Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
1.
Rheumatol Int ; 43(4): 721-733, 2023 04.
Article in English | MEDLINE | ID: mdl-36163594

ABSTRACT

OBJECTIVE: Perspectives of women aged 18-45 years with chronic rheumatic diseases (CRD), and clinicians, in the Asia-Pacific (APAC) region are reported. METHODS: Online surveys were completed by women, pregnant in the past 2-5 years, with moderate to severe rheumatoid arthritis (RA), psoriatic arthritis (PsA), axial spondyloarthritis (axSpA), and rheumatologists, obstetricians, orthopaedic surgeons who medically manage CRDs. RESULTS: Among 210 (RA 122, PsA 48, axSpA 40) patients, 52% (n = 109/210) delayed their decision to have children, most commonly due to concerns of passing on disease to offspring. 33% (n = 70/210) discussed family planning with a healthcare professional at diagnosis. Patients most often initiated discussions. 94% (n = 193/205) stopped treatment around pregnancy due to fear of fetal harm. 66% (n = 139/210) of patients felt they did not receive all relevant information on the impact of CRDs and treatment on pregnancy. Among 335 clinicians who participated, 82% (n = 143/174) of rheumatologists, 86% (n = 72/84) of obstetricians and 43% (n = 33/77) of orthopaedic surgeons agreed good disease control during pregnancy was their primary goal. 69% (n = 120/174) of rheumatologists were 'very comfortable' with prescribing tumour necrosis factor inhibitors (TNFi) for women aged 18-45 years. Comfort levels generally decreased with the onset of family planning. More obstetricians and orthopaedic surgeons supported avoiding TNFi during pregnancy than rheumatologists (40% [n = 34/84]/38% [n = 29/77] versus 16% [n = 28/174]). Access to more TNFi safety data during pregnancy was considered paramount for increasing clinician comfort. CONCLUSIONS: Patients and physicians need current information and multidisciplinary discussions for improved management of CRD in women in APAC.


Subject(s)
Arthritis, Psoriatic , Arthritis, Rheumatoid , Child , Humans , Female , Pregnancy , Adolescent , Young Adult , Adult , Middle Aged , Arthritis, Rheumatoid/diagnosis , Surveys and Questionnaires , Chronic Disease , Tumor Necrosis Factor Inhibitors , Asia/epidemiology
2.
J Manag Care Spec Pharm ; 27(7): 936-947, 2021 Jul.
Article in English | MEDLINE | ID: mdl-34185553

ABSTRACT

BACKGROUND: Inclusion of patient experience (PEx) in health technology assessment (HTA) has become increasingly important; however, no harmonized approach exists to help manufacturers or decision makers ensure PEx considerations are fair, consistent, and thorough within global HTA frameworks. OBJECTIVE: To develop a proposal for including PEx in the HTA frameworks of health technologies. METHODS: A systematic literature review (SLR) on existing value frameworks (VFs) was conducted to capture how PEx-related value judgment is currently considered. Guided by the results of the SLR, a research group including HTA experts and patient representatives used an iterative process to develop potential value domains to capture PEx, in accordance with international guidelines. Subsequently, a panel of international payer experts was used to challenge the proposed PEx domains and provide recommendations for implementation. RESULTS: The SLR found 61 VFs and multi-criteria decision analyses (MCDAs) that considered PEx; however, PEx-related value elements were often referred to superficially, without clear definitions. Five potential PEx domains, with proposed measures for each, were developed and refined using expert feedback: (1) responsiveness to patient's individual needs, (2) improved health literacy and empowerment, (3) patient and caregiver reported outcomes, (4) household's financial burden, and (5) improved access for vulnerable patient populations. A flexible approach for framework implementation was proposed. CONCLUSIONS: Proposed PEx domains could be implemented at multiple levels of healthcare decision making to formalize consideration of PEx in the assessment of value, either through the extension of existing VFs or to create new PEx-focused VFs and more holistic decision making tools. DISCLOSURES: This study was funded and sponsored by UCB Pharma. The funding agreement ensured the authors' independence in designing the study, interpreting the data, writing, and publishing the report. Charokopou, Mountain, and Szegvari are employed by UCB Pharma. Inotai, Jakab, and Kalo are employed by Syreon Research Institute, which received funding from UCB Pharma for this research. Brixner has received fees from AbbVie, Elevar, Millcreek Outcomes Group, Novartis, Sanofi, UCB Pharma, and Xcenda. Campbell has received grants and contracts from the PhRMA Foundation and the Institute for Clinical and Economic Review. During a sabbatical leave, Campbell collaborated with Syreon Research Institute on research projects that included funding from UCB Pharma. Hawkins has received consultancy fees from UCB Pharma. Kristensen has received speakers bureau fees from Pfizer, AbbVie, Amgen, UCB Pharma, Celgene, Bristol-Myers Squibb, MSD, Novartis, Eli Lilly, and Janssen Pharmaceuticals and consultancy fees from UCB Pharma.


