Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
J Cardiovasc Magn Reson ; 23(1): 35, 2021 03 29.
Article in English | MEDLINE | ID: mdl-33775247

ABSTRACT

BACKGROUND: Quantification of myocardial blood flow (MBF) and myocardial perfusion reserve (MPR) by cardiovascular magnetic resonance (CMR) perfusion requires sampling of the arterial input function (AIF). While variation in the AIF sampling location is known to impact quantification by CMR and positron emission tomography (PET) perfusion, there is no evidence to support the use of a specific location based on their diagnostic accuracy in the detection of coronary artery disease (CAD). This study aimed to evaluate the accuracy of stress MBF and MPR for different AIF sampling locations for the detection of abnormal myocardial perfusion with expert visual assessment as the reference. METHODS: Twenty-five patients with suspected or known CAD underwent vasodilator stress-rest perfusion with a dual-sequence technique at 3T. A low-resolution slice was acquired in 3-chamber view to allow AIF sampling at five different locations: left atrium (LA), basal left ventricle (bLV), mid left ventricle (mLV), apical left ventricle (aLV) and aortic root (AoR). MBF and MPR were estimated at the segmental level using Fermi function-constrained deconvolution. Segments were scored as having normal or abnormal perfusion by visual assessment and the diagnostic accuracy of stress MBF and MPR for each location was evaluated using receiver operating characteristic curve analysis. RESULTS: In both normal (300 out of 400, 75 %) and abnormal segments, rest MBF, stress MBF and MPR were significantly different across AIF sampling locations (p < 0.001). Stress MBF for the AoR (normal: 2.42 (2.15-2.84) mL/g/min; abnormal: 1.71 (1.28-1.98) mL/g/min) had the highest diagnostic accuracy (sensitivity 80 %, specificity 85 %, area under the curve 0.90; p < 0.001 versus stress MBF for all other locations including bLV: normal: 2.78 (2.39-3.14) mL/g/min; abnormal: 2.22 (1.83-2.48) mL/g/min; sensitivity 91 %, specificity 63 %, area under the curve 0.81) and performed better than MPR for the LV locations (p < 0.01). MPR for the AoR (normal: 2.43 (1.95-3.14); abnormal: 1.58 (1.34-1.90)) was not superior to MPR for the bLV (normal: 2.59 (2.04-3.20); abnormal: 1.69 (1.36-2.14); p = 0.717). CONCLUSIONS: The AIF sampling location has a significant impact on MBF and MPR estimates by CMR perfusion, with AoR-based stress MBF comparing favorably to that for the current clinical reference bLV.


Subject(s)
Coronary Artery Disease/diagnostic imaging , Coronary Circulation , Hemodynamics , Magnetic Resonance Imaging, Cine , Myocardial Perfusion Imaging , Aged , Coronary Artery Disease/physiopathology , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Reproducibility of Results , Retrospective Studies
2.
J Magn Reson Imaging ; 51(6): 1689-1696, 2020 06.
Article in English | MEDLINE | ID: mdl-31710769

ABSTRACT

BACKGROUND: Quantitative myocardial perfusion cardiac MRI can provide a fast and robust assessment of myocardial perfusion status for the noninvasive diagnosis of myocardial ischemia while being more objective than visual assessment. However, it currently has limited use in clinical practice due to the challenging postprocessing required, particularly the segmentation. PURPOSE: To evaluate the efficacy of an automated deep learning (DL) pipeline for image processing prior to quantitative analysis. STUDY TYPE: Retrospective. POPULATION: In all, 175 (350 MRI scans; 1050 image series) clinical patients under both rest and stress conditions (135/10/30 training/validation/test). FIELD STRENGTH/SEQUENCE: 3.0T/2D multislice saturation recovery T1 -weighted gradient echo sequence. ASSESSMENT: Accuracy was assessed, as compared to the manual operator, through the mean square error of the distance between landmarks and the Dice similarity coefficient of the segmentation and bounding box detection. Quantitative perfusion maps obtained using the automated DL-based processing were compared to the results obtained with the manually processed images. STATISTICAL TESTS: Bland-Altman plots and intraclass correlation coefficient (ICC) were used to assess the myocardial blood flow (MBF) obtained using the automated DL pipeline, as compared to values obtained by a manual operator. RESULTS: The mean (SD) error in the detection of the time of peak signal enhancement in the left ventricle was 1.49 (1.4) timeframes. The mean (SD) Dice similarity coefficients for the bounding box and myocardial segmentation were 0.93 (0.03) and 0.80 (0.06), respectively. The mean (SD) error in the RV insertion point was 2.8 (1.8) mm. The Bland-Altman plots showed a bias of 2.6% of the mean MBF between the automated and manually processed MBF values on a per-myocardial segment basis. The ICC was 0.89, 95% confidence interval = [0.87, 0.90]. DATA CONCLUSION: We showed high accuracy, compared to manual processing, for the DL-based processing of myocardial perfusion data leading to quantitative values that are similar to those achieved with manual processing. LEVEL OF EVIDENCE: 3 Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2020;51:1689-1696.


