Int J Mol Sci ; 25(2)2024 Jan 17.
Article En | MEDLINE | ID: mdl-38256216

Regenerative Peripheral Nerve Interfaces (RPNIs) encompass neurotized muscle grafts employed for the purpose of amplifying peripheral nerve electrical signaling. The aim of this investigation was to undertake an analysis of the extant literature concerning animal models utilized in the context of RPNIs. A systematic review of the literature of RPNI techniques in animal models was performed in line with the PRISMA statement using the MEDLINE/PubMed and Embase databases from January 1970 to September 2023. Within the compilation of one hundred and four articles employing the RPNI technique, a subset of thirty-five were conducted using animal models across six distinct institutions. The majority (91%) of these studies were performed on murine models, while the remaining (9%) were conducted employing macaque models. The most frequently employed anatomical components in the construction of the RPNIs were the common peroneal nerve and the extensor digitorum longus (EDL) muscle. Through various histological techniques, robust neoangiogenesis and axonal regeneration were evidenced. Functionally, the RPNIs demonstrated the capability to discern, record, and amplify action potentials, a competence that exhibited commendable long-term stability. Different RPNI animal models have been replicated across different studies. Histological, neurophysiological, and functional analyses are summarized to be used in future studies.


Neovascularization, Pathologic , Animals , Mice , Action Potentials , Databases, Factual , Macaca , Models, Animal
2.
Sci Rep ; 10(1): 2819, 2020 02 18.
Article En | MEDLINE | ID: mdl-32071319

Intraoperative Neurophysiological Monitoring is a set of monitoring techniques consisting of reading electrical activity generated by the nervous system structures during surgeries. In order to guarantee signal quality, contact impedance between the sensing electrodes and the patient's skin needs to be as low as possible. Hence, monitoring this impedance while signals are measured is an important feature of current medical devices. The most commonly used technique involves injection of a known current and measurement of the voltage drop in the contact interface. This method poses several problems, such as power consumption (critical in battery-powered systems), frequency dependency and regulation issues, which are overcome by using a passive method. The fundamentals of the method proposed in this paper are based on the utilization of the variation suffered by the input random signal when a known resistance is connected in parallel to the input terminals of the low-noise amplifier (LNA) of the analog front-end of the acquisition system. Controlling the connection of the resistors and computing the root mean square of the LNA output voltage has been proved to be a useful tool to assess that the contact impedance is suitably low, allowing the user to know if the neural measurements obtained are valid.


Electric Impedance , Equipment Design , Intraoperative Neurophysiological Monitoring/instrumentation , Skin , Amplifiers, Electronic , Electrodes , Humans
...