Subject(s)
Biomedical Technology , Patient Outcome Assessment , Patient Satisfaction , Data Collection , Humans
4.
Health Qual Life Outcomes ; 18(1): 355, 2020 Nov 04.
Article in English | MEDLINE | ID: mdl-33148261

ABSTRACT

BACKGROUND: Patient-reported outcome (PRO) instruments provide robust and effective means of evaluating patients' treatment experience; however, none adequately cover experience using self-injection devices with enhanced features, such as an electromechanical autoinjector (e-Device). The aim of this study was to develop a PRO instrument that accurately assesses patient experience of using an e-Device and to evaluate its psychometric properties. METHODS: A mixed-methods approach was taken; two parallel, targeted literature reviews were conducted to identify relevant concepts and existing self-injection PRO instruments that could be adapted. Patient feedback obtained from two focus groups was used to inform initial instrument development. The pilot instrument was then administered in a multicenter, open-label, phase 3 clinical study in which patients self-injected certolizumab pegol using an e-Device, to gather evidence of its psychometric qualities. Exit interviews were conducted with a sub-sample of patients enrolled in the study to confirm the appropriateness and clarity of the items included and cognitively debrief the instrument. Confirmatory factor analysis (CFA) was conducted on all items, and each domain's internal consistency was measured using Cronbach's ɑ. RESULTS: The literature searches identified several e-Device-specific concepts related to device features, device function, side effects/reactions/pain, confidence, and interference/convenience in daily life. Seven existing PRO instruments were identified. The Self-Injection Assessment Questionnaire (SIAQ), containing pre- and post-injection questionnaire modules, was selected as most suitable and adapted using feedback from 19 patients in the two focus groups to form the pilot Assessment of Self-Injection (ASI) questionnaire. CFA resulted in some changes to the grouping of items in the post-injection module domains following psychometric evaluation of the ASI. Internal consistency was satisfactory for all pre- and post-injection domains (ɑ > 0.8). Cognitive debriefing results from 12 patient exit interviews confirmed the ASI's appropriateness and clarity. CONCLUSIONS: The ASI was developed iteratively with patient input and was evaluated in its intended clinical context of use. Psychometric analyses indicated promising cross-sectional results; the ASI was well understood and considered relevant by patients self-injecting using the e-Device, suggesting that it could be used in real-world settings to aid with clinical decision making. TRIAL REGISTRATION: NCT03357471.


Subject(s)
Injections/instrumentation , Patient Reported Outcome Measures , Self Administration/instrumentation , Adult , Clinical Trials, Phase III as Topic , Female , Focus Groups , Humans , Injections/psychology , Male , Middle Aged , Multicenter Studies as Topic , Pilot Projects , Psychometrics/methods , Qualitative Research , Reproducibility of Results , Self Administration/psychology
5.
JMIR Form Res ; 4(7): e17373, 2020 Jul 27.
Article in English | MEDLINE | ID: mdl-32716310

ABSTRACT

BACKGROUND: Certolizumab pegol (CZP) is an anti-tumor necrosis factor drug approved for the treatment of multiple moderate to severe chronic inflammatory diseases. In the European Union, CZP is approved for administration by subcutaneous self-injection using a prefilled syringe, prefilled pen, or reusable electromechanical auto-injector (electronic device). CimplyMe is a companion app for use alongside CZP self-injection devices, designed to support CZP-treated patients self-managing their treatment and disease. OBJECTIVE: This study aimed to validate the usability of the companion app by demonstrating that tasks required for use can be performed successfully by intended end users. METHODS: We recruited 15 patients with moderate to severe rheumatoid arthritis, currently prescribed biologic treatment, and using apps on a smart phone. Patients were assessed on their ability to use the companion app in a setting designed to simulate a location where patients regularly administer biologic treatment. To assess the usability of the key features of the app, 8 critical and 3 noncritical tasks were designed. Patients' success on each task was recorded through observations or knowledge-based questions. Successes with difficulty and use errors were also recorded. If a patient made a use error at the first attempt, a second attempt was allowed. Second-attempt use errors were recorded as a task failure. RESULTS: A total of 207 first attempts at the 14 components of the 8 critical tasks were evaluated (3 patients failed to complete one component); 178 (86.0%) critical tasks were successfully completed at the first attempt. The remaining first attempts comprised 16 (7.7%) successes with difficulty and 13 (6.3%) use errors, which had to be repeated. One critical task was not re-attempted by one patient due to time constraints; however, there were no use errors in the 12 completed second attempts. A total of 107 first attempts at the 3 noncritical tasks were made, all of which (107/107, 100.0%) were completed without use errors. CONCLUSIONS: In simulated testing, patients were able to successfully use the companion app without formal training. This study suggests the companion app is easy to use and could help patients prescribed CZP better manage their treatment and disease.

