1.
Sci Rep ; 14(1): 10781, 2024 05 11.
Article En | MEDLINE | ID: mdl-38734781

Magnetic resonance (MR) acquisitions of the torso are frequently affected by respiratory motion with detrimental effects on signal quality. The motion of organs inside the body is typically decoupled from surface motion and is best captured using rapid MR imaging (MRI). We propose a pipeline for prospective motion correction of the target organ using MR image navigators providing absolute motion estimates in millimeters. Our method is designed to feature multi-nuclear interleaving for non-proton MR acquisitions and to tolerate local transmit coils with inhomogeneous field and sensitivity distributions. OpenCV object tracking was introduced for rapid estimation of in-plane displacements in 2D MR images. A full three-dimensional translation vector was derived by combining displacements from slices of multiple and arbitrary orientations. The pipeline was implemented on 3 T and 7 T MR scanners and tested in phantoms and volunteers. Fast motion handling was achieved with low-resolution 2D MR image navigators and direct implementation of OpenCV into the MR scanner's reconstruction pipeline. Motion-phantom measurements demonstrate high tracking precision and accuracy with minor processing latency. The feasibility of the pipeline for reliable in-vivo motion extraction was shown on heart and kidney data. Organ motion was manually assessed by independent operators to quantify tracking performance. Object tracking performed convincingly on 7774 navigator images from phantom scans and different organs in volunteers. In particular the kernelized correlation filter (KCF) achieved similar accuracy (74%) as scored from inter-operator comparison (82%) while processing at a rate of over 100 frames per second. We conclude that fast 2D MR navigator images and computer vision object tracking can be used for accurate and rapid prospective motion correction. This and the modular structure of the pipeline allows for the proposed method to be used in imaging of moving organs and in challenging applications like cardiac magnetic resonance spectroscopy (MRS) or magnetic resonance imaging (MRI) guided radiotherapy.


Phantoms, Imaging , Humans , Magnetic Resonance Spectroscopy/methods , Magnetic Resonance Imaging/methods , Respiration , Image Processing, Computer-Assisted/methods , Motion , Movement , Algorithms
2.
Front Physiol ; 15: 1327407, 2024.
Article En | MEDLINE | ID: mdl-38384795

Introduction: Magnetic resonance elastography (MRE) is a non-invasive method to quantify biomechanical properties of human tissues. It has potential in diagnosis and monitoring of kidney disease, if established in clinical practice. The interplay of flow and volume changes in renal vessels, tubule, urinary collection system and interstitium is complex, but physiological ranges of in vivo viscoelastic properties during fasting and hydration have never been investigated in all gross anatomical segments simultaneously. Method: Ten healthy volunteers underwent two imaging sessions, one following a 12-hour fasting period and the second after a drinking challenge of >10 mL per kg body weight (60-75 min before the second examination). High-resolution renal MRE was performed using a novel driver with rotating eccentric mass placed at the posterior-lateral wall to couple waves (50 Hz) to the kidney. The biomechanical parameters, shear wave speed (cs in m/s), storage modulus (Gd in kPa), loss modulus (Gl in kPa), phase angle (Υ=2πatanGlGd) and attenuation (α in 1/mm) were derived. Accurate separation of gross anatomical segments was applied in post-processing (whole kidney, cortex, medulla, sinus, vessel). Results: High-quality shear waves coupled into all gross anatomical segments of the kidney (mean shear wave displacement: 163 ± 47 µm, mean contamination of second upper harmonics <23%, curl/divergence: 4.3 ± 0.8). Regardless of the hydration state, median Gd of the cortex and medulla (0.68 ± 0.11 kPa) was significantly higher than that of the sinus and vessels (0.48 ± 0.06 kPa), and consistently, significant differences were found in cs, Υ, and Gl (all p < 0.001). The viscoelastic parameters of cortex and medulla were not significantly different. After hydration sinus exhibited a small but significant reduction in median Gd by -0.02 ± 0.04 kPa (p = 0.01), and, consequently, the cortico-sinusoidal-difference in Gd increased by 0.04 ± 0.07 kPa (p = 0.05). Only upon hydration, the attenuation in vessels became lower (0.084 ± 0.013 1/mm) and differed significantly from the whole kidney (0.095 ± 0.007 1/mm, p = 0.01). Conclusion: High-resolution renal MRE with an innovative driver and well-defined 3D segmentation can resolve all renal segments, especially when including the sinus in the analysis. Even after a prolonged hydration period the approach is sensitive to small hydration-related changes in the sinus and in the cortico-sinusoidal-difference.

