Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 45
1.
J Wrist Surg ; 13(2): 151-157, 2024 Apr.
Article En | MEDLINE | ID: mdl-38505202

Background Open reduction and internal fixation of distal radius fractures is one of the most common procedures performed in wrist surgery. The use of volar locking plate has gained increasing interest in the past decade. Epiphyseal fixation can be done either with locking screws or smooth locking pegs, with no evidence supporting the use of one rather than the other. Purpose The aim of this study is to compare the stability of distal radius fixation by volar locking plate using locking screws or smooth locking pegs. Methods Adult patients with A2-A3 AO fractures treated with a volar plate with locking screws only or smooth locking pegs only were retrospectively included. Radiographic assessment was performed to evaluate extra-articular parameters in the intraoperative postreduction and fixation period and after bony healing. Forty-seven distal radius fractures were included. Results Twenty-four fractures had fixation with locking screws and 23 had fixation with smooth locking pegs. For both groups, all radiographic parameters measured showed a statistically significant difference between the intraoperative postreduction and fixation period and the remote postoperative period after union of the fracture ( p < 0.05) attesting a slight loss of reduction. Nevertheless, there were no significant differences between the groups in radiographic extra-articular parameters. Conclusion This clinical study shows that there is no difference in stability fixation between locking screws or smooth locking pegs in A2-A3 distal radius fractures. Clinical Relevance The use of smooth locking pegs only for epiphyseal fixation appears to be safe in volar plating of A2-A3 distal radius fractures in adult patients and could be an alternative to locking screws. More clinical data are needed to confirm these results. Level of Evidence Level III; retrospective comparative study.

2.
Arch Orthop Trauma Surg ; 144(1): 543-550, 2024 Jan.
Article En | MEDLINE | ID: mdl-37971511

INTRODUCTION: The purpose of this study is to evaluate whether using a Fracture Healing Patch (FHP) device that generates pulsed electromagnetic fields (PEMF), applied at the fracture site immediately after open reduction and internal fixation surgery, can accelerate healing of acute distal radius fractures. METHODS: In a prospective, double-blind, randomized, and sham-controlled study, thirty-two patients with DRFs treated with ORIF were included. Patients were allocated to a PEMF (active) group (n = 15) or a control (sham) group (n = 17). All patients were assessed with regard to functional Patient-Rated Wrist Evaluation (PRWE), SF12, and radiological union outcomes (X-rays and computed tomography (CT) scans) at 2, 4, 6, and 12 weeks postoperatively. RESULTS: Patients treated with the FHP demonstrated significantly bone bridging at 4 weeks as assessed by CT (70% vs 54%, p = 0.05). Mean grip strength in the active group was significantly higher as compared to control (16 ± 9 kg vs 7 ± 3.5 kg, respectively, p = 0. 02). The function subscale of the PRWE was significantly better in PEMF-treated group at 6 weeks after surgery (27.2 VS 35.5, p = 0.04). No statistically significant differences were found in SF12. CONCLUSION: PEMF application after ORIF of DRFs is safe, may accelerate bone healing which could lead to an earlier return to daily life activities and work. LEVEL OF EVIDENCE: I.


Radius Fractures , Wrist Fractures , Humans , Pilot Projects , Electromagnetic Fields , Prospective Studies , Treatment Outcome , Fracture Fixation, Internal/methods , Radius Fractures/surgery
3.
J Clin Med ; 12(5)2023 Feb 27.
Article En | MEDLINE | ID: mdl-36902653

BACKGROUND: this pilot study aimed at determining whether the application of a novel new method of generating pulsed electromagnetic field (PEMF), the Fracture Healing Patch (FHP), accelerates the healing of acute distal radius fractures (DRF) when compared to a sham treatment. METHODS: 41 patients with DRFs treated with cast immobilization were included. Patients were allocated to a PEMF group (n = 20) or a control (sham) group (n = 21). All patients were assessed with regard to functional and radiological outcomes (X-rays and CT scans) at 2, 4, 6 and 12 weeks. RESULTS: fractures treated with active PEMF demonstrated significantly higher extent of union at 4 weeks as assessed by CT (76% vs. 58%, p = 0.02). SF12 mean physical score was significantly higher in PEMF treated group (47 vs. 36, p = 0.005). Time to cast removal was significantly shorter in PEMF treated patients, 33 ± 5.9 days in PEMF vs. 39.8 ± 7.4 days in sham group (p = 0.002). CONCLUSION: early addition of PEMF treatment may accelerate bone healing which could lead to a shorter cast immobilization, thus allowing an earlier return to daily life activities and work. There were no complications related to the PEMF device (FHP).

