Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
Biosens Bioelectron ; 222: 114990, 2023 Feb 15.
Article in English | MEDLINE | ID: mdl-36495719

ABSTRACT

Neurotransmitter serotonin (5-HT) is involved in various physiological and pathological processes. Therefore, its highly sensitive and selective detection in human serum is of great significance for early diagnosis of disease. In this work, employing iron phthalocyanine as Fe source, ultrafine Fe3O4 nanoparticles anchored on carbon spheres (Fe3O4/CSs) have been prepared, which exhibits an excellent electrochemical sensing performance toward 5-HT. With carbonecous spheres turned into conductive carbon spheres under the heat treatment in N2 atmosphere, iron phthalocyanine absorbed on their surfaces are simultaneously pyrolysised and oxidized, and finally transformed into ultrafine Fe3O4 nanoparticles. Electrochemical results demonstrate a high sensitivity (5.503 µA µM-1) and a low detection limit (4 nM) toward 5-HT for as-prepared Fe3O4/CSs. In combination with the morphology and physicochemical property of Fe3O4/CSs, the enhanced sensing mechanism toward 5-HT is disscussed. In addition, the developed electrochemical sensor also displays a good sensing stability and an anti-interferent ability. Further applied in real human serum samples, a satisfactory recovery rate is achieved. Promisingly, the developed electrochemical sensor can be employed for the determination of 5-HT in actual samples.


Subject(s)
Biosensing Techniques , Nanoparticles , Humans , Carbon/chemistry , Serotonin , Limit of Detection , Biosensing Techniques/methods , Electrochemical Techniques/methods , Electrodes
2.
Anal Chim Acta ; 1189: 339208, 2022 Jan 02.
Article in English | MEDLINE | ID: mdl-34815044

ABSTRACT

The electrochemical method for highly sensitive determination of arsenic(III) in real water samples with noble-metal-free nanomaterials is still a difficult but significant task. Here, an electrochemical sensor driven by noble-metal-free layered porous Fe3O4/Co3S4 nanosheets was successfully employed for As(III) analysis, which was prepared via a facile two-step method involves a hydrothermal treatment and a subsequent sulfurization process. As expected, the electrochemical detection of As(III) in 0.1 M HAc-NaAc (pH 6.0) by square wave anodic stripping voltammetry (SWASV) with a considerable sensitivity of 4.359 µA/µg·L-1 was obtained, which is better than the commonly used noble metals modified electrodes. Experimental and characterization results elucidate the enhancement of As(III) electrochemical performance could be attributed to its nano-porous structure, the presence of oxygen vacancies and strong synergetic coupling effects between Fe3O4 and Co3S4 species. Besides, the Fe3O4/Co3S4 modified screen printed carbon electrode (Fe3O4/Co3S4-SPCE) shows remarkable stability and repeatability, valuable anti-interference ability and could be used for detection in real water samples. Consequently, the results confirm that as-prepared porous Fe3O4/Co3S4 nanosheets is identified as a promising modifier to detect As(III) in real sample analysis.


Subject(s)
Electrochemical Techniques , Oxygen , Carbon , Electrodes , Gold
3.
Anal Chem ; 88(1): 906-14, 2016 Jan 05.
Article in English | MEDLINE | ID: mdl-26639029

ABSTRACT

Iron oxide with different crystal phases (α- and γ-Fe2O3) has been applied to electrode coatings and been demonstrated to ultrasensitive and selective electrochemical sensing toward heavy metal ions (e.g., Pb(II)). A range of Pb(II) contents in micromoles (0.1 to 1.0 µM) at α-Fe2O3 nanoflowers with a sensitivity of 137.23 µA µM(-1) cm(-2) and nanomoles (from 0.1 to 1.0 nM) at γ-Fe2O3 nanoflowers with a sensitivity of 197.82 µA nM(-1) cm(-2) have been investigated. Furthermore, an extended X-ray absorption fine structure (EXAFS) technique was applied to characterize the difference of local structural environment of the adsorbed Pb(II) on the surface of α- and γ-Fe2O3. The results first showed that α- and γ-Fe2O3 had diverse interaction between Pb(II) and iron (hydro)oxides, which were consistent with the difference of electrochemical performance. Determining the responses of Cu(II) and Hg(II) as the most appropriate choice for comparison, the stripping voltammetric quantification of Pb(II) with high sensitivity and selectivity at γ-Fe2O3 nanoflower has been demonstrated. This work reveals that the stripping performances of a nanomodifier have to be directly connected with its intrinsic surface atom arrangement.