3.
Sci Rep ; 14(1): 3254, 2024 02 08.
Article En | MEDLINE | ID: mdl-38332163

Acetylcarnitine is an essential metabolite for maintaining metabolic flexibility and glucose homeostasis. The in vivo behavior of muscle acetylcarnitine content during exercise has not been shown with magnetic resonance spectroscopy. Therefore, this study aimed to explore the behavior of skeletal muscle acetylcarnitine during rest, plantar flexion exercise, and recovery in the human gastrocnemius muscle under aerobic conditions. Ten lean volunteers and nine overweight volunteers participated in the study. A 7 T whole-body MR system with a double-tuned surface coil was used to acquire spectra from the gastrocnemius medialis. An MR-compatible ergometer was used for the plantar flexion exercise. Semi-LASER-localized 1H MR spectra and slab-localized 31P MR spectra were acquired simultaneously in one interleaved exercise/recovery session. The time-resolved interleaved 1H/31P MRS acquisition yielded excellent data quality. A between-group difference in acetylcarnitine metabolism over time was detected. Significantly slower τPCr recovery, τPCr on-kinetics, and lower Qmax in the overweight group, compared to the lean group was found. Linear relations between τPCr on-kinetics, τPCr recovery, VO2max and acetylcarnitine content were identified. In conclusion, we are the first to show in vivo changes of skeletal muscle acetylcarnitine during acute exercise and immediate exercise recovery with a submaximal aerobic workload using interleaved 1H/31P MRS at 7 T.


Acetylcarnitine , Overweight , Humans , Acetylcarnitine/metabolism , Phosphocreatine/metabolism , Overweight/metabolism , Exercise/physiology , Muscle, Skeletal/metabolism
4.
Magn Reson Med ; 88(1): 309-321, 2022 07.
Article En | MEDLINE | ID: mdl-35373857

PURPOSE: To evaluate the feasibility of motion correction for sodium (23 Na) MRI based on interleaved acquired 3D proton (1 H) navigator images. METHODS: A 3D radial density-adapted sequence for interleaved 23 Na/1 H MRI was implemented on a 7 Tesla whole-body MRI system. The 1 H data obtained during the 23 Na acquisition were used to reconstruct 140 navigator image volumes with a nominal spatial resolution of (2.5 mm)3 and a temporal resolution of 6 s. The motion information received from co-registration was then used to correct the 23 Na image dataset, which also had a nominal spatial resolution of (2.5 mm)3 . The approach was evaluated on six healthy volunteers, whose motion during the scans had different intensities and characteristics. RESULTS: Interleaved acquisition of two nuclei did not show any relevant influence on image quality (SNR of 13.0 for interleaved versus 13.2 for standard 23 Na MRI and 176.4 for interleaved versus 178.0 for standard 1 H MRI). The applied motion correction increased the consistency between two consecutive scans for all examined volunteers and improved the image quality for all kinds of motion. The SD of the differences ranged between 2.30% and 6.96% for the uncorrected and between 2.13% and 2.67% for the corrected images. CONCLUSION: The feasibility of interleaved acquired 1 H navigator images to be used for retrospective motion correction of 23 Na images was successfully demonstrated. The approach neither affected the 23 Na image quality nor elongated the scan time and can therefore be an important tool to improve the accuracy of quantitative 23 Na MRI.


Magnetic Resonance Imaging , Protons , Brain/diagnostic imaging , Humans , Image Processing, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Motion , Retrospective Studies , Sodium
5.
NMR Biomed ; 35(10): e4735, 2022 10.
Article En | MEDLINE | ID: mdl-35352440

Magnetic resonance signals from different nuclei can be excited or received at the same time,rendering simultaneous or rapidly interleaved multi-nuclear acquisitions feasible. The advan-tages are a reduction of total scan time compared to sequential multi-nuclear acquisitions or that additional information from heteronuclear data is obtained at thesame time and anatomical position. Information content can be qualitatively increased by delivering a more comprehensive MR-based picture of a transient state (such as an exercise bout). Also, combiningnon-proton MR acquisitions with 1 Hinformation (e.g., dynamic shim updates and motion correction) can be used to improve data quality during long scans and benefits image coregistration. This work reviews the literature on interleaved and simultaneous multi-nuclear MRI and MRS in vivo. Prominent use cases for this methodology in clinical and research applications are brain and muscle, but studies have also been carried out in other targets, including the lung, knee, breast and heart. Simultaneous multi-nuclear measurements in the liver and kidney have also been performed, but exclusively in rodents. In this review, a consistent nomenclature is proposed, to help clarify the terminology used for this principle throughout the literature on in-vivo MR. An overview covers the basic principles, the technical requirements on the MR scanner and the implementations realised either by MR system vendors or research groups, from the early days until today. Considerations regarding the multi-tuned RF coils required and heteronuclear polarisation interactions are briefly discussed, and fields for future in-vivo applications for interleaved multi-nuclear MR pulse sequences are identified.


