Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 35
1.
Pediatr Radiol ; 53(11): 2210-2220, 2023 10.
Article En | MEDLINE | ID: mdl-37500799

BACKGROUND: Pediatric radiologists can identify a liver ultrasound (US) pattern predictive of progression to advanced liver disease. However, reliably discriminating these US patterns remains difficult. Quantitative magnetic resonance imaging (MRI) may provide an objective measure of liver disease in cystic fibrosis (CF). OBJECTIVE: The purpose of this study was to determine if quantitative MRI, including MR elastography, is feasible in children with CF and to determine how quantitative MRI-derived metrics compared to a research US. MATERIALS AND METHODS: A prospective, multi-institutional trial was performed evaluating CF participants who underwent a standardized MRI. At central review, liver stiffness, fat fraction, liver volume, and spleen volume were obtained. Participants whose MRI was performed within 1 year of US were classified by US pattern as normal, homogeneous hyperechoic, heterogeneous, or nodular. Each MRI measure was compared among US grade groups using the Kruskal-Wallis test. RESULTS: Ninety-three participants (51 females [54.8%]; mean 15.6 years [range 8.1-21.7 years]) underwent MRI. MR elastography was feasible in 87 participants (93.5%). Fifty-eight participants had an US within 1 year of MRI. In these participants, a nodular liver had significantly higher stiffness (P<0.01) than normal or homogeneous hyperechoic livers. Participants with a homogeneous hyperechoic liver had a higher fat fraction (P<0.005) than others. CONCLUSION: MR elastography is feasible in children with CF. Participants with a nodular pattern had higher liver stiffness supporting the US determination of advanced liver disease. Participants with a homogeneous hyperechoic pattern had higher fat fractions supporting the diagnosis of steatosis.


Cystic Fibrosis , Elasticity Imaging Techniques , Liver Diseases , Child , Female , Humans , Cystic Fibrosis/diagnostic imaging , Cystic Fibrosis/pathology , Feasibility Studies , Liver/diagnostic imaging , Liver/pathology , Liver Cirrhosis/pathology , Liver Diseases/pathology , Magnetic Resonance Imaging/methods , Prospective Studies
2.
J Cyst Fibros ; 22(4): 745-755, 2023 07.
Article En | MEDLINE | ID: mdl-37032248

BACKGROUND: This study examines whether heterogeneous (HTG) pattern on liver ultrasound (US) identifies children at risk for advanced cystic fibrosis liver disease (aCFLD). METHODS: Prospective 6-year multicenter case-controlled cohort study. Children with pancreatic insufficient cystic fibrosis (CF) aged 3-12 years without known cirrhosis underwent screening US. Participants with HTG were matched (by age, Pseudomonas infection status and center) 1:2 with participants with normal (NL) US pattern. Clinical status and laboratory data were obtained annually and US bi-annually for 6 years. Primary endpoint was development of nodular (NOD) US pattern consistent with aCFLD. RESULTS: 722 participants underwent screening US, with 65 HTG and 592 NL. Final cohort included 55 HTG and 116 NL with ≥ 1 follow-up US. ALT, AST, GGTP, FIB-4, GPR and APRI were higher, and platelets were lower in HTG compared to NL. HTG had a 9.5-fold increased incidence (95% confidence interval [CI]:3.4, 26.7, p<0.0001, 32.7% vs 3.4%) of NOD versus NL. HTG had a sensitivity of 82% and specificity of 75% for subsequent NOD. Negative predictive value of a NL US for subsequent NOD was 96%. Multivariate logistic prediction model that included baseline US, age, and log(GPR) improved the C-index to 0.90 compared to only baseline US (C-index 0.78). Based on survival analysis, 50% of HTG develop NOD after 8 years. CONCLUSIONS: Research US finding of HTG identifies children with CF with a 30-50% risk for aCFLD. A score based on US pattern, age and GPR may refine the identification of individuals at high risk for aCFLD. CLINICAL TRIAL REGISTRATION: Prospective Study of Ultrasound to Predict Hepatic Cirrhosis in CF: NCT 01,144,507 (observational study, no consort checklist).


