Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Mol Cancer Ther ; 23(6): 877-889, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38593239

ABSTRACT

Head and neck cancer radiotherapy often damages salivary glands and oral mucosa, severely negatively impacting patients' quality of life. The ability of FLASH proton radiotherapy (F-PRT) to decrease normal tissue toxicity while maintaining tumor control compared with standard proton radiotherapy (S-PRT) has been previously demonstrated for several tissues. However, its potential in ameliorating radiation-induced salivary gland dysfunction and oral mucositis and controlling orthotopic head and neck tumor growth has not been reported. The head and neck area of C57BL/6 mice was irradiated with a single dose of radiotherapy (ranging from 14-18 Gy) or a fractionated dose of 8 Gy × 3 of F-PRT (128 Gy/second) or S-PRT (0.95 Gy/second). Following irradiation, the mice were studied for radiation-induced xerostomia by measuring their salivary flow. Oral mucositis was analyzed by histopathologic examination. To determine the ability of F-PRT to control orthotopic head and neck tumors, tongue tumors were generated in the mice and then irradiated with either F-PRT or S-PRT. Mice treated with either a single dose or fractionated dose of F-PRT showed significantly improved survival than those irradiated with S-PRT. F-PRT-treated mice showed improvement in their salivary flow. S-PRT-irradiated mice demonstrated increased fibrosis in their tongue epithelium. F-PRT significantly increased the overall survival of the mice with orthotopic tumors compared with the S-PRT-treated mice. The demonstration that F-PRT decreases radiation-induced normal tissue toxicity without compromising tumor control, suggests that this modality could be useful for the clinical management of patients with head and neck cancer.


Subject(s)
Disease Models, Animal , Head and Neck Neoplasms , Proton Therapy , Salivary Glands , Stomatitis , Animals , Mice , Stomatitis/etiology , Head and Neck Neoplasms/radiotherapy , Salivary Glands/radiation effects , Salivary Glands/pathology , Proton Therapy/methods , Humans , Cell Line, Tumor , Mice, Inbred C57BL , Xerostomia/etiology , Female
2.
Med Phys ; 2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38597815

ABSTRACT

BACKGROUND: Cyclotron-based proton therapy systems utilize the highest proton energies to achieve an ultra-high dose rate (UHDR) for FLASH radiotherapy. The deep-penetrating range associated with this high energy can be modulated by inserting a uniform plate of proton-stopping material, known as a range shifter, in the beam path at the nozzle to bring the Bragg peak within the target while ensuring high proton transport efficiency for UHDR. Aluminum has been recently proposed as a range shifter material mainly due to its high compactness and its mechanical properties. A possible drawback lies in the fact that aluminum has a larger cross-section of producing secondary neutrons compared to conventional plastic range shifters. Accordingly, an increase in secondary neutron contamination was expected during the delivery of range-modulated FLASH proton therapy, potentially heightening neutron-induced carcinogenic risks to the patient. PURPOSE: We conducted neutron dosimetry using simulations and measurements to evaluate excess dose due to neutron exposure during UHDR proton irradiation with aluminum range shifters compared to plastic range shifters. METHODS: Monte Carlo simulations in TOPAS were performed to investigate the secondary neutron production characteristics with aluminum range shifter during 225 MeV single-spot proton irradiation. The computational results were validated against measurements with a pair of ionization chambers in an out-of-field region ( ≤ $\le$ 30 cm) and with a Proton Recoil Scintillator-Los Alamos rem meter in a far-out-of-field region (0.5-2.5 m). The assessments were repeated with solid water slabs as a surrogate for the conventional range shifter material to evaluate the impact of aluminum on neutron yield. The results were compared with the International Electrotechnical Commission (IEC) standards to evaluate the clinical acceptance of the secondary neutron yield. RESULTS: For a range modulation up to 26 cm in water, the maximum simulated and measured values of out-of-field secondary neutron dose equivalent per therapeutic dose with aluminum range shifter were found to be ( 0.57 ± 0.02 ) mSv/Gy $(0.57\pm 0.02)\ \text{mSv/Gy}$ and ( 0.46 ± 0.04 ) mSv/Gy $(0.46\pm 0.04)\ \text{mSv/Gy}$ , respectively, overall higher than the solid water cases (simulation: ( 0.332 ± 0.003 ) mSv/Gy $(0.332\pm 0.003)\ \text{mSv/Gy}$ ; measurement: ( 0.33 ± 0.03 ) mSv/Gy $(0.33\pm 0.03)\ \text{mSv/Gy}$ ). The maximum far out-of-field secondary neutron dose equivalent was found to be ( 8.8 ± 0.5 $8.8 \pm 0.5$ )  µ Sv / Gy $\umu {\rm Sv/Gy}$ and ( 1.62 ± 0.02 $1.62 \pm 0.02$ )  µ Sv / Gy $\umu {\rm Sv/Gy}$ for the simulations and rem meter measurements, respectively, also higher than the solid water counterparts (simulation: ( 3.3 ± 0.3 $3.3 \pm 0.3$ )  µ Sv / Gy $\umu {\rm Sv/Gy}$ ; measurement: ( 0.63 ± 0.03 $0.63 \pm 0.03$ )  µ Sv / Gy $\umu {\rm Sv/Gy}$ ). CONCLUSIONS: We conducted simulations and measurements of secondary neutron production under proton irradiation at FLASH energy with range shifters. We found that the secondary neutron yield increased when using aluminum range shifters compared to conventional materials while remaining well below the non-primary radiation limit constrained by the IEC regulations.