Subject(s)
Electrochemical Techniques , Ferric Compounds/chemistry , Lead/analysis , Crystallization , Photoelectron Spectroscopy , X-Ray Absorption Spectroscopy
4.
Small ; 11(21): 2493-8, 2015 Jun 03.
Article in English | MEDLINE | ID: mdl-25630388

ABSTRACT

Facet-dependent stripping behavior in the determination of Pb(II): Well-defined Cu2O microcrystals with different structures show facet-dependent electrochemical behaviors toward heavy metal ions. This provides an important insight into the understanding the efficiency of facet-dependent properties of microcrystals on electroanalytical performance for the rational design of electrochemical analytical techniques for efficient detection of heavy metal ions.

5.
Adv Sci (Weinh) ; 2(5): 1500013, 2015 05.
Article in English | MEDLINE | ID: mdl-27980935

ABSTRACT

An impedimetric sensor for persistent toxic substances, including organic pollutants and toxic inorganic ions is presented. The persistent toxic substances are detected using an ultrasensitive technique that is based on electron-transfer blockage. This depends on the formation of guest-host complexes, hydrogen bonding, or a cyclodextrin (CD)-metal complex (Mm(OH)n-ß-CD) structure between the target pollutants and ß-CD.

6.
ACS Appl Mater Interfaces ; 6(15): 12203-13, 2014 Aug 13.
Article in English | MEDLINE | ID: mdl-25014119

ABSTRACT

This study attempts to understand the intrinsic impact of different morphologies of nanocrystals on their electrochemical stripping behaviors toward heavy metal ions. Two differently shaped Fe3O4 nanocrystals, i.e., (100)-bound cubic and (111)-bound octahedral, have been synthesized for the experiments. Electrochemical results indicate that Fe3O4 nanocrystals with different shapes show different stripping behaviors toward heavy metal ions. Octahedral Fe3O4 nanocrystals show better electrochemical sensing performances toward the investigated heavy metal ions such as Zn(II), Cd(II), Pb(II), Cu(II), and Hg(II), in comparison with cubic ones. Specifically, Pb(II) is found to have the best stripping performance on both the (100) and (111) facets. To clarify these phenomena, adsorption abilities of as-prepared Fe3O4 nanocrystals have been investigated toward heavy metal ions. Most importantly, combined with theoretical calculations, their different electrochemical stripping behaviors in view of facet effects have been further studied and enclosed at the level of molecular/atom. Finally, as a trial to find a disposable platform completely free from noble metals, the potential application of the Fe3O4 nanocrystals for electrochemical detection of As(III) in drinking water is demonstrated.


Subject(s)
Electrochemistry/methods , Metals, Heavy/chemistry , Nanoparticles/chemistry , Nanotechnology/methods , Adsorption , Cadmium/chemistry , Copper/chemistry , Crystallization , Drinking Water/chemistry , Electrodes , Environmental Monitoring , Ions , Lead/chemistry , Mercury/chemistry , Microscopy, Electron, Scanning , Software , Water Pollutants, Chemical/analysis , X-Ray Diffraction , Zinc/chemistry
7.
J Hazard Mater ; 278: 66-74, 2014 Aug 15.
Article in English | MEDLINE | ID: mdl-24953937

ABSTRACT

In Togtoh region of Inner Mongolia, northern China, groundwater encountered high concentrations As contamination (greater than 50 µg L(-1)) causes an increasing concern. This work demonstrates an electrochemical protocol for robust (efficient and accurate) determination of As(III) in Togtoh water samples using Au microwire electrode without the need of pretreatment or clean-up steps. Considering the complicated conditions of Togtoh water, the efficiency of Au microwire electrode was systematically evaluated by a series of interference tests, stability and reproducibility measurements. No obvious interference on the determination of As(III) was observed. Especially, the influence of humic acid (HA) was intensively investigated. Electrode stability was also observed with long-term measurements (70 days) in Togtoh water solution and under different temperatures (0-35 °C). Excellent reproducibility (RSD:1.28%) was observed from different batches of Au microwire electrodes. The results obtained at Au microwire electrode were comparable to that obtained by inductively coupled plasma atomic emission spectroscopy (ICP-AES), indicating a good accuracy. These evaluations (efficiency, robustness, and accuracy) demonstrated that the Au microwire electrode was able to determine As(III) in application to real environmental samples.


