablation in our center were enrolled and divided into 2 groups according to the ablation power used. In the HP-AI group, the ablation power was over 45 W, while the low power-AI group was ablated with <35 W power. The targeted AIs were 450-500 in the anterior wall and 350-400 in the posterior wall. The efficacy outcome was expressed as the single-procedure atrial arrhythmia-free survival between 91 days and 1 year. Safety outcomes included severe adverse events (SAEs), including symptomatic pulmonary vein (PV) stenosis, atrioesophagal fistula, cardiac tamponade, stroke, thromboembolism events, myocardial infarction, and major bleeding. Results: A total of 134 patients were enrolled, of whom 74 underwent PVI using HP-AI, while 60 received low power-AI ablation. After a mean follow-up time of 7.4 months, 22 (16.4%) patients showed arrhythmia recurrence: 5 (6.8%) patients in the HP-AI group and 17 (28.3%) patients in the low power-AI group. The HP-AI group showed a significantly higher arrhythmia-free survival than the low power-AI group (p = 0.011). Two patients in the low power-AI group and 1 patient in the HP-AI group developed an SAE (p = NS). Compared with the low power-AI group, the HP-AI group demonstrated a higher PV first-pass isolation rate, shorter ablation time, and fewer patients with anatomical leakages and sites of unreached AI. Conclusion: In a milder AI setting, HP-AI ablation might result in significantly higher arrhythmia-free survival than low power-AI ablation and a similar safety profile.

7.
Am J Cardiol ; 174: 143-150, 2022 07 01.
Article En | MEDLINE | ID: mdl-35487776

Quantification of myocardial perfusion reserve (MPR) using vasodilator stress cardiac magnetic resonance is increasingly used to detect coronary artery disease. However, MPR can also be altered because of changes in microvascular function. We aimed to determine whether MPR can distinguish between ischemic cardiomyopathy (IC) secondary to coronary artery disease and non-IC (NIC) with microvascular dysfunction and no underlying epicardial coronary disease. A total of 60 patients (mean age 65 ± 14 years, 30% women), including 31 with IC and 29 with NIC, were identified from a pre-existing vasodilator stress cardiac magnetic resonance registry. Short-axis cine slices were used to measure left ventricular ejection fraction (LVEF) using the Simpson method of disks. MPR index (MPRi) was determined from first-pass myocardial perfusion images during stress and rest using the upslope ratio, normalized for the arterial input and corrected for rate pressure product. Patients in both groups were divided into subgroups of LVEF ≤35% and LVEF >35%. Differences in MPRi between the subgroups were examined. MPRi was moderately correlated with LVEF in patients with NIC (r = 0.53, p = 0.03), whereas the correlation in patients with IC was lower (r = 0.32, p = 0.22). Average LVEF in NIC and IC was 34% ± 8% and 35% ± 8%, respectively (p = 0.63). MPRi was not significantly different in IC compared with NIC (1.17 [0.88 to 1.61] vs 1.23 [1.07 to 1.66], p = 0.41), including the subgroups of LVEF (IC: 1.20 ± 0.56 vs NIC: 1.15 ± 0.24, p = 0.75 for LVEF ≤35% and IC: 1.35 ± 0.44 vs NIC: 1.58 ± 0.50, p = 0.19 for LVEF >35%). However, MPRi was significantly lower in patients with LVEF ≤35% compared with those with LVEF>35% (1.17 ± 0.40 vs 1.47 ± 0.47, p = 0.01). Similar difference between LVEF groups was noted in the patients with NIC (1.15 ± 0.24 vs 1.58 ± 0.50, p = 0.006) but not in the patients with IC (1.20 ± 0.56 vs 1.35 ± 0.44, p = 0.42). MPRi can be abnormal in the presence of left ventricular dysfunction with nonischemic etiology. This is a potential pitfall to consider when using this approach to detect ischemia because of epicardial coronary disease using myocardial perfusion imaging.


