Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 142
Filter
1.
Bioengineering (Basel) ; 11(9)2024 Sep 12.
Article in English | MEDLINE | ID: mdl-39329652

ABSTRACT

Current surgical practices in total knee arthroplasty (TKA) have advanced and include significant changes and improvements in alignment philosophies, femorotibial implant conformities, and ligament management to replicate in vivo knee kinematics. While corrective measures have emphasized sagittal plane alignment to restore normal flexion-extension (F-E) motion and coronal plane ligament balance, internal-external (I-E) rotation kinematics in the axial plane have been largely neglected. Recent in vivo evidence indicates that the combination of factors necessary to closely restore native tibial rotation as the knee flexes and extends is kinematic alignment (KA), which resurfaces the patient's pre-arthritic knee without releasing ligaments, an insert with medial 1:1 ball-in-socket conformity and a lateral flat surface, and posterior cruciate ligament (PCL) retention. However, the inherent anterior-posterior (A-P) stability provided by the medial 1:1 ball-in-socket limits the surgeon's ability to select the correct insert thickness using manual laxity testing. Accordingly, this review presents the design and validation of an instrument called an insert goniometer that measures I-E tibial rotation for inserts that differ in thickness by 1 mm and uses rotation limits at extension and 90° flexion to select the optimal insert thickness. The optimal thickness is the one that provides the greatest external tibial orientation in extension and internal tibial orientation at 90° flexion without lift-off of the insert.

2.
Article in English | MEDLINE | ID: mdl-39248217

ABSTRACT

PURPOSE: During kinematically aligned (KA) total knee arthroplasty (TKA), the surgeon may need to rectify an over-resection of the medial, lateral or posterior tibia. This study tested the hypothesis that a bone graft taken from the tibial resection or patella and impacted beneath a tibial baseplate would heal, regardless of whether the tibial component and knee were in outlier ranges according to mechanical alignment (MA) criteria. The study also tested the hypothesis that the Oxford Knee Score (OKS) and Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS JR) would improve beyond the substantial clinical benefit and that the source and thickness of the bone graft would not influence their improvement. METHODS: This retrospective study radiographically assessed the healing of a bone graft from the tibial resection (n = 19) or patella (n = 10) in 29 KA TKAs (18 females, mean age 65 years). The tibial component and knee alignment were categorized as in-range or outliers based on reported MA criteria for bone graft healing and implant survival. The one-sample t test identified differences in the improvement of the OKS and KOOS JR from their reported substantial clinical benefit of 16 and 20 points, respectively. RESULTS: At an average follow-up of 37 months, all bone grafts healed even though ≥55% of tibial components and 34% of knees were varus outliers according to MA criteria for bone healing and implant survival. Amongst the 29 patients, the mean OKS and KOOS JR improvements of 25 ± 11 and 47 ± 21 points, respectively, surpassed the threshold of their respective substantial clinical benefit (p < 0.01) and were not influenced by the bone graft's source and thickness (p ≥ 0.51). CONCLUSIONS: During cemented KA TKA, the surgeon can use a bone graft from the tibial resection or patella to rectify a tibial over-resection. This technique led to consistent bone healing and improved outcome scores. LEVEL OF EVIDENCE: Level IV.

3.
J Knee Surg ; 2024 Sep 27.
Article in English | MEDLINE | ID: mdl-39163998

ABSTRACT

When performing caliper-verified kinematically aligned total knee arthroplasty (KA TKA) in the osteoarthritic (OA) knee with valgus deformity, an elongated medial collateral ligament (MCL) could result in a valgus setting of the tibial component. The present study analyzed KA TKA in patients with valgus deformities (i.e., tibiofemoral angle > 10 degrees of valgus) and determined (1) the occurrence of radiographic MCL elongation, (2) the incidence of lateral collateral ligament (LCL) and posterior cruciate ligament (PCL) release and the use of constrained components, and (3) whether the 1-year Forgotten Joint Score (FJS), Oxford Knee Score (OKS), Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS JR), and Likert satisfaction score were comparable to KA TKAs for OA deformities ≤10 degrees of valgus. One hundred and two consecutive patients who underwent KA TKA by a single surgeon were analyzed radiographically and clinically at a minimum follow-up of 1 year. Radiographic MCL elongation was identified by a greater than 1 degree of valgus orientation of the tibial component relative to the OA tibial joint line. Twenty-six patients had a radiographic anatomic tibiofemoral angle greater than 10 degrees of valgus (range of OA deformity: 11-23 degrees of valgus). Seventy-six had an OA deformity ≤10 degrees of valgus (10-degree valgus to -14-degree varus). No patient had MCL elongation or a ligament release, or required constrained components. The median FJS of 78, OKS of 42, and KOOS JR of 76, and the 85% satisfaction rate of the patients with greater than 10 degrees of OA valgus deformity were not significantly different from those with ≤10 degrees of OA valgus deformity (p ≥ 0.17). Because MCL elongation was not detected in OA deformities up to 23 degrees of valgus, the risk of under-correcting the valgus deformity leading to instability and poor outcome scores is low when performing KA TKA using primary components without releasing the LCL and/or PCL. LEVEL OF EVIDENCE:: IV.