Cystic Fibrosis , Liver Diseases , Humans , Child , Prospective Studies , Cohort Studies , Cystic Fibrosis/complications , Cystic Fibrosis/epidemiology , Cystic Fibrosis/pathology , Platelet Count , Liver/diagnostic imaging , Liver/pathology , Liver Cirrhosis/diagnostic imaging , Liver Cirrhosis/epidemiology
3.
J Cyst Fibros ; 22(2): 248-255, 2023 03.
Article En | MEDLINE | ID: mdl-35985930

BACKGROUND: Nodular liver (NOD) in cystic fibrosis (CF) suggests advanced CF liver disease (aCFLD); little is known about progression of liver disease (LD) after detection of sonographic NOD. METHODS: Clinical, laboratory, and ultrasound (US) data from Prediction by Ultrasound of the Risk of Hepatic Cirrhosis in CFLD Study participants with NOD at screening or follow-up were compared with normal (NL). Linear mixed effects models were used for risk factors for LD progression and Kaplan-Meier estimator for time-to-event. RESULTS: 54 children with NOD (22 screening, 32 follow-up) and 112 NL were evaluated. Baseline (BL) and trajectory of forced expiratory volume, forced vital capacity, height/BMI z-scores were similar in NOD vs NL. Platelets were lower in NOD at BL (250 vs 331×103/microL; p < 0.001) and decreased by 8600/year vs 2500 in NL. Mean AST to Platelet Ratio Index (1.1 vs 0.4; p < 0.001), Fibrosis-4 Index (0.4 vs 0.2, p < 0.001), and spleen size z-score (SSZ) [1.5 vs 0.02; p < 0.001] were higher in NOD at BL; SSZ increased by 0.5 unit/year in NOD vs 0.1 unit/year in NL. Median liver stiffness (LSM) by transient elastography was higher in NOD (8.2 kPa, IQR 6-11.8) vs NL (5.3, 4.2-7, p < 0.0001). Over 6.3 years follow-up (1.3-10.3), 6 NOD had esophageal varices (cumulative incidence in 10 years: 20%; 95% CI: 0.0%, 40.0%), 2 had variceal bleeding, and 2 underwent liver transplantation; none had ascites or hepatic encephalopathy. No NL experienced liver-related events. CONCLUSIONS: NOD developed clinically evident portal hypertension faster than NL without worse growth or lung disease.


Cystic Fibrosis , Elasticity Imaging Techniques , Esophageal and Gastric Varices , Hypertension, Portal , Humans , Child , Follow-Up Studies , Cystic Fibrosis/complications , Cystic Fibrosis/epidemiology , Cystic Fibrosis/pathology , Esophageal and Gastric Varices/pathology , Gastrointestinal Hemorrhage/pathology , Liver/diagnostic imaging , Liver/pathology , Liver Cirrhosis/diagnostic imaging , Liver Cirrhosis/etiology
4.
J Pediatr Gastroenterol Nutr ; 75(5): 635-642, 2022 11 01.
Article En | MEDLINE | ID: mdl-36070552

OBJECTIVES: Cystic fibrosis liver disease (CFLD) begins early in life. Symptoms may be vague, mild, or nonexistent. Progressive liver injury may be associated with decrements in patient health before liver disease is clinically apparent. We examined Health-Related Quality of Life (HRQOL) in children enrolled in a multi-center study of CFLD to determine the impact of early CFLD on general and disease-specific QOL. METHODS: Ultrasound (US) patterns of normal (NL), heterogeneous (HTG), homogeneous (HMG), or nodular (NOD) were assigned in a prospective manner to predict those at risk for advanced CFLD. Parents were informed of results. We assessed parent/child-reported (age ≥5 years) HRQOL by PedsQL 4.0 Generic Core and CF Questionnaire-revised (CFQ-R) prior to US and annually. HRQOL scores were compared by US pattern at baseline (prior to US), between baseline and 1 year and at 5 years. Multivariate analysis of variance (MANOVA) with Hotelling-Lawley trace tested for differences among US groups. RESULTS: Prior to US, among 515 participants and their parents there was no evidence that HTG or NOD US was associated with reduced PedsQL/CFQ-R at baseline. Parents of NOD reported no change in PedsQL/CFQ-R over the next year. Child-report PedsQL/CFQ-R (95 NL, 20 NOD) showed improvement between baseline and year 5 for many scales, including Physical Function. Parents of HMG children reported improved CFQ-R scores related to weight. CONCLUSIONS: Early undiagnosed or pre-symptomatic liver disease had no impact on generic or disease-specific HRQoL, and HRQoL was remarkably stable in children with CF regardless of liver involvement.