Cardiomyopathies , Coronary Artery Disease , Aged , Cardiomyopathies/complications , Cardiomyopathies/diagnosis , Coronary Circulation , Female , Humans , Ischemia , Magnetic Resonance Imaging, Cine/methods , Male , Middle Aged , Perfusion , Stroke Volume , Vasodilator Agents , Ventricular Function, Left
8.
RSC Adv ; 12(5): 2623-2631, 2022 Jan 18.
Article En | MEDLINE | ID: mdl-35425334

Heterogeneous electro-Fenton is one of the promising technologies to degrade refractory organic phosphonates. In this work, CoNWs@CoAl-LDHs/Fe3O4 and CoNPs@CoAl-LDHs/Fe3O4 were successfully synthesized by a co-precipitation method and applied to degrade 1-hydroxyethane-1,1-diphosphonic acid (HEDP) and glyphosate (PMG) via an electro-Fenton process. The results indicated that the removal rate of HEDP (100 mg L-1) and PMG (100 mg L-1) by CoNWs@CoAl-LDHs/Fe3O4 increased from 62.09% and 95.31% to 82.45% and 100%, respectively. The CoNPs@CoAl-LDHs/Fe3O4 electro-Fenton system could remove 70.03% of HEDP and nearly 100% of PMG within 2 hours at a pH of 3. Moreover, we compared the SEM, EDS, XRD and BET results of CoNWs@CoAl-LDHs/Fe3O4 with those of CoNPs@CoAl-LDHs/Fe3O4. The effects of initial pH, CoNW dosage and reaction time on the degradation of HEDP and PMG were discussed. CoNWs@CoAl-LDHs@Fe3O4 could even remove 71.03% of HEDP at a neutral pH. After four cycles of repeated use at a pH of 3, the removal rate of HEDP by CoNWs@CoAl-LDHs/Fe3O4 was still higher than 70%. Radical quenching experiments revealed that ˙OH is the dominant active species participating in the heterogeneous electro-Fenton process. Finally, we would talk about the mechanism of the CoNWs@CoAl-LDHs/Fe3O4-based electro-Fenton system.

9.
JACC Cardiovasc Imaging ; 15(3): 413-427, 2022 03.
Article En | MEDLINE | ID: mdl-34656471

OBJECTIVES: The aim of this study was to determine whether left ventricular ejection fraction (LVEF) and right ventricular ejection fraction (RVEF) and left ventricular mass (LVM) measurements made using 3 fully automated deep learning (DL) algorithms are accurate and interchangeable and can be used to classify ventricular function and risk-stratify patients as accurately as an expert. BACKGROUND: Artificial intelligence is increasingly used to assess cardiac function and LVM from cardiac magnetic resonance images. METHODS: Two hundred patients were identified from a registry of individuals who underwent vasodilator stress cardiac magnetic resonance. LVEF, LVM, and RVEF were determined using 3 fully automated commercial DL algorithms and by a clinical expert (CLIN) using conventional methodology. Additionally, LVEF values were classified according to clinically important ranges: <35%, 35% to 50%, and ≥50%. Both ejection fraction values and classifications made by the DL ejection fraction approaches were compared against CLIN ejection fraction reference. Receiver-operating characteristic curve analysis was performed to evaluate the ability of CLIN and each of the DL classifications to predict major adverse cardiovascular events. RESULTS: Excellent correlations were seen for each DL-LVEF compared with CLIN-LVEF (r = 0.83-0.93). Good correlations were present between DL-LVM and CLIN-LVM (r = 0.75-0.85). Modest correlations were observed between DL-RVEF and CLIN-RVEF (r = 0.59-0.68). A >10% error between CLIN and DL ejection fraction was present in 5% to 18% of cases for the left ventricle and 23% to 43% for the right ventricle. LVEF classification agreed with CLIN-LVEF classification in 86%, 80%, and 85% cases for the 3 DL-LVEF approaches. There were no differences among the 4 approaches in associations with major adverse cardiovascular events for LVEF, LVM, and RVEF. CONCLUSIONS: This study revealed good agreement between automated and expert-derived LVEF and similarly strong associations with outcomes, compared with an expert. However, the ability of these automated measurements to accurately classify left ventricular function for treatment decision remains limited. DL-LVM showed good agreement with CLIN-LVM. DL-RVEF approaches need further refinements.


