Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 37
Filter
1.
J Hand Surg Glob Online ; 6(4): 466-470, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39166185

ABSTRACT

We present two cases of complex metacarpal fractures treated with an intramedullary locking nail. This is an emerging fixation method that minimizes tissue insult, provides sufficient stability, and allows early mobilization. Locking nails accommodate the capture of fractured fragments in complex unstable patterns and provide longitudinal and rotational stability. The described intrafocal technique is intended to improve coaxial placement of the wire into the medullary canal.

2.
J Orthop Trauma ; 38(9S): S15-S20, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-39150289

ABSTRACT

SUMMARY: Longitudinal forearm instability is a consequence of interosseous ligament complex disruption. Radiographic identifiers should alert the surgeon to the disrupted structures. Understanding the injury pattern can simplify the treatment process. The clinical presentation will vary based on the involved interosseous ligament components. The surgeon should aim to restore the anatomic radioulnar relationship and then address the remaining pathology as needed. The central band is the foundational structure that maintains this relationship and should be addressed in each injury pattern when disrupted. In this study, we describe rare forms of longitudinal forearm instability.


Subject(s)
Forearm Injuries , Joint Instability , Humans , Joint Instability/surgery , Forearm Injuries/surgery , Forearm Injuries/diagnostic imaging , Ligaments, Articular/surgery , Ligaments, Articular/diagnostic imaging , Ligaments, Articular/injuries , Male , Female
3.
Article in English | MEDLINE | ID: mdl-39004116

ABSTRACT

BACKGROUND: O'Driscoll popularized the principle of linked column fixation for distal humerus fractures. Despite the linked column concept being widely accepted, there are few reported techniques to accomplish this goal. A novel device was designed based on the principles of linked columns. An interlocking beam is used to connect the medial and lateral plates, creating a unified fixed angle construct. Our primary objective was to report clinical outcomes across multiple institutions for a linking beam used in distal humerus fracture fixation. METHODS: A retrospective series was collected from five institutions for the TiBeam (Skeletal Dynamics, Miami, FL, USA) with a minimum follow-up of six months. Acute and chronic treatment of distal humerus fracture patterns, and all plate configurations were included for analysis. RESULTS: A total of 36 cases were collected at a mean age of 52 years and a mean follow-up of 19.3 months. AO C-type fractures were 56% of the series. The median MEPS was 85 (IQR 76.3 to 90), the median DASH was 21.4 (IQR 15.9 to 30), and the median VASa was 3.5 (IQR 2 to 5). An olecranon osteotomy was used in 86% of cases and an anatomic plate was used for fixation of the osteotomy in 94% of those cases. There were three cases of olecranon plate removal for a rate across the series of 13.7%. DISCUSSION: Our short-term results demonstrate satisfactory clinical outcomes with low rates of revision for distal humerus fracture fixed with a linking beam. Further, the rate of removal for the olecranon osteotomy plate was lower than historical reports for aggregate methods of osteotomy fixation.

4.
JBJS Case Connect ; 14(2)2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38820195

ABSTRACT

CASE: A 34-year-old man was acutely treated with radial head arthroplasty and central band repair following Essex-Lopresti injury. A 38-year-old man presented with chronic longitudinal instability following failed radial head arthroplasty, which was performed for failed fixation. Treatment with revision radial head arthroplasty and central band reconstruction restored longitudinal stability. CONCLUSION: We have a low threshold to repair the central band in acute Essex-Lopresti injury with sufficient evidence of disruption. Nearly all chronic cases require central band reconstruction to restore longitudinal stability. We do not temporarily pin the DRUJ, and distal ulnar shortening is rarely indicated.


Subject(s)
Joint Instability , Humans , Male , Adult , Joint Instability/surgery , Joint Instability/etiology , Elbow Injuries , Radius Fractures/surgery , Radius Fractures/diagnostic imaging , Wrist Injuries/surgery , Arthroplasty/methods
5.
J Shoulder Elbow Surg ; 33(9): 2033-2038, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38609004

