Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 21
Filter
Add more filters










Publication year range
1.
Article in English | WPRIM (Western Pacific) | ID: wpr-1040940

ABSTRACT

To obtain better esthetic results when immediately placing a dental implant, the soft tissue surrounding the implant must be conditioned during healing of the extraction socket. To this end, the emergence profile can be customized through immediate restoration of the provisional prosthesis, and good clinical results can be obtained at the time of definitive restoration in the future, resulting in high patient satisfaction. In this case, horizontal root fracture occurred after trauma to both maxillary central incisors.Immediate implant placement and loading was planned considering aesthetics and alveolar bone condition. By taking an impression using a digital intraoral scanner, a digital diagnostic wax-up was performed to make a more aesthetic prosthesis without applying external force to the traumatized teeth. Based on this, the ideal placement location was determined and immediate implant placement was performed using a 3D printed surgical guide. The provisional prosthesis was restored 5 days after placement, and the definitive zirconia crown was restored through soft tissue conditioning and customization using the shape of the provisional prosthesis for 3 months.

2.
Article in English | WPRIM (Western Pacific) | ID: wpr-1040945

ABSTRACT

The concept of ‘Implant Supracrestal Complex (ISC)’ was introduced as a way to determine the impact of implant prosthetic design form on both short-term clinical outcomes and the long-term prognosis of bone and soft tissues around the implant.Implant-prosthesis-abutment complex design forms, such as implant-abutment design, junction, and location, can have important implications for the stable and healthy long-term maintenance of the tissues around the implant. In this case, a customized concave abutment and a prosthesis with an emergence angle of about 30 degrees were restored to a patient suffering from chronic soft tissue inflammation and pain after restoration of an implant prosthesis. It was confirmed that the new prosthesis improved complications by allowing sufficient bone and soft tissue space, achieved appropriate soft tissue sealing, and maintained the longterm stability of the implant.

3.
Article in English | WPRIM (Western Pacific) | ID: wpr-1040952

ABSTRACT

Recently, computer-aided design and computer-aided manufacturing (CAD/CAM) environment have changed the clinician treatment method in the fabrication of prosthesis. The diagnostic wax-up by using digital technology simplifies the laboratory process and provides clinical efficiency and convenience. In this case, Digital diagnostic wax-up was superimposed on extra-oral photo to consider the patient’s facial appearance and utilized to produce the final prosthesis. It can be more efficient and esthetic than a diagnostic wax-up that was made only on a model. The digital diagnostic wax-up that superimposed on extra-oral photo not only visualizes the predicted outcome of prosthodontic treatment but also improves satisfaction and facilitates the communication between patient and dentist. We report aesthetically and functionally satisfactory results that obtained after restoration.

4.
Article in English | WPRIM (Western Pacific) | ID: wpr-1040953

ABSTRACT

Fabrication of dentures using CAD/CAM system has the advantage of reducing the number of patient visits and reducing errors during laboratory work. After the extraction of maxillary residual teeth, this patient changed to a completely edentulous state and the stability and retention of the existing mandibular complete denture were insufficient due to the absorption of the mandibular residual ridge, so the restoration of the mandibular implant retained overdenture and maxillary complete denture were planned.By digitizing the concept of BPS (Biofunctional prosthetic system) that uses the patient’s functional movement in closed mouth technique, the vertical dimension was taken by Gnathometer CAD and digital facebow transfer was performed using UTS CAD. In this case, fabrication of maxillary complete denture and mandibular implant-retained overdenture using monolithic disc and CAD/ CAM system demonstrated favorable denture retention, stability, and support and the patient is satisfied with improved functions and esthetic of dentures.

5.
Article in English | WPRIM (Western Pacific) | ID: wpr-1040968

ABSTRACT

Long-term use of inappropriate prosthesis often results in habitual closure or irregular mandibular movements. In that case, guide to the stable centric position is difficult. Therefore, by using a treatment denture, the muscles and TMJ should be stabilized and the jaw relation should be acquired with the treatment position. Compared to the conventional method, digital technology in fabrica-tion complete denture has the advantage of reproducing a stable tooth arrangement in cases of difficult tooth alignment, minimiz-ing laboratory errors and reducing denture fabrication time. Therefore, in this case, the final denture was fabricated by digitally re-producing the stable treatment position, vertical dimension, and lip support with a treatment denture, and satisfactory results wereobtained.

