Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 339
Filter
1.
J Orthop Case Rep ; 14(7): 30-35, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39035384

ABSTRACT

Introduction: Bilateral posterior fracture-dislocation of the shoulder is a very rare injury that is commonly missed. Almost 70% of bilateral posterior dislocations are due to convulsive seizures, with electric shocks accounting for < 5% of bilateral posterior shoulder dislocations. Case Report: The case of a walk-in patient, a 52-year-old man, with bilateral posterior fracture-dislocation of the shoulder caused by an electric shock is reported. Although he was initially admitted to the emergency department for observation of the potential complications of an electric shock, such as fatal arrhythmia and rhabdomyolysis, he subsequently consulted an orthopedic surgeon 4 days after the event due to persistent bilateral shoulder pain and was diagnosed using X-ray and computed tomography with bilateral posterior fracture-dislocation of the shoulder. Following open reduction and internal fixation 7 days after the injury, the upper limbs were fixed with shoulder braces at a slightly flexed and abducted position with neutral rotation for 3 weeks postoperatively followed by range of motion exercises. Twelve months after surgery, he had a Constant shoulder score of 94, an American Shoulder and Elbow Surgeon score of 100, and no shoulder re-dislocation or humeral head necrosis. Conclusion: In this walk-in patient, the diagnosis of bilateral posterior fracture-dislocation of the shoulder caused by an electric shock was delayed. We believe that understanding the mechanism of this type of injury will facilitate its early diagnosis.

2.
Arthroscopy ; 2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38697327

ABSTRACT

PURPOSE: To investigate the effects of ramp lesion (RL) and its repair on knee instability in patients with anterior cruciate ligament (ACL) injury by quantitatively assessing anteroposterior and rotational knee instability before and after ACL reconstruction. METHODS: All primary double-bundle ACL reconstructions using hamstring autografts between 2016 and 2021 were evaluated retrospectively. Patients with RLs without other meniscal injuries were included in group R, whereas those with isolated ACL injuries constituted group C. RL was repaired using all-inside devices in all patients in group R. Knee instability, including the amount of anterior tibial translation (ATT), and the acceleration and external rotational angular velocity of the knee joint (ERAV) during the pivot-shift test were assessed at the time of surgery. The pivot-shift test grade was recorded. RESULTS: A total of 73 patients were included in this study. Preoperatively, group R (n = 23) had significantly greater pivot-shift grades (P = .039), ATT (6.0 mm, group R; 4.5 mm, group C, P < .001), acceleration (6.8, 2.8; P = .037), and ERAV (3.9, 2.8; P = .001) than group C (n = 50). Intraoperatively, ATT (-1.0 mm, -1.0 mm; P < .001), acceleration (1.2, 1.1; P < .001), and ERAV (1.4, 1.2; P < .001) were significantly decreased compared with the preoperative values in both groups. No significant differences in these values were observed between groups R and C. CONCLUSIONS: ACL-injured knees accompanied by RLs exhibited significantly greater anteroposterior and rotatory instability than knees with isolated ACL injuries; increased knee instability can be effectively addressed by performing RL repair in conjunction with ACL reconstruction. The quantitative assessments employed-specifically measuring ATT, acceleration, and ERAV during the pivot-shift test-have allowed us to delineate these aspects of knee instability with greater precision. LEVEL OF EVIDENCE: Level Ⅲ, retrospective comparative study.

3.
Foot Ankle Surg ; 2024 May 16.
Article in English | MEDLINE | ID: mdl-38762338

ABSTRACT

BACKGROUND: Literature regarding the feasibility of inexperienced surgeons using needle arthroscopy is limited. The present study aimed to clarify the feasibility of performing ankle needle arthroscopy for inexperienced surgeons. METHODS: Diagnostic needle arthroscopy was performed for 10 cadaveric ankles by two surgeons with different levels of experience in ankle arthroscopy (inexperienced and expert surgeons). The visibility of arthroscopy was assessed based on a 15-point checklist and compared between surgeons. In addition, iatrogenic articular cartilage injury created by the inexperienced surgeon was investigated. RESULTS: The number of visible points was significantly larger for the expert surgeon than for the inexperienced surgeon (14.1 ± 1.0 vs. 13.7 ± 1.0, P = 0.035). The location of cartilage injury was greatest on the medial talar dome when viewing from the anteromedial portal at a rate of 30%. CONCLUSION: Ankle needle arthroscopy may be an option for surgeons in the future, however, differences in surgeon experience may impact effective visualization.