4.
J Hand Surg Am ; 48(2): 197.e1-197.e6, 2023 02.
Article En | MEDLINE | ID: mdl-34852957

PURPOSE: To perform an analysis of electric scooter (e-scooter)-related upper limb fractures (ULFs), which have increased dramatically in parallel with the rapid rise in the use of e-scooters and shared e-scooter services in recent years. METHODS: We retrospectively reviewed the medical charts of e-scooter-related emergency department visits between January 2017 and January 2020 at a level I trauma center. All patients with ULFs were included in the study, and their data were analyzed for demographics, fracture diagnosis, associated injuries, and required surgical treatment. RESULTS: This study included 356 patients (50% men) with 458 ULFs, of which 23 (5%) were open fractures. The mean age of the cohort was 32.9 years (standard deviation, 10.1 years). The most common mechanism of injury was rider fall (92.1%). The nondominant hand was injured in 53.1% of cases, and 32.1% of all fractures were treated with surgery. A total of 120 (33.7%) patients sustained more than 1 ipsilateral ULF, and 27 (7.6%) patients had a concomitant contralateral ULF. Radial head fracture was the most common fracture type (n = 123, 26.8%), of which 16 (13%) were bilateral. The fifth ray was injured most frequently among the metacarpal and phalangeal fractures (n = 33, 47.1%). Most of the nonextremity-associated injuries were those of the head and maxillofacial bones. CONCLUSIONS: The most common ULF associated with e-scooters was the radial head fracture. Physicians should be alert to and seek associated fractures during initial assessments of e-scooter-related upper limb injuries. Further investigation may be warranted to evaluate the effectiveness of protective measures in reducing the number of injuries. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.


Arm Injuries , Fractures, Open , Radius Fractures , Male , Humans , Adult , Female , Retrospective Studies , Arm Injuries/epidemiology , Arm Injuries/etiology , Arm Injuries/surgery , Emergency Service, Hospital , Radius Fractures/etiology , Radius Fractures/surgery , Upper Extremity/surgery , Accidents, Traffic
5.
J Orthop Trauma ; 36(12): 634-638, 2022 12 01.
Article En | MEDLINE | ID: mdl-36399675

OBJECTIVES: To assess outcomes and complications of conservatively managed humeral diaphyseal fractures in elderly patients, with an emphasis on the subgroup diagnosed with dementia. DESIGN: Retrospective. SETTING: Upper extremity surgery unit at an academic Level I trauma center. PATIENTS/PARTICIPANTS: Consecutive patients 65 years of age and older who were managed conservatively for humeral diaphyseal fractures between 2007 and 2015. INTERVENTION: Conservatively managed humeral diaphyseal fractures. MAIN OUTCOME MEASUREMENTS: Complications and radiographic outcomes. RESULTS: One-hundred twenty-four patients who were conservatively managed for humeral diaphyseal fractures were identified. Their mean age was 77 (65-92) years, 36 (30%) of them were male and 88 (70%) were female. Fifty-seven (46%) patients experienced complications associated with their treatment, and 33 (27%) patients were eventually treated surgically. Seventeen (14%) patients were diagnosed with dementia. This subgroup had 64% fracture-related complications, and all of them were operated (P-value <0.01 compared with age-matched patients among the other 107 participants in the study). CONCLUSION: Conservative management of humeral diaphyseal fractures seems to be associated with greater morbidity in elderly patients, especially in those diagnosed with dementia. Therefore, early surgical treatment should be considered. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.


