Eur Cardiol ; 16: e25, 2021 Feb.
Article in English | MEDLINE | ID: mdl-34163538

ABSTRACT

Transcatheter mitral valve repair with the MitraClip, a catheter-based percutaneous edge-to-edge repair technique to correct mitral regurgitation (MR), has been demonstrated in Western studies to be an effective and safe MR treatment strategy. However, randomised clinical trial data on its use in Asian-Pacific patients is limited. Hence, the Asian Pacific Society of Cardiology convened an expert panel to review the available literature on MitraClip and to develop consensus recommendations to guide clinicians in the region. The panel developed statements on the use of MitraClip for the management of degenerative MR, functional MR, and other less common indications, such as acute MR, dynamic MR, hypertrophic obstructive cardiomyopathy, and MR after failed surgical repair. Each statement was voted on by each panel member and consensus was reached when 80% of experts voted 'agree' or 'neutral'. This consensus-building process resulted in 10 consensus recommendations to guide general cardiologists in the evaluation and management of patients in whom MitraClip treatment is being contemplated.

3.
Catheter Cardiovasc Interv ; 90(2): 257-268, 2017 Aug 01.
Article in English | MEDLINE | ID: mdl-27896904

ABSTRACT

OBJECTIVES: To describe the epidemiology, pathophysiology, clinical presentation, and management of contrast-induced encephalopathy (CIE) following cardiac catheterization. BACKGROUND: CIE is an acute, reversible neurological disturbance directly attributable to the intra-arterial administration of iodinated contrast medium. METHODS: The PubMed database was searched and all cases in the literature were retrieved and reviewed. RESULTS: 52 reports of CIE following cardiac catheterization were found. Encephalopathy, motor and sensory disturbances, vision disturbance, opthalmoplegia, aphasia, and seizures have been reported. Transient cortical blindness is the most commonly reported neurological syndrome, occurring in approximately 50% of cases. The putative mechanism involves disruption of the blood brain barrier and direct neuronal injury. Contrast-induced transient vasoconstriction has also been implicated. Symptoms typically appear within minutes to hours of contrast administration and resolve entirely within 24-48 hr. Risk factors may include hypertension, diabetes mellitus, renal impairment, the administration of large volumes of iodinated contrast, percutaneous coronary intervention or selective angiography of internal mammary grafts, and previous adverse reaction to iodinated contrast. Characteristic findings on cerebral imaging include cortical and sub-cortical contrast enhancement on computed tomography (CT). Imaging findings in CIE may mimic subarachnoid hemorrhage or cerebral ischemia; the Hounsfield scale on CT and the apparent diffusion coefficient on magnetic resonance imaging (MRI) are useful imaging tools in distinguishing these entities. In some cases, brain imaging is normal. Prognosis is excellent with supportive management alone. CIE tends to recur, although re-challenge with iodinated contrast without adverse effects has been documented. CONCLUSIONS: CIE is an important clinical entity to consider in the differential diagnosis of stroke following cardiac catheterization. Given that prognosis is excellent with supportive management only, physicians should be aware of it, and consider it prior to initiating thrombolysis. © 2016 Wiley Periodicals, Inc.


Subject(s)
Brain Diseases/chemically induced , Cardiac Catheterization/adverse effects , Contrast Media/adverse effects , Coronary Angiography/adverse effects , Radiography, Interventional/adverse effects , Adult , Aged , Aged, 80 and over , Brain Diseases/diagnosis , Brain Diseases/physiopathology , Brain Diseases/therapy , Contrast Media/administration & dosage , Diagnosis, Differential , Female , Humans , Infant , Male , Middle Aged , Predictive Value of Tests , Risk Assessment , Risk Factors , Stroke/diagnosis , Time Factors , Treatment Outcome
4.
Interv Cardiol ; 10(1): 49-54, 2015 Mar.
Article in English | MEDLINE | ID: mdl-29588674

ABSTRACT

Transcatheter aortic valve replacement with either the balloon-expandable Edwards SAPIEN XT valve, or the self-expandable CoreValve prosthesis has become the established therapeutic modality for severe aortic valve stenosis in patients who are not deemed suitable for surgical intervention due to excessively high operative risk. Native aortic valve regurgitation, defined as primary aortic incompetence not associated with aortic stenosis or failed valve replacement, on the other hand, is still considered a relative contraindication for transcatheter aortic valve therapies, because of the absence of annular or leaflet calcification required for secure anchoring of the transcatheter heart valve. In addition, severe aortic regurgitation often coexists with aortic root or ascending aorta dilatation, the treatment of which mandates operative intervention. For these reasons, transcatheter aortic valve replacement has been only sporadically used to treat pure aortic incompetence, typically on a compassionate basis and in surgically inoperable patients. More recently, however, transcatheter aortic valve replacement for native aortic valve regurgitation has been trialled with newer-generation heart valves, with encouraging results, and new ancillary devices have emerged that are designed to stabilize the annulus-root complex. In this paper we review the clinical context, technical characteristics and outcomes associated with transcatheter treatment of native aortic valve regurgitation.