6.
Expert Opin Drug Deliv ; 17(6): 855-862, 2020 06.
Article in English | MEDLINE | ID: mdl-32239971

ABSTRACT

BACKGROUND: ava® is a new reusable electromechanical auto-injector (e-Device) with disposable, single-use certolizumab pegol (CZP) dispensing cartridges. METHODS: RA0098 (NCT03357471) was a US, multicenter, open-label, phase 3 study designed to assess whether the e-Device can be used safely and effectively by self-injecting patients. CZP pre-filled syringe (PFS) self-injecting patients (≥18 years) diagnosed with rheumatoid arthritis, axial spondyloarthritis, psoriatic arthritis, plaque psoriasis, and Crohn's disease received training and self-injected CZP using the e-Device at 2 visits. The primary outcome was the proportion of patients able to self-inject safely and effectively at Visit 2, defined as: 1) complete dose delivery, and 2) no adverse events related to the e-Device precluding its continued use. RESULTS: 65/67 patients (97.0%) completed the study, 64/65 (98.5%) performed safe and effective self-injection at Visit 2, and 67/67 (100%) performed safe and effective self-injection at Visit 1. Patient satisfaction and self-confidence increased over the two visits. Overall, patients reported a preference for the e-Device (58/65; 89.2%) compared to a PFS (4/65; 6.2%). CONCLUSIONS: Patients were able to safely and effectively self-inject CZP using the e-Device and most preferred ava® over a PFS. No safety-related findings impacting the benefit-risk ratio of CZP were identified.


Subject(s)
Antirheumatic Agents/administration & dosage , Certolizumab Pegol/administration & dosage , Patient Satisfaction , Adult , Aged , Arthritis, Psoriatic/drug therapy , Arthritis, Rheumatoid/drug therapy , Female , Humans , Injections , Male , Middle Aged , Psoriasis/drug therapy , Treatment Outcome
7.
Expert Opin Drug Deliv ; 17(5): 705-711, 2020 05.
Article in English | MEDLINE | ID: mdl-32154740

ABSTRACT

Background: Anti-tumor necrosis factor (anti-TNF) adherence is suboptimal. ava®, a reusable electromechanical self-injection device (e-Device) developed for certolizumab pegol (CZP) administration, aims to overcome some barriers to increase adherence. This study evaluates patient experience of the e-Device and its training materials and determines patient device preference.Methods: CZP-treated patients were recruited from the Netherlands, Denmark and Sweden. Patients completed a pre-injection Assessment of Self-Injection (ASI) questionnaire investigating self-injection perception. After training, patients administered 3 consecutive self-injections using the e-Device, patient experience of each was assessed using the post-injection ASI. An additional questionnaire evaluated training materials. After Injection 3, patients indicated their preference: the e-Device or their previous device.Results: 59 patients participated; most rated the e-Device highly for satisfaction, self-confidence and ease of use. The (negative) feelings and pain and skin reactions domains had low ratings. Post-injection ASI domain scores were similar following each of the 3 e-Device injections. Training materials were rated highly (video: 8.4/10; step-by-step guide: 8.4/10). 57.1% (32/56) patients preferred the e-Device over their previous self-injection device.Conclusions: Patients were satisfied with the e-Device and most preferred it over other self-injection devices. By improving patient experience, the e-Device may help increase medication adherence.


Subject(s)
Antirheumatic Agents/administration & dosage , Certolizumab Pegol/administration & dosage , Patient Satisfaction , Adult , Aged , Electronics , Female , Humans , Injections , Male , Middle Aged , Patient Preference , Pilot Projects , Surveys and Questionnaires , Treatment Outcome , Tumor Necrosis Factor-alpha/antagonists & inhibitors
8.
Adv Ther ; 37(4): 1522-1535, 2020 04.
Article in English | MEDLINE | ID: mdl-32124272

ABSTRACT

INTRODUCTION: The CIMZIA® AutoClicks® pre-filled pen (CZP PFP) was developed to overcome barriers to self-injection, by improving self-injection confidence, reducing fear associated with needle use, and supporting patients with impaired dexterity. The purpose of this research was to gather feedback on injection experience and the usefulness of training materials. METHODS: Eligible patients with rheumatoid arthritis (RA), axial spondyloarthritis (axSpA) or psoriatic arthritis (PsA) were at least 18 years of age and initiated onto the CZP PFP. Routine self-injection training and support were provided by trained specialist nurses. Patient experience (pain and skin reactions, confidence, satisfaction, and ease of use) was evaluated at visits 1-3 using an amended version of the self-injection assessment questionnaire (SIAQ) v2.0. Nurse and patient feedback on the training materials, and nurse opinions on patient self-injection after self-injection at visit 1, were also collected. RESULTS: Of 355 patients invited to participate, 196 provided informed consent and 79 participated in all three visits. Patients generally found the CZP PFP easy to use, and self-confidence and satisfaction were high. From visit 1 to visit 3, there was a numerical trend towards improvement in all three aspects of patient experience, most notably in both confidence and satisfaction. After self-injection at visit 1, confidence around safe patient self-injection was higher among nurses than among patients. Meanwhile, "pain and skin reactions" remained low at all visits. Patients thought the training materials contained sufficient information and were easy to understand and useful. CONCLUSION: After training, patients generally found the device easy to use and showed high confidence and satisfaction with self-injection. Some patients may have been competent (based on nurse opinion), but initially lacked self-confidence. Increasing self-injection experience, together with patient training and continued support, may have facilitated high patient confidence and satisfaction, thereby potentially overcoming some of the barriers to self-injection.