Dementia , Humeral Fractures , Humans , Male , Female , Aged , Conservative Treatment , Retrospective Studies , Humeral Fractures/therapy , Humeral Fractures/surgery , Humerus , Dementia/complications
6.
SICOT J ; 8: 20, 2022.
Article En | MEDLINE | ID: mdl-35608413

OBJECTIVES: To examine the clinical feasibility and results of a multidisciplinary workflow, employing rapid three-dimensional (3D) scanning and modeling software along with a high-speed printer, for in-hospital production of patient-specific 3D-printed casts, for the treatment of non-displaced wrist and hand fractures. METHODS: Consenting adult patients admitted to the emergency department (ED) due to wrist or hand fractures between January and February 2021 were prospectively enrolled. The study participants underwent conversion of the standard plaster of Paris cast to a 3D-printed cast one week after the ED visit, and follow-up examinations were performed around two, six, and twelve weeks later. The primary objective was to examine the clinical feasibility in terms of complexity and length of the overall procedure. Secondary outcomes were patient-reported impressions and radiological results. RESULTS: Twenty patients (16 males, mean age 37 ± 13.1 years) were included. The entire printing workflow took a mean of 161 ± 8 min. All patients demonstrated clinical improvement and fracture union at final follow-up, with no pressure sores or loss of reduction. Patient-reported comfort and satisfaction rates were excellent. The mean Visual Analog Scale was 0.9 ± 1.1 and 0.6 ± 1, and the mean Disabilities of the Arm, Shoulder, and Hand score was 18.7 ± 9.5 and 7.6 ± 7.6 at 2 and 6 weeks after application of the 3D-printed cast, respectively. CONCLUSION: The in-hospital workflow was feasible and efficient, with excellent clinical and radiographic results and high patient satisfaction and comfort rates. Our medical center now routinely provides this cast option for non-displaced wrist and hand fractures. LEVEL OF EVIDENCE: IV, Therapeutic Study.

7.
SICOT J ; 8: 17, 2022.
Article En | MEDLINE | ID: mdl-35593692

Wrist arthroscopy is a constantly evolving procedure. Allowing direct visualization and dynamic testing of intra-articular structures led to a novel approach toward traumatic and degenerative lesions based on most of the classifications routinely used in wrist surgery. The development of specific instrumentation, combined with a novel understanding of the local anatomy, progressively allowed wrist surgeons to describe more ambitious and complex surgeries. Wrist arthroscopy has become an increasingly useful tool in hand and wrist surgeons' panoply and seems promised to have further development in the future. This paper discusses the surgical technique and the various pathologies that can be treated by arthroscopy of the wrist.

8.
Orthopedics ; 44(4): e583-e587, 2021.
Article En | MEDLINE | ID: mdl-34292836

Several anatomic plates for fixation of the olecranon after a fracture or an osteotomy are commercially available. They serve as an alternative for tension band wiring, which is associated with a relatively high complication rate. Plating of the olecranon reportedly might result in nonunion or malunion and eventually may require revision surgery or plate removal because of skin irritation. The authors describe a proximal periprosthetic avulsion fracture of the tip of the olecranon as a unique complication associated with the use of an anatomic plate for fixation of an olecranon osteotomy. This retrospective case series included 35 patients with comminuted distal humerus fractures treated by open reduction and internal fixation through an olecranon osteotomy with an anatomic olecranon plate. Of the 35 patients, 6 (17.1%) had postoperative olecranon tip fracture, just proximal to the osteotomy site. In all cases, the fracture line coursed through the proximal cluster of screws situated on the proximal part of the plate. Avulsion fractures of the tip of the olecranon after plating of the olecranon osteotomy could have occurred as a result of biomechanical factors. The short design of the proximal part of the plate and the high screw density in the proximal part of the olecranon could lead to increased mechanical stress during contraction of the triceps. This complication should prompt further biomechanical evaluation of the plate design. [Orthopedics. 2021;44(4):e583-e587.].


Olecranon Process , Periprosthetic Fractures , Bone Plates/adverse effects , Fracture Fixation, Internal/adverse effects , Humans , Olecranon Process/diagnostic imaging , Olecranon Process/surgery , Osteotomy/adverse effects , Retrospective Studies , Treatment Outcome
9.
Shoulder Elbow ; 13(2): 213-222, 2021 Apr.
Article En | MEDLINE | ID: mdl-33897853