6.
Article in English | WPRIM (Western Pacific) | ID: wpr-968647

ABSTRACT

Dental trauma is common in active children and adolescents. Among them, in the case of ankylosis due to avulsion, diagnosis through clinical examination is important, and the treatment is important for esthetic prosthetic restoration after adulthood. This case is a case of esthetic prosthetic restoration of maxillary anterior teeth through decoronation and implant. After that, space was maintained for prosthetic restoration using a decoronated crown. After becoming an adult, precise implant placement and esthetic prosthetic restoration were possible using guide surgery. For soft tissue support, the temporary crown were replaced by changing the contours of the temporary crown, and the final esthetic prosthesis was fabricated by digital wax-up.

7.
Article in English | WPRIM (Western Pacific) | ID: wpr-1002901

ABSTRACT

In this case, a CAD-CAM complete denture that can be easily remanufactured and reduced the number of visits was decided in consideration of the fact that it was difficult to visit the dental hospital and many existing dentures were lost because the patient was inpatient in a nursing hospital. In order to reflect the shape, vertical dimension, and maxillomandibular relationship of the existing provisional dentures adapted by the patient to the fabrication of the final denture, the existing provisional dentures were scanned and closed mouth impression was taken with the printed individual tray. After digital facebow transfer using UTS CAD and arranging artificial teeth in CAD software, the maxillary and mandibular complete dentures were fabricated by milling the denture base and artificial teeth at once with the monolithic disc.

8.
Article in English | WPRIM (Western Pacific) | ID: wpr-926947

ABSTRACT

Recently with the advance in digital dentistry, the fabrication of dentures using computer-aided design and computer-aided manufacturing (CAD-CAM) is on the rise. The denture designed through a CAD software can be produced in a 3-dimensional manufacturing process. This process includes a subtractive processing method such as milling and an additive processing method such as 3D printing and in which it can be applied efficiently in more complex structures. In this case, complete dentures were fabricated using Stereolithography (SLA)-based 3D printing to shorten the production time and interval of visits in patient with physical disabilities due to cerebral infarction. For definitive impression, the existing interim denture was digitally replicated and used as an individual tray. The definitive impression obtained with polyvinyl siloxane impression material was including information about the inclination and length of the maxillary anterior teeth, vertical dimension, and centric relation. In addition, facial scan data with interim denture was obtained so that it can be used as a reference in determination of the occlusal plane and in arrangement of artificial teeth during laboratory work. Artificial teeth were arranged through a CAD program, and a gingival festooning was performed. The definitive dentures were printed by SLA-based 3D printer using a FDA-approved liquid photocurable resin. The denture showed adequate retention, support, and stability, and results were satisfied functionally and aesthetically.

9.
Article in English | WPRIM (Western Pacific) | ID: wpr-967151

ABSTRACT

The implant prosthesis of anterior maxilla requires careful consideration in planning. In order to satisfy both esthetic and functional needs of a patient, fusion of intra-oral scan in Cone-beam computed tomography (CBCT) and facial scan can be considered. Bony structures and soft tissues captured in CBCT and occlusal surfaces of intra oral scan were incorporated into personal characteristics from facial scan. The patient had insufficient buccal bone on maxillary anterior area. The maxillary implants could not be placed on the most ideal position. However, the “top down” approach completed by computer-generated arranging of teeth in implant planning and surgery with surgical guide resulted in esthetically and functionally satisfying result regardless of the limitation. Careful diagnosis with digital technique and the usage of surgical guide resulted in successful surgery and esthetic restoration. The temporary fixed prostheses were designed, restored and evaluated. The patient was not satisfied with the first design of temporary prosthesis, which showed uneven space distribution between teeth due to the position of maxillary implant. The design was modified by changing proximal emergence contours and line angle to alter the perceived since of incisors. The patient was satisfied with the new design of provisional restoration. A digital occlusion analyzer (Arcus Digma II, KaVo, Leutkirch, Germany) was used to measure inherent condylar guidance and anterior guidance of a patient to provide a definitive prosthesis.

10.
Article in English | WPRIM (Western Pacific) | ID: wpr-967152

ABSTRACT

Recently, through the development of CAD/CAM technology, it is also being used for fabricating dentures. Compared to conventional methods, when digital dentures are fabricated, the fabrication process is facilitated, and the number of visits to hospitals is reduced and errors are reduced. In this case, the vertical dimension was increased using a CAD program in a patient who needed vertical dimension recovery due to the use of old dentures, and the final denture was fabricated using a monolithic disc through the milling method. The centric relation was recorded using existing dentures, and using the information from the intraoral scan and the existing denture model scan, a trial denture was fabricated and delivered to the patient to evaluate the midline and occlusion. Based on the evaluation of the trial denture, the final denture was fabricated using a milling method and a monolithic disc, and the final denture showed satisfactory results functionally and aesthetically.

