Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 585
Filter
1.
Heart Rhythm ; 2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38848862

ABSTRACT

BACKGROUND: In patients with a history of stroke or those at high risk for developing stroke, a continuous rhythm monitoring strategy using an implantable loop recorder (ILR) is often performed to screen for atrial fibrillation (AF). OBJECTIVES: The purpose of this study was to perform a systematic review (MEDLINE and EMBASE) including randomized controlled trials comparing ILR-based continuous rhythm monitoring vs usual care in patients with a history of stroke or patients at high risk for developing stroke. METHODS: A meta-analysis was performed, and aggregate risk ratio (RR) and risk difference (RD) with 95% confidence interval (CI) were calculated. RESULTS: Four randomized controlled trials with 7237 patients (ILR 2114, non-ILR 5123) were included. ILR vs non-ILR was associated with increased detection of incident AF (RR 3.88; 95% CI 2.23-6.75; P <.00001; number needed to treat [NNT] = 7.7; I2 = 61%), increased appropriate initiation of anticoagulation (RR 2.29; 95% CI 2.07-2.55; P <.00001; NNT = 6.7; I2 = 0), and a 25% lower risk of developing stroke (RR 0.75; 95% CI 0.59-0.95]; P = .02; NNT = 100; I2 = 0%). In patients with history of stroke there was no difference in the risk of developing incident stroke (RR 0.83; 95% CI 0.61-1.14]; P = .25; I2 = 0%). CONCLUSION: Our meta-analysis showed that screening for AF with ILR is associated with increased detection of AF and increased initiation of appropriate anticoagulation therapy in patients with a history of stroke or those with risk factors for stroke. The benefit of stroke risk reduction with ILR remains unclear, and future studies focused on the inclusion of patients without a history of stroke are needed to elucidate this uncertainty.

2.
Article in English | MEDLINE | ID: mdl-38842977

ABSTRACT

BACKGROUND: New-onset atrial fibrillation (NOAF) occurs in 5% to 15% of patients who undergo transfemoral transcatheter aortic valve replacement (TAVR). Cardiac imaging has been underutilized to predict NOAF following TAVR. OBJECTIVES: The objective of this analysis was to compare and assess standard, manual echocardiographic and cardiac computed tomography (cCT) measurements as well as machine learning-derived cCT measurements of left atrial volume index and epicardial adipose tissue as risk factors for NOAF following TAVR. METHODS: The study included 1,385 patients undergoing elective, transfemoral TAVR for severe, symptomatic aortic stenosis. Each patient had standard and machine learning-derived measurements of left atrial volume and epicardial adipose tissue from cardiac computed tomography. The outcome of interest was NOAF within 30 days following TAVR. We used a 2-step statistical model including random forest for variable importance ranking, followed by multivariable logistic regression for predictors of highest importance. Model discrimination was assessed by using the C-statistic to compare the performance of the models with and without imaging. RESULTS: Forty-seven (5.0%) of 935 patients without pre-existing atrial fibrillation (AF) experienced NOAF. Patients with pre-existing AF had the largest left atrial volume index at 76.3 ± 28.6 cm3/m2 followed by NOAF at 68.1 ± 26.6 cm3/m2 and then no AF at 57.0 ± 21.7 cm3/m2 (P < 0.001). Multivariable regression identified the following risk factors in association with NOAF: left atrial volume index ≥76 cm2 (OR: 2.538 [95% CI: 1.165-5.531]; P = 0.0191), body mass index <22 kg/m2 (OR: 4.064 [95% CI: 1.500-11.008]; P = 0.0058), EATv (OR: 1.007 [95% CI: 1.000-1.014]; P = 0.043), aortic annulus area ≥659 mm2 (OR: 6.621 [95% CI: 1.849-23.708]; P = 0.004), and sinotubular junction diameter ≥35 mm (OR: 3.891 [95% CI: 1.040-14.552]; P = 0.0435). The C-statistic of the model was 0.737, compared with 0.646 in a model that excluded imaging variables. CONCLUSIONS: Underlying cardiac structural differences derived from cardiac imaging may be useful in predicting NOAF following transfemoral TAVR, independent of other clinical risk factors.