BACKGROUND: Severe radiocapitellar pathologies represent a unique problem in the pediatric population, as radial head excision can lead to substantial long-term complications. We present a case series of four pediatric patients treated by a novel technique-radial head excision followed by Achilles allograft interposition arthroplasty. METHODS: Four children (ages 12-15 years) are described. Their clinical and radiographic outcomes were assessed by a visual analog scale, the Mayo Elbow Performance Score, the Disabilities of the Arm, Shoulder and Hand questionnaire, grip strength, and range of motion. RESULTS: At a mean follow-up of two years, the average flexion-extension arc of motion improved from 107° to 131°, and the rotation arc improved from 100° to 154°. The average visual analog scale, Mayo Elbow Performance Score, and Disabilities of the Arm, Shoulder and Hand scores were 2, 92.5, and 11.5, respectively. Two patients required subsequent additional procedures-manipulation under anesthesia and ulnar shortening osteotomy. Proximal migration of the radius was observed in three out of the four patients. DISCUSSION: Combined radial head excision and Achilles allograft interposition arthroplasty represents a viable option for the treatment of chronic pediatric radiocapitellar pathologies, with good results in terms of clinical and functional outcomes as well as patient satisfaction in the short-medium term.

10.
Arch Orthop Trauma Surg ; 139(12): 1779-1783, 2019 Dec.
Article En | MEDLINE | ID: mdl-31463689

INTRODUCTION: A commonly used method of fixation of the transferred coracoid in the traditional Latarjet-Bristow procedure (open or arthroscopic) is by two bicortical screws. Although mechanically effective, screw fixation is also a major source of hardware and neurologic complications. This study aimed to compare the biomechanical performances of traditional metal screws and endobuttons as fixators of the Latarjet-Bristow procedure. MATERIALS AND METHODS: Nine fresh-frozen cadaveric human scapulae with the conjoined tendon attached to the coracoid process were used for the Latarjet-Bristow procedure. The specimens were randomly assigned one of two groups: fixation using two 4.5-mm cannulated partially threaded Latarjet-Bristow experience screws or fixation using a suture-button construct. Specimens were secured in a material testing machine and cyclically preconditioned from 2 to 10 N at 0.1 Hz for ten cycles. They were then pulled to failure at a normalized displacement rate of 400% of the measured gauge length per minute. The maximal load-to-failure, stiffness and stress were calculated using a custom script. The failure mechanism and site were recorded for each specimen. RESULTS: There were no significant differences in the maximal load-to-failure or other biomechanical properties of the two fixation techniques, but the failure mechanisms were unique to each one. Four specimens fixated with screws underwent graft failures (fracture) through the proximal or distal drill hole. Five specimens fixated with endobuttons underwent failure due to glenoid bone fractures. CONCLUSIONS: A single endobutton fixation appears to be biomechanically comparable to screw fixation in the Latarjet-Bristow procedure and provides a lower risk for graft fracture. Further studies with more numerous specimens are warranted to conclusively validate these findings.


Bone Screws , Fracture Fixation, Internal/methods , Joint Instability/surgery , Scapula/surgery , Shoulder Joint/surgery , Sutures , Biomechanical Phenomena , Cadaver , Female , Humans , Joint Instability/physiopathology , Male , Materials Testing , Shoulder Joint/physiology
11.
Eur J Orthop Surg Traumatol ; 29(8): 1679-1685, 2019 Dec.
Article En | MEDLINE | ID: mdl-31280368

INTRODUCTION: Elbow joint stiffness is a common complication following elbow trauma or surgery. Current practices include first-line treatment with physiotherapy and various types of splints. In cases where early postoperative loss of elbow motion interferes with activities of daily living, manipulation under anesthesia (MUA) is considered a viable treatment option, but there is currently only limited data on the results of this procedure and its complications. MATERIALS AND METHODS: This retrospective study was comprised of 12 consecutive patients who underwent MUA for the treatment of postsurgical elbow stiffness in one institution between 2010 and 2017. Their pre- and post-manipulation range of motion and their functional scores were assessed. RESULTS: MUA was performed at a mean of 52 days (range 39-91 days) following the last surgical intervention, and the patients were followed for a mean of 3 years (range 0.75-7 years). The average flexion-extension arc of motion improved by 53.8°, and the average rotation arc improved by 57°. The average Mayo Elbow Performance Score was 73 (range 0-100) at the latest follow-up. Two patients eventually underwent an open elbow contracture release due to poor post-manipulation results. There were no post-MUA complications. CONCLUSIONS: MUA of a postoperative stiff elbow can improve both flexion-extension and rotatory arc of motion in cases of early evolving postoperative stiffness and should be part of the armamentarium for the treatment of this often debilitating condition.


