ABSTRACT
resumen está disponible en el texto completo
Abstract This consensus of nomenclature and classification for congenital bicuspid aortic valve and its aortopathy is evidence-based and intended for universal use by physicians (both pediatricians and adults), echocardiographers, advanced cardiovascular imaging specialists, interventional cardiologists, cardiovascular surgeons, pathologists, geneticists, and researchers spanning these areas of clinical and basic research. In addition, as long as new key and reference research is available, this international consensus may be subject to change based on evidence-based data1.
ABSTRACT
This consensus of nomenclature and classification for congenital bicuspid aortic valve and its aortopathy is evidence-based and intended for universal use by physicians (both pediatricians and adults), echocardiographers, advanced cardiovascular imaging specialists, interventional cardiologists, cardiovascular surgeons, pathologists, geneticists, and researchers spanning these areas of clinical and basic research. In addition, as long as new key and reference research is available, this international consensus may be subject to change based on evidence-based data1.
Este consenso de nomenclatura y clasificación para la válvula aórtica bicúspide congénita y su aortopatía está basado en la evidencia y destinado a ser utilizado universalmente por médicos (tanto pediatras como de adultos), médicos ecocardiografistas, especialistas en imágenes avanzadas cardiovasculares, cardiólogos intervencionistas, cirujanos cardiovasculares, patólogos, genetistas e investigadores que abarcan estas áreas de investigación clínica y básica. Siempre y cuando se disponga de nueva investigación clave y de referencia, este consenso internacional puede estar sujeto a cambios de acuerdo con datos basados en la evidencia1.
ABSTRACT
BACKGROUND: Procedural improvements combined with the contemporary clinical profile of patients undergoing transcatheter aortic valve replacement (TAVR) may have influenced the incidence and outcomes of infective endocarditis (IE) following TAVR. We aimed to determine the temporal trends, characteristics, and outcomes of IE post-TAVR. METHODS: Observational study including 552 patients presenting definite IE post-TAVR. Patients were divided in 2 groups according to the timing of TAVR (historical cohort [HC]: before 2014; contemporary cohort [CC]: after 2014). RESULTS: Overall incidence rates of IE were similar in both cohorts (CC vs HC: 5.45 vs 6.52 per 1000 person-years; P = .12), but the rate of early IE was lower in the CC (2.29 vs 4.89, P < .001). Enterococci were the most frequent microorganism. Most patients presented complicated IE (CC: 67.7%; HC: 69.6%; P = .66), but the rate of surgical treatment remained low (CC: 20.7%; HC: 17.3%; P = .32). The CC exhibited lower rates of in-hospital acute kidney injury (35.1% vs 44.6%; P = .036) and in-hospital (26.6% vs 36.4%; P = .016) and 1-year (37.8% vs 53.5%; P < .001) mortality. Higher logistic EuroScore, Staphylococcus aureus etiology, and complications (stroke, heart failure, and acute renal failure) were associated with in-hospital mortality in multivariable analyses (P < .05 for all). CONCLUSIONS: Although overall IE incidence has remained stable, the incidence of early IE has declined in recent years. The microorganism, high rate of complications, and very low rate of surgical treatment remained similar. In-hospital and 1-year mortality rates were high but progressively decreased over time.