Cystic Fibrosis , Liver Diseases , Humans , Child, Preschool , Quality of Life , Prospective Studies , Health Status , Cystic Fibrosis/complications , Cystic Fibrosis/diagnostic imaging , Surveys and Questionnaires , Liver Diseases/etiology , Liver Diseases/complications
5.
Pediatr Radiol ; 52(3): 539-548, 2022 Mar.
Article En | MEDLINE | ID: mdl-34751813

BACKGROUND: Pediatric patients with optic pathway gliomas (OPGs) typically undergo a large number of follow-up MRI brain exams with gadolinium-based contrast media (GBCM), which have been associated with gadolinium tissue retention. Therefore, careful consideration of GBCM use in these children is warranted. OBJECTIVE: To investigate whether GBCM is necessary for OPG MR imaging response assessment using a blinded, non-inferiority, multi-reader study. MATERIALS AND METHODS: We identified children with OPG and either stable disease or change in tumor size on MRI using a regional cancer registry serving the U.S. Pacific Northwest. For each child, the two relevant, consecutive MRI studies were anonymized and standardized into two imaging sets excluding or including GBCM-enhanced images. Exam pairs were compiled from 42 children with isolated OPG (19 with neurofibromatosis type 1), from a population of 106 children with OPG. We included 28 exam pairs in which there was a change in size between exams. Seven pediatric radiologists measured tumor sizes during three blinded sessions, spaced by at least 1 week. The first measuring session excluded GBCM-enhanced sequences; the others did not. The primary endpoint was intra-reader agreement for ≥ 25% change in axial cross-product measurement, using a 12% non-inferiority threshold. RESULTS: Analysis demonstrated an overall 1.2% difference (95% confidence interval, -3.2% to 5.5%) for intra-reader agreement using a non-GBCM-enhanced protocol and background variability. CONCLUSION: A non-GBCM-enhanced protocol was non-inferior to a GBCM-enhanced protocol for assessing change in size of isolated OPGs on follow-up MRI exams.


Gadolinium , Optic Nerve Glioma , Child , Contrast Media , Follow-Up Studies , Humans , Magnetic Resonance Imaging/methods , Optic Nerve Glioma/diagnostic imaging , Retrospective Studies
6.
Pediatr Radiol ; 52(13): 2510-2528, 2022 12.
Article En | MEDLINE | ID: mdl-34734315

Newer-generation CT scanners with ultrawide detectors or dual sources offer millisecond image acquisition times and significantly decreased radiation doses compared to historical cardiac CT and CT angiography. This technology is capable of nearly freezing cardiac and respiratory motion. As a result, CT is increasingly used for diagnosing and monitoring cardiac and vascular abnormalities in the pediatric population. CT is particularly useful in the setting of pulmonary vein evaluation because it offers evaluation of the entire pulmonary venous system and lung parenchyma. In this article we review a spectrum of congenital and acquired pulmonary venous abnormalities, including potential etiologies, CT imaging findings and important factors of preoperative planning. In addition, we discuss optimization of CT techniques for evaluating the pulmonary veins.


