1.
Phys Med Biol ; 2024 Jul 25.
Article in English | MEDLINE | ID: mdl-39053501

ABSTRACT

OBJECTIVE: Low-count positron emission tomography (PET) imaging is an efficient way to promote more widespread use of PET because of its short scan time and low injected activity. However, this often leads to low-quality PET images with clinical image reconstruction, due to high noise and blurring effects. Existing PET image restoration (IR) methods hinder their own restoration performance due to the semi-convergence property and the lack of suitable denoiser prior. Approach. To overcome these limitations, we propose a novel deep plug-and-play IR method called Deep denoiser Prior driven Relaxed Iterated Tikhonov method (DP-RI-Tikhonov). Specifically, we train a deep convolutional neural network (CNN) denoiser to generate a flexible deep denoiser prior to handle high noise. Then, we plug the deep denoiser prior as a modular part into a novel iterative optimization algorithm to handle blurring effects and propose an adaptive parameter selection strategy for the iterative optimization algorithm. Main results. Simulation results show that the deep denoiser prior plays the role of reducing noise intensity, while the novel iterative optimization algorithm and adaptive parameter selection strategy can effectively eliminate the semi-convergence property. They enable DP-RI-Tikhonov to achieve an average quantitative result (normalized root mean square error, structural similarity) of (0.1364, 0.9574) at the stopping iteration, outperforming a conventional PET IR method with an average quantitative result of (0.1533, 0.9523) and a state-of-the-art deep plug-and-play IR method with an average quantitative result of (0.1404, 0.9554). Moreover, the advantage of DP-RI-Tikhonov becomes more obvious at the last iteration. Experiments on six clinical whole-body PET images further indicate that DP-RI-Tikhonov successfully reduces noise intensity and recovers fine details, recovering sharper and more uniform images than the comparison methods. Significance. DP-RI-Tikhonov's ability to reduce noise intensity and effectively eliminate the semi-convergence property overcomes the limitations of existing methods. This advancement may have substantial implications for other medical IR.

2.
Med Phys ; 2024 Jul 10.
Article in English | MEDLINE | ID: mdl-38984805

ABSTRACT

BACKGROUND: Positron emission tomography (PET) has been investigated for its ability to reconstruct proton-induced positron activity distributions in proton therapy. This technique holds potential for range verification in clinical practice. Recently, deep learning-based dose estimation from positron activity distributions shows promise for in vivo proton dose monitoring and guided proton therapy. PURPOSE: This study evaluates the effectiveness of three classical neural network models, recurrent neural network (RNN), U-Net, and Transformer, for proton dose estimating. It also investigates the characteristics of these models, providing valuable insights for selecting the appropriate model in clinical practice. METHODS: Proton dose calculations for spot beams were simulated using Geant4. Computed tomography (CT) images from four head cases were utilized, with three for training neural networks and the remaining one for testing. The neural networks were trained with one-dimensional (1D) positron activity distributions as inputs and generated 1D dose distributions as outputs. The impact of the number of training samples on the networks was examined, and their dose prediction performance in both homogeneous brain and heterogeneous nasopharynx sites was evaluated. Additionally, the effect of positron activity distribution uncertainty on dose prediction performance was investigated. To quantitatively evaluate the models, mean relative error (MRE) and absolute range error (ARE) were used as evaluation metrics. RESULTS: The U-Net exhibited a notable advantage in range verification with a smaller number of training samples, achieving approximately 75% of AREs below 0.5 mm using only 500 training samples. The networks performed better in the homogeneous brain site compared to the heterogeneous nasopharyngeal site. In the homogeneous brain site, all networks exhibited small AREs, with approximately 90% of the AREs below 0.5 mm. The Transformer exhibited the best overall dose distribution prediction, with approximately 92% of MREs below 3%. In the heterogeneous nasopharyngeal site, all networks demonstrated acceptable AREs, with approximately 88% of AREs below 3 mm. The Transformer maintained the best overall dose distribution prediction, with approximately 85% of MREs below 5%. The performance of all three networks in dose prediction declined as the uncertainty of positron activity distribution increased, and the Transformer consistently outperformed the other networks in all cases. CONCLUSIONS: Both the U-Net and the Transformer have certain advantages in the proton dose estimation task. The U-Net proves well suited for range verification with a small training sample size, while the Transformer outperforms others at dose-guided proton therapy.

3.
Phys Med Biol ; 69(12)2024 Jun 07.
Article in English | MEDLINE | ID: mdl-38776949

ABSTRACT

Objective. In-beam positron emission tomography (PET) is a promising technology for real-time monitoring of proton therapy. Random coincidences between prompt radiation events and positron annihilation photon pairs can deteriorate imaging quality during beam-on operation. This study aimed to improve the PET image quality by filtering out the prompt radiation events.Approach. We investigated a prompt radiation event filtering method based on the accelerator radio frequency phase and assessed its performance using various prompt gamma energy thresholds. An in-beam PET prototype was used to acquire the data when the 70 MeV proton beam irradiated a water phantom and a mouse. The signal-to-background ratio (SBR) indicator was utilized to evaluate the quality of the PET reconstruction image.Main results. The selection of the prompt gamma energy threshold will affect the quality of the reconstructed image. Using the optimal energy threshold of 580 keV can obtain a SBR of 1.6 times for the water phantom radiation experiment and 2.0 times for the mouse radiation experiment compared to those without background removal, respectively.Significance. Our results show that using this optimal threshold can reduce the prompt radiation events, enhancing the SBR of the reconstructed image. This advancement contributes to more accurate real-time range verification in subsequent steps.


Subject(s)
Phantoms, Imaging , Positron-Emission Tomography , Proton Therapy , Proton Therapy/methods , Mice , Animals , Image Processing, Computer-Assisted/methods , Signal-To-Noise Ratio , Water