ABSTRACT
In response to the 2015 Zika virus (ZIKV) epidemic that occurred in Brazil, numerous commercial serological assays have been developed for clinical and research applications. Diagnosis of recent infection in pregnant women remains challenging. Having standardized, comparative studies of ZIKV tests is important for implementing optimal diagnostic testing and disease surveillance. This is especially important for serology tests used to detect ZIKV infection given that antibodies against ZIKV can cross-react with other arboviruses in the same virus family, such as dengue virus (DENV), yellow fever virus (YFV) and West Nile virus (WNV). We looked at the sensitivity and specificity of tests detecting ZIKV antibodies (IgM, IgG) from multiple manufacturers using panels of samples previously collected with known exposure to ZIKV and other arboviruses. We found that performance of the IgM tests was highly variable, with only one test (Inbios 2.0 IgM capture ELISA) having both high sensitivity and specificity. All IgG tests showed good sensitivity; however, specificity was highly variable, with some assays giving false-positive results on samples infected by another flavivirus. Overall, the results confirmed that accurate ZIKV antibody testing is challenging, especially in specimens from regions endemic for multiple other flaviviruses, and highlight the importance of available and suitable reference samples to evaluate ZIKV diagnostics.
Subject(s)
Antibodies, Viral , Immunoglobulin G , Immunoglobulin M , Sensitivity and Specificity , Serologic Tests , Zika Virus Infection , Zika Virus , Humans , Zika Virus/immunology , Zika Virus Infection/diagnosis , Zika Virus Infection/immunology , Zika Virus Infection/blood , Antibodies, Viral/blood , Antibodies, Viral/immunology , Serologic Tests/methods , Serologic Tests/standards , Immunoglobulin M/blood , Immunoglobulin G/blood , Enzyme-Linked Immunosorbent Assay/methods , Enzyme-Linked Immunosorbent Assay/standards , Cross Reactions/immunology , Female , Pregnancy , BrazilABSTRACT
Cross-reactivity within flavivirus antibody assays, produced by shared epitopes in the envelope proteins, can complicate the serological diagnosis of Zika virus (ZIKAV) infection. We assessed the utility of the plaque reduction neutralization test (PRNT) to confirm recent ZIKAV infections and rule out misleading positive immunoglobulin M (IgM) results in areas with various levels of past dengue virus (DENV) infection incidence. We reviewed PRNT results of sera collected for diagnosis of ZIKAV infection from 1 January through 31 August 2016 with positive ZIKAV IgM results, and ZIKAV and DENV PRNTs were performed. PRNT result interpretations included ZIKAV, unspecified flavivirus, DENV infection, or negative. For this analysis, ZIKAV IgM was considered false positive for samples interpreted as a DENV infection or negative. In U.S. states, 208 (27%) of 759 IgM-positive results were confirmed to be ZIKAV compared to 11 (21%) of 52 in the U.S. Virgin Islands (USVI), 15 (15%) of 103 in American Samoa, and 13 (11%) of 123 in Puerto Rico. In American Samoa and Puerto Rico, more than 80% of IgM-positive results were unspecified flavivirus infections. The false-positivity rate was 27% in U.S. states, 18% in the USVI, 2% in American Samoa, and 6% in Puerto Rico. In U.S. states, the PRNT provided a virus-specific diagnosis or ruled out infection in the majority of IgM-positive samples. Almost a third of ZIKAV IgM-positive results were not confirmed; therefore, providers and patients must understand that IgM results are preliminary. In territories with historically higher rates of DENV transmission, the PRNT usually could not differentiate between ZIKAV and DENV infections.