3.
Circ Cardiovasc Interv ; 17(6): e013466, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38889251

ABSTRACT

BACKGROUND: Procedure volumes are associated with outcomes for many cardiovascular procedures, leading to guidelines on minimum volume thresholds for certain procedures; however, the volume-outcome relationship with left atrial appendage occlusion is poorly understood. As such, we sought to determine the relationship between hospital and physician volume and WATCHMAN left atrial appendage occlusion procedural success overall and with the new generation WATCHMAN FLX device. METHODS: We performed an analysis of WATCHMAN procedures (January 2019 to October 2021) from the National Cardiovascular Data Registry LAAO Registry. Three-level hierarchical generalized linear models were used to assess the adjusted relationship between procedure volume and procedural success (device released with peridevice leak <5 mm, no in-hospital major adverse events). RESULTS: Among 87 480 patients (76.2±8.0 years; 58.8% men; mean CHA2DS2-VASc score, 4.8±1.5) from 693 hospitals, the procedural success rate was 94.2%. With hospital volume Q4 (greatest volume) as the reference, the likelihood of procedural success was significantly less among Q1 (odds ratio [OR], 0.66 [CI, 0.57-0.77]) and Q2 (OR, 0.78 [CI, 0.69-0.90]) but not Q3 (OR, 0.95 [CI, 0.84-1.07]). With physician volume Q4 (greatest volume) as the reference, the likelihood of procedural success was significantly less among Q1 (OR, 0.72 [CI, 0.63-0.82]), Q2 (OR, 0.79 [CI, 0.71-0.89]), and Q3 (OR, 0.88 [CI, 0.79-0.97]). Among WATCHMAN FLX procedures, there was attenuation of the volume-outcome relationships, with statistically significant but modest absolute differences of only ≈1% across volume quartiles. CONCLUSIONS: In this contemporary national analysis, greater hospital and physician WATCHMAN volumes were associated with increased procedure success. The WATCHMAN FLX transition was associated with increased procedural success and less heterogeneity in outcomes across volume quartiles. These findings indicate the importance of understanding the volume-outcome relationship for individual left atrial appendage occlusion devices.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Cardiac Catheterization , Hospitals, High-Volume , Hospitals, Low-Volume , Registries , Humans , Atrial Appendage/physiopathology , Female , Male , Aged , Treatment Outcome , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Atrial Fibrillation/surgery , Aged, 80 and over , United States , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Risk Factors , Risk Assessment , Time Factors , Stroke/etiology , Stroke/prevention & control , Atrial Function, Left
4.
Heart Rhythm ; 2024 Jun 13.
Article in English | MEDLINE | ID: mdl-38878939

ABSTRACT

BACKGROUND: Advances in leadless pacemaker technology have enabled accelerometer-based atrioventricular (AV) synchronous pacing by sensing atrial mechanical contraction. OBJECTIVES: To report performance of the Micra AV leadless pacemaker from the worldwide Micra AV post-approval registry (PAR) through 12-months. METHODS: The Micra AV PAR is a prospective single-arm observational registry designed to assess safety and effectiveness of Micra AV in a real-world setting. For the present interim analysis, major complications and system revisions through 12-months were summarized and compared to a historical cohort of 2,667 transvenous dual-chamber pacing patients. RESULTS: The device was successfully implanted in 796 of 801 patients (99.4%) at 97 centers in 19 countries. Micra AV patients were older (74.1 vs. 71.1 years, P<0.0001) with a higher incidence of renal disease (22.3% vs. 9.8%, P<0.0001) compared to transvenous dual-chamber patients. Through 12-months, the major complication rate was 3.7% in Micra AV patients compared to 8.8% in transvenous dual-chamber patients (hazard ratio [HR]: 0.42, 95% confidence interval [CI]: 0.28-0.61; P<0.001). The system revision rate was 1.5% in Micra AV patients compared to 5.5% for transvenous dual-chamber patients (HR: 0.25, 95% CI: 0.13-0.47; P<0.001); this reduction was largely driven by the absence of lead dislodgements requiring revision. Median AV synchrony index was 79.4% (IQR:65.2%-86.4%) among patients paced >90%. CONCLUSIONS: The Micra AV leadless pacemaker was implanted with a high rate of success in patients with multiple co-morbidities, with a significantly lower rate of complications and system revisions through 12-months compared to a historical cohort of patients with transvenous dual-chamber pacemakers.