4.
J Biomech Eng ; 146(11)2024 Nov 01.
Article in English | MEDLINE | ID: mdl-38959087

ABSTRACT

Goals of knee replacement surgery are to restore function and maximize implant longevity. To determine how well these goals are satisfied, tibial femoral kinematics and tibial contact kinematics are of interest. Tibiofemoral kinematics, which characterize function, is movement between the tibia and femur whereas tibial contact kinematics, which is relevant to implant wear, is movement of the location of contact by the femoral implant on the tibial articular surface. The purposes of this review article are to describe and critique relevant methods to guide correct implementation. For tibiofemoral kinematics, methods are categorized as those which determine (1) relative planar motions and (2) relative three-dimensional (3D) motions. Planar motions are determined by first finding anterior-posterior (A-P) positions of each femoral condyle relative to the tibia and tracking these positions during flexion. Of the lowest point (LP) and flexion facet center (FFC) methods, which are common, the lowest point method is preferred and the reasoning is explained. 3D motions are determined using the joint coordinate system (JCS) of Grood and Suntay. Previous applications of this JCS have resulted in motions which are largely in error due to "kinematic crosstalk." Requirements for minimizing kinematic crosstalk are outlined followed by an example, which demonstrates the method for identifying a JCS that minimizes kinematic crosstalk. Although kinematic crosstalk can be minimized, the need for a JCS to determine 3D motions is questionable based on anatomical constraints, which limit varus-valgus rotation and compression-distraction translation. Methods for analyzing tibial contact kinematics are summarized and validation of methods discussed.


Subject(s)
Femur , Tibia , Tibia/physiology , Tibia/diagnostic imaging , Biomechanical Phenomena , Humans , Fluoroscopy , Femur/physiology , Femur/diagnostic imaging , Mechanical Phenomena , Knee Joint/physiology , Knee Joint/diagnostic imaging
5.
J Biomech Eng ; 146(11)2024 Nov 01.
Article in English | MEDLINE | ID: mdl-38913074

ABSTRACT

In designing femoral components, which restore native (i.e., healthy) knee kinematics, the flexion-extension (F-E) axis of the tibiofemoral joint should match that of the native knee. Because the F-E axis is governed by the curvature of the femoral condyles in the sagittal plane, the primary objective was to determine the variation in radii of curvature. Eleven high accuracy three-dimensional (3D) femur models were generated from ultrahigh resolution CT scans. The sagittal profile of each condyle was created. The radii of curvature at 15 deg increments of arc length were determined based on segment circles best-fit to ±15 deg of arc at each increment. Results were standardized to the radius of the best-fit overall circle to 15 deg-105 deg for the femoral condyle having a radius closest to the mean radius. Medial and lateral femoral condyles exhibited multiradius of curvature sagittal profiles where the radius decreased at 30 deg flexion by 10 mm and at 15 deg flexion by 8 mm, respectively. On either side of the decrease, radii of segment circles were relatively constant. Beyond the transition angles where the radii decreased, the anterior-posterior (A-P) positions of the centers of curvature varied 4.8 mm and 2.3 mm for the medial and lateral condyles, respectively. A two-radius of curvature profile approximates the radii of curvature of both native femoral condyles, but the transition angles differ with the transition angle of the medial femoral condyle occurring about 15 deg later in flexion. Owing to variation in A-P positions of centers of curvature, the F-E axis is not strictly fixed in the femur.


