Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters











Database
Language
Publication year range
1.
Nat Commun ; 14(1): 4516, 2023 Jul 31.
Article in English | MEDLINE | ID: mdl-37524731

ABSTRACT

Shape displays which actively manipulate surface geometry are an expanding robotics domain with applications to haptics, manufacturing, aerodynamics, and more. However, existing displays often lack high-fidelity shape morphing, high-speed deformation, and embedded state sensing, limiting their potential uses. Here, we demonstrate a multifunctional soft shape display driven by a 10 × 10 array of scalable cellular units which combine high-speed electrohydraulic soft actuation, magnetic-based sensing, and control circuitry. We report high-performance reversible shape morphing up to 50 Hz, sensing of surface deformations with 0.1 mm sensitivity and external forces with 50 mN sensitivity in each cell, which we demonstrate across a multitude of applications including user interaction, image display, sensing of object mass, and dynamic manipulation of solids and liquids. This work showcases the rich multifunctionality and high-performance capabilities that arise from tightly-integrating large numbers of electrohydraulic actuators, soft sensors, and controllers at a previously undemonstrated scale in soft robotics.

2.
J Biomech Eng ; 140(3)2018 03 01.
Article in English | MEDLINE | ID: mdl-28975262

ABSTRACT

Understanding the impact of thermally and mechanically loading biological tissue to supraphysiological levels is becoming of increasing importance as complex multiphysical tissue-device interactions increase. The ability to conduct accurate, patient specific computer simulations would provide surgeons with valuable insight into the physical processes occurring within the tissue as it is heated or cooled. Several studies have modeled tissue as porous media, yet fully coupled thermoporomechanics (TPM) models are limited. Therefore, this study introduces a small deformation theory of modeling the TPM occurring within biological tissue. Next, the model is used to simulate the mass, momentum, and energy balance occurring within an artery wall when heated by a tissue fusion device and compared to experimental values. Though limited by its small strain assumption, the model predicted final tissue temperature and water content within one standard deviation of experimental data for seven of seven simulations. Additionally, the model showed the ability to predict the final displacement of the tissue to within 15% of experimental results. These results promote potential design of novel medical devices and more accurate simulations allowing for scientists and surgeons to quickly, yet accurately, assess the effects of surgical procedures as well as provide a first step toward a fully coupled large deformation TPM finite element (FE) model.


Subject(s)
Arteries/cytology , Finite Element Analysis , Mechanical Phenomena , Temperature , Biomechanical Phenomena
3.
IEEE Trans Inf Technol Biomed ; 12(1): 66-75, 2008 Jan.
Article in English | MEDLINE | ID: mdl-18270038

ABSTRACT

Long-term human space exploration will require contingencies for emergency medical procedures including some capability to perform surgery. The ability to perform minimally invasive surgery (MIS) would be an important capability. The use of small incisions reduces surgical risk, but also eliminates the ability of the surgeon to view and touch the surgical environment directly. Robotic surgery, or telerobotic surgery, may provide emergency surgical care in remote or harsh environments such as space flight, or extremely forward environments such as battlefields. However, because current surgical robots are large and require extensive support personnel, their implementation has remained limited in forward environments, and they would be difficult, or impossible, to use in space flight or on battlefields. This paper presents experimental analysis of miniature fixed-base and mobile in vivo robots to support MIS surgery in remote and harsh environments. The objective is to develop wireless imaging and task-assisting robots that can be placed inside the abdominal cavity during surgery. Such robots will provide surgical task assistance and enable an on-site or remote surgeon to view the surgical environment from multiple angles. This approach is applicable to long-duration space flight, battlefield situations, and for traditional medical centers and other remote surgical locations.


Subject(s)
Miniaturization , Robotics , Humans , Minimally Invasive Surgical Procedures/methods
4.
Surg Endosc ; 21(9): 1477-81, 2007 Sep.
Article in English | MEDLINE | ID: mdl-17514390

ABSTRACT

The surgical landscape is quickly changing because of the major driving force of robotics. Well-established technology that provides robotic assistance from outside the patient may soon give way to alternative approaches that place the robotic mechanisms inside the patient, whether through traditional laparoscopic ports or through other, natural orifices. While some of this technology is still being developed, other concepts are being evaluated through clinical trials. This article examines the state of the art in surgical robots and mechanisms by providing an overview of the ex vivo robotic systems that are commercially available to in vivo mechanisms, and robotic assistants that are being tested in animal models.


Subject(s)
Endoscopy , Robotics/instrumentation , Animals , Endoscopes , Humans , Laparoscopes , Laparoscopy
5.
Surg Endosc ; 20(1): 135-8, 2006 Jan.
Article in English | MEDLINE | ID: mdl-16333551

ABSTRACT

The use of small incisions in laparoscopy reduces patient trauma, but also limits the surgeon's ability to view and touch the surgical environment directly. These limitations generally restrict the application of laparoscopy to procedures less complex than those performed during open surgery. Although current robot-assisted laparoscopy improves the surgeon's ability to manipulate and visualize the target organs, the instruments and cameras remain fundamentally constrained by the entry incisions. This limits tool tip orientation and optimal camera placement. The current work focuses on developing a new miniature mobile in vivo adjustable-focus camera robot to provide sole visual feedback to surgeons during laparoscopic surgery. A miniature mobile camera robot was inserted through a trocar into the insufflated abdominal cavity of an anesthetized pig. The mobile robot allowed the surgeon to explore the abdominal cavity remotely and view trocar and tool insertion and placement without entry incision constraints. The surgeon then performed a cholecystectomy using the robot camera alone for visual feedback. This successful trial has demonstrated that miniature in vivo mobile robots can provide surgeons with sufficient visual feedback to perform common procedures while reducing patient trauma.


Subject(s)
Abdomen/surgery , Cholecystectomy/methods , Photography/instrumentation , Robotics/instrumentation , Animals , Feedback , Miniaturization , Swine
SELECTION OF CITATIONS
SEARCH DETAIL