ABSTRACT

BACKGROUND: The incidence of radial head fractures is increasing, and radial head arthroplasty (RHA) is being more frequently used as treatment for irreparable fractures. Our objective was to compare radiocapitellar pressure between the native joint and 2 radial head prosthesis conditions: (1) a prosthetic head that was aligned to the forearm axis of rotation and (2) the same prosthesis with an axisymmetric nonaligned head. METHODS: Ten cadaveric specimens received a pressfit radial head prosthesis (Align; Skeletal Dynamics) for both prosthetic testing conditions. Anatomic alignment (AL) was defined as the prosthetic head aligned to the forearm axis of rotation. Axisymmetric alignment (AX) was defined as the prosthetic radial head aligned to the axis of the prosthetic stem. Axial load was applied with the elbow in extension and the forearm pronated. Data were collected using a Tekscan 4000 sensor. RESULTS: The mean pressure in the AL and AX groups were significantly higher than the mean pressure in the native joint. Compared with the native joint, the mean pressure was 19% higher in the AL group and 56% higher in the AX group. Peak pressure beyond 5 MPa occurred in 0 specimens in the native joint group, in 1 specimen (10%) in the AL group, and in 5 specimens (50%) in the AX group. DISCUSSION: Our results demonstrated that a pressfit radial head prosthesis aligned with the forearm axis of rotation yields capitellar pressures that were more similar to the native condition than a nonaligned pressfit prosthesis. These findings suggest that anatomic alignment may optimize capitellar wear properties, improving the long-term durability of radial head arthroplasty.


Subject(s)
Cadaver , Elbow Joint , Pressure , Radius Fractures , Radius , Humans , Elbow Joint/surgery , Elbow Joint/physiopathology , Radius/surgery , Aged , Radius Fractures/surgery , Arthroplasty, Replacement, Elbow/methods , Male , Female , Elbow Prosthesis , Prosthesis Design , Aged, 80 and over , Middle Aged
6.
J Hand Surg Am ; 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38597836

ABSTRACT

PURPOSE: The distal radioulnar joint (DRUJ) is supported by an array of dynamic and static stabilizers, of which the triangular fibrocartilage complex (TFCC) is the most important, and the distal interosseous ligament is next in importance. The distal oblique band (DOB) is an identifiable component of the distal interosseous ligament, found in a subset of the population. Our objective was to determine the contribution of the DOB to DRUJ stability in the presence of a disrupted TFCC. METHODS: Twenty-three above-elbow specimens were prepared by removing the TFCC and the DRUJ joint capsule, preserving the distal interosseous ligament and the pronator quadratus. Cadavers were stratified into two groups-those with, and those without a DOB. A bone plate and screws were attached to the ulna; then, a transverse load was applied to failure, creating a diastasis between the radius and ulna. RESULTS: The group with a DOB had a mean load at failure of 160.7 ± 46.5 N. The group without a DOB had a mean load at failure of 148.0 ± 26.3 N. Stiffness prior to failure was 16.9 N/mm in the group with a DOB and 12.4 N/mm in the group without a DOB. CONCLUSIONS: The current results indicate that the DOB may not substantially contribute to DRUJ stability in the presence of a disrupted TFCC. CLINICAL RELEVANCE: Stability of the DRUJ after TFCC injury may not be substantially improved by the presence of a DOB. Thus, the clinical importance of DOB reconstruction remains unclear.

7.
J Hand Surg Glob Online ; 6(1): 62-67, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38313626

ABSTRACT

Purpose: The goal of surgical management for unstable elbow injuries is the restoration of joint concentricity and stability. After internal fixation, concerns may exist regarding instability or durability of the fixation construct. Historically, these scenarios were treated with options such as transarticular pinning or external fixation. Recently, an internal joint stabilizer (IJS) that allows postoperative mobilization was introduced. Our objective was to systematically review the literature to aggregate the clinical and biomechanical evidence for the IJS of the elbow. Methods: A systematic review of the PubMed and Google Scholar databases was performed, following the PRISMA guidelines. The search results were narrowed from 2015 through 2023 to coincide with the inception of the device being reviewed. Results: A total of nine retrospective reports on the IJS (N = 171) cases at a mean follow-up of 10.8 months were included. The pooled rate of implant failure was 4.4%, and recurrent instability was 4.1%. Additionally, the we included seven case reports and two biomechanical reports. Conclusions: The aggregate literature describes satisfactory clinical outcomes with low rates of recurrent instability and device failure for the IJS of the elbow. The limited biomechanical investigations conclude efficacy for stability profiles. Clinical relevance: Across a spectrum of unstable elbow cases, the IJS prevented recurrent instability during the early postoperative period. Notably, the device requires an additional procedure for removal, and the long-term impact of the retained devices is currently unclear.