Brain , Magnetic Resonance Imaging , Brain/diagnostic imaging , Magnetic Resonance Imaging/methods , Magnetic Resonance Spectroscopy , Motion , Radio Waves
6.
Magn Reson Med ; 87(3): 1174-1183, 2022 03.
Article En | MEDLINE | ID: mdl-34719061

PURPOSE: Lactate is a key metabolite in skeletal muscle and whole-body physiology. Its MR visibility in muscle is affected by overlapping lipid signals and fiber orientation. Double-quantum filtered (DQF) 1 H MRS selectively detects lactate at 1.3 ppm, but at ultra-high field the efficiency of slice-selective 3D-localization with conventional RF pulses is limited by bandwidth. This novel 3D-localized 1 H DQF MRS sequence uses adiabatic refocusing pulses to unambiguously detect lactate in skeletal muscle at 7 T. METHODS: Lactate double-quantum coherences were 3D-localized using slice-selective Shinnar-Le Roux optimized excitation and adiabatic refocusing pulses (similar to semi-LASER). DQF MR spectra were acquired at 7 T from lactate phantoms, meat specimens with injected lactate (exploring multiple TEs and fiber orientations), and human gastrocnemius in vivo during and after exercise (without cuff ischemia). RESULTS: Lactate was readily detected, achieving the full potential of 50% signal with a DQF, in solution. The effects of fiber orientation and TE on the lactate doublet (peak splitting, amplitude, and phase) were in good agreement with theory and literature. Exercise-induced lactate accumulation was detected with 30 s time resolution. CONCLUSION: This novel 3D-localized 1 H DQF MRS sequence can dynamically detect glycolytically generated lactate in muscle during exercise and recovery at 7 T.


Lactic Acid , Muscle, Skeletal , Exercise , Humans , Magnetic Resonance Spectroscopy , Muscle, Skeletal/diagnostic imaging , Phantoms, Imaging
7.
Sci Rep ; 11(1): 9268, 2021 04 29.
Article En | MEDLINE | ID: mdl-33927234

The heart's geometry and its metabolic activity vary over the cardiac cycle. The effect of these fluctuations on phosphorus (31P) magnetic resonance spectroscopy (MRS) data quality and metabolite ratios was investigated. 12 healthy volunteers were measured using a 7 T MR scanner and a cardiac 31P-1H loop coil. 31P chemical shift imaging data were acquired untriggered and at four different times during the cardiac cycle using acoustic triggering. Signals of adenosine-triphosphate (ATP), phosphocreatine (PCr), inorganic phosphate (Pi) and 2,3-diphosphoglycerate (2,3-DPG) and their fit quality as Cramér-Rao lower bounds (CRLB) were quantified including corrections for contamination by 31P signals from blood, flip angle, saturation and total acquisition time. The myocardial filling factor was estimated from cine short axis views. The corrected signals of PCr and [Formula: see text]-ATP were higher during end-systole and lower during diastasis than in untriggered acquisitions ([Formula: see text]). Signal intensities of untriggered scans were between those with triggering to end-systole and diastasis. Fit quality of PCr and [Formula: see text]-ATP peaks was best during end-systole when blood contamination of ATP and Pi signals was lowest. While metabolite ratios and pH remained stable over the cardiac cycle, signal amplitudes correlated strongly with myocardial voxel filling. Triggering of cardiac 31P MRS acquisitions improves signal amplitudes and fit quality if the trigger delay is set to end-systole. We conclude that triggering to end-systole is superior to triggering to diastasis.