Subject(s)
Antirheumatic Agents/administration & dosage , Arthritis, Psoriatic/drug therapy , Arthritis, Rheumatoid/drug therapy , Certolizumab Pegol/administration & dosage , Patient Satisfaction , Spondylarthritis/drug therapy , Spondylarthritis/psychology , Adolescent , Adult , Antirheumatic Agents/therapeutic use , Arthritis, Psoriatic/psychology , Arthritis, Rheumatoid/psychology , Certolizumab Pegol/therapeutic use , Female , Humans , Injections , Male , Middle Aged , Self Administration , Surveys and Questionnaires , United Kingdom
9.
Patient Prefer Adherence ; 13: 1093-1110, 2019.
Article in English | MEDLINE | ID: mdl-31371927

ABSTRACT

PURPOSE: To quantify rheumatology patient preferences and willingness to pay (WTP) for features differentiating enhanced from standard self-injection devices and to investigate differences among subgroups. PATIENTS AND METHODS: Patients with rheumatoid arthritis (RA), psoriatic arthritis (PsA), and axial spondyloarthritis (axSpA) were recruited in the UK. A discrete-choice experiment was used to elicit preferences; respondents were presented with 10 choices between 3 different devices: a free standard disposable device, and 2 hypothetical reusable devices characterized by presence/absence of skin sensor, injection speed control, on-screen instructions, injection reminders, electronic log, and large grip. Every hypothetical device included a cost component to assess WTP for each enhanced feature. A random-parameters logit model was used to estimate preference weights and WTP. RESULTS: Data were collected from 323 respondents by electronic survey (15/11/2017-15/02/2018; RA: 108; PsA: 103; axSpA: 112). On average, the skin sensor was the most preferred feature (£30), followed by injection speed control, injection reminders, electronic log (~£20 each), on-screen instructions (~£12), and a device with a small, rather than large grip (~£7). Similar preferences for attributes were observed across condition subgroups except for grip size: axSpA patients preferred small grip (~£27); PsA patients preferred large grip (~£19). Overall, respondents preferred reusable devices with all enhanced features (WTP value: £85) over the standard device. RA patients exhibited a higher WTP (£145) than PsA (£102) or axSpA (£62) for the same enhanced device. CONCLUSION: Patients positively valued reusable self-injection devices with enhanced features, which may improve patient experience, potentially improving treatment adherence, clinical, and economic outcomes.

10.
Drug Deliv ; 26(1): 384-392, 2019 Dec.
Article in English | MEDLINE | ID: mdl-30905213

ABSTRACT

Biologic drugs (e.g. anti-tumor necrosis factors) are effective treatments for multiple chronic inflammatory diseases including rheumatoid arthritis, axial spondyloarthritis, and psoriatic arthritis. Administration of biologic drugs is usually via subcutaneous self-injection, which provides many patient benefits compared to infusions including increased flexibility, reduced costs, and reduced caregiver burden. However, it is also associated with challenges such as needle phobia, patient treatment misconceptions and incorrect drug administration, and can be impacted by dexterity problems. Evidence suggests these problems, along with other drug administration challenges (e.g. patient forgetfulness, busy lifestyles, and polypharmacy), can reduce patient adherence to treatment. To combat these challenges, patient feedback has been used to develop a range of self-injection devices, including pre-filled syringes, pre-filled pens, and electronic injection devices. Providing different devices for drug administration gives patients the opportunity to choose a device that addresses the challenges they face as an individual. Research suggests involving patients in medical device development, providing patients with a choice of devices and enrolling individuals in patient support programs can empower patients to take control of their treatment journey. By providing a portfolio of self-injection devices, designed based on patient needs, patient experience will improve, potentially improving adherence and hence, long-term treatment outcomes.


Subject(s)
Antirheumatic Agents/administration & dosage , Biological Products/administration & dosage , Rheumatic Diseases/drug therapy , Animals , Equipment Design , Humans , Injections, Subcutaneous , Medication Adherence , Self Administration , Syringes
11.
Adv Ther ; 35(9): 1333-1355, 2018 09.
Article in English | MEDLINE | ID: mdl-30078176

ABSTRACT

Chronic inflammatory diseases (CIDs) represent a substantial clinical and economic burden to patients, providers, payers and society overall. Biologics, such as tumor necrosis factor inhibitors (TNFi), have emerged as effective treatment options for patients with CIDs. However, the therapeutic potential of biologics is not always achieved in clinical practice, with results from studies examining the use of biologics in real-world settings suggesting lower levels of treatment effectiveness compared with clinical trial results. Using a targeted approach, this literature review demonstrates that compliance and persistence with biologic therapy is suboptimal and that this has implications for both clinical outcomes and treatment costs. The review identified a variety of predictors of treatment compliance and persistence, including increased age, female gender, presence of comorbidities, increased disease activity, longer disease duration, smoking, increased body mass index, higher biologic treatment dose, higher treatment cost and lower health-related quality-of-life scores. Patients often cited factors associated with medication delivery as a reason for non-compliance and non-persistence, and device-related improvements to treatment delivery were associated with higher rates of compliance and persistence. The articles identified in this review provide insights that have the potential to help guide the development of new solutions to improve disease management and optimize treatment regimens. This has the potential to benefit patients' health by improving clinical outcomes and to reduce the burden to society by limiting the economic impact of patients' disease. FUNDING: UCB Pharma.