7.
J Am Heart Assoc ; 13(9): e030679, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38700039

ABSTRACT

BACKGROUND: Obstructive sleep apnea (OSA) contributes to the generation, recurrence, and perpetuation of atrial fibrillation, and it is associated with worse outcomes. Little is known about the economic impact of OSA therapy in atrial fibrillation. This retrospective cohort study assessed the impact of positive airway pressure (PAP) therapy adherence on health care resource use and costs in patients with OSA and atrial fibrillation. METHODS AND RESULTS: Insurance claims data for ≥1 year before sleep testing and 2 years after device setup were linked with objective PAP therapy use data. PAP adherence was defined from an extension of the US Medicare 90-day definition. Inverse probability of treatment weighting was used to create covariate-balanced PAP adherence groups to mitigate confounding. Of 5867 patients (32% women; mean age, 62.7 years), 41% were adherent, 38% were intermediate, and 21% were nonadherent. Mean±SD number of all-cause emergency department visits (0.61±1.21 versus 0.77±1.55 [P=0.023] versus 0.95±1.90 [P<0.001]), all-cause hospitalizations (0.19±0.69 versus 0.24±0.72 [P=0.002] versus 0.34±1.16 [P<0.001]), and cardiac-related hospitalizations (0.06±0.26 versus 0.09±0.41 [P=0.023] versus 0.10±0.44 [P=0.004]) were significantly lower in adherent versus intermediate and nonadherent patients, as were all-cause inpatient costs ($2200±$8054 versus $3274±$12 065 [P=0.002] versus $4483±$16 499 [P<0.001]). All-cause emergency department costs were significantly lower in adherent and intermediate versus nonadherent patients ($499±$1229 and $563±$1292 versus $691±$1652 [P<0.001 and P=0.002], respectively). CONCLUSIONS: These data suggest clinical and economic benefits of PAP therapy in patients with concomitant OSA and atrial fibrillation. This supports the value of diagnosing and managing OSA and highlights the need for strategies to enhance PAP adherence in this population.


Subject(s)
Atrial Fibrillation , Continuous Positive Airway Pressure , Sleep Apnea, Obstructive , Humans , Female , Atrial Fibrillation/therapy , Atrial Fibrillation/economics , Atrial Fibrillation/epidemiology , Atrial Fibrillation/diagnosis , Male , Middle Aged , Retrospective Studies , Aged , Sleep Apnea, Obstructive/therapy , Sleep Apnea, Obstructive/economics , Sleep Apnea, Obstructive/epidemiology , Continuous Positive Airway Pressure/economics , United States/epidemiology , Health Resources/statistics & numerical data , Health Resources/economics , Health Care Costs/statistics & numerical data , Hospitalization/economics , Hospitalization/statistics & numerical data , Patient Compliance/statistics & numerical data , Treatment Outcome
8.
J Am Heart Assoc ; 13(11): e028951, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38780169

ABSTRACT

BACKGROUND: Days alive out of hospital (DAOH) is an objective and patient-centered net benefit end point. There are no assessments of DAOH in clinical trials of interventions for atrial fibrillation (AF), and it is not known whether this end point is of clinical utility in these populations. METHODS AND RESULTS: ROCKET AF (Rivaroxaban Once Daily Oral Direct Factor Xa Inhibition Compared With Vitamin K Antagonism for Prevention of Stroke and Embolism Trial in Atrial Fibrillation) was an international double-blind, double-dummy randomized clinical trial that compared rivaroxaban with warfarin in patients with atrial fibrillation at increased risk for stroke. We assessed DAOH using investigator-reported event data for up to 12 months after randomization in ROCKET AF. We assessed DAOH overall, by treatment group, and by subgroup, including age, sex, and comorbidities, using Poisson regression. The mean±SD number of days dead was 7.3±41.2, days hospitalized was 1.2±7.2, and mean DAOH was 350.7±56.2, with notable left skew. Patients with comorbidities had fewer DAOH overall. There were no differences in DAOH by treatment arm, with mean DAOH of 350.6±56.5 for those randomized to rivaroxaban and 350.7±55.8 for those randomized to warfarin (P=0.86). A sensitivity analysis found no difference in DAOH not disabled with rivaroxaban versus warfarin (DAOH not disabled, 349.2±59.5 days and 349.1 days±59.3 days, respectively, P=0.88). CONCLUSIONS: DAOH did not identify a treatment difference between patients randomized to rivaroxaban versus warfarin. This may be driven in part by the low overall event rates in atrial fibrillation anticoagulation trials, which leads to substantial left skew in measures of DAOH.