4.
Orthop J Sports Med ; 12(5): 23259671241248661, 2024 May.
Article in English | MEDLINE | ID: mdl-38726237

ABSTRACT

Background: There is a risk of cephalic vein injury during shoulder arthroscopy. However, limited data regarding its anatomic course are available. Purpose: To analyze the positional relationship and factors affecting the distance between the coracoid tip and cephalic veins. Study design: Case series; Level of evidence, 4. Methods: A total of 80 contrast-enhanced computed tomography images from 80 patients (mean age, 49.6 ± 20.3 years; 61 men) were retrospectively analyzed. The distance between the center of the coracoid tip and the vertical line through the cephalic vein was measured in the axial (D1) and sagittal (D2) planes. The distance between 1 cm lateral to the center of the coracoid tip and the vertical line through the cephalic vein was measured in the sagittal plane (D3). Each distance was compared according to patient sex and laterality. Associations between each distance and the patient's age, height, weight, and body mass index were investigated. Results: The mean D1 was 18.4 ± 7.3 mm in 59 patients. The mean D2 was 23.4 ± 11.6 mm, and it was within 10 mm in 10 patients (12.5%). The mean D3 was 33.7 ± 12.2 mm. There was no significant difference in D1, D2, and D3 according to patient sex or laterality. A positive correlation was observed only between D3 and patient height (r = 0.320; P = .034). Conclusion: The cephalic vein was found to travel a mean of 23.4 mm distal and 33.7 mm distal to 1 cm lateral to the coracoid tip. Therefore, Care should be taken to avoid cephalic vein injury when creating an anterior inferior portal or 5-o'clock portal around these areas.

5.
J Knee Surg ; 2024 Jun 14.
Article in English | MEDLINE | ID: mdl-38788784

ABSTRACT

INTRODUCTION: In most previous studies investigating return to preinjury level of sport (RTPS) after anterior cruciate ligament reconstruction (ACLR), whether patients continue aiming for RTPS not only before but also after ACLR was unclear because environmental and social factors were not considered. Herein, we aimed to evaluate factors associated with RTPS among athletes who desired to achieve RTPS even after ACLR, excluding patients who no longer desire this goal owing to environmental and social factors. METHODS: Ninety-two patients who underwent primary double-bundle ACLR with a minimum 2-year follow-up and desired to achieve RTPS before surgery were retrospectively enrolled. Twelve (13%) patients who no longer desired to achieve RTPS after ACLR owing to environmental and social factors were excluded. Sixty-nine patients were included in the final cohort. At the final follow-up, the patients were split into two groups: those who achieved (R group) or did not achieve (N group) RTPS based on patient self-assessment. The Knee Injury and Osteoarthritis Outcome Score (KOOS) and Lysholm scores were also determined. The anterior tibial translation in the Lachman test and acceleration and external rotational angular velocity (ERAV) in the pivot shift test were measured at the hardware removal operation. RESULTS: Significant differences were observed for preinjury level of sports between the groups (p < 0.05). The rate of RTPS in competitive athletes was lower than that in recreational athletes (20/46: 43% vs. 16/22: 73%; p =.037). Lysholm score, KOOS symptom, pain, and quality of life showed higher values in the R group than in the N group (p < 0.050). Acceleration was significantly lower in the R group than in the N group (p = 0.028). CONCLUSION: Competitive level of sports is a risk factor for failure to achieve RTPS. The postoperative functional outcomes in the group that achieved RTPS showed more favorable results. These results provide important information to enable the surgeons to consider the appropriate surgical plan for competitive athletes who desire to achieve RTPS after ACLR.