8.
J Hand Surg Eur Vol ; 48(2_suppl): 42S-50S, 2023 09.
Article in English | MEDLINE | ID: mdl-37704027

ABSTRACT

Metacarpal fractures are common and can be functionally disabling. The majority are managed non-operatively. When surgical intervention is indicated, various methods of fixation are available with the utility of each being based on injury pattern, patient function and surgeon preference. Early mobilization, especially in case of open reduction and internal fixation, is a critical component of treatment to prevent stiffness and restore function. When possible, a fixation construct that can withstand the applied forces of early postoperative motion is chosen. We provide an updated description for diagnosis, treatment options and operative fixation for metacarpal fractures.


Subject(s)
Fractures, Bone , Hand Injuries , Metacarpal Bones , Humans , Metacarpal Bones/surgery , Fractures, Bone/surgery , Hand Injuries/surgery , Fracture Fixation, Internal , Open Fracture Reduction
9.
Article in English | MEDLINE | ID: mdl-37747701

ABSTRACT

Recent advancements in surgical treatment have improved clinical results in complex traumatic elbow injury. There is increasing recognition that conservative treatment and inadequate surgical fixation carry high risk of substantial morbidity in many of these cases. Recent literature displays improved outcomes in complex elbow instability, in part, because of a more complete comprehension of the injury patterns and fixation methods. Prompt surgical management with stable internal fixation, which permits immediate postoperative mobilization, has been a consistent variable across the reports leading to more satisfactory outcomes. This applies to both acute and chronic cases.


Subject(s)
Elbow Injuries , Elbow Joint , Joint Dislocations , Joint Instability , Humans , Elbow Joint/surgery , Elbow/surgery , Joint Dislocations/surgery , Joint Dislocations/complications , Joint Instability/surgery , Joint Instability/etiology , Treatment Outcome , Range of Motion, Articular
10.
JSES Rev Rep Tech ; 3(1): 49-55, 2023 Feb.
Article in English | MEDLINE | ID: mdl-37588069

ABSTRACT

Background: Patient age may play a role in the surgeon's decision between radial head arthroplasty (RHA) and open reduction internal fixation in radial head fracture treatment. Though large sample reports have detailed outcomes of radial head replacement for a mean age younger than 50 years, the age ranges are widely distributed. Patient outcomes are not uniform across a broad age distribution. Therefore, treatment decisions should be evaluated within the confines of a narrower age bracket. An understanding of clinical outcomes for radial head replacement in younger adults will provide value for guiding treatment decisions. We performed a systematic review comparing the clinical outcomes for radial head replacement in patients younger and older than 50 years of age. Further analysis compared outcomes between RHA performed as a primary procedure and as a secondary procedure in patients younger and older than 50 years of age. Methods: PubMed was queried for articles which delineated individual patient data for age, surgical treatment, and appropriate outcome metrics. Articles were grouped based on patient age of under 50 and over 50 years and within those age groups, based on the arthroplasty being performed as a primary or as a secondary procedure. Results: There were no significant differences between the under 50 and the over 50 groups for Mayo Elbow Performance Score (P = .79) and for implant revision/removal (P = .32). In the under 50 group, RHA done as a primary procedure had significantly higher (P = .001) mean Mayo Elbow Performance Score than RHA done as a secondary procedure. In the over 50 group, relative risk was 2.39 (95% confidence interval, 2.12-2.69) for implant revision/removal (P = .11) when comparing primary and secondary procedures. Discussion: At a mean follow-up of 48 months, RHA in patients under the age of 50 years had satisfactory outcomes which were comparable to outcomes in patients over the age of 50 years. Across both age groups, arthroplasty performed as a primary procedure demonstrated superior outcomes compared to arthroplasty performed as a secondary procedure. Our findings provide guidance to surgeons who face a multifaceted decision when encountering younger adult patients with radial head fracture patterns that may not be amenable to fixation. Awareness of the age-specific performance of radial head implants is an important component of the decision for surgical treatment.