Subject(s)
Anticoagulants , Atrial Fibrillation , Factor Xa Inhibitors , Rivaroxaban , Stroke , Warfarin , Humans , Atrial Fibrillation/drug therapy , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Rivaroxaban/therapeutic use , Rivaroxaban/administration & dosage , Female , Male , Stroke/prevention & control , Stroke/etiology , Stroke/epidemiology , Aged , Warfarin/therapeutic use , Factor Xa Inhibitors/therapeutic use , Factor Xa Inhibitors/administration & dosage , Anticoagulants/therapeutic use , Anticoagulants/administration & dosage , Double-Blind Method , Middle Aged , Time Factors , Treatment Outcome , Morpholines/therapeutic use , Thiophenes/therapeutic use , Aged, 80 and over
9.
Heart Rhythm ; 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38597857

ABSTRACT

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society.

10.
JACC Clin Electrophysiol ; 10(5): 930-940, 2024 May.
Article in English | MEDLINE | ID: mdl-38661602

ABSTRACT

BACKGROUND: Postoperative atrial fibrillation (POAF) is associated with increased morbidity and mortality. Epicardial injection of botulinum toxin may suppress POAF. OBJECTIVES: This study sought to assess the safety and efficacy of AGN-151607 for the prevention of POAF after cardiac surgery. METHODS: This phase 2, randomized, placebo-controlled trial assessed the safety and efficacy of AGN-151607, 125 U and 250 U vs placebo (1:1:1), for the prevention of POAF after cardiac surgery. Randomization was stratified by age (<65, ≥65 years) and type of surgery (nonvalvular/valve surgery). The primary endpoint was the occurrence of continuous AF ≥30 seconds. RESULTS: Among 312 modified intention-to-treat participants (placebo, n = 102; 125 U, n = 104; and 250 U, n = 106), the mean age was 66.9 ± 6.8 years; 17% were female; and 64% had coronary artery bypass graft (CABG) only, 12% had CABG + valve, and 24% had valve surgery. The primary endpoint occurred in 46.1% of the placebo group, 36.5% of the 125-U group (relative risk [RR] vs placebo: 0.80; 95% CI: 0.58-1.10; P = 0.16), and 47.2% of the 250-U group (RR vs placebo: 1.04; 95% CI: 0.79-1.37; P = 0.78). The primary endpoint was reduced in the 125-U group in those ≥65 years of age (RR: 0.64; 95% CI: 0.43-0.94; P = 0.02) with a greater reduction in CABG-only participants ≥65 years of age (RR: 0.49; 95% CI: 0.27-0.87; P = 0.01). Rehospitalization and rates of adverse events were similar across the 3 groups. CONCLUSIONS: There were no significant differences in the rate of POAF with either dose compared with placebo; however, there was a lower rate of POAF in participants ≥65 years undergoing CABG only and receiving 125 U of AGN-151607. These hypothesis-generating findings require investigation in a larger, adequately powered randomized clinical trial. (Botulinum Toxin Type A [AGN-151607] for the Prevention of Post-operative Atrial Fibrillation in Adult Participants Undergoing Open-chest Cardiac Surgery [NOVA]; NCT03779841); A Phase 2, Multi-Center, Randomized, Double-Blind, Placebo-Controlled, Dose Ranging Study to Evaluate the Efficacy and Safety of Botulinum Toxin Type A [AGN 151607] Injections into the Epicardial Fat Pads to Prevent Post-Operative Atrial Fibrillation in Patients Undergoing Open-Chest Cardiac Surgery; 2017-004399-68).


Subject(s)
Atrial Fibrillation , Botulinum Toxins, Type A , Postoperative Complications , Humans , Atrial Fibrillation/prevention & control , Female , Male , Aged , Botulinum Toxins, Type A/therapeutic use , Botulinum Toxins, Type A/administration & dosage , Middle Aged , Postoperative Complications/prevention & control , Double-Blind Method , Cardiac Surgical Procedures/adverse effects , Treatment Outcome , Coronary Artery Bypass/adverse effects
11.
Article in English | MEDLINE | ID: mdl-38609733

ABSTRACT

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society (HRS), the Asia Pacific HRS, and the Latin American HRS.