Subject(s)
Femur , Femur/anatomy & histology , Femur/diagnostic imaging , Femur/physiology , Humans , Biomechanical Phenomena , Male , Knee Joint/anatomy & histology , Knee Joint/physiology , Knee Joint/diagnostic imaging , Tomography, X-Ray Computed , Female , Models, Anatomic , Imaging, Three-Dimensional
6.
J Pers Med ; 14(5)2024 May 10.
Article in English | MEDLINE | ID: mdl-38793086

ABSTRACT

BACKGROUND: for kinematic alignment (KA) total knee arthroplasty (TKA), it was unknown whether 'the pace of recovery' at six weeks was different for patients with ages ranging between 50-59, 60-69, 70-79, and 80-89 years who were discharged on the surgery day and self-administered their rehabilitation. METHODS: a single surgeon treated 206 consecutive patients with a KA-designed femoral component and an insert with a medial ball-in-socket, lateral flat articulation, and PCL retention. Each filled out preoperative and six-week Oxford Knee Score (OKS), Knee Society Score (KSS), Knee Function Score (KFS), and Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS, JR) questionnaires. The six-week minus preoperative value indicated improvement. RESULTS: between age cohorts, the improvement was not different (p = 0.2319 to 0.9888). The mean improvement/six-week postoperative value was 6°/-2° for knee extension, 0°/119° for knee flexion, 7/31 for the OKS, 39/96 for the KSS, 7/64 for the KFS, and 13/62 for the KOOS. The 30-day hospital readmission rate was 1%. CONCLUSION: surgeons who perform KA TKA can counsel 50 to 89-year-old patients that they can be safely discharged home on the surgery day with a low risk of readmission and can achieve better function at six weeks than preoperatively when performing exercises without a physical therapist.

7.
Clin Biomech (Bristol, Avon) ; 113: 106215, 2024 03.
Article in English | MEDLINE | ID: mdl-38428263

ABSTRACT

BACKGROUND: In total knee arthroplasty, unrestricted kinematic alignment aims to restore pre-arthritic lower limb alignment and joint lines. Joint line orientations of the contralateral healthy proximal tibia might be used to evaluate accuracy of tibial component alignment post-operatively if asymmetry is minimal. Our objective was to evaluate left-to-right asymmetry of the proximal tibial epiphysis in posterior tibial slope and varus-valgus orientation as related to unrestricted kinematic alignment principles. METHODS: High resolution CT images (0.5 mm slice thickness) were acquired from bilateral lower limbs of 11 skeletally mature subjects with no skeletal abnormalities. Images were segmented to generate 3D tibia models. Asymmetry was quantified by differences in orientations required to shape-match the proximal epiphysis of the mirror 3D tibia model to the proximal epiphysis of the contralateral 3D tibia model. FINDINGS: Systematic and random differences (i.e. mean ± standard deviation) in tibial slope and varus-valgus orientation were - 0.8° ± 1.2° and - 0.2° ± 0.8°, respectively. Ninety five percent confidence intervals on the means included 0° indicating that systematic differences were minimal. INTERPRETATION: Since random differences due to asymmetry are substantial in relation to random surgical deviations from pre-arthritic joint lines previously reported, post-operative computer tomograms of the contralateral healthy tibia should not be used to directly assess accuracy of tibial component alignment on a group level without correcting for differences in tibial slope and varus-valgus orientation due to asymmetry.


Subject(s)
Arthroplasty, Replacement, Knee , Osteoarthritis, Knee , Humans , Tibia/diagnostic imaging , Tibia/surgery , Biomechanical Phenomena , Knee Joint/diagnostic imaging , Knee Joint/surgery , Arthroplasty, Replacement, Knee/methods , Epiphyses/diagnostic imaging , Epiphyses/surgery , Osteoarthritis, Knee/surgery
9.
Knee Surg Sports Traumatol Arthrosc ; 32(3): 693-703, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38415963