Adenosine Triphosphate/metabolism , Heart/physiology , Magnetic Resonance Imaging/methods , Magnetic Resonance Spectroscopy/methods , Myocardium/metabolism , Phosphorus/analysis , Adult , Female , Humans , Male , Young Adult
8.
EJNMMI Phys ; 8(1): 18, 2021 Feb 18.
Article En | MEDLINE | ID: mdl-33599876

BACKGROUND: PET/MRI phantom studies are challenged by the need of phantom-specific attenuation templates to account for attenuation properties of the phantom material. We present a PET/MRI phantom built from MRI-visible material for which attenuation correction (AC) can be performed using the standard MRI-based AC. METHODS: A water-fillable phantom was 3D-printed with a commercially available MRI-visible polymer. The phantom had a cylindrical shape and the fillable compartment consisted of a homogeneous region and a region containing solid rods of different diameters. The phantom was filled with a solution of water and [18F]FDG. A 30 min PET/MRI acquisition including the standard Dixon-based MR-AC method was performed. In addition, a CT scan of the phantom was acquired on a PET/CT system. From the Dixon in-phase, opposed-phase and fat images, a phantom-specific AC map (Phantom MR-AC) was produced by separating the phantom material from the water compartment using a thresholding-based method and assigning fixed attenuation coefficients to the individual compartments. The PET data was reconstructed using the Phantom MR-AC, the original Dixon MR-AC, and an MR-AC just containing the water compartment (NoWall-AC) to estimate the error of ignoring the phantom walls. CT-based AC was employed as the reference standard. Average %-differences in measured activity between the CT corrected PET and the PET corrected with the other AC methods were calculated. RESULTS: The phantom housing and the liquid compartment were both visible and distinguishable from each other in the Dixon images and allowed the segmentation of a phantom-specific MR-based AC. Compared to the CT-AC PET, average differences in measured activity in the whole water compartment in the phantom of -0.3%, 9.4%, and -24.1% were found for Dixon phantom MR-AC, MR-AC, and NoWall-AC based PET, respectively. Average differences near the phantom wall in the homogeneous region were -0.3%, 6.6%, and -34.3%, respectively. Around the rods, activity differed from the CT-AC PET by 0.7%, 8.9%, and -45.5%, respectively. CONCLUSION: The presented phantom material is visible using standard MR sequences, and thus, supports the use of standard, phantom-independent MR measurements for MR-AC in PET/MRI phantom studies.

9.
Magn Reson Med ; 86(1): 115-130, 2021 07.
Article En | MEDLINE | ID: mdl-33565187

PURPOSE: To evaluate the repeatability of multinuclear interleaved 1 H/31 P NMR dynamic acquisitions in skeletal muscle and the impact of nuclear Overhauser enhancement (nOe) on the 31 P results at 3T in exercise-recovery and ischemia-hyperemia paradigms. METHODS: A 1 H/31 P interleaved pulse sequence was used to measure every 2.5 s a perfusion-weighted image, a T2∗ map, a 31 P spectrum and 32 1 H spectra sensitive to deoxymyoglobin. 21 subjects performed a plantar flexion exercise and after recovery underwent an 8-min lower leg ischemia. The procedure was repeated in visit 2 with 12 subjects. An additional exercise bout without 1 H excitation was appended to visit 1. Individual 1 H RF pulse nOe was measured at rest in every visit. RESULTS: Repeatability scores (coefficient of variation, Bland-Altman analysis) were similar to those found in the literature using similar mono-nuclear acquisitions. |Pi]/[PCr], pH drop, creatine rephosphorylation rate (τPCr ), maximum perfusion, time to peak perfusion, and blood flow post-exercise showed high reliability (intraclass correlation coefficient > 0.7), whereas hemodynamic results from reactive hyperemia showed higher repeatability. After accounting for nOe, which increased Pi and PCr signal-to-noise ratio by 30%, no differences in 31 P results were observed between interleaved and 31 P MRS-only acquisitions. τPCr was unaffected by nOe. CONCLUSION: The method shows good repeatability for both paradigms while simultaneously providing multiple dynamic data sets on a clinical scanner. The nOe effects were accounted for on a per-subject and per-visit basis using a short 31 P reference scan. This multiparametric approach has a multitude of applications for the study of oxygen utilization and ATP turnover in the muscle.