Cardiovascular Diseases , Ventricular Function, Right , Artificial Intelligence , Heart Ventricles/diagnostic imaging , Humans , Predictive Value of Tests , Stroke Volume , Ventricular Function, Left
10.
Zhongguo Zhong Yao Za Zhi ; 46(22): 5792-5796, 2021 Nov.
Article Zh | MEDLINE | ID: mdl-34951166

Fusarium is the major pathogen of root rot of Pseudostellaria heterophylla. This study aims to explain the possible distribution of Fusarium species and the contamination of its toxin-chemotypes in tuberous root of P. heterophylla. A total of 89 strains of fungi were isolated from the tuberous root of P. heterophylla. Among them, 29 strains were identified as Fusarium by ITS2 sequence, accounting for 32.5%. They were identified as five species of F. avenaceum, F. tricinctum, F. fujikuroi, F. oxysporum, and F. graminearum based on ß-Tubulin and EF-1α genes. LC-MS/MS detected 18, 1, and 5 strains able to produce ZEN, DON, and T2, which accounted for 62.1%, 3.4%, and 17.2%, respectively. Strain JK3-3 can produce ZEN, DON, and T2, while strains BH1-4-1, BH6-5, and BH16-2 can produce ZEN and T2. PCR detected six key synthase genes of Tri1, Tri7, Tri8, Tri13, PKS14, and PKS13 in strain JK3-3, which synthesized three toxins of ZEN, DON, and T2. Four key synthase genes of Tri8, Tri13, PKS14, and PKS13 were detected in strains BH1-4-1, BH6-5, and BH16-2, which were responsible for the synthesis of ZEN and T2. The results showed that the key genes of toxin biosynthesis were highly correlated with the toxins produced by Fusarium, and the biosynthesis of toxin was strictly controlled by the genetic information of the strain. This study provides a data basis for the targeted prevention and control of exo-genous mycotoxins in P. heterophylla and a possibility for the development of PCR for rapid detection of toxin contamination.


Caryophyllaceae , Fusarium , Mycotoxins , Chromatography, Liquid , Fusarium/genetics , Tandem Mass Spectrometry
11.
J Cardiovasc Electrophysiol ; 32(7): 1842-1848, 2021 07.
Article En | MEDLINE | ID: mdl-34028119

INTRODUCTION: Ablation index (AI)-guided radiofrequency ablation has been increasingly used for the treatment of drug-resistant paroxysmal atrial fibrillation (AF),but the optimal AI targets remain to be determined. We aimed to examine the efficacy and safety of catheter ablation guided by moderate AI values but more strict procedural endpoints in patients with paroxysmal AF. METHODS: We conducted a retrospective review of a consecutive series of patients who received their first AI-guided ablation for paroxysmal AF from 2017 to 2018. The standard procedural protocol recommends AI targets as follows: anterior: 400-450; posterior: 280-330; and roof/inferior wall: 380-430. After circumferential pulmonary vein isolation (PVI), we performed bipolar pacing along the ablation line, adenosine triphosphate (ATP)-provocation, and waited for 30 min to verify PVI. The primary clinical outcome was the rate of freedom from AF recurrence at 12 months. RESULTS: A total of 140 consecutive patients were included. The mean procedure and ablation times were 132.2 ± 30.2 min and 24.2 ± 7.9 min, respectively. The first-pass isolation and final isolation rates were documented in 49.3% and in 100% of the patients, respectively. At 12 months, single-procedure freedom from atrial tachyarrhythmias was observed in 92.1% of patients. No major procedure-related complications were encountered. CONCLUSIONS: Moderate AI-guided catheter ablation is highly effective for the treatment of drug-refractory paroxysmal AF in real-world settings. Over 90% of patients achieved single-procedure arrhythmia-free survival at 1 year. The outcome was obtained without major complications and the procedure involved relatively short procedure and ablation times.


Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Humans , Pulmonary Veins/surgery , Recurrence , Retrospective Studies , Treatment Outcome
12.
Interact Cardiovasc Thorac Surg ; 33(1): 43-50, 2021 06 28.
Article En | MEDLINE | ID: mdl-33890060

OBJECTIVES: Hybrid catheter and surgical ablation has emerged as an effective therapy for patients with persistent atrial fibrillation (AF). The aims of this study were to evaluate the relationship between intraprocedural arrhythmia termination and the long-term outcomes of hybrid ablation in patients with long-standing persistent AF. METHODS: From May 2015 through April 2019, 50 patients with persistent AF with a mean duration of 73.3 ± 62.1 (median 54) months underwent single-step hybrid ablation. Pulmonary vein isolation, left atrial posterior wall isolation and left atrial appendage excision or closure were performed through a left-sided thoracoscopic approach. Subsequently, all patients underwent high-density endocardial mapping and electrogram-based ablation with the end point of AF termination. RESULTS: We achieved intraprocedural AF termination in 84% (42/50) patients; this end point was reached in 16 patients during surgical ablation and in 26 patients during catheter ablation. Seven patients underwent repeat catheter ablation. After a mean follow-up period of 29 ± 13 months, the freedom from atrial tachyarrhythmia of a single procedure without the use of antiarrhythmic drugs was 70% (35/50). In the Cox regression model, intraprocedural termination of AF (hazard ratio 0.205, 95% confidence interval 0.058-0.730; P = 0.014) was the sole predictor of success. CONCLUSIONS: The 2-year outcomes of a one-stop hybrid ablation with an end point of AF termination are promising in patients with long-standing persistent AF.


Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Follow-Up Studies , Humans , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
13.
Environ Sci Pollut Res Int ; 28(9): 11259-11278, 2021 Mar.
Article En | MEDLINE | ID: mdl-33111231

Despite recent advancements in waste management technologies, landfills remain the dominant approach for the final disposal of solid waste (SW) around the world. However, landfills are associated with adverse environmental and health-related impacts. This study is primarily applied to Dar es Salaam, a city in the East African region that has failed to follow appropriate approaches for site selection and that the methods used to select the current sites are manually operated. The study used a geographical information system (GIS) combined with multicriteria decision analysis (MCDA) to objectively determine the optimal landfill sites. A comprehensive list of assessment criteria was examined through a computerized site selection procedure based on GIS to analyze the ground that was surveyed and to remotely obtain data. Analytical hierarchy process (AHP)-one of the best MCDA approaches-was used to assign relative weight and evaluate each criterion. Finally, the study computed site suitability indices (SSIs), which aids in the identification of site suitability levels (SSLs) for the entire region. The final suitability map produced by overlaying the criteria map layers showed that a large part of the study area (60.92%) was completely unsuitable for landfill siting. The remaining areas consisted of land with varying suitability level, which were grouped into four classes: very low (30.92%), low (2.05%), moderate (5.65%), and high (0.46). To this end, only the high suitability class (0.46%) was of acceptable suitability levels (ASLs) (SSI ≥ 2.0). From the numerous identified sites with ASL, only three sites were suggested. Due to concerns regarding the lifespan and environment-related risks associated with these suggested sites, there is a need to further study new environmentally friendly techniques, considering the importance of circular economy agenda of waste to resource/energy for sustainable solid waste management.


Refuse Disposal , Solid Waste , Cities , Decision Support Techniques , Geographic Information Systems , Tanzania , Waste Disposal Facilities
14.
J Int Med Res ; 48(12): 300060520977634, 2020 Dec.
Article En | MEDLINE | ID: mdl-33327831

