Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
Respir Res ; 25(1): 207, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38750572

ABSTRACT

BACKGROUND: The evidence regarding effects of statins on exacerbation risk in COPD remains controversial. Previous studies often excluded patients with cardiovascular comorbidities despite their high prevalence in COPD and role for exacerbations. Based on the cardioprotective properties of statins, we hypothesised that statins may reduce the risk of exacerbations especially in patients with cardiovascular comorbidities. METHODS: One thousand eight hundred eighty seven patients of the German COPD cohort COSYCONET (COPD and Systemic Consequences Comorbidities Network) of GOLD grades 1-4 (37.8% female, mean age 64.78 ± 8.3) were examined at baseline and over a period of 4.5 years for the occurrence of at least one exacerbation or severe exacerbation per year in cross-sectional and longitudinal analyses adjusted for age, gender, BMI, GOLD grade and pack-years. Due to their collinearity, various cardiovascular diseases were tested in separate analyses, whereby the potential effect of statins in the presence of a specific comorbidity was tested as interaction between statins and comorbidity. We also identified patients who never took statins, always took statins, or initiated statin intake during the follow-up. RESULTS: One thousand three hundred six patients never took statins, 31.6% were statin user, and 12.9% initiated statins during the follow-up. Most cardiovascular diseases were significantly (p < 0.05)may associated with an increased risk of COPD exacerbations, but in none of them the intake of statins was a significant attenuating factor, neither overall nor in modulating the increased risk linked to the specific comorbidities. The results of the cross-sectional and longitudinal analyses were consistent with each other, also those regarding at least 1 exacerbation or at least 1 severe exacerbation per year. CONCLUSION: These findings complement the existing literature and may suggest that even in patients with COPD, cardiovascular comorbidities and a statin therapy that targets these comorbidities, the effects of statins on exacerbation risk are either negligible or more subtle than a reduction in exacerbation frequency. TRIAL REGISTRATION: Trial registration ClinicalTrials.gov, Identifier: NCT01245933. Other Study ID (BMBF grant): 01GI0881, registered 18 November 2010, study start 2010-11, primary completion 2013-12, study completion 2023-09. https://clinicaltrials.gov/study/NCT01245933?cond=COPD&term=COSYCONET&rank=3.


Subject(s)
Cardiovascular Diseases , Comorbidity , Hydroxymethylglutaryl-CoA Reductase Inhibitors , Pulmonary Disease, Chronic Obstructive , Humans , Pulmonary Disease, Chronic Obstructive/epidemiology , Pulmonary Disease, Chronic Obstructive/drug therapy , Pulmonary Disease, Chronic Obstructive/diagnosis , Female , Male , Hydroxymethylglutaryl-CoA Reductase Inhibitors/therapeutic use , Middle Aged , Aged , Cardiovascular Diseases/epidemiology , Cardiovascular Diseases/drug therapy , Cardiovascular Diseases/prevention & control , Cross-Sectional Studies , Cohort Studies , Longitudinal Studies , Disease Progression , Germany/epidemiology , Follow-Up Studies
2.
Urologe A ; 39(3): 235-9, 2000 May.
Article in German | MEDLINE | ID: mdl-10872248

ABSTRACT

Experimental studies revealed that the contractile response of the urinary bladder to sacral anterior root stimulation depends on the actual bladder volume. Furthermore, no clinical relevant technique is available for continuous monitoring of the bladder wall distension respectively bladder volume in paraplegic patients. The presented study investigates the reliability of especially developed implantable ultrasound sensors as a sensoric system for continuous monitoring of the bladder volume. In six anaesthesized pigs two ultrasound sensors, one transmitter and one receiver, were implanted on the bladder wall at different locations (latero-lateral, dorsal-ventral, rostral-caudal). After closing the abdominal wall, the bladder was filled in 50 ml steps up to 250 ml. After each filling step the running time of the ultrasound signal was measured. In all experiments reproducible results and a high correlation of the measured running times with bladder volume were observed. The latero-lateral configuration of the sensors seemed to be most confidential. The presented study indicates that bladder volumetry with implantable ultrasound sensors is possible with minimal technical prerequisites. This promising technique for continuous bladder volumetry could play an important role in the development of an intelligent and autoadaptive neurostimulator of the urinary bladder in paraplegic patients.


Subject(s)
Electric Stimulation Therapy/instrumentation , Electrodes, Implanted , Spinal Nerve Roots/physiology , Ultrasonography/instrumentation , Urinary Bladder/innervation , Urodynamics/physiology , Animals , Male , Swine
SELECTION OF CITATIONS
SEARCH DETAIL
...