Leg , Muscle, Skeletal , Exercise , Humans , Leg/diagnostic imaging , Magnetic Resonance Spectroscopy , Muscle, Skeletal/diagnostic imaging , Reproducibility of Results
10.
NMR Biomed ; 34(5): e4484, 2021 05.
Article En | MEDLINE | ID: mdl-33559967

The translation of MRS to clinical practice has been impeded by the lack of technical standardization. There are multiple methods of acquisition, post-processing, and analysis whose details greatly impact the interpretation of the results. These details are often not fully reported, making it difficult to assess MRS studies on a standardized basis. This hampers the reviewing of manuscripts, limits the reproducibility of study results, and complicates meta-analysis of the literature. In this paper a consensus group of MRS experts provides minimum guidelines for the reporting of MRS methods and results, including the standardized description of MRS hardware, data acquisition, analysis, and quality assessment. This consensus statement describes each of these requirements in detail and includes a checklist to assist authors and journal reviewers and to provide a practical way for journal editors to ensure that MRS studies are reported in full.


Consensus , Magnetic Resonance Spectroscopy , Research Report/standards , Expert Testimony , Humans , Software
11.
NMR Biomed ; : e4347, 2020 Aug 17.
Article En | MEDLINE | ID: mdl-32808407

With a 40-year history of use for in vivo studies, the terminology used to describe the methodology and results of magnetic resonance spectroscopy (MRS) has grown substantially and is not consistent in many aspects. Given the platform offered by this special issue on advanced MRS methodology, the authors decided to describe many of the implicated terms, to pinpoint differences in their meanings and to suggest specific uses or definitions. This work covers terms used to describe all aspects of MRS, starting from the description of the MR signal and its theoretical basis to acquisition methods, processing and to quantification procedures, as well as terms involved in describing results, for example, those used with regard to aspects of quality, reproducibility or indications of error. The descriptions of the meanings of such terms emerge from the descriptions of the basic concepts involved in MRS methods and examinations. This paper also includes specific suggestions for future use of terms where multiple conventions have emerged or coexisted in the past.

12.
NMR Biomed ; : e4246, 2020 Feb 10.
Article En | MEDLINE | ID: mdl-32037688

Skeletal muscle phosphorus-31 31 P MRS is the oldest MRS methodology to be applied to in vivo metabolic research. The technical requirements of 31 P MRS in skeletal muscle depend on the research question, and to assess those questions requires understanding both the relevant muscle physiology, and how 31 P MRS methods can probe it. Here we consider basic signal-acquisition parameters related to radio frequency excitation, TR, TE, spectral resolution, shim and localisation. We make specific recommendations for studies of resting and exercising muscle, including magnetisation transfer, and for data processing. We summarise the metabolic information that can be quantitatively assessed with 31 P MRS, either measured directly or derived by calculations that depend on particular metabolic models, and we give advice on potential problems of interpretation. We give expected values and tolerable ranges for some measured quantities, and minimum requirements for reporting acquisition parameters and experimental results in publications. Reliable examination depends on a reproducible setup, standardised preconditioning of the subject, and careful control of potential difficulties, and we summarise some important considerations and potential confounders. Our recommendations include the quantification and standardisation of contraction intensity, and how best to account for heterogeneous muscle recruitment. We highlight some pitfalls in the assessment of mitochondrial function by analysis of phosphocreatine (PCr) recovery kinetics. Finally, we outline how complementary techniques (near-infrared spectroscopy, arterial spin labelling, BOLD and various other MRI and 1 H MRS measurements) can help in the physiological/metabolic interpretation of 31 P MRS studies by providing information about blood flow and oxygen delivery/utilisation. Our recommendations will assist in achieving the fullest possible reliable picture of muscle physiology and pathophysiology.

13.
Magn Reson Med ; 83(6): 1909-1919, 2020 06.
Article En | MEDLINE | ID: mdl-31846116

PURPOSE: MR offers the unique possibility to noninvasively investigate cellular energy metabolism via 31P MRS, while blood perfusion, which provides oxygen and substrates to the tissue, is accessible by arterial spin labeling (ASL) 1H MRI. Because metabolic and hemodynamic parameters are linked, it would be desirable to study them simultaneously. A 3D-resolved method is presented that allows such measurements with high spatiotemporal resolution and has the potential to discern differences along an exercising muscle. METHODS: Multi-voxel localized 31 P MRS was temporally interleaved with multi-slice pASL 1H MRI. Phosphorus spectra were collected from two adjacent positions in gastrocnemius medialis (GM) during rest, submaximal plantar flexion exercise and recovery, while perfusion and T2* -weighted axial images were acquired at the same time. Seventeen healthy volunteers (9 f / 8 m) were studied at 7 T. RESULTS: An increase of postexercise perfusion and T2* -weighted signal in GM positively correlated with end-exercise PCr depletion and pH drop. At proximal positions functional and metabolic activity was higher than distally, that is, perfusion increase and peak T2* -weighted signal, end-exercise PCr depletion, end-exercise pH, and PCr recovery time constant were significantly different. An NOE-induced SNR increase of approximately 20 % (P < .001), at rest, was found in interleaved 31 P spectra, when comparing to 31 P-only acquisitions. CONCLUSIONS: A technique for fast, simultaneous imaging of muscle functional heterogeneity in ASL, T2* and acquisition of time-resolved 31 P  MRS data is presented. These single exercise recovery experiments can be used to investigate local variations during disease progression in patients suffering from vascular or muscular diseases.