ABSTRACT

PURPOSE: Assessing the risk of tibial baseplate loosening in patients after unrestricted kinematically aligned (unKA) total knee arthroplasty (TKA) using a medially conforming insert is important because baseplates generally are aligned in varus which has been linked to an increased incidence of aseptic loosening following mechanically aligned TKA. Two limits that indicate long-term stability in patients are a change in maximum total point motion between 1 and 2 years (ΔMTPM) < 0.2 mm and anterior tilt at 2 years < 0.8°. The purposes were to determine: (1) the number of patients with ΔMTPM > 0.2 mm, (2) the number of patients with anterior tilt > 0.8° and (3) whether increased varus baseplate and limb alignment were associated with increased migration. METHODS: Thirty-five patients underwent cemented, caliper-verified, unKA TKA using a medially conforming tibial insert with posterior cruciate ligament (PCL) retention. Biplanar radiographs acquired on the day of surgery and at 1.5, 3, 6, 12 and 24 months were processed with model-based radiostereometric analysis (RSA) software to determine migration and the number of patients with migration above the two stability limits. Medial proximal tibial angle (MPTA), hip-knee-ankle angle (HKAA) and posterior slope angle (PSA) were analyzed for an association with migration in six degrees of freedom and in MTPM. RESULTS: Thirty-two of 35 patients were available for analysis at 2 years. One patient exhibited ΔMTPM > 0.2 mm. The same patient exhibited anterior tilt > 0.8°. Varus rotation (p = 0.048, r ≤ 0.34) and medial translation (p = 0.0273, r ≤ 0.29) increased with increased varus baseplate alignment. CONCLUSION: The results indicate low risk of long-term baseplate loosening in patients. Although varus rotation and medial translation increased with increased varus baseplate alignment, the magnitudes of the migrations were minimal and did not increase ΔMTPM and anterior tilt. LEVEL OF EVIDENCE: Level II, therapeutic prospective cohort study.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Humans , Arthroplasty, Replacement, Knee/methods , Radiostereometric Analysis , Knee Prosthesis/adverse effects , Biomechanical Phenomena , Prospective Studies , Knee Joint/surgery , Tibia/surgery , Osteoarthritis, Knee/surgery
10.
Proc Inst Mech Eng H ; 238(3): 332-339, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38373882

ABSTRACT

One common method to determine tibiofemoral kinematics following total knee replacement (TKR) is to capture single-plane fluoroscopic images of a patient activity and determine anterior-posterior (AP) positions of the femoral condyles and internal-external (IE) tibial rotation. Although JointTrack is widely used to analyze such images, precision (i.e. repeatability) in determining AP positions and IE tibial rotations using the two publicly available programs has never been quantified. The objectives were to determine the precision and reproducibility of results using both programs. Fluoroscopic images of 16 patients who performed a weight-bearing deep knee bend following TKR were analyzed. JointTrack Manual (JTM) and JointTrack Machine Learning (JTML) were used to perform 3D model-to-2D image registration after which AP positions of the femoral condyles and IE tibial rotations were determined. Precision in AP positions and IE rotations was quantified. Intraclass correlation coefficients (ICCs) for both repeatability (i.e. intraobserver) and reproducibility (i.e. interobserver) also were determined. Precision using JTM was worse than JTML for AP positions of the medial and lateral femoral condyles (1.0 mm and 0.9 mm vs 0.3 mm and 0.4 mm, respectively; p < 0.001 for both). For IE tibial rotation, precision also was worse using JTM versus JTML (1.1º vs 0.9°, p = 0.010). ICC values for JTML indicated good to excellent agreement (range: 0.82-0.98) whereas ICC values for JTM indicated only moderate to good agreement (range: 0.58-0.88). JTML has better precision and reproducibility than JTM and also is more efficient to use. Therefore, use of JTML over JTM is strongly recommended.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Humans , Biomechanical Phenomena , Reproducibility of Results , Range of Motion, Articular , Knee Joint/diagnostic imaging , Knee Joint/surgery , Tibia/diagnostic imaging , Tibia/surgery , Femur/diagnostic imaging , Femur/surgery , Fluoroscopy/methods , Software
11.
Bioengineering (Basel) ; 11(1)2024 Jan 08.
Article in English | MEDLINE | ID: mdl-38247939

ABSTRACT

Because kinematic alignment (KA) aligns femoral components in greater valgus and with less external rotation than mechanical alignment (MA), the trochlear groove of an MA design used in KA is medialized, which can lead to complications. Hence, a KA design has emerged. In this study, our primary objective was to quantify differences in trochlear morphology between the KA design and the MA design from which the KA design evolved. The KA and MA designs were aligned in KA on ten 3D femur-cartilage models. Dependent variables describing the morphology of the trochlea along the anterior flange, which extends proximal to the native trochlea, and along the arc length of the native trochlea, were determined, as was flange coverage. Along the anterior flange, the KA groove was significantly lateral proximally by 10 mm and was significantly wider proximally by 5 mm compared to the MA design (p < 0.0001). Along the arc length of the native trochlea, the KA groove was significantly lateral to the MA design by 4.3 mm proximally (p ≤ 0.0001) and was significantly wider proximally by 19 mm than the MA design. The KA design reduced lateral under-coverage of the flange from 4 mm to 2 mm (p < 0.0001). The KA design potentially mitigates risk of patellofemoral complications by lateralizing and widening the groove to avoid medializing the patella for wide variations in the lateral distal femoral angle, and by widening the flange laterally to reduce under-coverage. This information enables clinicians to make informed decisions regarding use of the KA design.