11.
J Hand Surg Glob Online ; 5(4): 401-406, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37521551

ABSTRACT

Purpose: Kienböck's disease consists of intrinsic and extrinsic characteristics that coalesce into a pathology with multifactorial etiology. Mechanical, morphological, and vascular factors have been identified as contributory. Radial osteotomy is one of the most commonly used surgical treatment for late-stage Kienböck's disease. Despite its frequent use and reported value, the specifics of radial osteotomy have not been described in aggregate. Our objective was to review the recent literature for descriptions of the radial osteotomy techniques used for treatment of Kienböck's disease. Methods: The inclusion criteria for the systematic review were as follows: (1) patients aged >18 years, (2) a publication date no older than 2012, and (3) a complete description of the distal radius osteotomy technique, including verbiage that specified numeric dimensions of bony resection or verbiage that detailed a goal in terms of a radiographic parameter that would guide the bony resection. Results: The studies were grouped according to the stated description of radial osteotomy. This process yielded the following three main groups: (1) studies that used radial shortening, (2) studies that used lateral closing wedge osteotomy or combined lateral closing wedge with radial shortening, and (3) novel osteotomy descriptions. Conclusions: The Kienböck's disease literature predominantly describes an osteotomy to shorten the radius by 2-3 mm. In some studies, the degree of radial shortening corresponded to the value necessary to achieve near-neutral ulnar variance. The common goal in using lateral closing wedge osteotomy was to achieve a radial inclination of 5° to 15°. Unique wedge resections, some with multiplanar corrections, have been recently described with each purporting specific advantages. Clinical relevance: Our findings support the premise of mechanical and biologic efficacy for radial osteotomy, with satisfactory results being reported across a wide spectrum of osteotomy techniques.

12.
Tech Hand Up Extrem Surg ; 27(4): 214-219, 2023 Dec 01.
Article in English | MEDLINE | ID: mdl-37439145

ABSTRACT

We describe a medial approach to the coronoid where the flexor-pronator mass is released from its humeral origin by creating a proximally based tendinous flap. This technique facilitates access to the coronoid, preservation of the medial collateral ligament origin, and repair of the flexor-pronator mass. This approach has utility for all coronoid fracture variations but especially the O'Driscoll anteromedial subtype 3, which includes fractures of the sublime tubercle, the anteromedial facet, and the coronoid tip.


Subject(s)
Elbow Joint , Fractures, Bone , Ulna Fractures , Humans , Ulna Fractures/surgery , Elbow Joint/surgery , Fractures, Bone/surgery , Humerus , Fracture Fixation, Internal/methods
13.
Injury ; 54(10): 110931, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37495450

ABSTRACT

INTRODUCTION: Concerning rates of nonunion in articular distal humerus fractures indicate an unsolved problem. The fixation principles of O'Driscoll describe linking the fractured articular segment to the distal humerus columns with compression screws which creates a stable fixed angle construct. A novel device has been introduced which utilizes an interlocking beam through the articular segment to connect the distal aspect of the medial and lateral plates, creating a linked construct. We sought to evaluate the stability of this linked construct using an articular model of distal humerus fracture. MATERIALS AND METHODS: Ten matched pair specimens of 65 years of age or older were randomized to the use (LB group) or non-use (NLB group) of an interlocking beam to link the medial and lateral locking plates in fixation of an AO Type C3 fracture model. Outside of the linking beam, fixation between the matched pairs was consistent using 2.7 mm locking screws distally with fixed trajectories and +/- 2 mm lengths. RESULTS: Mean stiffness was 273 Newtons/mm in the LB group and 225 Newtons/mm in the NLB group (p = 0.001). Mean maximum displacement was 0.28 in the LB group and 0.93 mm in the NLB group (p = 0.006). Mean load to failure was 277 pounds in the LB group and 280 pounds in the NLB group (p = 0.94). DISCUSSION: Our results indicate that an interlocking beam which links the medial and lateral plates provides greater stability compared to a similar construct without an interlocking beam. We attribute this finding to the beam's double supported design which resists cantilever bending and provides robust compression of the fractured fragments.