11.
Article in English | WPRIM (Western Pacific) | ID: wpr-918858

ABSTRACT

Successful cases of the implant-assisted removable partial denture and implant overdentures are reported in which a few implants are additionally placed to secure the maintenance, support, and stability of the denture when there are a few residual teeth. When the lateral force applied to the tooth abutment and implant surveyed crown is minimized, the horizontal and rotational movement of the denture is significantly reduced which is an effective method that can improve the address in patients who complain of reduced retention and stability of their dentures. In this case, a small number of implants were placed to fabricate an implant-assisted removable partial denture with implant surveyed crown in the maxilla and implant overdenture with Locator® attachment in the mandible to improve the retention, stability, and support of the dentures. The patient was satisfied with both functional and aesthetic aspects after the final dentures were delivered.

12.
Article in English | WPRIM (Western Pacific) | ID: wpr-918859

ABSTRACT

In this report, Replicated denture was fabricated by 3d printing after scanning the existing denture. It was used as an individual tray in closed-mouth technique.It reduced laboratory process and clinical time. Also it helped in facial evaluation and tooth arrangement. Compared to open-mouth technique, the number of visits was reduced, and the patient’s adaptability to new denture was enhanced by utilized various information of the existing denture, including vertical dimension.

13.
Article in English | WPRIM (Western Pacific) | ID: wpr-918864

ABSTRACT

In patients with myasthenia gravis, it is difficult to manufacture and maintain dentures because the muscles and nervous system in the oral cavity are not properly adjusted. In addition, excessively extended or thick dentures may cause muscle weakness by stimulating the muscles, so dentures should be manufactured in consideration of this. In this case, a denture was fabricated using the closed mouth technique in a patient with myasthenia gravis with mouth opening limitation. Using the closed mouth technique, the patient’s masticatory pressure and muscle movements were reproduced and denture with good retention were manufactured.

14.
Article in English | WPRIM (Western Pacific) | ID: wpr-914637

ABSTRACT

Increasing the vertical dimesion affects not only functional problems but also the facial appearance. In particular, when restoring the reduced vertical dimension, it is important to evaluate facial appearance because the change affects the patient’s aesthetics. Cephalometric radiographs can predict changes in the facial appearance through skeletal and vertical classifications using anatomical indicators, and the changes before and after treatment can be easily observed, which could serve as good data in evaluating treatment success. In this study, comparative evaluation was performed through cephalometric radiography, and the aesthetic and functional improvement was confirmed.

15.
Article in English | WPRIM (Western Pacific) | ID: wpr-896267

ABSTRACT

Oxaliplatin, a third-generation platinum derivative, is the mainstay of current antineoplastic medications for advanced colorectal cancer therapy. However, peripheral neuropathic complications, especially cold allodynia, undermine the lifeprolonging outcome of this anti-cancer agent. Rosavin, a phenylpropanoid derived originally from Rhodiola rosea, exhibits a wide range of therapeutic properties. The present study explored whether and how rosavin alleviates oxaliplatin-induced cold hypersensitivity in mice. In the acetone drop test, cold allodynia behavior was observed from days 3 to 5 after a single injection of oxaliplatin (6 mg/kg, i.p.). Cold allodynia was significantly attenuated following rosavin treatment (10 mg/kg, i.p.). Specific endogenous 5-HT depletion by three consecutive pretreatments with parachlorophenylalanine (150 mg/kg/day, i.p.) abolished the analgesic action of rosavin; this effect was not observed following pretreatment with naloxone (opioid receptor antagonist, 10 mg/kg, i.p.). Furthermore, 5-HT1A receptor antagonist WAY-100635 (0.16 mg/kg, i.p.), but not 5-HT3 receptor antagonist MDL-72222 (1 mg/kg, i.p.), blocked rosavin-induced analgesia. These results suggest that rosavin may provide a novel approach to alleviate oxaliplatin-induced cold allodynia by recruiting the activity of 5-HT1A receptors.

16.
Article in English | WPRIM (Western Pacific) | ID: wpr-903971

ABSTRACT

Oxaliplatin, a third-generation platinum derivative, is the mainstay of current antineoplastic medications for advanced colorectal cancer therapy. However, peripheral neuropathic complications, especially cold allodynia, undermine the lifeprolonging outcome of this anti-cancer agent. Rosavin, a phenylpropanoid derived originally from Rhodiola rosea, exhibits a wide range of therapeutic properties. The present study explored whether and how rosavin alleviates oxaliplatin-induced cold hypersensitivity in mice. In the acetone drop test, cold allodynia behavior was observed from days 3 to 5 after a single injection of oxaliplatin (6 mg/kg, i.p.). Cold allodynia was significantly attenuated following rosavin treatment (10 mg/kg, i.p.). Specific endogenous 5-HT depletion by three consecutive pretreatments with parachlorophenylalanine (150 mg/kg/day, i.p.) abolished the analgesic action of rosavin; this effect was not observed following pretreatment with naloxone (opioid receptor antagonist, 10 mg/kg, i.p.). Furthermore, 5-HT1A receptor antagonist WAY-100635 (0.16 mg/kg, i.p.), but not 5-HT3 receptor antagonist MDL-72222 (1 mg/kg, i.p.), blocked rosavin-induced analgesia. These results suggest that rosavin may provide a novel approach to alleviate oxaliplatin-induced cold allodynia by recruiting the activity of 5-HT1A receptors.