Leg , Muscle, Skeletal , Exercise , Humans , Leg/diagnostic imaging , Magnetic Resonance Imaging , Muscle, Skeletal/diagnostic imaging , Phosphocreatine
14.
Prog Nucl Magn Reson Spectrosc ; 109: 1-50, 2018 12.
Article En | MEDLINE | ID: mdl-30527132

Magnetic resonance imaging and spectroscopic techniques are widely used in humans both for clinical diagnostic applications and in basic research areas such as cognitive neuroimaging. In recent years, new human MR systems have become available operating at static magnetic fields of 7 T or higher (≥300 MHz proton frequency). Imaging human-sized objects at such high frequencies presents several challenges including non-uniform radiofrequency fields, enhanced susceptibility artifacts, and higher radiofrequency energy deposition in the tissue. On the other side of the scale are gains in signal-to-noise or contrast-to-noise ratio that allow finer structures to be visualized and smaller physiological effects to be detected. This review presents an overview of some of the latest methodological developments in human ultra-high field MRI/MRS as well as associated clinical and scientific applications. Emphasis is given to techniques that particularly benefit from the changing physical characteristics at high magnetic fields, including susceptibility-weighted imaging and phase-contrast techniques, imaging with X-nuclei, MR spectroscopy, CEST imaging, as well as functional MRI. In addition, more general methodological developments such as parallel transmission and motion correction will be discussed that are required to leverage the full potential of higher magnetic fields, and an overview of relevant physiological considerations of human high magnetic field exposure is provided.


Magnetic Resonance Imaging/methods , Magnetic Resonance Spectroscopy/methods , Neuroimaging/methods , Humans
15.
Sci Rep ; 8(1): 6211, 2018 04 18.
Article En | MEDLINE | ID: mdl-29670177

13C magnetic resonance spectroscopy is a viable, non-invasive method to study cell metabolism in skeletal muscles. However, MR sensitivity of 13C is inherently low, which can be overcome by applying a higher static magnetic field strength together with radiofrequency coil arrays instead of single loop coils or large volume coils, and 1H decoupling, which leads to a simplified spectral pattern. 1H-decoupled 13C-MRS requires RF coils which support both, 1H and 13C, Larmor frequencies with sufficient electromagnetic isolation between the pathways of the two frequencies. We present the development, evaluation, and first in vivo measurement with a 7 T 3-channel 13C and 4-channel 1H transceiver array optimized for 1H-decoupled 13C-MRS in the posterior human calf muscles. To ensure minimal cross-coupling between 13C and 1H arrays, several strategies were combined: mutual magnetic flux was minimized by coil geometry, two LCC traps were inserted into each 13C element, and band-pass and low-pass filters were integrated along the signal pathways. The developed coil array was successfully tested in phantom and in vivo MR experiments, showing a simplified spectral pattern and increase in signal-to-noise ratio of approximately a factor 2 between non-decoupled and 1H-decoupled spectra in a glucose phantom and the human calf muscle.


Carbon-13 Magnetic Resonance Spectroscopy , Muscle, Skeletal/chemistry , Proton Magnetic Resonance Spectroscopy , Radio Waves , Carbon-13 Magnetic Resonance Spectroscopy/methods , Electromagnetic Fields , Electromagnetic Phenomena , Glycogen/analysis , Glycogen/chemistry , Humans , Phantoms, Imaging , Proton Magnetic Resonance Spectroscopy/methods
16.
NMR Biomed ; 31(6): e3905, 2018 06.
Article En | MEDLINE | ID: mdl-29578260

