Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Exp Orthop ; 10(1): 123, 2023 Nov 28.
Article in English | MEDLINE | ID: mdl-38015319

ABSTRACT

PURPOSE: To evaluate the accuracy and reproducibility of a patient-specific, customized individually made (CIM) total knee replacement (TKR) using the ORIGIN® prosthesis. METHODS: This was a prospective study conducted at a University Hospital from January 15, 2019, to April 30, 2021. The study included patients planned for an ORIGIN® CIM TKR procedure. Exclusion criteria included revision surgery, severe deformity, stiffness, or laxity. Evaluations were carried out using computed tomography scans performed 8 weeks preoperatively and 6 weeks postoperatively. The primary outcome measurements were the preoperative, planned, and postoperative CT scan alignment measurements including the Hip-Knee-Ankle (HKA) angle, mechanical Medial Distal Femoral articular surface Angle (mMDFA, distal alpha angle), Posterior Distal femoral articular surface angle (PDFA, posterior alpha angle), mechanical Medial Proximal Tibial articular surface Angle (mMPTA, beta angle) and posterior proximal tibial angle (PPTA). Secondary outcomes included the accuracy of implant positioning with percentage of outliers at 2° and 3° RESULTS: The study encompassed 51 knees from 50 patients with mean age of 68.1 (SD = 8.89). The overall HKA angle deviated by -0.93° [95% CI: -1.45; -0.43], and the PDFA angle by -0.61° [95% CI: -1.07; -0.15], while the mMPTA exceeded planned values by 1.00° [95% CI: 0.57; 1.43]. The 3° outliers rate ranged from 3.9% for the mMPTA to 7.8% for the HKA alignment, with no outliers in mMDFA and PPTA. Similarly, the 2° outliers rate ranged from 15.7% for both the PDFA angle and mMPTA to 19.6% for the HKA alignment. The Bland-Altman plots further emphasized the precision of planned and post-operative angles across all measurements. CONCLUSION: The CIM TKR showed high accuracy and reproducibility, closely matching preoperative planning. The weakest accuracy at 3°-outliers is in the reproduction of the HKA alignment at 92.2% (range for all angle: 92.2-100%). Similarly, the weakest accuracy at 2°-outliers is in the reproduction of the HKA alignment at 80.4% (range for all angles: 80.4-92.2%).

2.
Arthrosc Tech ; 10(4): e1131-e1135, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33981561

ABSTRACT

Considering shoulder arthroscopy, lateral decubitus and beach chair are the 2 main employed positionings of the patient. Each include advantages and disadvantages. In our center, we perform all shoulder arthroscopy with the patient in supine position. The aim of this work is to present a stepwise approach of the accomplishment of a rotator cuff repair in supine position. Some specific technical notes are given to provide as much information as possible to help orthopaedic surgeons wishing to perform shoulder cuff repair in this position.

SELECTION OF CITATIONS
SEARCH DETAIL
...