Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Publication year range
1.
Appl Radiat Isot ; 153: 108830, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31437722

ABSTRACT

The aim of the European Metrology Research Project MetroBeta is to improve the knowledge of the shapes of beta spectra, both in terms of theoretical calculation and measurement. The precise knowledge of beta spectra is required for the activity standardisation of pure beta emitters. Metallic magnetic calorimeters (MMCs), a type of cryogenic detectors, with the beta emitter embedded in the absorber have proven to be among the best beta spectrometers, in particular for low-energy beta transitions. Within this project, new designs of MMCs optimized for five different beta energy ranges were developed and a new detector module was constructed. The beta spectra of 151Sm, 14C and 99Tc have been measured so far; additional measurements with 36Cl are under preparation. Improved theoretical calculation methods and complementary measurement techniques complete the project.

2.
Phys Rev Lett ; 119(12): 122501, 2017 Sep 22.
Article in English | MEDLINE | ID: mdl-29341650

ABSTRACT

The isotope ^{163}Ho is in many ways the best candidate to perform experiments to investigate the value of the electron neutrino mass. It undergoes an electron capture process to ^{163}Dy with an energy available to the decay, Q_{EC}, of about 2.8 keV. According to the present knowledge, this is the lowest Q_{EC} value for such transitions. Here we discuss a newly obtained spectrum of ^{163}Ho, taken by cryogenic metallic magnetic calorimeters with ^{163}Ho implanted in the absorbers and operated in anticoincident mode for background reduction. For the first time, the atomic deexcitation of the ^{163}Dy daughter atom following the capture of electrons from the 5s shell in ^{163}Ho, the OI line, was observed with a calorimetric measurement. The peak energy is determined to be 48 eV. In addition, a precise determination of the energy available for the decay Q_{EC}=(2.858±0.010_{stat}±0.05_{syst}) keV was obtained by analyzing the intensities of the lines in the spectrum. This value is in good agreement with the measurement of the mass difference between ^{163}Ho and ^{163}Dy obtained by Penning-trap mass spectrometry, demonstrating the reliability of the calorimetric technique.

3.
Arch Esp Urol ; 42 Suppl 1: 95-108, 1989.
Article in Spanish | MEDLINE | ID: mdl-2634944

ABSTRACT

The authors reviewed 110 cases of staghorn calculi (71 complete and 39 incomplete) from 693 cases of lithiasis that had been treated over a 15-month period at their hospital with the Dornier HM-3 lithotripter. Good results were achieved in 72.2% of the cases. One patient had a fall in hematocrit and a subcapsular hematoma which evolved well. Of the patients who did not have a double-J catheter, 33.6% had steinstrasse versus 27.9% of those who did. Because the complication rate is lower when double-J catheter placement is combined with ESWL this approach is recommended instead of PCN + ESWL.


Subject(s)
Kidney Calculi/therapy , Lithotripsy/instrumentation , Urinary Catheterization/instrumentation , Adolescent , Adult , Aged , Aged, 80 and over , Child , Evaluation Studies as Topic , Female , Humans , Kidney Calculi/diagnostic imaging , Kidney Calculi/pathology , Male , Middle Aged , Radiography
SELECTION OF CITATIONS
SEARCH DETAIL
...