Pulmonary Veins , Child , Humans , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/abnormalities , Tomography, X-Ray Computed/methods , Computed Tomography Angiography
7.
Hepatol Commun ; 5(8): 1362-1372, 2021 Aug.
Article En | MEDLINE | ID: mdl-34430781

Methods to identify children with cystic fibrosis (CF) at risk for development of advanced liver disease are lacking. We aim to determine the association between liver stiffness measurement (LSM) by vibration-controlled transient elastography (VCTE) with research ultrasound (US) patterns and conventional hepatic markers as a potential means to follow liver disease progression in children with CF. ELASTIC (Longitudinal Assessment of Transient Elastography in CF) is a nested cohort of 141 patients, ages 7-21, enrolled in the Prediction by US of Risk of Hepatic Cirrhosis in CF (PUSH) Study. We studied the association between LSM with research-grade US patterns (normal [NL], heterogeneous [HTG], homogeneous [HMG], or nodular [NOD]) and conventional hepatic markers. In a subgroup (n = 79), the association between controlled attenuation parameter (CAP) and US pattern was explored. Among 133 subjects undergoing VCTE, NOD participants (n = 26) had a significantly higher median (interquartile range) LSM of 9.1 kPa (6.3, 15.8) versus NL (n = 72, 5.1 kPa [4.2, 7.0]; P < 0.0001), HMG (n = 17, 5.9 kPa [5.2, 7.8]; P = 0.0013), and HTG (n = 18, 6.1 kPa [4.7, 7.0]; P = 0.0008) participants. HMG participants (n = 14) had a significantly higher mean CAP (SD) (270.5 dB/m [61.1]) compared with NL (n = 40, 218.8 dB/m [46.5]; P = 0.0027), HTG (n = 10, 218.1 dB/m [60.7]; P = 0.044), and NOD (n = 15, 222.7 dB/m [56.4]; P = 0.041) participants. LSM had a negative correlation with platelet count (rs =  - 0.28, P = 0.0071) and positive correlation with aspartate aminotransferase-to-platelet ratio index (rs = 0.38, P = 0.0002), Fibrosis-4 index (rs = 0.36, P = 0.0007), gamma-glutamyltransferase (GGT; rs = 0.35, P = 0.0017), GGT-to-platelet ratio (rs = 0.35, P = 0.003), and US spleen size z-score (rs = 0.27, P = 0.0073). Conclusion: VCTE is associated with US patterns and conventional markers in patients with liver disease with CF.

8.
Clin Imaging ; 75: 165-170, 2021 Jul.
Article En | MEDLINE | ID: mdl-33831747

PURPOSE: While full description of pediatric COVID-19 manifestations is evolving, children appear to present less frequently, and often display a less severe disease phenotype. There is correspondingly less data regarding pediatric radiologic findings. To describe the imaging findings of pediatric COVID-19, we evaluated the radiologic imaging of the initial patient cohort identified at our institution. METHODS: In this IRB approved study, all patients at our institution aged 0-21 with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) based on PCR or immunoglobulin testing were identified. Imaging was reviewed by the co-authors and presence of abnormalities determined by consensus. Pre-existing comorbidities and alternative diagnoses were recorded. Rates of each finding were calculated. Findings were compared to published data following review of the available literature. RESULTS: Out of 130 Covid-19 positive patients, 24 patients underwent imaging, including 21 chest radiographs and 4 chest CT scans. Chest x-rays were normal in 33%. Patchy or streaky opacities were the most common radiographic abnormality, each seen in 38% of patients. CT findings included ill-defined or geographic ground glass opacities, dense opacities, septal thickening and crazy paving, and small pleural effusions. Results are similar to those reported in adults. Multiple COVID-19 positive children presented for symptoms due to an additional acute illness, including appendicitis and urinary infection. CONCLUSIONS: Radiologic findings of COVID-19 in pediatric patients range from normal to severe ARDS type appearance. During this ongoing pandemic, these radiographic signs can be useful for the evaluation of disease status and guiding care, particularly in those with comorbidities. PRECIS: Radiologic findings of COVID-19 in pediatric patients are similar to those seen in adults, and may range from normal to severe ARDS type appearance.