12.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38587017

ABSTRACT

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Latin America , Treatment Outcome , Catheters , Asia , Catheter Ablation/adverse effects , Catheter Ablation/methods
13.
Circ Arrhythm Electrophysiol ; 17(5): e012697, 2024 May.
Article in English | MEDLINE | ID: mdl-38629286

ABSTRACT

BACKGROUND: Clinically detected atrial fibrillation (AF) is associated with a significant increase in mortality and other adverse cardiovascular events. Since the advent of effective methods for AF rhythm control, investigators have attempted to determine how much these adverse prognostic AF effects could be mitigated by the restoration of sinus rhythm (SR) and whether the method used mattered. METHODS: The CABANA trial (Catheter Ablation versus Antiarrhythmic Drug Therapy for Atrial Fibrillation) randomized 2204 AF patients to ablation versus drug therapy, of which 1240 patients were monitored in follow-up using the CABANA ECG rhythm monitoring system. To assess the prognostic benefits of SR, we performed a prespecified analysis using Cox survival modeling with heart rhythm as a time-dependent variable and randomized treatment group as a stratification factor. RESULTS: In the 1240 patient study cohort, 883 (71.2%) had documented AF at some point during their postblanking follow-up. Among the 883 patients, 671 (76.0%) experienced AF within the first year of postblanking follow-up, and 212 (24.0%) experienced their first AF after ≥1 year of postblanking follow-up. The primary CABANA end point (death, disabling stroke, serious bleeding, or cardiac arrest) occurred in 95 (10.8%) of the 883 patients with documented AF and in 29 (8.1%) of the 357 patients with no AF recorded during follow-up. In multivariable time-dependent analysis, the presence of SR (compared with non-SR) was associated with a significantly reduced risk of the primary end point (adjusted hazard ratio, 0.57 [95% CI, 0.38-0.85]; P=0.006; independent of treatment strategy [ablation versus drugs]). Corresponding results for all-cause mortality were adjusted hazard ratio of 0.59 [95% CI, 0.35-1.01]; P=0.053). CONCLUSIONS: In patients in the CABANA trial with detailed long-term rhythm follow-up, increased time in SR was associated with a clinically consequential decrease in mortality and other adverse prognostic events. The predictive value of SR was independent of the therapeutic approach responsible for reducing the burden of detectable AF. REGISTRATION: URL: https://clinicaltrials.gov; Unique Identifier: NCT00911508.


Subject(s)
Anti-Arrhythmia Agents , Atrial Fibrillation , Catheter Ablation , Heart Rate , Humans , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Atrial Fibrillation/mortality , Atrial Fibrillation/therapy , Male , Female , Anti-Arrhythmia Agents/therapeutic use , Middle Aged , Aged , Treatment Outcome , Time Factors , Risk Factors , Prognosis , Risk Assessment , Electrocardiography, Ambulatory , Action Potentials
16.
Eur Heart J ; 45(14): 1241-1251, 2024 Apr 07.
Article in English | MEDLINE | ID: mdl-38426911

ABSTRACT

BACKGROUND AND AIMS: Prior reports have demonstrated a favourable safety and efficacy profile of the Micra leadless pacemaker over mid-term follow-up; however, long-term outcomes in real-world clinical practice remain unknown. Updated performance of the Micra VR leadless pacemaker through five years from the worldwide post-approval registry (PAR) was assessed. METHODS: All Micra PAR patients undergoing implant attempts were included. Endpoints included system- or procedure-related major complications and system revision rate for any cause through 60 months post-implant. Rates were compared through 36 months post-implant to a reference dataset of 2667 transvenous pacemaker patients using Fine-Gray competing risk models. RESULTS: 1809 patients were enrolled between July 2015 and March 2018 and underwent implant attempts from 179 centres in 23 countries with a median follow-up period of 51.1 months (IQR: 21.6-64.2). The major complication rate at 60 months was 4.5% [95% confidence interval (CI): 3.6%-5.5%] and was 4.1% at 36 months, which was significantly lower than the 8.5% rate observed for transvenous systems (HR: .47, 95% CI: .36-.61; P < .001). The all-cause system revision rate at 60 months was 4.9% (95% CI: 3.9%-6.1%). System revisions among Micra patients were mostly for device upgrades (41.2%) or elevated thresholds (30.6%). There were no Micra removals due to infection noted over the duration of follow-up. At 36 months, the system revision rate was significantly lower with Micra vs. transvenous systems (3.2% vs. 6.6%, P < .001). CONCLUSIONS: Long-term outcomes with the Micra leadless pacemaker continue to demonstrate low rates of major complications and system revisions and an extremely low incidence of infection.