Subject(s)
Arsenic/analysis , Environmental Monitoring/instrumentation , Gold/chemistry , Groundwater/analysis , Water Pollutants, Chemical/analysis , Arsenic/chemistry , China , Electrochemistry , Electrodes , Environmental Monitoring/methods , Groundwater/chemistry , Reproducibility of Results , Water Pollutants, Chemical/chemistry
8.
J Hazard Mater ; 267: 153-60, 2014 Feb 28.
Article in English | MEDLINE | ID: mdl-24440655

ABSTRACT

A drawback of As(III) detection using square wave anodic stripping voltammetry (SWASV) is that it is susceptible to interferences from various metals or organic compounds, especially in real sample water. This study attempts to understand the interference of co-existing of Fe(III) and humic acid (HA) molecules to the electrochemical detection of As(III) using Fourier transform infrared (FTIR) spectrum and X-ray photoelectron spectroscopy (XPS). The electrochemical experiments include stripping of As(III) in the solutions containing HA with different concentrations, cyclic voltammetry in 0.5M H2SO4 in the presence of HA or Fe(III) with/without addition of Fe(III) or HA, and stripping of As(III) in the presence of HA or Fe(III) with/without addition of Fe(III) or HA. FTIR and XPS are employed to confirm the affinity of HA to Fe(III) or As(III) in acidic condition.


Subject(s)
Arsenic/chemistry , Ferric Compounds/chemistry , Gold/chemistry , Humic Substances/analysis , Arsenic/analysis , Electrochemistry , Electrodes , Gold/analysis , Hydrogen-Ion Concentration , Indicators and Reagents , Metals, Heavy/analysis , Organic Chemicals/analysis , Photoelectron Spectroscopy , Spectroscopy, Fourier Transform Infrared
9.
Sci Rep ; 3: 3115, 2013 Nov 01.
Article in English | MEDLINE | ID: mdl-24178058

ABSTRACT

Specific determination/monitoring of trace mercury ions (Hg(2+)) in environmental water is of significant importance for drinking safety. Complementarily to conventional inductively coupled plasma mass spectrometry and atomic emission/absorption spectroscopy, several methods, i.e., electrochemical, fluorescent, colorimetric, and surface enhanced Raman scattering approaches, have been developed recently. Despite great success, many inevitably encounter the interferences from other metal ions besides the complicated procedures and sophisticated equipments. Here we present a molecular-gap device for specific determination of trace Hg(2+) in both standardized solutions and environmental samples based on conductivity-modulated glutathione dimer. Through a self-assembling technique, a thin film of glutathione monolayer capped Au nanoparticles is introduced into 2.5 µm-gap-electrodes, forming numerous double molecular layer gaps. Notably, the fabricated molecular-gap device shows a specific response toward Hg(2+) with a low detection limit actually measured down to 1 nM. Theoretical calculations demonstrate that the specific sensing mechanism greatly depends on the electron transport ability of glutathione dimer bridged by heavy metal ions, which is determined by its frontier molecular orbital, not the binding energy.

10.
Small ; 9(13): 2233-9, 2013 Jul 08.
Article in English | MEDLINE | ID: mdl-23364917

ABSTRACT

SnO2 tube-in-tube nanostructures are synthesized using Cu@C nanocables as effective sacrificial templates. It is revealed by stripping voltammetry that SnO2 tube-in-tube nanostructures show excellent performances in the determination of heavy metal ions, which might be related to the extraordinary adsorbing capacities of the hollow structure to metal ions, i.e., metal ions could diffuse into the interior of tubular structure.

SELECTION OF CITATIONS
SEARCH DETAIL