Subject(s)
Autoimmune Diseases/drug therapy , Biological Products/therapeutic use , Biological Therapy/methods , Medication Adherence/statistics & numerical data , Age Factors , Biological Products/administration & dosage , Biological Products/adverse effects , Body Mass Index , Comorbidity , Health Expenditures , Humans , Quality of Life , Retrospective Studies , Risk Factors , Sex Factors , Smoking/epidemiology , Time Factors , Treatment Outcome , Tumor Necrosis Factor-alpha/antagonists & inhibitors
12.
Patient ; 11(5): 515-526, 2018 10.
Article in English | MEDLINE | ID: mdl-29948962

ABSTRACT

BACKGROUND AND OBJECTIVE: Qualitative methods such as semi-structured interviews and focus-groups are used to evaluate the applicability and relevance of device technologies in clinical practice, but when used alone, often lack generalizability. This study aimed to assess the face validity and feasibility of using a composite, three-step qualitative method (the Parker Model), to inform the development and implementation of ava®, an electromechanical device (e-Device) for subcutaneous self-administration of the biologic, certolizumab pegol (CZP), used to treat rheumatic diseases. METHODS: The Parker Model combines concept mapping (CM), participatory design (PD), and stakeholder evaluation (SE). CM, a structured group process, was used to identify patients' opinions and concerns regarding the e-Device. Patients used this information in iterative PD sessions to create personal e-Device prototypes in cooperation with a designer and a healthcare professional. SE was performed based on semi-structured group and individual interviews with patients and disease-management stakeholders. RESULTS: The study recruited 14 patients, two doctors, two nurses, one medical secretary, and four other public servants. Three CM workshops revealed four key considerations: technical usability, physical design, concerns, and enthusiasm. Four personalized prototypes were developed during PD sessions. SE confirmed that the identified considerations were pivotal for the implementation and adaptation of the e-Device. CONCLUSIONS: This study is the first to apply a composite, qualitative research model when introducing an e-Device for the treatment and management of rheumatic disease. Results show that input from patients and other stakeholders using the Parker Model can add value to the development and implementation of an e-Device.


Subject(s)
Antirheumatic Agents/administration & dosage , Certolizumab Pegol/administration & dosage , Chronic Disease/drug therapy , Inventions/statistics & numerical data , Rheumatic Diseases/drug therapy , Therapies, Investigational/instrumentation , Therapies, Investigational/methods , Adult , Aged , Aged, 80 and over , Antirheumatic Agents/therapeutic use , Certolizumab Pegol/therapeutic use , Denmark , Female , Focus Groups , Humans , Male , Middle Aged , Qualitative Research
13.
Adv Ther ; 35(1): 100-115, 2018 01.
Article in English | MEDLINE | ID: mdl-29222625

ABSTRACT

INTRODUCTION: We incorporated patient feedback from human factors studies (HFS) in the patient-centric design and validation of ava®, an electromechanical device (e-Device) for self-injecting the anti-tumor necrosis factor certolizumab pegol (CZP). METHODS: Healthcare professionals, caregivers, healthy volunteers, and patients with rheumatoid arthritis, psoriatic arthritis, ankylosing spondylitis, or Crohn's disease participated in 11 formative HFS to optimize the e-Device design through intended user feedback; nine studies involved simulated injections. Formative participant questionnaire feedback was collected following e-Device prototype handling. Validation HFS (one EU study and one US study) assessed the safe and effective setup and use of the e-Device using 22 predefined critical tasks. Task outcomes were categorized as "failures" if participants did not succeed within three attempts. RESULTS: Two hundred eighty-three participants entered formative (163) and validation (120) HFS; 260 participants performed one or more simulated e-Device self-injections. Design changes following formative HFS included alterations to buttons and the graphical user interface screen. All validation HFS participants completed critical tasks necessary for CZP dose delivery, with minimal critical task failures (12 of 572 critical tasks, 2.1%, in the EU study, and 2 of 5310 critical tasks, less than 0.1%, in the US study). CONCLUSION: CZP e-Device development was guided by intended user feedback through HFS, ensuring the final design addressed patients' needs. In both validation studies, participants successfully performed all critical tasks, demonstrating safe and effective e-Device self-injections. FUNDING: UCB Pharma. Plain language summary available on the journal website.