Subject(s)
Deep Learning , Humans , Image Processing, Computer-Assisted , Magnetic Resonance Imaging , Perfusion , Retrospective Studies
3.
JACC Cardiovasc Imaging ; 11(5): 686-694, 2018 05.
Article in English | MEDLINE | ID: mdl-29153572

ABSTRACT

OBJECTIVES: This study sought to evaluate the prognostic usefulness of visual and quantitative perfusion cardiac magnetic resonance (CMR) ischemic burden in an unselected group of patients and to assess the validity of consensus-based ischemic burden thresholds extrapolated from nuclear studies. BACKGROUND: There are limited data on the prognostic value of assessing myocardial ischemic burden by CMR, and there are none using quantitative perfusion analysis. METHODS: Patients with suspected coronary artery disease referred for adenosine-stress perfusion CMR were included (n = 395; 70% male; age 58 ± 13 years). The primary endpoint was a composite of cardiovascular death, nonfatal myocardial infarction, aborted sudden death, and revascularization after 90 days. Perfusion scans were assessed visually and with quantitative analysis. Cross-validated Cox regression analysis and net reclassification improvement were used to assess the incremental prognostic value of visual or quantitative perfusion analysis over a baseline clinical model, initially as continuous covariates, then using accepted thresholds of ≥2 segments or ≥10% myocardium. RESULTS: After a median 460 days (interquartile range: 190 to 869 days) follow-up, 52 patients reached the primary endpoint. At 2 years, the addition of ischemic burden was found to increase prognostic value over a baseline model of age, sex, and late gadolinium enhancement (baseline model area under the curve [AUC]: 0.75; visual AUC: 0.84; quantitative AUC: 0.85). Dichotomized quantitative ischemic burden performed better than visual assessment (net reclassification improvement 0.043 vs. 0.003 against baseline model). CONCLUSIONS: This study was the first to address the prognostic benefit of quantitative analysis of perfusion CMR and to support the use of consensus-based ischemic burden thresholds by perfusion CMR for prognostic evaluation of patients with suspected coronary artery disease. Quantitative analysis provided incremental prognostic value to visual assessment and established risk factors, potentially representing an important step forward in the translation of quantitative CMR perfusion analysis to the clinical setting.


Subject(s)
Adenosine/administration & dosage , Coronary Artery Disease/diagnostic imaging , Coronary Circulation , Magnetic Resonance Imaging, Cine , Myocardial Perfusion Imaging/methods , Vasodilator Agents/administration & dosage , Adult , Aged , Coronary Artery Disease/mortality , Coronary Artery Disease/physiopathology , Coronary Artery Disease/therapy , Disease Progression , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Prognosis , Risk Factors , Time Factors
4.
Br Med Bull ; 98: 143-59, 2011.
Article in English | MEDLINE | ID: mdl-21596713

ABSTRACT

BACKGROUND: Cardiovascular disease is the leading cause of morbidity and mortality worldwide. Despite the advances in medical and catheter-based therapy for acute myocardial infarction the 1-year mortality remains as high as 13% and the 5-year prognosis for patients with heart failure remains as high as 50%. Left ventricular systolic dysfunction, a major determinant of prognosis, is associated with significant loss of cardiomyocytes which was previously thought to be irreversible as the heart was considered a post-mitotic organ. SOURCES OF DATA: Review of literature published in peer reviewed journals and ClinicalTrials.Gov website. AREAS OF AGREEMENT: There is now growing evidence that the human heart is capable of undergoing repair and in recent years there has been an increase in basic and clinical research with the aim of harnessing the regenerative properties of stem cells in order to facilitate restoration of myocardial function. AREAS OF CONTROVERSY: The mechanisms of action of cell therapy with regards to cardiac repair remain unsatisfactorily understood and the magnitude of benefit demonstrated in animal models is yet to be fully translated in humans. GROWING POINTS: The number of clinical trials continues to increase and include treating patients with acute myocardial infarction and chronic heart failure secondary to ischaemic heart disease or dilated cardiomyopathy. AREAS TIMELY FOR DEVELOPING RESEARCH: The future of this field of research will require closer collaboration between scientists and clinicians to understand how cell therapy works and to define the ideal cell type and method of delivery to be able to derive maximum benefit.


Subject(s)
Heart Diseases/therapy , Stem Cell Transplantation/methods , Cardiomyopathy, Dilated/therapy , Clinical Trials as Topic , Heart Failure/therapy , Humans , Myocardial Infarction/therapy
SELECTION OF CITATIONS
SEARCH DETAIL