6.
Article in English | MEDLINE | ID: mdl-38642876

ABSTRACT

BACKGROUND: Several reconstruction methods exist for Malawer type I/V proximal humerus reconstruction after bone tumor resection; however, no consensus has been reached regarding the preferred methods. METHODS: We conducted a literature search on various types of proximal humerus oncologic reconstruction methods. We collected data on postoperative functional outcomes assessed based on Musculoskeletal Tumor Society (MSTS) scores, 5-year reconstruction survival rates, and complications. We calculated each reconstruction's weighted mean based on the sample size and standard errors. Complications were categorized based on the Henderson classification. Based on these integrated data, our primary objective is to propose an optimal strategy for proximal humerus reconstruction after bone tumor resection. RESULTS: We examined various reconstruction techniques, including modular prosthesis (752 patients in 21 articles), osteoarticular allograft (142 patients in 6 articles), allograft prosthesis composites (APCs) (236 patients in 12 articles), reverse shoulder total arthroplasty (141 patients in 10 articles), composite reverse shoulder total arthroplasty (33 patients in 4 articles), claviculo-pro-humero (CPH) technique (51 patients in 6 articles), and cement spacer (207 patients in 4 articles). Weighted mean MSTS scores were: modular prosthesis (73.8%), osteoarticular allograft (74.4%), APCs (79.2%), reverse shoulder total arthroplasty (77.0%), composite reverse shoulder total arthroplasty (76.1%), CPH technique (75.1%), and cement spacer (69.1%). Weighted 5-year reconstruction survival rates were modular prosthesis (85.4%), osteoarticular allograft (67.6%), APCs (85.2%), reverse shoulder total arthroplasty (84.1%), and cement spacer (88.0%). Reconstruction survival data was unavailable for composite reverse shoulder total arthroplasty and CPH technique. Major complications included shoulder joint instability: modular prosthesis (26.2%), osteoarticular allograft (41.5%), APCs (33.9%), reverse shoulder total arthroplasty (17%), composite reverse shoulder total arthroplasty (6.1%), CPH technique (2.0%), and cement spacer (8.7%). Aseptic loosening of the prosthesis occurred: modular prosthesis (3.9%) and reverse shoulder total arthroplasty (5.7%). Allograft fracture was observed in 54.9% of patients with osteoarticular allograft. CONCLUSION: The complication profiles differed among reconstruction methods. Weighted mean MSTS scores exceeded 70% in all methods except cement spacer, and the 5-year reconstruction survival rate surpassed 80% for all methods except osteoarticular allograft. Proximal humerus reconstruction after bone tumor resection should consider potential complications and patients' individual factors.

7.
Knee Surg Sports Traumatol Arthrosc ; 32(5): 1332-1343, 2024 May.
Article in English | MEDLINE | ID: mdl-38520187

ABSTRACT

PURPOSE: This study aimed to elucidate the characteristics of varus knee deformities in the Japanese population, prevalence of various around knee osteotomy procedures and influence of femoral and tibial bowing. METHODS: Varus knee deformity was defined as a weight-bearing line ratio of <50%. A total of 1010 varus knees were selected from 1814 varus knees with weight-bearing full-length radiographs, obtained at two facilities, based on exclusion criteria. Various parameters were measured, and around knee osteotomy simulations based on the deformity centre were conducted using digital planning tools. Bowing of the femoral and tibial shafts was measured, with bowing defined as follows: ≤ -0.6° indicating lateral bowing and ≥ 0.6° indicating medial bowing. Statistical analysis was performed to investigate age-related correlations and their impact on surgical techniques. RESULTS: The study revealed that the proximal tibia was the centre of deformity in Japanese varus knees (42.8%), and high tibial osteotomy was frequently indicated (81.6%). Age demonstrated a mild correlation with femoral shaft bowing (r = -0.29), leading to an increase in the mechanical lateral distal femoral angle and to a decrease in the hip-knee-ankle angle and weight-bearing line ratio (r = -0.29, 0.221, 0.219). The tibial shaft bowing was unaffected by age (r = -0.022). CONCLUSION: A significant proportion of Japanese individuals with varus knees exhibit a deformity centre located in the proximal tibia, making them suitable candidates for high tibial osteotomy. No age-related alterations were discerned in tibial morphology, indicating that the occurrence of constitutional varus knees is attributable to tibial deformities in the Japanese patient cohort. LEVEL OF EVIDENCE: Level IV.


Subject(s)
Knee Joint , Osteotomy , Tibia , Adult , Aged , Female , Humans , Male , Middle Aged , East Asian People , Femur/surgery , Femur/abnormalities , Femur/diagnostic imaging , Japan , Knee Joint/surgery , Knee Joint/diagnostic imaging , Knee Joint/abnormalities , Osteotomy/methods , Radiography , Tibia/surgery , Tibia/abnormalities , Tibia/diagnostic imaging , Weight-Bearing , Aged, 80 and over
8.
Article in English | MEDLINE | ID: mdl-38352644