Subject(s)
Antirheumatic Agents/administration & dosage , Arthritis/drug therapy , Certolizumab Pegol/administration & dosage , Crohn Disease/drug therapy , Equipment Design/methods , Adult , Aged , Antirheumatic Agents/therapeutic use , Arthritis, Psoriatic/drug therapy , Arthritis, Rheumatoid/drug therapy , Certolizumab Pegol/therapeutic use , Female , Humans , Injections, Subcutaneous , Male , Middle Aged , Spondylitis, Ankylosing/drug therapy , Tumor Necrosis Factor-alpha/antagonists & inhibitors
14.
Rheumatol Ther ; 4(2): 445-463, 2017 Dec.
Article in English | MEDLINE | ID: mdl-28956300

ABSTRACT

INTRODUCTION: Drug administration by self-injection provides an option to treat chronic inflammatory diseases such as rheumatoid arthritis (RA) and Crohn's disease (CD). However, a negative self-injection experience for patients may reduce patient adherence to the recommended treatment regimen. In this study, a holistic approach was used to identify common themes along the treatment pathway and at self-injection that, if changed, could improve patient experience and treatment outcomes. METHODS: Two ethnographic studies were conducted: Field Insights CODE (FI[CODE]) examined the treatment pathway within the context of the experience of living with RA or CD, and Injection Mission 2020 (IM2020) focused on the moment of self-injection. FI(CODE) used an open ethnographic approach to interview 62 patients and 10 healthcare professionals (HCPs) from the US and UK. IM2020 included a review of over 50 injection device design information sources from the sponsor, and interviews with 9 patients, 8 HCPs, and 5 medical device designers from the US, UK, Canada, and Japan. RESULTS: FI(CODE) identified suboptimal treatment practices along the treatment pathway in four key areas: treatment team communication, treatment choice, patient empowerment, and treatment delivery. Patients with more treatment options and greater disease understanding were less likely to struggle with the treatment process. IM2020 demonstrated that five related components influenced the self-injection experience: delivery process, emotional state, social perception, educational level, and ritualization of the self-injection process. CONCLUSION: These analyses highlight several potential areas for improvement, including aligning the device more to patients' needs to improve treatment adherence, better accessibility to educational resources to increase patient disease understanding, and guidance to empower patients to develop an optimal personalized self-injection ritual. FUNDING: UCB Pharma.


Some medicines used to treat long-term conditions, such as rheumatoid arthritis or Crohn's disease, are injected under the skin. Often, patients can choose to inject medicines themselves (self-injection). This must be done correctly for the medicines to work properly. But, the training surrounding self-injection is uneven and often cannot address the fundamental problems facing all self-injecting patients.What healthcare improvements could help patients self-inject successfully? To find out, we interviewed people living with rheumatoid arthritis or Crohn's disease, while others were doctors, nurses, and people who design injection devices.We found four common problems in the overall healthcare that patients received:1.There were communication problems between different healthcare professionals and between healthcare professionals and patients, for example about treatment options or goals.2.Each level in the healthcare system (e.g., the nurse, doctor, hospital board, health insurance company) made decisions that limited how many treatment options were presented to patients for consideration.3.Patients were not empowered, as they felt they lacked personal input, information, and control in treatment decisions.4.Healthcare professionals focused on disease treatment but not patient experience; they did not fully explain how to perform injections (delivery), leaving patients to figure it out by trial and error. In addition, five factors were identified that affected patients' experiences of self-injection:1.Process of injection: minimal one-on-one instruction for self-injection left some patients anxious and more prone to mistakes.2.Emotions: some patients were better than others at 'overriding' emotions (e.g., fear) when self-injecting.3.Views on injections: there was negative social stigma around injections, but patients had greater trust in more technological, modern devices.4.Education: doctors often failed to explain how to manage fear and anxiety.5.Developing a ritual: patients with a ritualized routine for when, where, and how to self-inject were more confident. If doctors and nurses can support patients by providing a greater choice of treatments and injection devices, and teaching more about self-injection, this could improve patients' experiences and allow medications to work better. Healthcare professionals should help patients to develop their own, optimal routine for self-injection.

15.
Rheumatol Ther ; 4(1): 57-69, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28353191

ABSTRACT

INTRODUCTION: The safety and efficacy of certolizumab pegol (CZP) 400 mg every 4 weeks (Q4W) monotherapy (FAST4WARD/NCT00548834) and in combination with methotrexate (MTX) (014/NCT00544154) in active rheumatoid arthritis (RA) has been published previously. This report outlines final long-term outcomes from the open-label extension (OLE) study (015/NCT00160693), which enrolled patients from these randomized controlled trials (RCTs). METHODS: Patients who withdrew from or completed the 24-week 014/FAST4WARD RCTs were enrolled and received CZP 400 mg Q4W with/without MTX. Exposure-adjusted event rates (ER) per 100 patient-years (PYs) of adverse events (AEs) and serious AEs (SAEs) were reported for all patients receiving ≥1 dose of CZP in RCTs or OLE (N = 427) between first CZP dose and up to 24 weeks after last CZP dose or study withdrawal. Efficacy assessments included clinical (ACR20/50/70 response rates, TJC, SJC) and patient-reported outcomes (HAQ-DI, PtGADA, pain, fatigue) to week 304 (5.8 years) in the CZP intent-to-treat population. SDAI and CDAI outcomes were analyzed post hoc. Outcomes for CZP monotherapy and CZP+MTX combination-therapy were compared. RESULTS: Globally, ERs of AEs and SAEs were 408.1 and 25.2 per 100 PY, respectively. Eleven patients had AEs leading to death (ER 0.6). Improvements in clinical and patient-reported outcomes during the 24-week RCTs were maintained to week 304, and were similar between all subpopulations. CONCLUSIONS: The longest exposure duration to date with CZP 400 mg Q4W treatment confirmed the safety profile observed in previous studies. Initial improvements in signs and symptoms of RA, including PROs, were maintained in both CZP monotherapy and CZP + MTX combination-therapy patients. TRIAL REGISTRATION: ClinicalTrials.gov identifier, NCT00160693. FUNDING: UCB Pharma.