OBJECTIVE: To investigate the value of a notched unipolar electrogram (N-uniEGM) in confirming the origin of premature ventricular contractions originating from the ventricular outflow tract (VOT-PVC) during mapping and ablation procedures. METHODS: This retrospective study enrolled consecutive patients with symptomatic idiopathic frequent VOT-PVCs that underwent radiofrequency ablation. The characteristics of the uniEGM of the successful ablation targets were analysed. N-uniEGM was defined as the uniEGM presenting a QS morphology with ≥1 steep notches on the downstroke deflection. All patients were followed-up for 3 months post-ablation. RESULTS: The study enrolled 190 patients with a mean ± SD age of 49.0 ± 15.3 years. N-uniEGMs were recorded in 124 of 190 (65.3%) patients. The N-uniEGM distribution area was limited to a mean ± SD of 0.8 ± 0.4 cm2. N-uniEGM showed consistency with the outcomes of activation mapping and pace mapping. Patients with an N-uniEGM had an ablation success rate of 98.4% (122 of 124) and their ablation times were significantly shorter than those without an N-uniEGM (7.6 ± 3.8 s versus 15.8 ± 8.8 s, respectively). The sensitivity and specificity of N-uniEGM in predicting successful ablation of VOT-PVCs were 72.6% and 91.7%, respectively. CONCLUSION: N-uniEGM was a highly specific and moderately sensitive predictor of successful radiofrequency ablation in patients with VOT-PVCs.


Catheter Ablation , Ventricular Premature Complexes , Adult , Humans , Male , Middle Aged , Retrospective Studies , Stroke Volume , Treatment Outcome , Ventricular Function, Left , Ventricular Premature Complexes/surgery
15.
Pacing Clin Electrophysiol ; 43(11): 1358-1365, 2020 11.
Article En | MEDLINE | ID: mdl-33000472

INTRODUCTION: Combined catheter ablation (CA) and left atrial appendage closure (LAAC) have proven to be a feasible and safe strategy in treating patients with nonvalvular atrial fibrillation (AF). However, the interactions between CA and LAAC have not been systematically explored. We analyzed the impact of CA on long-term outcomes of LAAC in patients with AF treated with the hybrid procedure. METHODS: A total of 107 consecutive patients with AF who underwent LAAC were divided into two groups: group A (n = 61) included patients who underwent CA followed by LAAC during the same procedure and group B (n = 46) included patients who underwent LAAC only. All patients underwent systematic transesophageal echocardiography (TEE) follow-up. RESULTS: In group A, CA resulted in severe edema of the left atrial ridge (LAR), which manifested as an increase in LAR thickness from 4.6 ± 0.4 mm before CA to 6.8 ± 0.6 mm (P < .01) after CA. TEE at 45 days showed that the incidence of peri-device leakage was significantly higher in group A than in group B (45.9% vs 4.3%, P < .001). At the 12-month follow-up, the peri-device leakage rate remained higher in group A than in group B (14.8% vs 2.2%, P < .01). Three (4.9%) patients in group A experienced transient ischemia attacks; no events were reported in group B during the 1-year follow-up. CONCLUSION: Edema of LAR with the single-stage procedure that consists of CA followed by LAAC could result in increased peri-device leakage and decreased compression rate over time, which may be also associated with elevated risk profiles when compared with an LAAC-only procedure.


Atrial Appendage/surgery , Atrial Fibrillation/surgery , Cardiac Surgical Procedures/methods , Catheter Ablation/methods , Postoperative Complications/epidemiology , Aged , Combined Modality Therapy , Female , Humans , Male , Risk Factors
16.
J Int Med Res ; 48(8): 300060520947880, 2020 Aug.
Article En | MEDLINE | ID: mdl-32812472

A 70-year-old woman with symptomatic bradycardia caused by persistent atrial fibrillation and atrioventricular block was referred to our institution for pacemaker implantation. After we failed to obtain adequate His bundle capture thresholds (>2.5 V at 1.0 ms) at three pacing sites, left bundle branch pacing was attempted as an alternative technique. The tip of the 3830 lead was screwed towards the left side of the interventricular septum. Contrast medium was injected through the C315 sheath, which was placed close to the right side of the interventricular septum to determine the exact depth of the 3830 lead inside the septum. Unexpectedly, the vessels in the interventricular septum were revealed by the contrast, which showed that the lead had penetrated one of the septal vessels. To the best of our knowledge, this is the first reported case of a patient in whom injection of a contrast agent through a delivery sheath showed damage to the interventricular septal vessels. Findings from this case suggest that injection of contrast medium through a C315 sheath that is placed close to the interventricular septum is a potential method for excluding damage to interventricular septal vessels.


