Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
Anal Chem ; 81(19): 8157-66, 2009 Oct 01.
Article in English | MEDLINE | ID: mdl-19715301

ABSTRACT

An open-to-air type electrolyte cathode discharge (ELCAD) has been developed with a new design. The present configuration leads to a stable plasma even at low flow rates (0.96 mL/min). Plasma fluctuations arising from the variations in the gap between solid anode and liquid cathode were eliminated by providing a V-groove to the liquid glass-capillary. Cathode (ground) connection is given to the solution at the V-groove itself. Interfaced to atomic emission spectrometry (AES), its analytical performance is evaluated. The optimized molarity of the solution is 0.2 M. The analytical response curves for Ca, Cu, Cd, Pb, Hg, Fe, and Zn demonstrated good linearity. The limit of detections of Ca, Cu, Cd, Pb, Hg, Fe, and Zn are determined to be 17, 11, 5, 45, 15, 28, and 3 ng mL(-1). At an integration time of 0.3 s, the relative standard deviation (RSD) values of the acid blank solutions are found to be less than 10% for the elements Ca, Cu, Cd, Hg, Fe, and Zn and 18% for Pb. The method is applied for the determination of the elemental constituents in different matrix materials such as tuna fish (IAEA-350), oyster tissue (NIST SRM 1566a), and coal fly ash (CFA SRM 1633b). The obtained results are in good agreement with the certified values. The accuracy is found to be between 7% and 0.6% for major to trace levels of constituent elements and the precision between 11% and 0.6%. For the injection of 100 microL of 200 ng mL(-1) mercury solution at the flow rate of 0.8 mL/min, the flow injection studies resulted in the relative standard deviation (RSD) of 8%, concentration detection limit of 10 ng/mL, and mass detection limit of 1 ng for mercury.

2.
Talanta ; 79(5): 1454-63, 2009 Oct 15.
Article in English | MEDLINE | ID: mdl-19635384

ABSTRACT

The applicability of polyaniline (PANI) for the on-line preconcentration and recovery of palladium from various water samples has been investigated. Batch experiments were performed to optimize conditions such as pH and contact time to achieve quantitative separation of Pd spiked at high (microg ml(-1)) and low levels (ng ml(-1)). During all the steps of the removal process, it was found that Pd was selectively removed by PANI even in the presence of various ions. Quantitative removal of Pd occured in the entire studied pH range (1-12) and the K(d) value was found to be >10(6). Kinetic studies show that a contact time of <4 min was adequate to reach equilibrium. The retained Pd was subsequently eluted with a mixture of HCl and thiourea, optimized using a factorial experimental design approach. ICP-OES was used for the micro-level determinations of Pd whereas ICP-MS was used for the determination of Pd at sub-ppb levels. Breakthrough curve using column experiments demonstrated that PANI has an excellent ability to accumulate up to approximately 120 mg g(-1) of Pd from synthetic sample solutions. A preconcentration factor of about 125 was achieved for Pd when 250 ml of water was passed. PANI columns prepared were used up to 10 times in consecutive retention-elution cycles without appreciable deterioration in their performance. The proposed on-line method also has the ability to remove interfering elements Cu and Y for the determination of Pd in waters by ICP-MS. The reported method has been applied successfully for the determination of Pd in ground water, lake water sea-water and waste water samples. The recoveries were found to be >95% in all cases. These studies indicate that PANI has an excellent ability to preconcentrate Pd from various waters making the method very promising for the determination of Pd.


Subject(s)
Aniline Compounds/isolation & purification , Palladium/isolation & purification , Water Pollutants, Chemical/isolation & purification , Hydrogen-Ion Concentration , Mass Spectrometry/instrumentation , Mass Spectrometry/methods , Mass Spectrometry/standards
3.
Talanta ; 67(1): 70-80, 2005 Jul 15.
Article in English | MEDLINE | ID: mdl-18970139

ABSTRACT

A rapid ultrasound-assisted extraction procedure for the determination of total mercury, inorganic and methyl mercury (MM) in various environmental matrices (animal tissues, samples of plant origin and coal fly ash) has been developed. The mercury contents were estimated by cold vapour atomic absorption spectrometry (CVAAS). Inorganic mercury (IM) was determined using SnCl(2) as reducing agent whereas total mercury was determined after oxidation of methyl mercury through UV irradiation. Operational parameters such as extractant composition (HNO(3) and thiourea), sonication time and sonication amplitude found to be different for different matrices and were optimized using IAEA-350 (Fish homogenate), IM and MM loaded moss and NIST-1633b (Coal fly ash) to get quantitative extraction of total mercury. The method was further validated through the analysis of additional certified reference materials (RM): NRCC-DORM2 (Dogfish muscle), NRCC-DOLT1 (Dogfish liver) and IAEA-336 (Lichen). Quantitative recovery of total Hg was achieved using mixtures of 5% HNO(3) and 0.02% thiourea, 10% HNO(3) and 0.02% thiourea, 20% HNO(3) and 0.2% thiourea for fish tissues, plant matrices and coal fly ash samples, respectively. The results obtained were in close agreement with certified values with an overall precision in the range of 5-15%. The proposed ultrasound-assisted extraction procedure significantly reduces the time required for sample treatment for the extraction of Hg species. The extracted mercury species are very stable even after 24h of sonication. Closed microwave digestion was also used for comparison purposes. The proposed method was applied for the determination of Hg in field samples of lichens, mosses, coal fly ash and coal samples.

SELECTION OF CITATIONS
SEARCH DETAIL