COVID-19 , Adult , Child , Cohort Studies , Humans , Lung , Pandemics , SARS-CoV-2 , Tomography, X-Ray Computed
9.
Pediatr Radiol ; 50(10): 1409-1420, 2020 09.
Article En | MEDLINE | ID: mdl-32681235

BACKGROUND: Common cause analysis of hospital safety events that involve radiology can identify opportunities to improve quality of care and patient safety. OBJECTIVE: To study the most frequent system failures as well as key activities and processes identified in safety events in an academic children's hospital that underwent root cause analysis and in which radiology was determined to play a contributing role. MATERIALS AND METHODS: All safety events involving diagnostic or interventional radiology from April 2013 to November 2018, for which the hospital patient safety department conducted root cause analysis, were retrospectively analyzed. Pareto charts were constructed to identify the most frequent modalities, system failure modes, key processes and key activities. RESULTS: In 19 safety events, 64 sequential interactions were attributed to the radiology department by the patient safety department. Five of these safety events were secondary to diagnostic errors. Interventional radiology, radiography and diagnostic fluoroscopy accounted for 89.5% of the modalities in these safety events. Culture and process accounted for 55% of the system failure modes. The three most common key processes involved in these sequential interactions were diagnostic (39.1%) and procedural services (25%), followed by coordinating care and services (18.8%). The two most common key activities were interpreting/analyzing (21.9%) and coordinating activities (15.6%). CONCLUSION: Proposing and implementing solutions based on the analysis of a single safety event may not be a robust strategy for process improvement. Common cause analyses of safety events allow for a more robust understanding of system failures and have the potential to generate more specific process improvement strategies to prevent the reoccurrence of similar errors. Our analysis demonstrated that the most common system failure modes in safety events attributed to radiology were culture and process. However, the generalizability of these findings is limited given our small sample size. Aligning with other children's hospitals to use standard safety event terminology and shared databases will likely lead to greater clarity on radiology's direct and indirect contributions to patient harm.


Diagnostic Errors/statistics & numerical data , Hospitals, Pediatric/standards , Medical Errors/statistics & numerical data , Radiology Department, Hospital/standards , Root Cause Analysis , Safety Management/standards , Humans , Organizational Culture , Patient Safety , Quality Improvement , Retrospective Studies
10.
Top Magn Reson Imaging ; 29(4): 187-195, 2020 Aug.
Article En | MEDLINE | ID: mdl-32541256

Pediatric imaging presents unique challenges related to patient anxiety, cooperation, and safety. Techniques to reduce anxiety and patient motion in adults must often be augmented in pediatrics, because it is always mentioned in the field of pediatrics, children are not miniature adults. This article will review methods that can be considered to improve patient experience and cooperation in imaging studies. Such techniques can range from modifications to the scanner suite, different ways of preparing and interacting with children, collaborating with parents for improved patient care, and technical advances such as accelerated acquisition and motion correction to reduce artifact. Special considerations for specific populations including transgender patients, neonates, and pregnant women undergoing fetal imaging will be described. The unique risks of sedation in children will also be briefly reviewed.


Magnetic Resonance Imaging/methods , Patient Comfort/methods , Patient Compliance , Pediatrics/methods , Adolescent , Child , Child, Preschool , Female , Humans , Infant , Infant, Newborn , Male , Motion
11.
Paediatr Anaesth ; 30(6): 683-690, 2020 06.
Article En | MEDLINE | ID: mdl-32277728

BACKGROUND: Direct laryngoscopy and intubation are often difficult in children with Robin Sequence. Previous research characterizing anatomic airway differences has focused on parameters influencing airway patency; there is a paucity of data pertaining to intubation trajectories and depth. Such information could impact airway management approaches and decrease the incidence of endotracheal tube malpositioning. AIM: The study goal was to examine whether longitudinal airway parameters pertaining to intubation are different in children with Robin Sequence compared with age-matched controls. METHOD: This case-control study compared patients with RS <4 years of age who had computed tomography scans of the head and neck to age- and sex-matched controls. Measurements were made of the nasopharynx, oropharynx, hypopharynx, tongue, hyoid, and the front teeth to vocal cord, nares to vocal cord, and nasion-basion distances. Statistical analysis was performed using multiple ANCOVA models with the categorical predictor of Robin Sequence vs control and potential covariates including subject height/length, weight, and age. RESULTS: Thirty-three patients with Robin Sequence and 33 control subjects were included. After controlling for subject height/length, mean front teeth to vocal cord distance was 1.2 cm longer (95% CI: 0.9 to 1.6 cm, P < .001) and mean nares to vocal cord distance was 0.8 cm longer (95% CI: 0.4 to 1.2 cm, P < .001) in patients with Robin Sequence than in controls. The tongue was positioned on average 0.5 cm higher (95% CI: 0.3 to 0.8, P < .001) and 0.9 cm more posterior (95% CI: 0.6 to 1.0 cm, P < .001) in cases than in controls. Moreover, in patients with Robin Sequence, the hyoid was positioned on average 0.5 cm more inferiorly (95% CI: 0.2 to 0.8 cm, P < .001) and 0.2 cm more posteriorly (95% CI: 0.1 to 0.4 cm, P < .01) than controls. CONCLUSION: In patients with Robin Sequence under 4 years of age, the mean front teeth to vocal cord distance was found to be 1.2 cm longer while the mean nares to vocal cord distance was found to be 0.8 cm longer controlling for subject length. Clinicians should account for these differences when selecting and placing endotracheal tubes, particularly those with a preformed bend.