12.
J Arthroplasty ; 39(3): 695-700, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37659680

ABSTRACT

BACKGROUND: The preceding study reported a 10-year follow-up of 222 kinematically aligned total knee arthroplasties (TKA) performed in 217 patients in 2007. As 35% of tibial components and 8% of limbs were in >3° varus, the present study assessed whether this adversely affected reoperation, implant survival, and function at 16 years. METHODS: We retrospectively reviewed a single surgeon's private practice database to determine the patients who underwent reoperation as well as Forgotten Joint Score and Oxford Knee Score. RESULTS: There were 7 patients who had a major reoperation (revision of a loose tibial component [n = 2], and revision of well-fixed component due to stiffness [n = 1], patella instability [n = 1], pain [n = 1], and infection [n = 2]). There were 5 who had a minor reoperation that retained the components, and 91 patients (94 TKAs) died. Implant survivorship was 93% using reoperation for any reason as the endpoint. The median (interquartile range) Forgotten Joint and Oxford Knee scores were 88 (57 to 100) and 45 (39 to 48) points, respectively. CONCLUSION: The kinematically aligned TKA had a 7% reoperation rate at 16 years follow-up, comparable to or lower than reports of mechanically aligned TKA, which supports the concept of the unrestricted version of kinematic alignment in which the patient's prearthritic alignment is fully restored regardless of deformity.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Humans , Reoperation , Knee Joint/surgery , Retrospective Studies , Follow-Up Studies , Biomechanical Phenomena , Osteoarthritis, Knee/surgery
13.
J Exp Orthop ; 10(1): 115, 2023 Nov 15.
Article in English | MEDLINE | ID: mdl-37964140

ABSTRACT

PURPOSE: In total knee arthroplasty (TKA) with posterior cruciate ligament (PCL) retention, the medial and lateral insert conformity that restores in vivo native (i.e., healthy) knee tibial rotation and high function without causing stiffness is unknown. The purpose was to determine whether a ball-in-socket (B-in-S) medially conforming (MC) and flat lateral insert implanted with unrestricted kinematic alignment (KA) TKA and PCL retention restores tibial rotation to native. METHODS: One group of 25 patients underwent unrestricted KA TKA with manual instruments. Another group of 25 patients had native knees. Single-plane fluoroscopy imaged each knee while patients performed step-up and chair rise activities. Following 3D model-to-2D image registration, anterior-posterior (A-P) positions of the femoral condyles were determined. Changes in A-P positions with flexion were used to determine tibial rotation. RESULTS: At maximum flexion, mean tibial rotations of KA TKA knees were comparable to native knees (Step up: 12.3° ± 4.4° vs. 13.1° ± 12.0°, p = 0.783; Chair Rise: 12.7° ± 6.2° vs. 12.6° ± 9.5º, p = 0.941). However, paths of rotation differed in that screw home motion was less evident in KA TKA knees. At 8 months follow-up, the median Forgotten Joint Score was 69 points (range 65 to 85), the median Oxford Knee Score was 43 points (range 40 to 46), and mean knee flexion was 127º ± 8°. CONCLUSIONS: The ball-in-socket medial, flat lateral insert and PCL retention implanted with unrestricted KA TKA restored in vivo native knee tibial rotation at maximum flexion for each activity and high function without stiffness. Providing high A-P stability, this implant design might benefit patients desiring to return to demanding work and recreational activities. LEVEL OF EVIDENCE: Therapeutic - Level II.

14.
Knee Surg Sports Traumatol Arthrosc ; 31(12): 5438-5445, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37792084