Subject(s)
Arrhythmias, Cardiac , Pacemaker, Artificial , Humans , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/etiology , Treatment Outcome , Equipment Design , Pacemaker, Artificial/adverse effects , Registries , Cardiac Pacing, Artificial/adverse effects
17.
Heart Rhythm O2 ; 5(2): 122-130, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38545323

ABSTRACT

Background: Cerebral microembolization and atrophy complicate atrial fibrillation (AF). Objectives: We aimed to compare changes in neuroimaging findings between AF patients treated with catheter ablation and those treated with medical therapy. Methods: In this pilot study, we evaluated differences in the change in regional white matter hyperintensity burden (WMHb) and cognitive function from baseline to 6 weeks and 1 year in patients treated with AF ablation (n = 12) and patients treated with medical management alone (n = 11). Change in cortical thickness over time in Alzheimer's disease (AD) risk, aging-associated, and shared AD risk/aging regions was also compared between groups. Results: The mean age was 69.7 ± 5.0 years, 78% of patients were male, 39% had persistent AF, and all received oral anticoagulation. There were no significant differences between groups in the change in cognitive function. At 6 weeks, there were no significant differences in periventricular WMHb changes between groups (0.00 vs 0.04, P = .12), but changes in attention/concentration were inversely correlated with periventricular (P = .01) and total (P = .03) WMHb. Medical management patients demonstrated significantly greater cortical thinning in AD risk regions from baseline to 1 year (P = .003). Conclusions: AF patients who underwent ablation demonstrated less cortical thinning in regions associated with AD risk than patients treated with medical therapy. Larger, prospective studies are needed to better understand the relationship between AF therapies and the development of cognitive decline.

18.
J Cardiovasc Electrophysiol ; 35(5): 950-964, 2024 May.
Article in English | MEDLINE | ID: mdl-38477184

ABSTRACT

INTRODUCTION: Peak frequency (PF) mapping is a novel method that may identify critical portions of myocardial substrate supporting reentry. The aim of this study was to describe and evaluate PF mapping combined with omnipolar voltage mapping in the identification of critical isthmuses of left atrial (LA) atypical flutters. METHODS AND RESULTS: LA omnipolar voltage and PF maps were generated in flutter using the Advisor HD-Grid catheter (Abbott) and EnSite Precision Mapping System (Abbott) in 12 patients. Normal voltage was defined as ≥0.5 mV, low-voltage as 0.1-0.5 mV, and scar as <0.1 mV. PF distributions were compared with ANOVA and post hoc Tukey analyses. The 1 cm radius from arrhythmia termination was compared to global myocardium with unpaired t-testing. The mean age was 65.8 ± 9.7 years and 50% of patients were female. Overall, 34 312 points were analyzed. Atypical flutters most frequently involved the mitral isthmus (58%) or anterior wall (25%). Mean PF varied significantly by myocardial voltage: normal (335.5 ± 115.0 Hz), low (274.6 ± 144.0 Hz), and scar (71.6 ± 140.5 Hz) (p < .0001 for all pairwise comparisons). All termination sites resided in low-voltage regions containing intermediate or high PF. Overall, mean voltage in the 1 cm radius from termination was significantly lower than the remaining myocardium (0.58 vs. 0.95 mV, p < .0001) and PF was significantly higher (326.4 vs. 245.1 Hz, p < .0001). CONCLUSION: Low-voltage, high-PF areas may be critical targets during catheter ablation of atypical atrial flutter.


Subject(s)
Action Potentials , Atrial Flutter , Catheter Ablation , Electrophysiologic Techniques, Cardiac , Predictive Value of Tests , Humans , Atrial Flutter/physiopathology , Atrial Flutter/diagnosis , Atrial Flutter/surgery , Female , Male , Aged , Middle Aged , Heart Rate
19.
J Am Coll Cardiol ; 83(6): 669-678, 2024 02 13.
Article in English | MEDLINE | ID: mdl-38325992