ABSTRACT

Background: An unstable trochanteric femoral fracture is a serious injury, with a 1-year mortality rate of 5.4% to 24.9%, for which there is currently no standard treatment method. The lag screw insertion site is one of the primary contact areas between the cortical bone and an intramedullary nail. We hypothesized that a posterolateral fracture causes intramedullary nail instability when the posterolateral fracture line interferes with lag screw insertion. The purpose of the present study was to investigate the effect of posterolateral fracture line morphology on intramedullary nail stability by simulating unstable trochanteric femoral fractures with a posterolateral fracture fragment. Methods: Eighteen custom-made synthetic osteoporotic bone samples were used in the present study. Nine samples had a posterolateral fracture line interfering with the lag screw insertion hole (Fracture A), and the other 9 had a fracture line 10 mm away from the hole (Fracture B). Cyclic loading (750 N) was applied to the femoral head 1,500 times. Movement of the end cap attached to the intramedullary nail was recorded. The amplitudes of motion in the coronal plane (coronal swing motion), sagittal plane (sagittal swing motion), and axial plane (total swing motion) were evaluated. The change in the neck-shaft angle was evaluated on photographs that were made before and after the test. Medial cortical displacement was measured before and after the test. Results: Two Fracture-A samples were excluded because the amplitude of sagittal swing motion was too large. The mean values for coronal, sagittal, and total swing motion were 1.13 ± 0.28 mm and 0.51 ± 0.09 mm (p < 0.001), 0.50 ± 0.12 mm and 0.46 ± 0.09 mm (p = 0.46), and 1.24 ± 0.24 mm and 0.69 ± 0.11 mm (p < 0.001) for Fractures A and B, respectively. The mean neck-shaft angle change was -8.29° ± 2.69° and -3.56° ± 2.35° for Fractures A and B, respectively (p = 0.002). The mean displacement of the medial cortex was 0.38 ± 1.12 mm and 0.12 ± 0.37 mm for Fractures A and B, respectively (p = 0.57). Conclusions: This study showed that an unstable trochanteric femoral fracture with a posterolateral fracture line that interferes with the lag screw insertion holes is a risk factor for increased intramedullary nail instability.

9.
Medicine (Baltimore) ; 103(5): e37145, 2024 Feb 02.
Article in English | MEDLINE | ID: mdl-38306532

ABSTRACT

INTRODUCTION: A posterior-only total en bloc spondylectomy (TES) of the L3 level was deemed a highly intricate surgical procedure, necessitating the preservation of the L3 nerve root to prevent neurological deterioration. Despite bilateral preservation efforts of the L3 nerve roots, neurological deterioration proved unavoidable. This study aims to present the clinical, neurologic, and oncologic outcomes of spinal metastasis patients who underwent a posterior-only approach TES, encompassing the L3 vertebra. MATERIALS AND METHODS: All patients with L3-involved spinal metastasis undergoing posterior TES between January 2018 and January 2022 were investigated. The primary outcomes considered were the local recurrence rate and manual muscle testing of the lumbar myotome. Secondary outcomes included Frankel neurological status, operative time, blood loss, perioperative and postoperative complications, and Eastern Cooperative Oncology Group score. RESULTS: Five patients with TES involving L3 (three females) met the inclusion criteria. All patients had solitary metastases (three in the lungs, 2 in the breasts). Postoperatively, all patients experienced weakness of the hip flexors, but they were able to ambulate independently 12 months after surgery. One patient exhibited adjacent segment (L2) disease progression and underwent corpectomy 18 months after TES. No local recurrences at the surgical site were detected on magnetic resonance imaging at the 1-year follow-up. CONCLUSION: Posterior-only TES for L3-involved vertebrae yielded excellent results in the local control of metastatic disease. Despite hip flexor weakness, all patients were able to regain independent ambulation after 12 months. TES can offer favorable clinical and oncological outcomes in patients with solitary spinal metastases.


Subject(s)
Spinal Neoplasms , Female , Humans , Spinal Neoplasms/pathology , Retrospective Studies , Lumbar Vertebrae/surgery , Lumbar Vertebrae/pathology , Magnetic Resonance Imaging
10.
BMC Musculoskelet Disord ; 25(1): 115, 2024 Feb 08.
Article in English | MEDLINE | ID: mdl-38331756