ABSTRACT

PURPOSE: The primary aim was to analyze unrestricted kinematic alignment (unKA) total knee arthroplasty (TKA) and determine the frequency of medial deviation of the prosthetic trochlear angle (PTA) of the femoral component relative to the quadriceps vector (QV) that terminates at the anterior inferior iliac spine (AIIS), and whether patients with medial deviation had a worse Forgotten Joint Score (FJS) and Oxford Knee Score (OKS) relative to those with lateral deviation. The secondary aim was to determine the frequency of medial deviation for mechanical alignment (MA) TKA simulations. METHODS: From a database of a single surgeon, the study extracted de-identified data on 147 patients with a CT scanogram showing the pelvis and AIIS, a limb with an unKA TKA, and a native (i.e., healthy) opposite limb. On the scanogram, an examiner, blinded to the PROMs, measured the PTA-QV angle on the unKA TKA and on the opposite limb simulated MA TKA by drawing the PTA at 6° valgus relative to the femoral mechanical axis and measuring the PTA-QV angle. RESULTS: Medial deviation of the PTA occurred in 86% of patients with unKA TKA, and the 126 with medial deviation had a 17/1 point worse median FJS/OKS than the 21 with lateral deviation at a mean follow-up of 47 ± 8 months, respectively (p < 0.0001, p = 0.0053). In addition, 21%, 17%, and 8% of MA TKA had medial deviation after radiographic simulation using reported surgical errors for manual, patient-specific, and robotic instrumentation, respectively. CONCLUSION: In most patients with unKA TKA and a smaller proportion with MA TKA, a PTA of 6° valgus was medial to the QV, which, by excluding the patient's Q-angle, might alter patellofemoral kinematics like an incorrectly oriented trochleoplasty. The 17-point worse FJS in the patients with an unKA TKA and medial deviation of the PTA suggests the surgical target should be to orient the PTA lateral to the QV. LEVEL OF EVIDENCE: IV.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Humans , Knee Joint/diagnostic imaging , Knee Joint/surgery , Femur/surgery , Tomography, X-Ray Computed , Quadriceps Muscle/diagnostic imaging , Quadriceps Muscle/surgery , Biomechanical Phenomena , Osteoarthritis, Knee/diagnostic imaging , Osteoarthritis, Knee/surgery
15.
J Biomech Eng ; 145(12)2023 Dec 01.
Article in English | MEDLINE | ID: mdl-37792485

ABSTRACT

Radiostereometric analysis (RSA) measures movement (migration) of a baseplate relative to the underlying tibia after total knee arthroplasty (TKA) and has been used extensively to evaluate safety of new implant designs and/or surgical techniques regarding baseplate loosening. Because RSA is a complex methodology which involves various choices that researchers make, including whether to use marker-based or model-based methods, which migration metric to report, how to relate short-term migrations to long-term risk, and how these choices impact error, the objectives of this review were to: (1) lay out a comprehensive structure illustrating the multiple components/considerations for RSA and their interrelations, (2) review components of the structure using the latest RSA literature, and (3) use the preceding review as a context for identifying future areas of study. The components to be reviewed were structured using the following topics: type of RSA, migration metrics, sources of error, studies/reports of error, stability limits, and studies of error in stability limits. Based on the current RSA literature and knowledge gaps which exist, the following future research directions were identified: (1) revising the ISO standard to require reporting of clinical measurement error (bias) and recommending use of a local baseplate coordinate system, (2) identifying the migration metric and associated threshold most predictive of baseplate loosening for individual patients, (3) creating a method for data sharing to improve individual patient diagnostics, and (4) determining an appropriate stability limit for model-based RSA for group stability and individual patient diagnostics.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Humans , Knee Joint , Radiostereometric Analysis , Tibia/diagnostic imaging , Tibia/surgery , Arthroplasty, Replacement, Knee/methods , Prosthesis Failure
16.
J Arthroplasty ; 38(12): 2612-2617, 2023 12.
Article in English | MEDLINE | ID: mdl-37321516

ABSTRACT

BACKGROUND: There are no reports as to whether the condition of the anterior cruciate ligament (ACL) adversely affects the 2 to 3 year function and reoperation risk of a kinematically aligned (KA) total knee arthroplasty (TKA) performed with posterior cruciate ligament (PCL) retention and an intermediate medial conforming (MC) insert. METHODS: A single surgeon's prospective database query identified 418 consecutive primary TKAs performed between January 2019 and December 2019. The surgeon recorded the ACL condition in the operative note. Patients filled out the Forgotten Joint Score (FJS), Oxford knee score (OKS), and Knee Injury and Osteoarthritis Outcome Scores for Joint Replacement at the final follow-up. There were 299 patients with an intact ACL, 99 with a torn ACL, and 20 with a reconstructed ACL. The mean follow-up was 31 months (range, 20 to 45). RESULTS: The median FJS, OKS, and Knee Injury and Osteoarthritis Outcome Score (KOOS) of the reconstructed/torn/intact KA TKAs were 90/79/67, 47/44/43, and 92/88/80 points, respectively. The median OKS and KOOS of the reconstructed ACL cohort were 4 and 11 points higher than in the intact ACL cohort (P = .003, .04). One patient who had a reconstructed ACL underwent manipulation under anesthesia (MUA) for stiffness. The 5 reoperations in the intact ACL cohort were for instability (n = 2), revision after failed MUA for stiffness (n = 2), and infection (n = 1). CONCLUSION: These results suggest that patients who have a torn and reconstructed ACL can expect high function and a low risk of reoperation comparable to patients who have an intact ACL when treated with unrestricted, caliper-verified KA, PCL retention, and an intermediate MC insert.