Subject(s)
Humeral Fractures, Distal , Intra-Articular Fractures , Humans , Biomechanical Phenomena , Bone Plates , Fracture Fixation , Fracture Fixation, Internal/methods , Humerus , Intra-Articular Fractures/diagnostic imaging , Intra-Articular Fractures/surgery
14.
Hand (N Y) ; : 15589447231151434, 2023 Feb 08.
Article in English | MEDLINE | ID: mdl-36752100

ABSTRACT

BACKGROUND: Revision of radial head arthroplasty (RHA) may be indicated in cases of prosthesis loosening and malposition. Inherent difficulties in revision surgery include poor bone stock and disrupted soft tissue envelope. Although cases of RHA used for revision of failed RHA are rare, there is reasonable expectation for increasing frequency of these cases due to the increasing incidence of primary RHA. Furthermore, there is an increasing demand for postoperative recovery of function; thus, surgeons may consider revising a failed RHA to a new RHA. We report on series of failed RHA which were revised to a new radial head prosthesis. METHODS: A retrospective review was performed at multiple institutions for a single radial head prosthesis used for revision of a failed radial head prosthesis. Clinical and radiographic outcomes were collected with a minimum of 1 year of follow-up. RESULTS: Across 11 patients at a mean follow-up of 45.1 months, the mean Mayo Elbow Performance Score was 81.7; mean Disabilities of the Arm, Shoulder, and Hand scores were 24.4; and mean Visual Analog Scale for pain was 0.6. Radiographic analysis yielded no evidence of capitellar wear or stem loosening. CONCLUSION: A radial head prosthesis can produce satisfactory results when used for revision of a failed prosthesis. Inherent difficulties in revision surgery include the potential for reduced bone stock and a disrupted soft tissue envelope. Elements of prosthesis design which may contribute to effectively managing revision surgery include a long stem with in-growth surface and prosthetic head alignment to the axis of forearm rotation.

15.
Iowa Orthop J ; 43(2): 20-24, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38213861

ABSTRACT

High-energy tibial fractures often present with associated soft tissue injuries, including neuro-vascular damage, complicating the treatment decision. A 33-year-old male presented with Gustilo Anderson type IIIA fracture of the left distal tibia and fibula with associated closed calcaneus fracture and tibial nerve transection. Amputation was discussed, but the decision was made for limb salvage with nerve allograft. The patient displayed satisfactory functional recovery at 29 months postoperatively without need for major revision, grafting, arthrodesis, or amputation. This case report provides an example of successful limb salvage utilizing tibial nerve allograft in a complex high-energy lower extremity injury. Level of Evidence: IV.


Subject(s)
Fractures, Open , Tibial Fractures , Vascular System Injuries , Male , Humans , Adult , Limb Salvage/adverse effects , Tibial Fractures/diagnostic imaging , Tibial Fractures/surgery , Tibia/surgery , Fibula/surgery , Fibula/injuries , Vascular System Injuries/surgery , Amputation, Surgical , Treatment Outcome , Retrospective Studies , Fractures, Open/surgery , Fractures, Open/complications
16.
J Hand Surg Glob Online ; 4(6): 328-331, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36425377

ABSTRACT

Purpose: Distal radius fractures are the most common fractures in adults. Because of the prevalence of these injuries, patients may present with a repeat distal radius fracture on the same wrist through the site of a malunion. We clinically refer to this as an acute on chronic distal radius fracture. In this setting, the restoration of acceptable alignment can be challenging. There is little guidance in the literature for the management of these fractures. We report our experience with acute on chronic distal radius fractures. The secondary fracture plane was used to correct the prior deformity, and the construct was fixated with a fixed angle volar locking plate. Methods: Records of patients with malunion of the distal radius who experienced an acute fracture of the ipsilateral distal radius were reviewed. Inclusion required treatment with open reduction internal fixation using a distal fragment first technique and a volar locking plate through the extended flexor carpi radialis approach. Clinical outcomes and complications were collected. Results: Across 13 patients, the mean follow-up term was 13 months (range, 6-40 months). Radiographic union was noted in all patients. The mean visual analog scale score for pain was 1.8, and the mean Quick Disabilities of the Arm, Shoulder, and Hand score was 21.9. There were no recorded complications. Conclusion: Our results and described technique provide reproducible guidance for the management of acute on chronic distal radius fractures. These cases can be managed using the secondary fracture plane, a distal fragment first technique, and a volar locking plate to correct the preexisting deformity. Type of study/level of evidence: Therapeutic IV.