3.
Int J Radiat Oncol Biol Phys ; 119(4): 1234-1247, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-38364948

ABSTRACT

PURPOSE: Studies during the past 9 years suggest that delivering radiation at dose rates exceeding 40 Gy/s, known as "FLASH" radiation therapy, enhances the therapeutic index of radiation therapy (RT) by decreasing normal tissue damage while maintaining tumor response compared with conventional (or standard) RT. This study demonstrates the cardioprotective benefits of FLASH proton RT (F-PRT) compared with standard (conventional) proton RT (S-PRT), as evidenced by reduced acute and chronic cardiac toxicities. METHODS AND MATERIALS: Mice were imaged using cone beam computed tomography to precisely determine the heart's apex as the beam isocenter. Irradiation was conducted using a shoot-through technique with a 5-mm diameter circular collimator. Bulk RNA-sequencing was performed on nonirradiated samples, as well as apexes treated with F-PRT or S-PRT, at 2 weeks after a single 40 Gy dose. Inflammatory responses were assessed through multiplex cytokine/chemokine microbead assay and immunofluorescence analyses. Levels of perivascular fibrosis were quantified using Masson's Trichrome and Picrosirius red staining. Additionally, cardiac tissue functionality was evaluated by 2-dimensional echocardiograms at 8- and 30-weeks post-PRT. RESULTS: Radiation damage was specifically localized to the heart's apex. RNA profiling of cardiac tissues treated with PRT revealed that S-PRT uniquely upregulated pathways associated with DNA damage response, induction of tumor necrosis factor superfamily, and inflammatory response, and F-PRT primarily affected cytoplasmic translation, mitochondrion organization, and adenosine triphosphate synthesis. Notably, F-PRT led to a milder inflammatory response, accompanied by significantly attenuated changes in transforming growth factor ß1 and α smooth muscle actin levels. Critically, F-PRT decreased collagen deposition and better preserved cardiac functionality compared with S-PRT. CONCLUSIONS: This study demonstrated that F-PRT reduces the induction of an inflammatory environment with lower expression of inflammatory cytokines and profibrotic factors. Importantly, the results indicate that F-PRT better preserves cardiac functionality, as confirmed by echocardiography analysis, while also mitigating the development of long-term fibrosis.


Subject(s)
Fibrosis , Heart Diseases , Inflammation , Proton Therapy , Animals , Proton Therapy/adverse effects , Mice , Inflammation/etiology , Inflammation/radiotherapy , Heart Diseases/etiology , Heart Diseases/prevention & control , Heart Diseases/diagnostic imaging , Heart Diseases/radiotherapy , Heart/radiation effects , Disease Models, Animal , Mice, Inbred C57BL , Radiation Injuries, Experimental/metabolism , Radiation Injuries, Experimental/prevention & control , Radiation Injuries, Experimental/pathology , Male , Radiation Injuries/prevention & control
SELECTION OF CITATIONS
SEARCH DETAIL
...