16.
Expert Opin Drug Deliv ; 14(1): 15-22, 2017 Jan.
Article in English | MEDLINE | ID: mdl-27801596

ABSTRACT

OBJECTIVES: To compare the usability of a new certolizumab pegol (CZP) autoinjector with the adalimumab, etanercept, and golimumab devices in patients with rheumatoid arthritis. METHODS: Two identical studies were performed in 2013 and 2016; patients performed a simulated self-injection with the CZP autoinjector and the most up-to-date device versions at the time in a randomized, consecutive sequence. The primary end point was the ranking of the four autoinjectors in order of preference. Device usability and intuitiveness were assessed across a range of secondary and exploratory end points. RESULTS: The 2013 and 2016 study populations included 76 patients each; a significant majority (2013: 67%; 2016: 59%) ranked the CZP autoinjector as their most preferred device (p < 0.001). Most patients agreed that the CZP autoinjector was easier to use, start, and manipulate, and were more willing to use it than the comparator devices (p < 0.001 for all pairwise comparisons with CZP). Likert score differences also favored the CZP autoinjector regarding how easy it was to determine injection completion. The CZP autoinjector was associated with a low rate of use error. CONCLUSIONS: In both studies, the CZP autoinjector was the preferred choice compared to the alternative devices and was associated with a high level of patient satisfaction.


Subject(s)
Antirheumatic Agents/administration & dosage , Arthritis, Rheumatoid/drug therapy , Certolizumab Pegol/administration & dosage , Adult , Aged , Female , Humans , Injections , Male , Middle Aged , Patient Satisfaction , Treatment Outcome
17.
Arthritis Res Ther ; 17: 245, 2015 Sep 10.
Article in English | MEDLINE | ID: mdl-26353833

ABSTRACT

INTRODUCTION: As patients with rheumatoid arthritis (RA) receive treatment with anti-tumour necrosis factors over several years, it is important to evaluate their long-term safety and efficacy. The objective of this study was to examine the safety and benefits of certolizumab pegol (CZP)+methotrexate (MTX) treatment for almost 5 years in patients with RA. METHODS: Patients who completed the 24-week Rheumatoid Arthritis Prevention of Structural Damage (RAPID) 2 randomized controlled trial (RCT; NCT00160602), or who were American College of Rheumatology (ACR) 20 non-responders at Week 16, entered the open-label extension (OLE; NCT00160641). After ≥6 months treatment with CZP 400 mg every two weeks (Q2W), dose was reduced to 200 mg Q2W, the approved maintenance dose. Safety data are presented from all patients who received ≥1 dose CZP (Safety population, n=612). Efficacy data are presented to Week 232 for the intent-to-treat (ITT, n=492) and Week 24 CZP RCT Completer (n=342) populations, and through 192 weeks of dose-reduction for the Dose-reduction population (patients whose CZP dose was reduced to 200 mg, n=369). Radiographic progression (modified total Sharp score change from RCT baseline >0.5) to Week 128 is reported for the Week 24 CZP Completers. RESULTS: In the RCT, 619 patients were randomized to CZP+MTX (n=492) or placebo+MTX (n=127). Overall, 567 patients (91.6%) entered the OLE: 447 CZP and 120 placebo patients. Of all randomized patients, 358 (57.8%) were ongoing at Week 232. Annual drop-out rates during the first four years ranged from 8.4-15.0%. Event rates per 100 patient-years were 163.0 for adverse events (AEs) and 15.7 for serious AEs. Nineteen patients (3.1%) had fatal AEs (incidence rate=0.8). Clinical improvements in the RCT were maintained to Week 232 in the CZP Completers: mean Disease Activity Score 28 (Erythrocyte Sedimentation Rate) change from baseline was -3.4 and ACR20/50/70 responses 68.4%/47.1%/25.1% (non-responder imputation). Similar improvements observed in the ITT were maintained following dose-reduction. 73.2% of CZP Completers had no radiographic progression at Week 128. CONCLUSIONS: In patients with active RA despite MTX therapy, CZP was well tolerated, with no new safety signals identified. CZP provided sustained improvements in clinical outcomes for almost 5 years. TRIAL REGISTRATION: ClinicalTrials.gov, NCT00160602 and NCT00160641 . Registered 8 September 2005.