Larynx , Pierre Robin Syndrome , Case-Control Studies , Child , Humans , Intubation, Intratracheal , Pierre Robin Syndrome/diagnostic imaging , Tomography, X-Ray Computed
12.
J Pediatr ; 219: 62-69.e4, 2020 04.
Article En | MEDLINE | ID: mdl-32061406

OBJECTIVE: To assess if a heterogeneous pattern on research liver ultrasound examination can identify children at risk for advanced cystic fibrosis (CF) liver disease. STUDY DESIGN: Planned 4-year interim analysis of a 9-year multicenter, case-controlled cohort study (Prospective Study of Ultrasound to Predict Hepatic Cirrhosis in CF). Children with pancreatic insufficient CF aged 3-12 years without known cirrhosis, Burkholderia species infection, or short bowel syndrome underwent a screening research ultrasound examination. Participants with a heterogeneous liver ultrasound pattern were matched (by age, Pseudomonas infection status, and center) 1:2 with participants with a normal pattern. Clinical status and laboratory data were obtained annually and research ultrasound examinations biannually. The primary end point was the development of a nodular research ultrasound pattern, a surrogate for advanced CF liver disease. RESULTS: There were 722 participants who underwent screening research ultrasound examination, of which 65 were heterogeneous liver ultrasound pattern and 592 normal liver ultrasound pattern. The final cohort included 55 participants with a heterogeneous liver ultrasound pattern and 116 participants with a normal liver ultrasound pattern. All participants with at least 1 follow-up research ultrasound were included. There were no differences in age or sex between groups at entry. Alanine aminotransferase (42 ± 22 U/L vs 32 ± 19 U/L; P = .0033), gamma glutamyl transpeptidase (36 ± 34 U/L vs 15 ± 8 U/L; P < .001), and aspartate aminotransferase to platelet ratio index (0.7 ± 0.5 vs 0.4 ± 0.2; P < .0001) were higher in participants with a heterogeneous liver ultrasound pattern compared with participants with a normal liver ultrasound pattern. Participants with a heterogeneous liver ultrasound pattern had a 9.1-fold increased incidence (95% CI, 2.7-30.8; P = .0004) of nodular pattern vs a normal liver ultrasound pattern (23% in heterogeneous liver ultrasound pattern vs 2.6% in normal liver ultrasound pattern). CONCLUSIONS: Research liver ultrasound examinations can identify children with CF at increased risk for developing advanced CF liver disease.


Cystic Fibrosis/complications , Liver Diseases/etiology , Liver/pathology , Case-Control Studies , Child , Child, Preschool , Female , Humans , Liver/diagnostic imaging , Liver Diseases/diagnosis , Male , Prospective Studies , Risk Assessment , Ultrasonography
13.
AJR Am J Roentgenol ; 211(5): 971-977, 2018 11.
Article En | MEDLINE | ID: mdl-30106619

OBJECTIVE: The goal of this study is to evaluate the perceptions held by full- and part-time academic pediatric radiologists with regard to the value of part-time radiologists, as well as the value placed on the work of part-time colleagues by their departments and institutions. MATERIALS AND METHODS: Two online surveys were distributed to full- and part-time pediatric radiologists via the Society for Pediatric Radiology e-mail list serve. Survey questions evaluated demographic data of both full- and part-time radiologists, as well as the perceptions each group has of part-time employment. RESULTS: Part-time radiologists reported significantly greater work-life balance than did their full-time counterparts and were less likely to report job dissatisfaction. Full- and part-time faculty have comparable levels of perceived departmental contributions. Part-time faculty were more likely to be younger women, early in their careers, and older men nearing retirement. CONCLUSION: Part-time employment provides perceived benefits of increased work-life balance and job satisfaction and is viewed favorably by both full- and part-time radiologists in academic settings.