17.
Hand (N Y) ; : 15589447221122825, 2022 Sep 27.
Article in English | MEDLINE | ID: mdl-36168723

ABSTRACT

BACKGROUND: Distal radius fractures often present with a 3-part articular fragmentation pattern, with separation of the dorsal and volar lunate fossa. The column concept of distal radius fixation addresses the importance of stabilizing both the scaphoid fossa lateral column and the lunate fossa intermediate column. Recent evidence strengthens the value of immediate postoperative mobilization. Satisfactory outcomes following these protocols are predicated on volar locking plates (VLPs) providing adequate stability to the fracture repair. We hypothesize that a VLP which individually supports both lateral and intermediate distal radius columns may provide comparable stability between articular and non-articular cadaveric fracture models under parameters meant to simulate postoperative loading. METHODS: Eleven cadaveric matched pair specimens were randomized to receive a simulated AO Type A2 non-articular distal radius fracture on one side with an AO Type C3 articular fracture on the contralateral side. Stiffness during cyclic loading was compared between fracture groups. A matched-paired Student t-test was used to determine statistical significance (P = .05). RESULTS: There were no significant differences (P = .35) in stiffness between the articular models (mean 370.0 N/mm, +/-93.5) and the non-articular models (360.4 N/mm, +/-60.0) of distal radius fracture. CONCLUSION: A VLP that individually supports the scaphoid and lunate fossa with fixed angle subchondral support may provide comparable fixation strength with resistance to displacement between articular and non-articular fracture patterns. The current results suggest that fossa-specific VLP fixation in articular fractures can maintain construct stability during postoperative loading.

18.
Tech Hand Up Extrem Surg ; 26(4): 257-262, 2022 12 01.
Article in English | MEDLINE | ID: mdl-35698306

ABSTRACT

It is challenging to restore the clinically acceptable alignment of the distal radius after an acute on chronic fracture or after a secondary fracture occurring after malunion of a primary distal radius fracture. In cases of insignificant primary deformity, restoration to the primary deformity may suffice to obtain a successful clinical result. A borderline acceptable primary radial deformity can be unacceptable after the second injury, resulting in functional disability. If surgery is indicated, the surgeon must contend with both primary and secondary deformities to restore proper distal radius anatomy. We present our technique to correct both primary and secondary distal radius deformities through the new or secondary fracture plane.


Subject(s)
Fractures, Malunited , Radius Fractures , Humans , Radius Fractures/complications , Radius Fractures/surgery , Wrist Joint , Radius/surgery , Fractures, Malunited/surgery , Treatment Outcome
19.
Semin Musculoskelet Radiol ; 26(3): 295-313, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35654096

ABSTRACT

Common indications for surgical procedures of the wrist and hand include acute fractures or fracture-dislocations; nonunited fractures; posttraumatic, degenerative, and inflammatory arthritides and tendinopathies; injuries to tendons, ligaments, and the triangular fibrocartilage complex; and entrapment neuropathies. Soft tissue or osseous infections or masses may also need surgical treatment. Several of these procedures require surgical hardware placement, and most entail clinical follow-up with periodic imaging. Radiography should be the first imaging modality in the evaluation of the postoperative wrist and hand. Computed tomography, magnetic resonance imaging, diagnostic ultrasonography, and occasionally nuclear medicine studies may be performed to diagnose or better characterize suspected postoperative complications. To provide adequate evaluation of postoperative imaging of the wrist and hand, the interpreting radiologist must be familiar with the basic principles of these surgical procedures and both the imaging appearance of normal postoperative findings as well as the potential complications.


Subject(s)
Triangular Fibrocartilage , Wrist Injuries , Hand , Humans , Wrist/diagnostic imaging , Wrist/surgery , Wrist Injuries/diagnostic imaging , Wrist Injuries/surgery , Wrist Joint/diagnostic imaging , Wrist Joint/surgery
20.
Tech Hand Up Extrem Surg ; 26(4): 214-217, 2022 12 01.
Article in English | MEDLINE | ID: mdl-35383724

ABSTRACT

A variety of fixation options exist for treatment of unstable proximal phalanx fractures. Variables which require consideration include the strength of fixation, the invasiveness of the technique and the postoperative rehabilitation protocol. Here we present a minimally invasive technique for dual headless compression screw fixation of proximal phalanx fractures which reduces extensor tendon violation and allows early motion in the immediate postoperative period.


Subject(s)
Finger Phalanges , Fractures, Bone , Humans , Finger Phalanges/surgery , Range of Motion, Articular , Bone Screws , Fractures, Bone/surgery , Tendons , Fracture Fixation, Internal/methods
SELECTION OF CITATIONS