Exercise studies investigating the metabolic response of calf muscles using 31 P MRS are usually performed with a single knee angle. However, during natural movement, the distribution of workload between the main contributors to force, gastrocnemius and soleus is influenced by the knee angle. Hence, it is of interest to measure the respective metabolic response of these muscles to exercise as a function of knee angle using localized spectroscopy. Time-resolved multivoxel 31 P MRS at 7 T was performed simultaneously in gastrocnemius medialis and soleus during rest, plantar flexion exercise and recovery in 12 healthy volunteers. This experiment was conducted with four different knee angles. PCr depletions correlated negatively with knee angle in gastrocnemius medialis, decreasing from 79±14 % (extended leg) to 35±23 %(∼40°), and positively in soleus, increasing from 20±21 % to 36±25 %; differences were significant. Linear correlations were found between knee angle and end-exercise PCr depletions in gastrocnemius medialis (R2 =0.8) and soleus (R2 =0.53). PCr recovery times and end-exercise pH changes that correlated with PCr depletion were consistent with the literature in gastrocnemius medialis and differences between knee angles were significant. These effects were less pronounced in soleus and not significant for comparable PCr depletions. Maximum oxidative capacity calculated for all knee angles was in excellent agreement with the literature and showed no significant changes between different knee angles. In conclusion, these findings confirm that plantar flexion exercise with a straight leg is a suitable paradigm, when data are acquired from gastrocnemius only (using either localized MRS or small surface coils), and that activation of soleus requires the knee to be flexed. The present study comprises a systematic investigation of the effects of the knee angle on metabolic parameters, measured with dynamic multivoxel 31 P MRS during muscle exercise and recovery, and the findings should be used in future study design.


Exercise/physiology , Knee Joint/physiology , Magnetic Resonance Spectroscopy , Phosphorus/chemistry , Range of Motion, Articular/physiology , Adult , Female , Humans , Hydrogen-Ion Concentration , Linear Models , Male , Oxidation-Reduction , Phosphocreatine/metabolism
17.
Magn Reson Med ; 77(3): 921-927, 2017 03.
Article En | MEDLINE | ID: mdl-26914656

PURPOSE: Separate measurements are required when investigating multiple exercising muscles with singlevoxel-localized dynamic 31 P-MRS. With multivoxel spectroscopy, 31 P-MRS time-series spectra are acquired from multiple independent regions during one exercise-recovery experiment with the same time resolution as for singlevoxel measurements. METHODS: Multiple independently selected volumes were localized using temporally interleaved semi-LASER excitations at 7T. Signal loss caused by mutual saturation from shared excitation or refocusing slices was quantified at partial and full overlap, and potential contamination was investigated in phantom measurements. During an exercise-recovery experiment both gastrocnemius medialis and soleus of two healthy volunteers were measured using multivoxel acquisitions with a total TR of 6 s, while avoiding overlap of excitation slices. RESULTS: Signal reduction by shared adiabatic refocusing slices selected 1 s after the preceding voxel was between 10% (full overlap) and 20% (half overlap), in a phantom measurement. In vivo data were acquired from both muscles within the same exercise experiment, with 13-18% signal reduction. Spectra show phosphocreatine, inorganic phosphate, adenosine-triposphate, phosphomonoesters, and phosphodiesters. CONCLUSION: Signal decrease was relatively low compared to the 2-fold increase in information. The approach could help to improve the understanding in metabolic research and is applicable to other organs and nuclei. Magn Reson Med 77:921-927, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.


Algorithms , Exercise/physiology , Magnetic Resonance Spectroscopy/methods , Muscle, Skeletal/physiology , Phosphorus Compounds/metabolism , Phosphorus Isotopes/pharmacokinetics , Female , Humans , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Male , Molecular Imaging/methods , Radiopharmaceuticals/pharmacokinetics , Reproducibility of Results , Sensitivity and Specificity
18.
NMR Biomed ; 29(12): 1825-1834, 2016 12.
Article En | MEDLINE | ID: mdl-27862510