Elbow Joint/physiopathology , Manipulation, Orthopedic/methods , Postoperative Complications/physiopathology , Postoperative Complications/therapy , Range of Motion, Articular , Activities of Daily Living , Adult , Aged , Child , Conscious Sedation , Female , Follow-Up Studies , Humans , Male , Manipulation, Orthopedic/adverse effects , Middle Aged , Nerve Block , Rotation , Young Adult
12.
Acta Biomater ; 83: 314-321, 2019 01 01.
Article En | MEDLINE | ID: mdl-30423432

Hyaluronan (HA)-lipid layers on model (mica) surfaces massively reduce friction as the surfaces slide past each other, and have been proposed, together with lubricin, as the boundary layers accounting for the extreme lubrication of articular cartilage. The ability of such HA-lipid complexes to lubricate sliding biological tissues has not however been demonstrated. Here we show that HA-lipid layers on the surface of an intrasynovial tendon can strongly reduce the friction as the tendon slides within its sheath. We find a marked lubrication synergy when combining both HA and lipids at the tendon surface, relative to each component alone, further enhanced when the polysaccharide is functionalized to attach specifically to the tissue. Our results shed light on the lubricity of sliding biological tissues, and indicate a novel approach for lubricating surfaces such as tendons and, possibly, articular cartilage, important, respectively, for alleviating function impairment following tendon injury and repair, or in the context of osteoarthritis. STATEMENT OF SIGNIFICANCE: Lubrication breakdown between sliding biological tissues is responsible for pathologies ranging from dry eye syndrome to tendon-injury repair impairment and osteoarthritis. These are increasing with human longevity and impose a huge economic and societal burden. Here we show that synergy of hyaluronan and lipids, molecules which are central components of synovial joints and of the tendon/sheath system, can strongly reduce friction between sliding biological tissues (the extrasynovial tendon sliding in its sheath), relative to untreated tissue or to either component on its own. Our results point to the molecular origins of the very low friction in healthy tendons and synovial joints, as well as to novel treatments of lubrication breakdown in these organs.


Cartilage, Articular/metabolism , Friction , Hyaluronic Acid/metabolism , Lipid Metabolism , Lubrication , Synovial Fluid/metabolism , Aluminum Silicates , Animals , Avian Proteins/chemistry , Avian Proteins/metabolism , Cartilage, Articular/chemistry , Chickens , Glycoproteins/chemistry , Glycoproteins/metabolism , Humans , Hyaluronic Acid/chemistry , Lipids/chemistry , Osteoarthritis , Synovial Fluid/chemistry
13.
Arch Orthop Trauma Surg ; 138(4): 591-596, 2018 Apr.
Article En | MEDLINE | ID: mdl-29453642

INTRODUCTION: Repeated attempts of closed reduction of distal radius fractures (DRF) are performed in the emergency department setting to optimize fracture alignment and avoid surgery. The additional manipulation of the fracture may, however, increase dorsal comminution and lead to loss of reduction in the cast. This retrospective cohort study has investigated the effect of second reduction attempt on fracture alignment and comminution. MATERIALS AND METHODS: Six-hundred-eighteen patients with DRF were treated in the medical center in 2007-2010. Seventy-six (12.3%) DRF who underwent two reductions were included in the study. Radiographs taken after the first and second reduction attempts were reviewed for changes in fracture alignment parameters (radial height, radial inclination, volar tilt) and dorsal comminution length. Patients were also followed retrospectively to determine the rates of secondary displacement in a cast. RESULTS: A second closed reduction attempt improved mean radial height by 1.43 mm, mean radial inclination by 1.62° and mean volar tilt by 8.75°. Mean dorsal comminution length increased by 1.6 mm. Of the 19 (25%) patients with acceptable alignments after two reduction attempts, follow-up radiographs were available for 12, which showed successful reduction in four cases (33.3 or 5.2% of total 76 patients). CONCLUSIONS: A second closed reduction attempt improved immediate fracture alignment, but also worsened dorsal comminution. Only 5.2% of patients who underwent two reduction attempts had an acceptable final alignment and did not require surgery. Increased dorsal comminution may further compromise fracture stability, complicate surgery and have negative effect on the postoperative course.