17.
Article in Korean | WPRIM (Western Pacific) | ID: wpr-714250

ABSTRACT

Conventional denture impression techniques have limitations for edentulous patients with severe alveolar bone resorption and can cause problems from excessive border extension. Especially when a patient has movable tissue it is difficult to make accurate impression, thus might interrupt stable seating of complete denture. Fabrication of complete denture using closed mouth technique for edentulous patient with severe ridge resorption is thought to provide better stability and retention. In this case, an 86-year-old patient had both edentulous jaws with epulis fissuratum on maxillary anterior ridge and severe mandibular ridge resorption. Thus, tentative vertical dimension was determined by using Centric tray and individual tray attached with gothic arch tracer was fabricated. Complete denture was fabricated using closed mouth technique and the patient was satisfied with better stability and retention of the complete denture.


Subject(s)
Aged, 80 and over , Humans , Bone Resorption , Denture, Complete , Dentures , Gingival Diseases , Jaw, Edentulous , Mouth , Vertical Dimension
18.
Article in Korean | WPRIM (Western Pacific) | ID: wpr-126464

ABSTRACT

Attention-deficit hyperactivity disorder (ADHD) is a highly prevalent, impairing, and comorbid disorder that persists into adulthood. ADHD should be diagnosed in the same manner as other common adult mental health disorders. The three most important components in the comprehensive evaluation of patients with ADHD are the clinical interview, medical examination, and completion and scoring of behavior rating scales. The diagnostic evaluation of ADHD should include questions about the symptoms, family history, prior evaluation and treatment of ADHD, as well as other problems including alcohol and drug use. Screening interviews or rating scales, as well as interviews, should be used. When it is feasible, clinicians may wish to supplement these components of the evaluation with the objective assessments of the ADHD symptoms, such as through psychological tests. These tests are not essential to reaching a diagnosis, however, or to treatment planning, but may yield further information about the presence and severity of cognitive impairments that could be associated with some cases of ADHD. As comorbidity is the rule rather than the exception, clinicians should carefully screen for comorbid disorders as part of a comprehensive assessment of ADHD. To receive a diagnosis of ADHD, the person must be experiencing significant distress or impairment in his or her daily functioning, and must not meet the criteria for other mental disorders which might better account for the observed symptoms, such as mental retardation, autism or other pervasive developmental disorders, mood disorders and anxiety disorders. This report aims to suggest practice guidelines for the assessment and diagnosis of children, adolescents and adults with ADHD in Korea.


Subject(s)
Adolescent , Adult , Child , Humans , Anxiety Disorders , Autistic Disorder , Behavior Rating Scale , Cognition Disorders , Comorbidity , Diagnosis , Intellectual Disability , Korea , Mass Screening , Mental Disorders , Mental Health , Mood Disorders , Psychological Tests , Weights and Measures
19.
Article in Korean | WPRIM (Western Pacific) | ID: wpr-68824

ABSTRACT

Adoption of CAD/CAM milling in dentistry has allowed production of more analytic and precise prosthesis. Such precision enables definite path of insertion and undercut to be provided in removable partial denture especially when designing a surveyed crown on an abutment tooth. This case is about the production of surveyed crown with proper path of insertion utilizing CAD/CAM electronic surveying method on a patient with edentulous maxilla. Resulting removable partial denture fit well and showed acceptable stability and retention with no clinical problem.


Subject(s)
Humans , Crowns , Dental Prosthesis , Dentistry , Denture, Partial, Removable , Maxilla , Methods , Prostheses and Implants , Tooth
20.
Article in Korean | WPRIM (Western Pacific) | ID: wpr-81242

ABSTRACT

The Gothic arch tracing method using a Gothic arch tracer which is one of the centric relation recording methods can reproduce mandibular movement more accurately by describing the path of mandibular curvilinear motion. This case reports that we have satisfactory results by recording reproducible centric relation using a gothic arch tracing method in a patient who has difficulty to induce centric relation by operator due to parafunctional movement.


Subject(s)
Humans , Centric Relation , Mouth Rehabilitation , Mouth
SELECTION OF CITATIONS
SEARCH DETAIL