Phosphorus MRSI (31 P-MRSI) using a spiral-trajectory readout at 7 T was developed for high temporal resolution mapping of the mitochondrial capacity of exercising human skeletal muscle. The sensitivity and localization accuracy of the method was investigated in phantoms. In vivo performance was assessed in 12 volunteers, who performed a plantar flexion exercise inside a whole-body 7 T MR scanner using an MR-compatible ergometer and a surface coil. In five volunteers the knee was flexed (~60°) to shift the major workload from the gastrocnemii to the soleus muscle. Spiral-encoded MRSI provided 16-25 times faster mapping with a better point spread function than elliptical phase-encoded MRSI with the same matrix size. The inevitable trade-off for the increased temporal resolution was a reduced signal-to-noise ratio, but this was acceptable. The phosphocreatine (PCr) depletion caused by exercise at 0° knee angulation was significantly higher in both gastrocnemii than in the soleus (i.e. 64.8 ± 19.6% and 65.9 ± 23.6% in gastrocnemius lateralis and medialis versus 15.3 ± 8.4% in the soleus). Spiral-encoded 31 P-MRSI is a powerful tool for dynamic mapping of exercising muscle oxidative metabolism, including localized assessment of PCr concentrations, pH and maximal oxidative flux with high temporal and spatial resolution.


Energy Metabolism/physiology , Exercise/physiology , Magnetic Resonance Spectroscopy/methods , Mitochondria, Muscle/physiology , Molecular Imaging/methods , Muscle, Skeletal/physiology , Phosphocreatine/metabolism , Adult , Exercise Tolerance/physiology , Female , Humans , Magnetic Resonance Imaging/methods , Male , Mitochondria, Muscle/ultrastructure , Muscle, Skeletal/diagnostic imaging , Phosphorus Isotopes/pharmacokinetics , Radiopharmaceuticals/pharmacokinetics , Range of Motion, Articular , Reproducibility of Results , Sensitivity and Specificity
19.
Sci Rep ; 6: 32037, 2016 08 26.
Article En | MEDLINE | ID: mdl-27562396

(31)P magnetic resonance spectroscopy (MRS) is widely used for non-invasive investigation of muscle metabolism dynamics. This study aims to extend knowledge on parameters derived from these measurements in detail and comprehensiveness: proton (H(+)) efflux, buffer capacity and the contributions of glycolytic (L) and oxidative (Q) rates to ATP synthesis were calculated from the evolutions of phosphocreatine (PCr) and pH. Data are reported for two muscles in the human calf, for each subject and over a wide range of exercise intensities. 22 subjects performed plantar flexions in a 7T MR-scanner, leading to PCr changes ranging from barely noticeable to almost complete depletion, depending on exercise protocol and muscle studied by localized MRS. Cytosolic buffer capacity was quantified for the first time non-invasively and individually, as was proton efflux evolution in early recovery. Acidification started once PCr depletion reached 60-75%. Initial and end-exercise L correlated with end-exercise levels of PCr and approximately linear with pH. Q calculated directly from PCr and pH derivatives was plausible, requiring fewer assumptions than the commonly used ADP-model. In conclusion, the evolution of parameters describing cellular energy metabolism was measured over a wide range of exercise intensities, revealing a relatively complete picture of muscle metabolism.


Adenosine Triphosphate/metabolism , Exercise/physiology , Magnetic Resonance Spectroscopy/methods , Muscle, Skeletal/metabolism , Protons , Female , Humans , Male
20.
Magn Reson Med ; 76(5): 1636-1641, 2016 11.
Article En | MEDLINE | ID: mdl-26608834

PURPOSE: Modification of a clinical MRI scanner to enable simultaneous or rapid interleaved acquisition of signals from two different nuclei. METHODS: A device was developed to modify the local oscillator signal fed to the receive channel(s) of an MRI console. This enables external modification of the frequency at which the receiver is sensitive and rapid switching between different frequencies. Use of the device was demonstrated with interleaved and simultaneous 31 P and 1 H spectroscopic acquisitions, and with interleaved 31 P and 1 H imaging. RESULTS: Signal amplitudes and signal-to-noise ratios were found to be unchanged for the modified system, compared with data acquired with the MRI system in the standard configuration. CONCLUSION: Interleaved and simultaneous 1 H and 31 P signal acquisition was successfully demonstrated with a clinical MRI scanner, with only minor modification of the RF architecture. While demonstrated with 31 P, the modification is applicable to any detectable nucleus without further modification, enabling a wide range of simultaneous and interleaved experiments to be performed within a clinical setting. Magn Reson Med 76:1636-1641, 2016. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.


Carbon-13 Magnetic Resonance Spectroscopy/instrumentation , Magnetic Resonance Imaging/instrumentation , Molecular Imaging/instrumentation , Phosphorus Isotopes/pharmacokinetics , Computer-Aided Design , Equipment Design , Equipment Failure Analysis , Reproducibility of Results , Sensitivity and Specificity , Systems Integration
...