Subject(s)
Arthritis, Rheumatoid/drug therapy , Arthritis, Rheumatoid/prevention & control , Certolizumab Pegol/therapeutic use , Methotrexate/therapeutic use , Adult , Aged , Antirheumatic Agents/adverse effects , Antirheumatic Agents/therapeutic use , Certolizumab Pegol/adverse effects , Dose-Response Relationship, Drug , Drug Administration Schedule , Drug Therapy, Combination , Female , Humans , Infections/chemically induced , Kaplan-Meier Estimate , Male , Methotrexate/adverse effects , Middle Aged , Time Factors , Treatment Outcome
18.
J Exp Biol ; 205(Pt 23): 3729-37, 2002 Dec.
Article in English | MEDLINE | ID: mdl-12409499

ABSTRACT

Effects of the extract of Nigella arvensis (NA) seeds on transepithelial Na(+) transport were studied in cultured A6 toad kidney cells by recording short-circuit current (I(sc)), transepithelial conductance (G(T)), transepithelial capacitance (C(T)) and fluctuation in I(sc). Apical application of NA extract had merely a small stimulatory effect on Na(+) transport, whereas basolateral administration markedly increased I(sc), G(T) and C(T). A maximal effect was obtained at 500 microll(-1) of lyophilized NA extract. The increase in C(T) suggests that the activation of I(sc) occurs through the insertion of transport sites in the apical membrane. In experiments performed in the absence of Na(+) transport [apical Na(+) was replaced by N-methyl-D-glucamine (NMDG(+))], basolateral NA extract did not affect I(sc) and G(T), indicating that Cl(-) conductance was not influenced. Noise analysis of I(sc) using 6-chloro-3,5-diaminopyrazine-2-carboxamide (CDPC) showed that NA extract reduced single-channel current (i(Na)) and decreased channel open probability (P(o)) but evoked a threefold increase in channel density (N(T)), which confirms the insertion of Na(+) channels. The separation of the compounds in the crude extract of NA was performed by fast protein liquid chromatography (FPLC) on a Superdex 200 gel-filtration column and by reverse-phase high-pressure liquid chromatography (RPHPLC) on an micro RPC C2/C18 SC2.1/10 column connected to a SMART system. Analysis of the purified active fraction by mass spectrometry demonstrated the presence of adenosine as the single organic compound in the extract that had a stimulatory effect on Na(+) transport. In a separate series of experiments, we confirmed that 1 micromol l(-1) adenosine had similar effects on the parameters of Na(+) transport as did the NA extract. The action of adenosine was further identified by experiments in which NA extract was added after adenosine. In these experiments, NA extract did not affect I(sc), G(T) or C(T). These results clearly demonstrate an essential role of adenosine in the stimulatory action of NA extract.


Subject(s)
Adenosine/pharmacology , Kidney/metabolism , Nigella/chemistry , Plant Extracts/pharmacology , Seeds/chemistry , Sodium/metabolism , Animals , Anura , Biological Transport/drug effects , Cell Line , Chlorides/metabolism , Chromatography, Gel , Chromatography, High Pressure Liquid , Electric Conductivity , Epithelium/metabolism , Kinetics , Mass Spectrometry , Mathematics , Sodium Channels/physiology , Solutions
19.
Hypertension ; 37(1): 135-141, 2001 Jan.
Article in English | MEDLINE | ID: mdl-11208768

ABSTRACT

-Altered Ca(2+) handling is observed in different cells in essential hypertension. We investigated the expression of sarco(endo)plasmic reticulum Ca(2+)-ATPase (SERCA) and inositol 1,4,5-trisphosphate receptor (IP(3)R) isoforms in platelets and aortic endothelial cells (EC) isolated from spontaneously hypertensive (SHR) and Wistar-Kyoto (WKY) rats by ratio reverse-transcriptase-polymerase chain reaction (RT-PCR) analysis and Western blotting. SERCA2b and SERCA3 were assessed at mRNA (EC and platelets) and at protein level (platelets). IP(3)R1, IP(3)R2, and IP(3)R3 mRNAs were demonstrated in both cell types, but only IP(3)R1 and IP(3)R2 proteins were detected in platelets. Compared with WKY, SHR EC and platelets showed higher SERCA3 and IP(3)R2 expression and lower IP(3)R1 expression. We then investigated the effect of lisinopril (20 mg. kg(-)(1). d(-)(1); 10-week treatment of 4-week-old rats or 2-week treatment of adult rats) and captopril (100 mg. kg(-)(1). d(-)(1); 2-week treatment of adult rats). Consequently, expression patterns of SERCAs and IP(3)Rs were significantly modified. Except for SERCAs mRNA in platelets, all differences between SHR and WKY disappeared. However, SERCA3 remained the predominant isoform. Both EC and platelets demonstrated a high equal expression of IP(3)R2 mRNA. IP(3)R1 was the predominant platelet protein isoform, as it was in untreated WKY. mRNA was also isolated from pancreatic islets of WKY and SHR, but no effect of either rat strain or of lisinopril treatment was observed on the expression of the studied genes. We hypothesize that the identical expression pattern of SERCAs and IP(3)Rs after treatment with ACE inhibitors represents a different nonhypertensive configuration, which, through changes in intracellular Ca(2+) handling, improves endothelial and platelet dysfunction in SHR but has no effect in WKY.

SELECTION OF CITATIONS
SEARCH DETAIL