ABSTRACT

BACKGROUND: Instrumentation failure (IF) is a major complication associated with growth-sparing surgery for pediatric spinal deformities; however, studies focusing on IF following each surgical procedure are lacking. We aimed to evaluate the incidence, timing, and rates of unplanned return to the operating room (UPROR) associated with IF following each surgical procedure in growth-sparing surgeries using traditional growing rods (TGRs) and vertical expandable prosthetic titanium ribs (VEPTRs). METHODS: We reviewed 1,139 surgical procedures documented in a Japanese multicenter database from 2015 to 2017. Of these, 544 TGR and 455 VEPTR procedures were included for evaluation on a per-surgery basis. IF was defined as the occurrence of an implant-related complication requiring revision surgery. RESULTS: The surgery-based incidences of IF requiring revision surgery in the TGR and VEPTR groups were 4.3% and 4.0%, respectively, with no significant intergroup difference. Remarkably, there was a negative correlation between IF incidence per surgical procedure and the number of lengthening surgeries in both groups. In addition, rod breakage in the TGR group and anchor-related complications in the VEPTR group tended to occur relatively early in the treatment course. The surgery-based rates of UPROR due to IF in the TGR and VEPTR groups were 2.0% and 1.5%, respectively, showing no statistically significant difference. CONCLUSIONS: We found that IF, such as anchor related-complications and rod breakage, occurs more frequently earlier in the course of lengthening surgeries. This finding may help in patient counseling and highlights the importance of close postoperative follow-up to detect IF and improve outcomes.


Subject(s)
Scoliosis , Child , Humans , Scoliosis/surgery , Scoliosis/diagnosis , Titanium , Prostheses and Implants/adverse effects , Ribs/surgery , Ribs/abnormalities , Reoperation , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Postoperative Complications/surgery , Spine/diagnostic imaging , Spine/surgery , Spine/abnormalities , Retrospective Studies , Treatment Outcome , Multicenter Studies as Topic
11.
Case Rep Orthop ; 2024: 5392926, 2024.
Article in English | MEDLINE | ID: mdl-38410683

ABSTRACT

Bite injuries frequently occur on human hands. Human bite injuries to the hand may lead to an infection because of limited soft tissue protection and wound contamination. However, no studies have reported severe bite injuries on hands treated by flaps. We report a case of an 80-year-old woman diagnosed with a major neurocognitive disorder. The patient accidentally had a self-bite injury accompanied with an open metacarpal fracture. Debridement and fixation of the first metacarpal fracture were performed. Afterward, skin necrosis occurred gradually on the dorsum of the hand. Therefore, a reverse posterior interosseous artery (PIA) flap was used, and the postoperative course was uneventful. Given the high risk of infection, human bite injuries, particularly hand bites, should be treated immediately. Delayed treatment for such injuries may lead to extensive soft tissue defects requiring reconstruction with flaps.

12.
Orthop J Sports Med ; 12(2): 23259671241230967, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38414663

ABSTRACT

Background: Postoperative residual rotatory laxity remains despite improvement in surgical techniques for anterior cruciate ligament (ACL) reconstruction (ACLR). Purpose: To evaluate factors associated with residual pivot shift after ACLR by quantitative measurement of the pivot shift before and after surgery. Study Design: Case-control study; Level of evidence, 3. Methods: A total of 97 patients who underwent primary double-bundle ACLR between June 2016 and March 2021 and underwent surgery to remove staples, with at least 12 months of follow-up evaluation, were enrolled. Quantitative measurements were performed under general anesthesia immediately before ACLR (preoperatively), after temporary fixation of the ACL graft (intraoperatively), and immediately before staple removal (postoperatively). The laxity of pivot shift was assessed using inertial sensors to measure acceleration and external rotational angular velocity (ERAV). Descriptive data were assessed for associations with postoperative acceleration and ERAV in a univariate analysis. A multiple linear regression analysis was performed to identify factors associated with postoperative acceleration and ERAV. Results: Anterior tibial translation, acceleration, and ERAV increased from intra- to postoperatively (P < .05). Factors significantly associated with postoperative acceleration were age (ß = -0.238; P = .021), lateral posterior tibial slope (PTS) (ß = 0.194; P = .048), and preoperative acceleration (ß = 0.261; P = .008). Factors significantly affecting postoperative ERAV were age (ß = -0.222; P = .029), ramp lesions (ß = 0.212; P = .027), and preoperative ERAV (ß = 0.323; P = .001). Conclusion: Greater preoperative laxity in the pivot shift was the factor having the most significant association with residual pivot shift after ACLR using quantitative measurements under general anesthesia. Younger age, higher lateral PTS, and concomitant ramp lesions were significant predictors of residual pivot shift. These findings can help pre- and intraoperative decision-making regarding whether an anterolateral structure augmentation should be added.

