Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Med Biol ; 60(22): 8791-807, 2015 Nov 21.
Article in English | MEDLINE | ID: mdl-26528908

ABSTRACT

Parallel-hole SPECT collimators have traditionally been manufactured by stacking sheets of lead foil or by casting. These techniques significantly restrict our options in terms of collimator geometry. However, recent developments in metal additive manufacturing are making novel collimator designs possible, giving rise to new opportunities in SPECT imaging. In this paper we propose an innovative type of collimator for stationary SPECT, using parallel-holes whose collimation direction depends on their axial position. Its main advantage compared to current stationary SPECT systems (which are based on pinholes) is that, using only axial bed translations, we can achieve complete angular sampling of an increased portion of the transaxial area of the collimator bore. This allows the system to be much more compact than current stationary SPECT systems that image objects of the same size. We describe three possible designs, for full-body, brain and small-animal imaging, respectively, and test their feasibility using simulations. The system modeling method is validated against realistic Monte Carlo simulations, and then used in the evaluation of the systems' performances and reconstructions. The simulations show that the system is able to reconstruct objects occupying the predicted field of view ([Formula: see text] of the transaxial area of the bore) without sampling artifacts. In particular, we perform reconstructions from noisy projection data obtained for an activity and scanning time similar to standard protocols for the three applications, and the resulting images indicate the possibility of using the proposed systems in practice.


Subject(s)
Brain/diagnostic imaging , Image Processing, Computer-Assisted/methods , Models, Theoretical , Phantoms, Imaging , Tomography, Emission-Computed, Single-Photon/methods , Whole Body Imaging/methods , Animals , Artifacts , Feasibility Studies , Humans , Monte Carlo Method
2.
IEEE Trans Med Imaging ; 34(9): 1830-42, 2015 Sep.
Article in English | MEDLINE | ID: mdl-25769150

ABSTRACT

The accurate determination of the local impulse response and the covariance in voxels from penalized maximum likelihood reconstructed images requires performing reconstructions from many noise realizations of the projection data. As this is usually a very time-consuming process, efficient analytical approximations based on the Fisher information matrix (FIM) have been extensively used in PET and SPECT to estimate these quantities. For 3D imaging, however, additional approximations need to be made to the FIM in order to speed up the calculations. The most common approach is to use the local shift-invariant (LSI) approximation of the FIM, but this assumes specific conditions which are not always necessarily valid. In this paper we take a single-pinhole SPECT system and compare the accuracy of the LSI approximation against two other methods that have been more recently put forward: the non-uniform object-space pixelation (NUOP) and the subsampled FIM. These methods do not assume such restrictive conditions while still increasing the speed of the calculations considerably. Our results indicate that in pinhole SPECT the NUOP and subsampled FIM approaches could be more reliable than the LSI approximation, especially when a high accuracy is required.


Subject(s)
Image Processing, Computer-Assisted/methods , Tomography, Emission-Computed, Single-Photon/methods , Algorithms , Phantoms, Imaging
3.
Phys Med Biol ; 58(4): 859-85, 2013 Feb 21.
Article in English | MEDLINE | ID: mdl-23337658

ABSTRACT

In single-photon emission computed tomography (SPECT), multi-pinhole collimation is often employed nowadays. Most multi-pinhole collimators avoid overlap (multiplexing) of the projections on the detector. This can be done by using additional shielding or by spacing the pinholes far enough apart. Using additional shielding has the drawback that it increases weight, design complexity and cost. Spacing the pinholes far enough apart results in sub-optimal detector usage, the valuable detector area is not entirely used. This is due to the circular projections of pinholes on the detector; these ellipses can not be tiled with high detector coverage. To overcome this we designed a new pinhole geometry, the lofthole, that has a rectangular projection on the detector. The lofthole has a circular aperture and a rectangular entrance/exit opening. Sensitivity formulae have been derived for pinholes and loftholes. These formulae take the penumbra effect into account; the proposed formulae do not take penetration into account. The derived formulae are valid for geometries where the field-of-view and the sensitivity of the aperture are solely limited by the exit window. A flood map measurement was performed to compare the rectangular projection of a lofthole with the circular projection of a pinhole. Finally, measurements were done to compare the amount of penetration of pinholes with the amount of penetration of a lofthole. A square lofthole collimator has less penetration than a knife-edge pinhole collimator that irradiates the same rectangular detector area with full coverage. A multi-lofthole collimator allows high detector coverage without using additional shielding. An additional advantage is the lower amount of penetration.


Subject(s)
Tomography, Emission-Computed, Single-Photon/instrumentation , Animals , Computer Simulation , Equipment Design , Image Processing, Computer-Assisted/methods , Models, Theoretical , Tomography, Emission-Computed, Single-Photon/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...