ABSTRACT

BACKGROUND: Phase II trials of asundexian were underpowered to detect important differences in bleeding. OBJECTIVES: The goal of this study was to obtain best estimates of effects of asundexian vs active control/placebo on major and clinically relevant nonmajor (CRNM) and all bleeding, describe most common sites of bleeding, and explore association between asundexian exposure and bleeding. METHODS: We performed a pooled analysis of 3 phase II trials of asundexian in patients with atrial fibrillation (AF), recent acute myocardial infarction (AMI), or stroke. Bleeding was defined according to the International Society on Thrombosis and Hemostasis (ISTH) criteria. RESULTS: In patients with AF (n = 755), both asundexian 20 mg and 50 mg once daily vs apixaban had fewer major/CRNM events (3 of 249; incidence rate [IR] per 100 patient-years 5.47 vs 1 of 254 [IR: not calculable] vs 6 of 250 [IR: 11.10]) and all bleeding (12 of 249 [IR: 22.26] vs 10 of 254 [IR: 18.21] vs 26 of 250 [IR: 50.56]). In patients with recent AMI or stroke (n = 3,409), asundexian 10 mg, 20 mg, and 50 mg once daily compared with placebo had similar rates of major/CRNM events (44 of 840 [IR: 7.55] vs 42 of 843 [IR: 7.04] vs 56 of 845 [IR: 9.63] vs 41 of 851 [IR: 6.99]) and all bleeding (107 of 840 [IR: 19.57] vs 123 of 843 [IR: 22.45] vs 130 of 845 [IR: 24.19] vs 129 of 851 [IR: 23.84]). Most common sites of major/CRNM bleeding with asundexian were gastrointestinal, respiratory, urogenital, and skin. There was no significant association between asundexian exposure and major/CRNM bleeding. CONCLUSIONS: Analyses of phase II trials involving >500 bleeds highlight the potential for improved safety of asundexian compared with apixaban and similar safety compared with placebo. Further evidence on the efficacy of asundexian awaits the results of ongoing phase III trials.


Subject(s)
Atrial Fibrillation , Myocardial Infarction , Stroke , Humans , Anticoagulants/adverse effects , Hemorrhage/chemically induced , Hemorrhage/epidemiology , Hemorrhage/complications , Pyridones/adverse effects , Stroke/etiology , Stroke/prevention & control , Atrial Fibrillation/complications , Myocardial Infarction/drug therapy , Myocardial Infarction/epidemiology
20.
Heart Rhythm ; 21(7): 1134-1142, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38417598

ABSTRACT

BACKGROUND: Loading of oral sotalol for atrial fibrillation requires 3 days, frequently in the hospital, to achieve steady state. The Food and Drug Administration approved loading with intravenous (IV) sotalol through model-informed development, without patient data. OBJECTIVE: We present results of the first multicenter evaluation of this recent labeling for IV sotalol. METHODS: The Prospective Evaluation Analysis and Kinetics of IV Sotalol (PEAKS) Registry was a multicenter observational registry of patients undergoing elective IV sotalol load for atrial arrhythmias. Outcomes, measured from hospital admission until first outpatient follow-up, included adverse arrhythmia events, efficacy, and length of stay. RESULTS: Of 167 consecutively enrolled patients, 23% were female; the median age was 68 (interquartile range, 61-74) years, and the median CHA2DS2-VASc score was 3 (interquartile range, 2-4). Overall, 99% were admitted for sotalol initiation (1% for dose escalation), with a target oral sotalol dose of either 80 mg twice daily (85 [51%]) or 120 mg twice daily (78 [47%]); 62 patients (37%) had an estimated creatinine clearance ≤90 mL/min. On presentation, 40% of patients were in sinus rhythm, whereas 26% underwent cardioversion before sotalol infusion. In 2 patients, sotalol infusion was stopped for bradycardia or hypotension. In 6 patients, sotalol was discontinued before discharge because of QTc prolongation (3), bradycardia (1), or recurrent atrial arrhythmia (2). The mean length of stay was 1.1 days, and 95% (n = 159) were discharged within 1 night. CONCLUSION: IV sotalol loading is safe and feasible for atrial arrhythmias, with low rates of adverse events, and yields shorter hospitalizations. More data are needed on the minimal duration required for monitoring in the hospital.


Subject(s)
Anti-Arrhythmia Agents , Atrial Fibrillation , Registries , Sotalol , Humans , Sotalol/administration & dosage , Female , Male , Atrial Fibrillation/drug therapy , Middle Aged , Anti-Arrhythmia Agents/administration & dosage , Aged , Prospective Studies , Dose-Response Relationship, Drug , Treatment Outcome , Infusions, Intravenous , Administration, Intravenous , Follow-Up Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...