13.
Knee Surg Sports Traumatol Arthrosc ; 32(2): 257-264, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38226718

ABSTRACT

PURPOSE: The aim of this study is to assess the dynamics of the tear site of meniscal ramp lesions, particularly considering knee flexion angles, and validate anchor fixation using an all-inside device. METHODS: Eight Thiel-embalmed paired cadaveric knees with their whole bodies were used in this study. The ramp lesions were created arthroscopically, and ramp lesion dynamics were evaluated by gradually extending the knee from 90° of knee flexion. Changes in the gap and step-off (0: no step-off; 1: cross-sectional overlap exists; and 2: tibial articular surface exposed) were evaluated at 90°, 60°, 30°, and 10° of knee flexion. After dynamic evaluation, all-inside repairs of the ramp lesions using all-inside devices were conducted. Dissection was performed to confirm the position of anchor fixation. RESULTS: As the knee was extended, the gap significantly decreased at all knee flexion angles. Similarly, the step-off grade decreased as the knee was extended, and the step-off completely disappeared in all cases when the knee was extended from 30° to 10°. The average knee flexion angle at which the gap and step-off completely disappeared was 22.5°. After suturing the ramp lesion, arthroscopic evaluation showed that the gap had disappeared and the step-off had been repaired in all cases. Anchor fixation locations were not found within the joint but were fixed to the semimembranosus tendon or its surrounding articular capsule. Overall, 31% (5/16) anchors were fixed to the attachment site of the semimembranosus tendon, whereas the remaining were fixed to the articular capsule, located peripherally to the semimembranosus tendon. CONCLUSION: Suturing with an all-inside device for ramp lesions is a good option, and the repair in knee extension was found to be reasonable, considering the dynamics of ramp lesions in this study. LEVEL OF EVIDENCE: Level IV.


Subject(s)
Anterior Cruciate Ligament Injuries , Menisci, Tibial , Humans , Cross-Sectional Studies , Menisci, Tibial/surgery , Knee Joint/surgery , Knee , Cadaver , Anterior Cruciate Ligament Injuries/surgery
14.
Eur J Orthop Surg Traumatol ; 34(1): 217-223, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37421450

ABSTRACT

PURPOSE: Proximal humeral fractures cause large intramedullary bone defects after humeral-head reduction. Hydroxyapatite/poly-L-lactide (HA/PLLA) materials are widely used for various fractures. However, the efficacy of endosteal strut using a HA/PLLA mesh tube (ES-HA/PLLA) with a locking plate for treating proximal humeral fractures was not reported. The purpose of this study is to examine the efficacy of ES-HA/PLLA with a proximal humeral locking plate in proximal humeral fractures. METHODS: Seventeen patients with proximal humeral fractures treated using ES-HA/PLLA with a locking plate from November 2017 to November 2021 were evaluated. The range of motion of the shoulder and postoperative complications were assessed at the final follow-up. Radiographs were evaluated to assess bone union and loss of reduction by measuring humeral-head height (HHH) and humeral neck-shaft angle (NSA). RESULTS: The average flexion and external rotation of the shoulder at the final follow-up were 137° (range, 90-180°) and 39° (range, - 10 to 60°), respectively. All fractures were united. The average HHH and NSA just after the surgery and final follow-up were 12.5 mm and 11.6 mm and 129.9° and 127.4°, respectively. Two patients presented screw perforation of the humeral head. One patient underwent implant removal due to infection. Avascular necrosis of the humeral head was observed in one patient with arthritis mutilans. CONCLUSIONS: The use of ES-HA/PLLA with a proximal humeral locking plate resulted in bone union in all patients and prevented postoperative loss of reduction. ES-HA/PLLA is one of the treatment options for proximal humeral fractures.


Subject(s)
Humeral Fractures , Shoulder Fractures , Humans , Shoulder , Surgical Mesh , Fracture Fixation, Internal/adverse effects , Fracture Fixation, Internal/methods , Retrospective Studies , Shoulder Fractures/diagnostic imaging , Shoulder Fractures/surgery , Humeral Head , Hydroxyapatites , Bone Plates , Treatment Outcome , Humeral Fractures/surgery
15.
World Neurosurg ; 182: e463-e470, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38042291