Employment/statistics & numerical data , Job Satisfaction , Pediatricians , Radiologists , Workload/statistics & numerical data , Adult , Aged , Female , Humans , Male , Middle Aged , Surveys and Questionnaires , Work-Life Balance
14.
Pediatr Radiol ; 48(10): 1472-1484, 2018 09.
Article En | MEDLINE | ID: mdl-29789890

BACKGROUND: Pediatric optic pathway gliomas are typically indolent but have a variable clinical course. Treatment is dictated by symptoms and changes on contrast-enhanced MRI examinations. Gadolinium retention in children has motivated parsimonious use of gadolinium-based contrast agents. OBJECTIVES: To determine surveillance MR factors that motivate changes in tumor-directed therapies and extrapolate cost-efficacy of a non-contrast follow-up protocol. MATERIALS AND METHODS: Using an imaging database search we identified children with isolated optic pathway gliomas and ≥3 follow-up contrast-enhanced MRIs. We reviewed medical records and imaging for: (1) coincident changes on contrast-enhanced MRI and tumor-directed therapy, (2) demographics and duration of follow-up, (3) motivations for intervention, (4) assessment of gadolinium-based contrast agents' utility and (5) health care utilization data. We assessed cost impact in terms of relative value unit (RVU) burden. RESULTS: We included 17 neurofibromatosis type 1 (NF1) and 21 non-NF1 patients who underwent a median 16.9 and 24.3 cumulative contrast-enhanced MR exams over 7.7 years and 8.1 years of follow-up, respectively. Eight children (one with NF1) had intervention based on contrast-enhanced MR findings alone. For these eight, increased tumor size was the only common feature, and it was apparent on non-contrast T2 sequences. For the median patient, a non-contrast follow-up protocol could result in 15.9 (NF1) and 23.3 (non-NF1) fewer gadolinium-based contrast agent administrations, and a 39% lower yearly RVU burden. CONCLUSION: Pediatric patients with isolated optic pathway gliomas undergo a large number of routine contrast-enhanced MR follow-up exams. Gadolinium might not be needed for these exams to inform management decisions. Secondary benefits of a non-contrast follow-up protocol include decreased cost and risk to the patient.


Contrast Media/administration & dosage , Gadolinium/administration & dosage , Magnetic Resonance Imaging/methods , Optic Nerve Glioma/diagnostic imaging , Child , Child, Preschool , Female , Humans , Infant , Male , Neurofibromatosis 1/complications
15.
AJR Am J Roentgenol ; 209(2): 417-429, 2017 Aug.
Article En | MEDLINE | ID: mdl-28590770

OBJECTIVE: Interpretation of abdominal radiographs of children benefits from a firm knowledge of the congenital anomalies and pathologies unique to this patient population, leveraged by a systematic approach. Interpretive errors place the patients and their families at risk for a delay in diagnosis, unnecessary additional imaging, a potential increase in the radiation burden, and possible psychologic trauma. CONCLUSION: In this article, we describe the common and uncommon potential pitfalls in pediatric abdominal radiography, using several of our own interpretive errors as a framework while providing teaching points to help avoid these mistakes.


Diagnostic Errors , Radiography, Abdominal , Adolescent , Child , Humans , Risk Factors
16.
AJR Am J Roentgenol ; 207(4): 903-911, 2016 Oct.
Article En | MEDLINE | ID: mdl-27490235

OBJECTIVE: Radiographic imaging of the pediatric chest presents several unique challenges and nuances, stemming from congenital variants and pathologic processes specific to this population. Errors in interpretation may lead to inappropriate further imaging, incurring additional radiation exposure and cost, as well as psychologic effects on the patients and their families. CONCLUSION: Here, we aim to highlight some common and less common pitfalls in pediatric chest radiography, as well as some tools for avoiding potential mistakes.