Closed Fracture Reduction/statistics & numerical data , Emergency Service, Hospital/statistics & numerical data , Radius Fractures , Humans , Radiography , Radius Fractures/diagnostic imaging , Radius Fractures/therapy , Retrospective Studies
14.
Skeletal Radiol ; 47(6): 833-837, 2018 Jun.
Article En | MEDLINE | ID: mdl-29356843

OBJECTIVES: Intraoperative hairline longitudinal fractures were recently reported in association with distal radius volar plating. Our aim was to further analyze this newly described complication. METHODS: A retrospective radiographic and chart review was performed on 225 patients who underwent distal radius plating between June 2013 and June 2015. The Acu-Loc/Acu-Loc2© plating system (Acumed, Hillsboro, OR, USA) was used in 208 cases, and the VariAx© plating system (Stryker, Kalamazoo, MI, USA) was used in 17 cases. Three independent reviewers performed a blind evaluation of all relevant radiographs for the occurrence of longitudinal fractures around the plate, and validity was considered only when there was agreement among all three of them. RESULTS: Hairline longitudinal fractures were identified in 57 cases (25%), 55 with the Acu-Loc/Acu-Loc2© system and 2 with the VariAx© system. All fractures occurred with volar plating. Fracture occurrence was associated with age over 59 years, female gender, extra-articular fractures, and the use of Hexalobe screws (Acu-Loc/Acu-Loc2© system). CONCLUSIONS: We believe that the source of fracture occurrence lies within the screw design and that better screw design and possibly tapping in patients at risk may reduce the occurrence of intraoperative hairline longitudinal fractures. Further clinical and biomechanical research is needed to better understand this newly reported complication.


Bone Plates/adverse effects , Fracture Fixation, Internal/adverse effects , Fracture Fixation, Internal/instrumentation , Intraoperative Complications/diagnostic imaging , Intraoperative Complications/etiology , Radius Fractures/etiology , Radius Fractures/surgery , Adolescent , Adult , Aged , Aged, 80 and over , Female , Fluoroscopy , Humans , Male , Middle Aged , Radius Fractures/diagnostic imaging , Reoperation , Retrospective Studies , Risk Factors , Sex Factors , Treatment Outcome
15.
Hand (N Y) ; 12(6): 557-560, 2017 11.
Article En | MEDLINE | ID: mdl-29091487

BACKGROUND: This study compared the radiological outcomes of adult closed distal radius fractures (DRFs) reduction with and without fluoroscopy. We hypothesized that fluoroscopy-assisted reduction would not improve radiographic alignment or decrease the need for surgery. METHODS: Hospital medical records and radiographic images of all patients who presented with DRFs between April to June 2009 and April to June 2013 were reviewed. All patients underwent closed reduction and immobilization with or without fluoroscopic assistance. Reduction attempts were noted and pre- and postreduction posteroanterior and lateral radiographs were reviewed for fracture stability. RESULTS: Eighty-four patients underwent reduction without fluoroscopy (group 1), and 90 patients underwent reduction with the aid of fluoroscopy (group 2). According to accepted radiographic guidelines, nonsurgical treatment was indicated for 62% of patients in group 1 and 56% of patients in group 2 ( P = .44). In addition, no significant difference between the groups was observed in any postreduction radiographic parameters ( P > .53) or postreduction alignment of unstable fractures ( P = .47). CONCLUSIONS: Reduction without the use of fluoroscopy demonstrated noninferiority when compared with fluoroscopy-assisted reduction in the emergency department for closed adult DRFs.


Closed Fracture Reduction/methods , Fluoroscopy , Fractures, Closed , Radius Fractures , Cohort Studies , Emergency Service, Hospital , Female , Fractures, Closed/diagnostic imaging , Fractures, Closed/therapy , Humans , Immobilization , Male , Middle Aged , Radius Fractures/diagnostic imaging , Radius Fractures/therapy , Retrospective Studies
16.
Am J Sports Med ; 44(1): 177-82, 2016 Jan.
Article En | MEDLINE | ID: mdl-26216105