Pacemaker, Artificial , Vascular System Injuries , Ventricular Septum , Aged , Bundle of His , Cardiac Pacing, Artificial , Electrocardiography , Female , Humans , Pacemaker, Artificial/adverse effects , Ventricular Septum/diagnostic imaging
17.
Europace ; 22(8): 1197-1205, 2020 08 01.
Article En | MEDLINE | ID: mdl-32514560

AIMS: Circumferential pulmonary vein isolation can be effective as sole treatment for persistent atrial fibrillation. However, identifying those patients who will respond to this therapy remains a challenge. We investigated the clinical value of the sequential low-dose ibutilide test for identifying patients with persistent atrial fibrillation in whom pulmonary vein isolation is effective as sole therapy. METHODS AND RESULTS: In a prospective cohort of 180 consecutive patients with persistent atrial fibrillation, intravenous low-dose (0.004 mg/kg) ibutilide was administered 3 days before ablation and after the completion of circumferential pulmonary vein isolation. In patients in whom ibutilide did not terminate atrial fibrillation pre-procedurally, but successfully terminated it intraprocedurally, no further atrial substrate modification was performed. Pre-procedural low-dose ibutilide failed to terminate the arrhythmia in all patients with persistent atrial fibrillation, while pulmonary vein isolation ± low-dose ibutilide terminated persistent atrial fibrillation in 55 (30.6%) of them (PsAF group 1). The remaining 125 (69.4%) patients underwent electrogram-based ablation (PsAF Group 2). The control group comprised 379 consecutive patients with paroxysmal atrial fibrillation who underwent pulmonary vein isolation over the same period. At 24 months follow-up, 39 (70.9%) patients in PsAF Group 1 and 276 (72.8%) patients in the control group were free from atrial tachyarrhythmias (P = NS); the arrhythmia-free rates in both groups were higher than that in PsAF group 2 (58.4%, P = 0.005). CONCLUSION: The sequential low-dose ibutilide test is a simple method for identifying patients with persistent atrial fibrillation in whom pulmonary vein isolation alone is an appropriate treatment strategy.


Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/diagnosis , Atrial Fibrillation/drug therapy , Atrial Fibrillation/surgery , Humans , Prospective Studies , Pulmonary Veins/surgery , Recurrence , Sulfonamides , Treatment Outcome
20.
Pacing Clin Electrophysiol ; 43(3): 297-307, 2020 03.
Article En | MEDLINE | ID: mdl-32045008

AIMS: In this study, we investigated the characteristics and underlying mechanisms of the electrocardiographic (ECG) morphology during left bundle branch area pacing (LBBAP), which have not been systematically described. METHODS: Patients with indications for permanent cardiac pacing underwent LBBAP attempts. The ECGs of patients with confirmed left bundle branch (LBB) capture were compared with those of individuals with right bundle branch block (RBBB) on 12-lead ECG. Intracardiac electrograms recorded during implantation were analyzed in all patients who underwent pacing. RESULTS: LBBAP was successfully achieved in 87.5% (56/64) of patients. The QRS morphologies in lead V1 during LBBAP, which typically demonstrated Qr (60.7%), qR (19.6%), rSR' (7.1%), or QS (12.5%) patterns, differed from those of native RBBB, which featured rsR' (57.5%), M shape (23.7%), or monophasic R patterns (18.7%). The terminal R' wave duration in lead V1 was significantly shorter during LBBAP than during native RBBB (51 ± 12 ms vs 85 ± 19 ms, p < 0.001). LBB potentials were recorded in 66.1% (37/56) of the LBBAP patients. No significant differences in ECG characteristics were found between LBBAP with and without recorded LBB potentials. The presence of bundle branch block during LBBAP significantly prolonged QRS duration, R wave peak time, and terminal R' wave duration in lead V1 . CONCLUSION: LBBAP-ECG patterns are characterized by a shorter terminal R' wave duration in lead V1 compared with that of native RBBB configurations. Bundle branch conduction integrity has an impact on ECG characteristics during LBBAP.


Bundle-Branch Block/physiopathology , Bundle-Branch Block/therapy , Cardiac Pacing, Artificial , Electrocardiography , Aged , Female , Humans , Male , Prospective Studies
...