18.
Curr Probl Diagn Radiol ; 45(2): 139-48, 2016.
Article En | MEDLINE | ID: mdl-26489791

The purpose of this article is to illustrate types of diagnostic errors and feedback given to radiologists, using cases to support and clarify these categories. A comment-enhanced peer review system may be leveraged to generate a comprehensive feedback categorization scheme. These include errors of observation, errors of interpretation, inadequate patient data gathering, errors of communication, interobserver variability, informational feedback, and compliments. Much of this feedback is captured through comments associated with interpretative agreements.


Pediatrics/standards , Peer Review, Health Care/standards , Radiology Department, Hospital/standards , Clinical Competence/standards , Diagnostic Errors/prevention & control , Humans , Quality Assurance, Health Care , United States
19.
Pediatr Radiol ; 45(12): 1845-55; quiz 1842-4, 2015 Nov.
Article En | MEDLINE | ID: mdl-26209957

Imaging is crucial in expediting the diagnosis and guiding definitive therapy in children with ovarian torsion. This article reviews the multimodality spectrum of imaging findings in pediatric ovarian torsion, focusing primarily on US appearances. We describe predisposing conditions that can lead to torsion, the pathological basis of the radiologic findings in ovarian torsion, and the common diagnostic pitfalls.


Ovarian Diseases/diagnostic imaging , Torsion Abnormality/diagnostic imaging , Adolescent , Child , Diagnosis, Differential , Female , Humans , Magnetic Resonance Imaging , Ovarian Diseases/pathology , Ovary/diagnostic imaging , Ovary/pathology , Tomography, X-Ray Computed , Torsion Abnormality/pathology , Ultrasonography
20.
Paediatr Anaesth ; 25(9): 936-42, 2015 Sep.
Article En | MEDLINE | ID: mdl-26033678

BACKGROUND: Knowledge of the normal nares-to-carina (NC) distance might prevent accidental bronchial intubation and be helpful when designing preformed endotracheal tubes (ETT). OBJECTIVE: The aim was to measure NC distance and to examine whether a height/length-based 'modified Morgan formula' would give useful guidance for nasotracheal ETT depth positioning. METHODS: Two groups were studied. A younger group consisted of nasally intubated postoperative patients. In these, NC distance was obtained as the sum of ETT length and the distance from the ETT tip to the carina, as measured from an anteroposterior chest X-ray. An older group consisted of children who had undergone computerized tomography (CT) examination including head, neck, and chest. In these, NC was measured directly from the CT image. The modified Morgan formula was derived from the NC vs height/length relationship. RESULTS: Nares-to-carina distance was best predicted by a linear equation based on patient height. The equation in the younger group (1 day-8 years, n = 57) was: NC (cm) = 0.14 × height + 5.8, R(2) = 0.90, and in the older group (2.1-20 years, n = 45): NC (cm) = 0.15 × height + 3.4, R(2) = 0.93. The equation for the groups combined (n = 102) was: NC (cm) = 0.14 × height + 6.2, R(2) = 0.97. Based on the latter equation, a modified Morgan formula was identified as: ETT position at nares in cm = 0.12 × height + 5. If the ETT had been placed as calculated by this formula, the ETT tip would have been at 85 + 5% (mean ± sd) of NC distance, and the ETT tip-to-carina distance would have been 3.1 ± 1.1 cm (range 0-6.6). Bronchial intubation would not have occurred in any child, but a comparison to tracheal length measurements indicates that ETT tip position could be too proximal in some children. CONCLUSION: The study confirms previous reports: NC distance can be well predicted from height/length. A modified Morgan formula might decrease the risk for accidental endobronchial intubation in infants and children, but ETT position need to be confirmed by auscultation or other verification.


Body Height , Body Weights and Measures/methods , Intubation, Intratracheal , Adolescent , Adult , Child , Child, Preschool , Female , Humans , Infant , Infant, Newborn , Male , Neck/diagnostic imaging , Nose , Radiography, Thoracic , Tomography, X-Ray Computed , Young Adult
...