ABSTRACT

OBJECTIVE: Verifying the intervertebral stability of each intervertebral fusion procedure, including transforaminal, posterior, and lateral lumbar interbody fusion (TLIF, PLIF, and LLIF, respectively), and the ratio of stress on the rods and pedicle screws during initial fixation may help select a fixation procedure that reduces the risk of mechanical complications, including rod fracture and screw loosening. Thus, we aimed to assess whether these procedures could prevent mechanical complications. METHODS: Using the finite element method (FEM), we designed 4 surgical models constructed from L2-5 as follows: posterior lumbar fusion (PLF), TLIF, PLIF, and LLIF models. Bilateral rods and each pedicle screw stress were tracked and calculated as Von Mises stress (VMS) for comparison among the PLF and other 3 interbody fusion models during flexion, extension, and side-bending movements. RESULTS: The lowest rod VMS was LLIF, followed by PLIF, TLIF, and PLF in flexion and side bending movements. Compared with PLF, intervertebral fixation significantly reduced stress on the rods. No remarkable differences were observed in extension movements in each surgical procedure. A tendency for higher pedicle screw VMS was noted at the proximal and distal ends of the fixation ranges, including L2 and L5 screws for each procedure in all motions. Intervertebral fixation significantly reduced stress on the L2 and L5 screws, particularly in LLIF. CONCLUSIONS: Stress on the rods and pedicle screws in the LLIF model was the lowest compared with that induced by other intervertebral fusion procedures. Therefore, LLIF may reduce mechanical complications occurrence, including rod fracture and screw loosening.


Subject(s)
Pedicle Screws , Spinal Fusion , Humans , Lumbar Vertebrae/surgery , Finite Element Analysis , Spinal Fusion/methods , Biomechanical Phenomena , Cadaver , Range of Motion, Articular
16.
Injury ; 55(2): 111172, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37951016

ABSTRACT

INTRODUCTION: This retrospective study evaluated the outcomes of variable-angle locking compression plate, mesh plate, or footplate box fixation for posterior acetabular wall fractures. PATIENTS AND METHODS: The study included nine patients with unstable posterior acetabular wall fractures who underwent internal fixation with the "spring-locking plate fixation method" between January 2015 and December 2019. Patient demographics, fracture classifications, surgical details, radiological and clinical evaluations, and complications were collected from electronic medical records. Statistical analyses were performed to assess the relationship between preoperative and postoperative dislocations. RESULTS: The mean age of the patients was 46 years, and the majority were men (88.9%). Fracture types included posterior wall fractures and posterior column plus posterior wall fractures. The mean operative time was 246 min and the mean blood loss was 663 mL. The surgical approaches included the Kocher-Langenbeck, Ganz trochanteric flip, and transtrochanteric approaches. Variable-angle locking compression plate mesh plates and footplate box type implants were used for fixation. The mean preoperative dislocation was 23 mm, which was significantly reduced to 1 mm immediately post-operation and at the final observation. The bone fusion rate was 100% and radiological and clinical evaluations revealed favourable outcomes. Complications were minimal, with mild heterotopic ossification observed in four patients. CONCLUSION: The spring-locking plate fixation method demonstrated satisfactory outcomes for the treatment of posterior acetabular wall fractures. This technique provides rigid fixation. Furthermore, the use of variable-angle locking screws minimizes the risk of intra-articular perforations. Despite limitations such as a small sample size and the absence of a control group, the results suggest that the spring-locking plate fixation method may be valuable in managing these fractures.


Subject(s)
Fractures, Bone , Joint Dislocations , Male , Humans , Female , Middle Aged , Retrospective Studies , Acetabulum/diagnostic imaging , Acetabulum/surgery , Surgical Mesh , Fractures, Bone/diagnostic imaging , Fractures, Bone/surgery , Fracture Fixation, Internal/methods , Bone Plates , Treatment Outcome
17.
Int J Low Extrem Wounds ; : 15347346231221116, 2023 Dec 13.
Article in English | MEDLINE | ID: mdl-38092691

ABSTRACT

Lower extremity amputation (LEA), particularly in patients with diabetes or peripheral vascular disease, often results in complications such as surgical site infections (SSIs) and wound dehiscence. This study examined whether utilizing the portable and user-friendly PICO system (Smith and Nephew Medical Ltd, Hull, UK) as incisional negative-pressure wound therapy can reduce post-LEA complications. This study was conducted at a Japanese tertiary medical center and involved a retrospective analysis of LEA cases (n = 32) between January 2021 and December 2022. The PICO dressing group (n = 16) was compared to the conventional dressing group (n = 16) for post-LEA wound management. The primary outcome was the incidence of postoperative wound complications, including SSI and wound dehiscence, within 15 days of LEA. Superficial/deep SSI and wound dehiscence occurred less frequently in the PICO dressing group than in the conventional dressing group (12.5% vs 43.8%; p = .054). There were no cases of deep SSIs in the PICO dressing group. Although this study has limitations owing to its retrospective design and small sample size, the results suggest the potential of the PICO system for improving outcomes in post-LEA wound management.