Subject(s)
Endocarditis , Transcatheter Aortic Valve ReplacementABSTRACT
BACKGROUND: No data exist about the characteristics of infective endocarditis (IE) post-transcatheter aortic valve replacement (TAVR) according to transcatheter valve type. We aimed to determine the incidence, clinical characteristics, and outcomes of patients with IE post-TAVR treated with balloon-expandable valve (BEV) versus self-expanding valve (SEV) systems. METHODS: Data from the multicenter Infectious Endocarditis After TAVR International Registry was used to compare IE patients with BEV versus SEV. RESULTS: A total of 245 patients with IE post-TAVR were included (SEV, 47%; BEV, 53%). The timing between TAVR and IE was similar between groups (SEV, 5.5 [1.2-15] months versus BEV, 5.3 [1.7-11.4] months; P=0.89). Enterococcal IE was more frequent in the SEV group (36.5% versus 15.4%; P<0.01), and vegetation location differed according to valve type (stent frame, SEV, 18.6%; BEV, 6.9%; P=0.01; valve leaflet, SEV, 23.9%; BEV, 38.5%; P=0.01). BEV recipients had a higher rate of stroke/systemic embolism (20.0% versus 8.7%, adjusted OR: 2.46, 95% CI: 1.04-5.82, P=0.04). Surgical explant of the transcatheter valve (SEV, 8.7%; BEV, 13.8%; P=0.21), and in-hospital death at the time of IE episode (SEV, 35.6%; BEV, 37.7%; P=0.74) were similar between groups. After a mean follow-up of 13±12 months, 59.1% and 54.6% of the SEV and BEV recipients, respectively, had died (P=0.66). CONCLUSIONS: The characteristics of IE post-TAVR, including microorganism type, vegetation location, and embolic complications but not early or late mortality, differed according to valve type. These results may help to guide the diagnosis and management of IE and inform future research studies in the field. (AU)
Subject(s)
Registries , Incidence , Endocarditis , Transcatheter Aortic Valve ReplacementABSTRACT
ABSTRACT: Bioprostheses are prone to structural valve degeneration, resulting in limited long-term durability. A significant challenge when comparing the durability of different types of bioprostheses is the lack of a standardized terminology for the definition of a degenerated valve. This issue becomes especially important when we try to compare the degeneration rate of surgically inserted and transcatheter bioprosthetic valves. This document, by the VIVID (Valve-in-Valve International Data), proposes practical and standardized definitions of valve degeneration and provides recommendations for the timing of clinical and imaging follow-up assessments accordingly. Its goal is to improve the quality of research and clinical care for patients with deteriorated bioprostheses by providing objective and strict criteria that can be utilized in future clinical trials. We hope that the adoption of these criteria by both the cardiological and surgical communities will lead to improved comparability and interpretation of durability analyses.
Subject(s)
Aortic Valve , Bioprosthesis , Transcatheter Aortic Valve Replacement , Research , EchocardiographyABSTRACT
IMPORTANCE: Limited data exist on clinical characteristics and outcomes of patients who had infective endocarditis after undergoing transcatheter aortic valve replacement (TAVR). OBJECTIVE: To determine the associated factors, clinical characteristics, and outcomes of patients who had infective endocarditis after TAVR. DESIGN, SETTING, AND PARTICIPANTS: The Infectious Endocarditis after TAVR International Registry included patients with definite infective endocarditis after TAVR from 47 centers from Europe, North America, and South America between June 2005 and October 2015. EXPOSURE: Transcatheter aortic valve replacement for incidence of infective endocarditis and infective endocarditis for in-hospital mortality. MAIN OUTCOMES AND MEASURES: Infective endocarditis and in-hospital mortality after infective endocarditis. RESULTS: A total of 250 cases of infective endocarditis occurred in 20 006 patients after TAVR (incidence, 1.1% per person-year; 95% CI, 1.1%-1.4%; median age, 80 years; 64% men). Median time from TAVR to infective endocarditis was 5.3 months (interquartile range [IQR], 1.5-13.4 months). The characteristics associated with higher risk of progressing to infective endocarditis after TAVR was younger age (78.9 years vs 81.8 years; hazard ratio [HR], 0.97 per year; 95% CI, 0.94-0.99), male sex (62.0% vs 49.7%; HR, 1.69; 95% CI, 1.13-2.52), diabetes mellitus (41.7% vs 30.0%; HR, 1.52; 95% CI, 1.02-2.29), and moderate to severe aortic regurgitation (22.4% vs 14.7%; HR, 2.05; 95% CI, 1.28-3.28). Health care-associated infective endocarditis was present in 52.8% (95% CI, 46.6%-59.0%) of patients...