BACKGROUND: The effect of corticosteroids on tendons is poorly understood, and current data are insufficient and conflicting. PURPOSE: To evaluate the effects of corticosteroid injections on intact and injured rotator cuffs (RCs) through biomechanical and radiographic analyses in a rat model. STUDY DESIGN: Controlled laboratory study. METHODS: A total of 70 rats were assigned to 7 groups. Uninjured rats (no tear) received either a single saline injection, a single methylprednisolone acetate (MTA) injection, or triple MTA injections. Injured rats (unilateral supraspinatus injury) received either a single saline injection, triple saline injections, a single MTA injection, or triple MTA injections (injections were subacromial; repeat injections were administered weekly). Rats were sacrificed 1 week after final injection. Shoulders were harvested and grossly inspected, and the supraspinatus tendon was evaluated biomechanically. Bone density at the tendon insertion site on the greater tuberosity was assessed by micro-computed tomography. RESULTS: Intact RCs exposed to triple MTA injections had significantly decreased maximal load and stiffness compared with the control group (14.43 vs 21.25 N and 8.21 vs 16.6 N/mm, respectively; P < .05). Injured RCs exposed to steroid treatment had significantly lower maximal load (single saline: 10.91 N, single steroid: 8.43 N [P < .05]; triple control: 15.77 N, triple steroid: 11.65 N [P < .05]) compared with the control at 3 weeks. Greater tuberosity volume density and connectivity density were significantly lower in undamaged rats after triple MTA injection (P < .05). CONCLUSION: The study results clearly showed that repeated doses of corticosteroids significantly weaken rat RC and negatively affect bone quality in addition to possibly causing deterioration of the osteotendinous junction. However, data retrieved from animals must be scrupulously analyzed before extrapolation to humans. As such, the potential benefits and harms of subacromial corticosteroid treatment must be considered before administration. CLINICAL RELEVANCE: The potential benefit and detrimental effects of corticosteroid injection should be thoroughly considered before it is administered subacromially in patients with RC injuries.


Adrenal Cortex Hormones/toxicity , Methylprednisolone/analogs & derivatives , Rotator Cuff/drug effects , Animals , Biomechanical Phenomena , Bone Density/physiology , Humans , Injections, Intra-Articular , Male , Methylprednisolone/toxicity , Methylprednisolone Acetate , Rats, Wistar , Rotator Cuff/diagnostic imaging , Rotator Cuff Injuries , Rupture/physiopathology , X-Ray Microtomography
17.
J Hand Surg Am ; 40(12): 2421-6, 2015 Dec.
Article En | MEDLINE | ID: mdl-26527592

PURPOSE: To determine whether hand surgeons could accurately and consistently estimate the size of partial flexor tendon lacerations. MATERIALS AND METHODS: Thirty-two partial flexor tendon lacerations were made in the flexor digitorum profundus tendons of a fresh-frozen cadaveric hand. Four hand surgeons and 5 residents estimated the size of the lacerations. Estimates were repeated 3 days later. Magnified images of the laceration cross-section were used to calculate the true size of each laceration. Inter- and intrarater reliability were calculated using the intraclass correlation coefficient. Accuracy was measured with the mean bias error and the mean absolute error. RESULTS: Interrater and intrarater reliabilities were both high. There was a high level of consistency for both surgeons and residents. In terms of accuracy, there was a 3% bias toward underestimation. The mean absolute error was 11%. There was no statistically significant difference between the accuracy of attending hand surgeons and that of residents. Participants were less accurate when estimating lacerations close to a 60% laceration threshold for surgical repair (lacerations in the 50%-70% range). For lacerations within this range, an incorrect management decision would have been made 17% of the time, compared with 7% of the time for lacerations outside that range. CONCLUSIONS: The accuracy and reliability of surgeon estimates of partial flexor tendon laceration size were high for surgeons and residents. Accuracy was lower for lacerations close to the threshold for repair. CLINICAL RELEVANCE: Visual estimation is acceptable for evaluating partial flexor tendon lacerations, but it may be less reliable for lacerations near the threshold for repair. Therefore, surgeons should be cautious when deciding whether or not to repair partial lacerations in the borderline range.


Hand Injuries/diagnosis , Lacerations/diagnosis , Tendon Injuries/diagnosis , Cadaver , Hand Injuries/surgery , Humans , Lacerations/surgery , Reproducibility of Results , Tendon Injuries/surgery
18.
J Orthop ; 11(2): 103-9, 2014 Jun.
Article En | MEDLINE | ID: mdl-25104895

AIM: To compare the functional and radiographic results of dynamic hip screw (DHS) and expandable proximal femoral nail (EPFN) in the treatment of extracapsular hip fractures. METHODS: A randomized controlled trial of sixty hip fracture patients. Outcomes included mortality, residency, independence, mobility, function and radiographic results at a minimum of 1 year. RESULTS: Twenty-nine EPFN patients demonstrated fewer cases of shaft medialization or femoral offset shortening compared to the 31 DHS patients. Mortality, complications and functional outcomes were similar. CONCLUSION: EPFN provides stable fixation of pertrochanteric hip fractures and prevents neck shortening that is commonly observed after DHS fixation.

