Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters











Database
Language
Publication year range
1.
Intensive Care Med Exp ; 12(1): 46, 2024 May 08.
Article in English | MEDLINE | ID: mdl-38717558

ABSTRACT

BACKGROUND: Assessment of dynamic parameters to guide fluid administration is one of the mainstays of current resuscitation strategies. Each test has its own limitations, but passive leg raising (PLR) has emerged as one of the most versatile preload responsiveness tests. However, it requires real-time cardiac output (CO) measurement either through advanced monitoring devices, which are not routinely available, or echocardiography, which is not always feasible. Analysis of the hepatic vein Doppler waveform change, a simpler ultrasound-based assessment, during a dynamic test such as PLR could be useful in predicting preload responsiveness. The objective of this study was to assess the diagnostic accuracy of hepatic vein Doppler S and D-wave velocities during PLR as a predictor of preload responsiveness. METHODS: Prospective observational study conducted in two medical-surgical ICUs in Chile. Patients in circulatory failure and connected to controlled mechanical ventilation were included from August to December 2023. A baseline ultrasound assessment of cardiac function was performed. Then, simultaneously, ultrasound measurements of hepatic vein Doppler S and D waves and cardiac output by continuous pulse contour analysis device were performed during a PLR maneuver. RESULTS: Thirty-seven patients were analyzed. 63% of the patients were preload responsive defined by a 10% increase in CO after passive leg raising. A 20% increase in the maximum S wave velocity after PLR showed the best diagnostic accuracy with a sensitivity of 69.6% (49.1-84.4) and specificity of 92.8 (68.5-99.6) to detect preload responsiveness, with an area under curve of receiving operator characteristic (AUC-ROC) of 0.82 ± 0.07 (p = 0.001 vs. AUC-ROC of 0.5). D-wave velocities showed worse diagnostic accuracy. CONCLUSIONS: Hepatic vein Doppler assessment emerges as a novel complementary technique with adequate predictive capacity to identify preload responsiveness in patients in mechanical ventilation and circulatory failure. This technique could become valuable in scenarios of basic hemodynamic monitoring and when echocardiography is not feasible. Future studies should confirm these results.

2.
Crit Care ; 28(1): 52, 2024 02 19.
Article in English | MEDLINE | ID: mdl-38374167

ABSTRACT

BACKGROUND: Current recommendations support guiding fluid resuscitation through the assessment of fluid responsiveness. Recently, the concept of fluid tolerance and the prevention of venous congestion (VC) have emerged as relevant aspects to be considered to avoid potentially deleterious side effects of fluid resuscitation. However, there is paucity of data on the relationship of fluid responsiveness and VC. This study aims to compare the prevalence of venous congestion in fluid responsive and fluid unresponsive critically ill patients after intensive care (ICU) admission. METHODS: Multicenter, prospective cross-sectional observational study conducted in three medical-surgical ICUs in Chile. Consecutive mechanically ventilated patients that required vasopressors and admitted < 24 h to ICU were included between November 2022 and June 2023. Patients were assessed simultaneously for fluid responsiveness and VC at a single timepoint. Fluid responsiveness status, VC signals such as central venous pressure, estimation of left ventricular filling pressures, lung, and abdominal ultrasound congestion indexes and relevant clinical data were collected. RESULTS: Ninety patients were included. Median age was 63 [45-71] years old, and median SOFA score was 9 [7-11]. Thirty-eight percent of the patients were fluid responsive (FR+), while 62% were fluid unresponsive (FR-). The most prevalent diagnosis was sepsis (41%) followed by respiratory failure (22%). The prevalence of at least one VC signal was not significantly different between FR+ and FR- groups (53% vs. 57%, p = 0.69), as well as the proportion of patients with 2 or 3 VC signals (15% vs. 21%, p = 0.4). We found no association between fluid balance, CRT status, or diagnostic group and the presence of VC signals. CONCLUSIONS: Venous congestion signals were prevalent in both fluid responsive and unresponsive critically ill patients. The presence of venous congestion was not associated with fluid balance or diagnostic group. Further studies should assess the clinical relevance of these results and their potential impact on resuscitation and monitoring practices.


Subject(s)
Hyperemia , Sepsis , Humans , Middle Aged , Aged , Critical Illness/epidemiology , Critical Illness/therapy , Prospective Studies , Cross-Sectional Studies , Hyperemia/complications , Sepsis/complications , Fluid Therapy/methods
4.
Eur Heart J Acute Cardiovasc Care ; 11(10): 786-793, 2022 Nov 02.
Article in English | MEDLINE | ID: mdl-36069621

ABSTRACT

Despite the widespread use of intravenous fluids in acute kidney injury (AKI), solid evidence is lacking. Intravenous fluids mainly improve AKI due to true hypovolaemia, which is difficult to discern at the bedside unless it is very pronounced. Empiric fluid resuscitation triggered only by elevated serum creatinine levels or oliguria is frequently misguided, especially in the presence of fluid intolerance syndromes such as increased extravascular lung water, capillary leak, intra-abdominal hypertension, and systemic venous congestion. While fluid responsiveness tests clearly identify patients who will not benefit from fluid administration (i.e. those without an increase in cardiac output), the presence of fluid responsiveness does not guarantee that fluid therapy is indicated or even safe. This review calls for more attention to the concept of fluid tolerance, incorporating it into a practical algorithm with systematic venous Doppler ultrasonography assessment to use at the bedside, thereby lowering the risk of detrimental kidney congestion in AKI.


Subject(s)
Acute Kidney Injury , Oliguria , Humans , Oliguria/therapy , Acute Kidney Injury/therapy , Fluid Therapy , Kidney
6.
J Crit Care ; 71: 154070, 2022 10.
Article in English | MEDLINE | ID: mdl-35660844

ABSTRACT

Fluid resuscitation is a core component of emergency and critical care medicine. While the focus of clinicians has largely been on detecting patients who would respond to fluid therapy, relatively little work has been done on assessing patients' tolerance to this therapy. In this article we seek to review the concept of fluid tolerance, propose a working definition, and introduce relevant clinical signals by which physicians can assess fluid tolerance, hopefully becoming a starting point for further research.


Subject(s)
Shock, Septic , Critical Care , Fluid Therapy/adverse effects , Humans , Resuscitation , Shock, Septic/therapy
SELECTION OF CITATIONS
SEARCH DETAIL