Subject(s)
Anterior Cruciate Ligament Injuries , Anterior Cruciate Ligament Reconstruction , Arthroplasty, Replacement, Knee , Knee Injuries , Osteoarthritis, Knee , Osteoarthritis , Humans , Anterior Cruciate Ligament/surgery , Arthroplasty, Replacement, Knee/adverse effects , Knee Joint/surgery , Reoperation/adverse effects , Incidence , Anterior Cruciate Ligament Injuries/complications , Anterior Cruciate Ligament Reconstruction/adverse effects , Knee Injuries/surgery , Osteoarthritis/surgery , Treatment Outcome , Osteoarthritis, Knee/surgery , Osteoarthritis, Knee/etiology
17.
Int Orthop ; 47(7): 1737-1746, 2023 07.
Article in English | MEDLINE | ID: mdl-37195465

ABSTRACT

PURPOSE: For a new tibial insert design with ball-in-socket (B-in-S) medial conformity (MC), posterior cruciate ligament (PCL) retention, and flat lateral articular surface (B-in-S MC + PCL), this study determined whether internal tibial rotation and knee flexion were limited and clinical outcome scores were lower during weight-bearing activities relative to an insert with intermediate (I) (i.e., less than ball-in-socket) medial conformity (I MC + PCL). METHODS: Twenty-five patients were treated with bilateral unrestricted, caliper-verified kinematic alignment (KA) total knee arthroplasty (TKA) with an I MC + PCL insert and B-in-S MC + PCL insert in opposite knees. Each patient performed weight-bearing deep knee bend, step up, and chair rise under single-plane fluoroscopy. Analysis following 3D model-to-2D image registration determined internal tibial rotation. For each TKA, knee flexion was measured and patients completed clinical outcome scoring questionnaires. RESULTS: Internal tibial rotation did not differ between conformities during chair rise and step up (p = 0.3419 and 0.1030, respectively). During deep knee bend, internal tibial rotation between 90° and maximum flexion was 3° greater in the B-in-S MC + PCL group (18° vs 15°) (p = 0.0290). Mean knee flexion (p = 0.3115) and median Forgotten Joint Score (FJS), Oxford Knee Score (OKS), and Western Ontario and McMasters Universities Arthritis Index (WOMAC) scores (p = 0.2100, 0.2154, and 0.4542, respectively) did not differ between conformities. CONCLUSION: An insert with ball-in-socket medial conformity, which maximizes anteroposterior (AP) stability, did not limit internal tibial rotation and knee flexion and did not lower patient-reported outcomes when implanted with unrestricted caliper-verified KA and PCL retention. The high AP stability provided by the medial ball-in-socket might interest those surgeons exploring the treatment of the active patient with a desire to return to high-level and athletic activities.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Posterior Cruciate Ligament , Humans , Posterior Cruciate Ligament/surgery , Arthroplasty, Replacement, Knee/methods , Rotation , Knee Joint/surgery , Tibia/surgery , Range of Motion, Articular , Biomechanical Phenomena
18.
Knee ; 42: 193-199, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37054496

ABSTRACT

BACKGROUND: One method for assessing the accuracy of manual, patient-specific, navigational, and robotic-assisted total knee arthroplasty (TKA) instrumentation is to use a post-operative computer tomogram and determine the deviation of the femoral component alignment relative to the planned alignment in the native (i.e. healthy) contralateral distal femoral epiphysis. However, side-to-side asymmetry might introduce errors which inflate alignment deviations. This study quantified asymmetry in the distal femoral epiphysis. METHODS: High resolution CT images (0.5 mm slice thickness) were acquired from bilateral lower limb specimens of 13 skeletally mature subjects with no skeletal abnormalities. Images were segmented to generate 3D femur models. Asymmetry was quantified by differences in positions and orientations required to shape-match the distal epiphysis of the mirror 3D femur model to the distal epiphysis of the contralateral 3D femur model. RESULTS: Asymmetry was due to random rather than systematic differences. Random differences (i.e. standard deviations) in proximal-distal (P-D) and anterior-posterior (A-P) positions were 1.1 mm and in varus-valgus (V-V) and internal-external (I-E) orientations were 0.9° and 1.3°, respectively. These represented substantial relative errors of up to 50 % in previously reported overall alignment deviations. CONCLUSIONS: Although small in an absolute sense, asymmetry of the distal femur epiphysis introduced substantial relative errors when assessing accuracy of femoral component alignment in TKA. When post-operative computer tomograms are used to assess the accuracy of manual, patient specific, navigational, and robotic-assisted TKA instrumentation, the overall deviation should be corrected for asymmetry to better indicate the accuracy of the surgical technique.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Humans , Knee Joint/diagnostic imaging , Knee Joint/surgery , Biomechanical Phenomena , Arthroplasty, Replacement, Knee/methods , Femur/diagnostic imaging , Femur/surgery
19.
J Biomech Eng ; 145(6)2023 06 01.
Article in English | MEDLINE | ID: mdl-36719252