19.
J Hand Surg Am ; 39(1): 19-23, 2014 Jan.
Article En | MEDLINE | ID: mdl-24315488

PURPOSE: To describe in a cadaveric model a tenodesis procedure for restoring distal interphalangeal joint flexion in patients with unrepairable isolated flexor digitorum profundus (FDP) injuries. METHODS: In 16 fresh-frozen cadaveric fingers, the FDP tendon was transected 1 cm proximal to its insertion to simulate an isolated zone I laceration. The injury was reconstructed using a palmaris longus tendon graft to create a mechanical linkage between the interphalangeal joints, which restored coordinated interphalangeal joint flexion. Joint motion and the force required to flex and extend the fingers were tested before and after the tenodesis. RESULTS: After FDP zone I laceration, distal interphalangeal joint flexion with load applied to the flexor digitorum superficialis tendon averaged 2°. The FDP flexion increased to a mean of 57° after the tenodesis. The sum of metacarpophalangeal, proximal interphalangeal and distal interphalangeal joint flexion averaged 186° before the tenodesis and increased to 233° after the tenodesis. The force required to achieve fingertip to palm contact and the force required to fully extend the proximal interphalangeal joint were not altered. CONCLUSIONS: In this cadaveric model, this tenodesis successfully restored coordinated interphalangeal joint flexion after a simulated zone I FDP laceration with improvements in distal interphalangeal joint flexion and composite finger flexion. Critical factors such as the effects of inflammation, edema, soft tissue healing, and scar formation could not be evaluated and would likely affect the outcomes of this procedure. The in vivo results of this procedure are not known. CLINICAL RELEVANCE: The potential use of this tenodesis for treating unrepairable isolated zone I FDP injuries was demonstrated in a cadaveric model. Further investigation of the outcomes and complications in vivo would be required before routine clinical use.


Finger Injuries/surgery , Finger Joint/surgery , Range of Motion, Articular/physiology , Tendon Injuries/surgery , Tendons/transplantation , Tenodesis/methods , Finger Injuries/physiopathology , Humans , Models, Anatomic , Suture Anchors , Tendon Injuries/physiopathology
20.
J Hand Surg Am ; 38(3): 453-8, 2013 Mar.
Article En | MEDLINE | ID: mdl-23428187

PURPOSE: To propose a classification system for type A ulnar polydactyly based on radiographic findings and characterize the demographic features of patients with these deformities. METHODS: We identified 49 patients with type A ulnar polydactyly of the hand who were seen in our institution over 20 years. Patients' medical records and radiographs were retrospectively reviewed and used to distinguish morphological subtypes. RESULTS: Ninety-six percent of the deformities (64/67) were allocated to 1 of the 5 subgroups of our suggested classification, and the type that originated from the metacarpophalangeal joint was the most common. Sixty-nine percent of patients in our series (34/49) had either bilateral type A or a contralateral type B ulnar polydactyly, and 63% (31/49) had ulnar polydactyly of one or both feet. Twenty-four percent of patients (12/49) had associated syndromes or congenital anomalies involving areas other than the hand or foot. The most common syndrome associated with type A ulnar polydactyly was chondroectodermal dysplasia (n = 3). Sixty-five percent of the patients (32/49) were Caucasian, 20% were Hispanic (10/49), 12% were African American (6/49), and one was Asian. The percentage of African Americans in our series was similar to that in the general patient population seen in our institution. CONCLUSIONS: The majority of type A ulnar polydactyly can be classified into 1 of 5 morphological subtypes that have potential clinical relevance regarding surgical treatment. In patients with type A ulnar polydactyly, contralateral hand and foot polydactyly is frequent. Associated congenital anomalies and syndromes can also be present.


Fingers/abnormalities , Polydactyly/classification , Polydactyly/epidemiology , Age Distribution , Child , Child, Preschool , Cohort Studies , Databases, Factual , Female , Fingers/diagnostic imaging , Follow-Up Studies , Humans , Incidence , Infant , Male , Polydactyly/diagnostic imaging , Radiography , Retrospective Studies , Risk Assessment , Sex Distribution , Ulna/abnormalities , Ulna/diagnostic imaging
...