19.
Asian Spine J ; 17(6): 997-1003, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37946333

ABSTRACT

STUDY DESIGN: This experimental study was performed using human ligamentum flavum-derived cells (HFCs). PURPOSE: To investigate the intracellular signaling mechanism of interleukin-6 (IL-6) secretion in transforming growth factor-ß (TGF- ß)-stimulated HFCs. OVERVIEW OF LITERATURE: Lumbar spinal stenosis (LSS) is a prevalent disease among the elderly, characterized by debilitating pain in the lower extremities. Although the number of patients with LSS has increased in recent years, the underlying pathomechanism remains unclear. Clinical examinations typically rely on magnetic resonance imaging to diagnose patients, revealing ligamentum flavum hypertrophy. Some studies have suggested an association between ligamentum flavum hypertrophy and inflammation/fibrosis, and expression of TGF-ß and IL-6 has been observed in surgically obtained ligamentum flavum samples. However, direct evidence linking TGF-ß and IL-6 expression in HFCs is lacking. METHODS: HFCs were obtained from patients with LSS who had undergone decompression surgery. The cells were stimulated with TGF-ß and pretreated with either the p38 mitogen-activated protein (MAP) kinase inhibitor SB203580 or the p44/42 MAP kinase inhibitor FR180204. IL-6 secretion in the cell culture medium and IL-6 messenger RNA (mRNA) expression levels were analyzed using an enzyme-linked immunoassay and real-time polymerase chain reaction, respectively. RESULTS: TGF-ß administration resulted in a dose- and time-dependent stimulation of IL-6 release. Treatment with SB203580 and FR180204 markedly suppressed TGF-ß-induced IL-6 secretion from HFCs. Moreover, these inhibitors suppressed IL-6 mRNA expression in response to TGF-ß stimulation. CONCLUSIONS: Our findings indicate that TGF-ß induces IL-6 protein secretion and gene expression in HFCs through the activation of p38 or p44/42 MAP kinases. These results suggest a potential association between IL-6-mediated inflammatory response and tissue hypertrophy in LSS, and we provide insights into molecular targets for therapeutic interventions targeting LSS-related inflammation through our analysis of the MAP kinase pathway using HFCs.

20.
Spine Surg Relat Res ; 7(5): 428-435, 2023 Sep 27.
Article in English | MEDLINE | ID: mdl-37841038

ABSTRACT

Introduction: The number of patients on antithrombotic drugs for coronary heart disease or cerebrovascular disease has been increasing with the aging of society. We occasionally need to decide whether to continue or discontinue antithrombotic drugs before spine surgery. The purpose of this study is to understand the current perioperative management of antithrombotic drugs before elective spine surgery in Japan. Methods: In 2021, members of the Japanese Society for Spine Surgery and Related Research (JSSR) were asked to complete a web-based questionnaire survey that included items concerning the respondents' surgical experience, their policy regarding discontinuation or continuation of antithrombotic drugs, their reasons for decisions concerning the management of antithrombotic drugs, and their experience of perioperative complications related to the continuation or discontinuation of these drugs. Results: A total of 1,181 spine surgeons returned completed questionnaires, giving a response rate of 32.0%. JSSR board-certified spine surgeons comprised 75.1% of the respondents. Depending on the management policy regarding antithrombotic drugs for each comorbidity, approximately 73% of respondents discontinued these drugs before elective spine surgery, and about 80% also discontinued anticoagulants. Only 4%-5% of respondents reported continuing antiplatelet drugs, and 2.5% reported continuing anticoagulants. Among the respondents who discontinued antiplatelet drugs, 20.4% reported having encountered cerebral infarction and 3.7% reported encountering myocardial infarction; among those who discontinued anticoagulants, 13.6% reported encountering cerebral embolism and 5.4% reported encountering pulmonary embolism. However, among the respondents who continued antiplatelet drugs and those who continued anticoagulants, 26.3% and 27.2%, respectively, encountered an unexpected increase in intraoperative bleeding, and 10.3% and 8.7%, respectively, encountered postoperative spinal epidural hematoma requiring emergency surgery. Conclusions: Our findings indicate that, in principle, >70% of JSSR members discontinue antithrombotic drugs before elective spine surgery. However, those with a discontinuation policy have encountered thrombotic complications, while those with a continuation policy have encountered hemorrhagic complications.

SELECTION OF CITATIONS
SEARCH DETAIL