ABSTRACT

Radiostereometric analysis can be used for computing movement of a tibial baseplate relative to the tibia (termed migration) to determine stability of fixation. Quantifying migration in six degrees of freedom requires establishing a coordinate system in which to express the movement. Establishing consistent migration directions among patients and baseplate designs remains challenging. Deviations in imaging alignment (tibia/baseplate alignment during image acquisition) and surgical alignment (baseplate alignment on tibia) will affect computed migrations when using the conventional globally-aligned baseplate coordinate system (BCS) (defined by calibration box). Computing migration using a local BCS (defined by baseplate) may be preferrable. This paper (1) summarizes the migration equations when using a globally-aligned versus local BCS, (2) proposes a method for defining a local BCS, and (3) demonstrates differences in the two BCSs for an example patient whose baseplate has rotational deviations due to imaging or surgical alignments. Differences in migration for the two BCSs ranged from about ±0.5 mm in translations and -0.4 deg to 0.7 deg in rotations. Differences were largest for deviations in internal-external rotation and smallest for deviations in varus-valgus rotation. An example demonstrated that the globally-aligned BCS resulted in migration being quantified as subsidence instead of liftoff, thereby changing fundamental interpretations. Because migrations computed using a local BCS are independent of imaging and surgical alignments and instead characterize migration using baseplate features, a local BCS enhances consistency in migration directions among patients and baseplate designs relative to the interface in which fixation may be compromised.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Humans , Arthroplasty, Replacement, Knee/methods , Knee Joint , Radiostereometric Analysis , Tibia/diagnostic imaging , Tibia/surgery
20.
Knee Surg Sports Traumatol Arthrosc ; 31(4): 1433-1442, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36201009

ABSTRACT

PURPOSE: Varus alignment of the tibial baseplate and limb > 3° might adversely affect baseplate fixation after total knee arthroplasty (TKA), especially for unrestricted kinematically aligned (KA) TKA which aligns a majority of baseplates in varus. The purposes of this study were to determine whether baseplate migration at 1 year (1) was significantly less than a stability limit of 0.5 mm, (2) increased over time, and (3) was related to varus alignment of the baseplate and limb after unrestricted KA TKA. METHODS: Thirty-five patients underwent unrestricted KA TKA using a fixed-bearing, cemented, medial conforming tibial insert with posterior cruciate ligament retention. Using model-based radiostereometric analysis, maximum total point motion (MTPM) (i.e., largest displacement on the baseplate) was computed at 6 weeks, 3 months, 6 months, and 1 year postoperatively relative to the day of surgery. Baseplate and limb alignment were measured postoperatively on long-leg CT scanograms. RESULTS: At 1 year, mean MTPM of 0.35 mm was significantly less than the 0.5 mm stability limit (p = 0.0002). Mean MTPM did not increase from 6 weeks to 1 year (p = 0.3047). Notably, 89% (31/35) of tibial baseplates and 46% (16/35) of limbs were > 3° varus. Baseplate and limb alignment had no relationship to MTPM at 1 year (|r|≤ 0.173, p ≥ 0.3276). CONCLUSION: Low and non-progressive tibial baseplate migration 1 year after unrestricted KA TKA with a medial conforming design should allay any concern that unrestricted KA TKA increases risk of baseplate loosening due to varus alignment of the baseplate and limb. LEVEL OF EVIDENCE: Level II, therapeutic prospective cohort study.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Humans , Knee Joint/diagnostic imaging , Knee Joint/surgery , Prospective Studies , Tibia/surgery , Biomechanical Phenomena , Osteoarthritis, Knee/surgery
SELECTION OF CITATIONS
SEARCH DETAIL